Performance Analysis of an Air Drier for a Liquid Dehumidifier Solar Air Conditioning System

1988 ◽  
Vol 110 (2) ◽  
pp. 120-124 ◽  
Author(s):  
A. G. Queiroz ◽  
A. F. Orlando ◽  
F. E. M. Saboya

A model was developed for calculating the operating conditions of a non-adiabatic liquid dehumidifier used in solar air conditioning systems. In the experimental facility used for obtaining the data, air and triethylene glycol circulate countercurrently outside staggered copper tubes which are the filling of an absorption tower. Water flows inside the copper tubes, thus cooling the whole system and increasing the mass transfer potential for drying air. The methodology for calculating the mass transfer coefficient is based on the Merkel integral approach, taking into account the lowering of the water vapor pressure in equilibrium with the water glycol solution.

2015 ◽  
Vol 12 (1) ◽  
pp. 46-51
Author(s):  
Baghdad Science Journal

In a hybrid cooling solar thermal systems , a solar collector is used to convert solar energy into heat energy in order to super heat the refrigerant leaving the compressor, and this process helps in the transformation of refrigerant state from gaseous state to the liquid state in upper two-thirds of the condenser instead of the lower two-thirds such as in the traditional air-conditioning systems and this will reduce the energy needed to run the process of cooling .In this research two systems with a capacity of 2 tons each were used, a hybrid air-conditioning system with an evacuated tubes solar collector and a traditional air-conditioning system . The refrigerant of each type was R22.The comparison was in the amount of energy and current consumption of the two systems at the same operating conditions. The energy consumed and the current of the hybrid system were less than the traditional air-conditioning system by 12% and 28.6% respectively, which means that there is a saving in the energy and current consumption as a result of the use of the solar thermal collector.


2012 ◽  
Vol 170-173 ◽  
pp. 2652-2656 ◽  
Author(s):  
Ming He Dai ◽  
Zhi Ping Zhou ◽  
Xing Xue

In this paper, the operating conditions of air-conditioning systems in Terminal building of Guilin LiangJiang International Airport were tested and analysed. This paper mainly analyzes the influence of chilled water temperature on water chiller performance and derives the relationship of COP of water chiller and chilled water temperature difference between inlet and outlet , and provides reference for operation mode’s optimization of the air-conditioning system and energy consumption reduction of the whole building.


2019 ◽  
Vol 6 (3) ◽  
pp. 80-85
Author(s):  
Denis Igorevich Smagin ◽  
Konstantin Igorevich Starostin ◽  
Roman Sergeevich Savelyev ◽  
Anatoly Anatolyevich Satin ◽  
Anastasiya Romanovna Neveshkina ◽  
...  

One of the ways to achieve safety and comfort is to improve on-board air conditioning systems.The use of air cooling machine determines the air pressure high level at the point of selection from the aircraft engine compressor. Because of the aircraft operation in different modes and especially in the modes of small gas engines, deliberately high stages of selection have to be used for ensuring proper operation of the refrigeration machine in the modes of the aircraft small gas engines. Into force of this, most modes of aircraft operation have to throttle the pressure of the selected stage of selection, which, together with the low efficiency of the air cycle cooling system, makes the currently used air conditioning systems energy inefficient.A key feature of the architecture without air extraction from the main engines compressors is the use of electric drive compressors as a source of compressed air.A comparative analysis of competing variants of on-board air conditioning system without air extraction from engines for longrange aircraft projects was performed at the Moscow Aviation Institute (National Research University).The article deals with the main approaches to the decision-making process on the appearance of a promising aircraft on-board air conditioning system at the stage of its conceptual design and formulated the basic requirements for the structure of a complex criterion at different life cycle stages.The level of technical and technological risk, together with a larger installation weight, will require significant costs for development, testing, debugging and subsequent implementation, but at the same time on-board air conditioning system scheme without air extraction from the engines will achieve a significant increase in fuel efficiency at the level of the entire aircraft.


2014 ◽  
Vol 493 ◽  
pp. 74-79
Author(s):  
Y.A. Sabtalistia ◽  
S.N.N. Ekasiwi ◽  
B. Iskandriawan

Energy consumption for air conditioning systems (air conditioning system) increased along with the increasing need for fresh air and comfortable in the room especially apartments. FAC system (Floor Air Conditioning) is growing because it is more energy efficient than CAC (Ceiling Air Conditioning) system. However, the position of the AC supply is on the lower level at the FAC system causes draft discomfort becomes greater as air supply closer to the occupants so that thermal comfort can be reduced. Heat mixture of windows, exterior walls, kitchen, and occupants in the studio apartment affect thermal comfort in the room too.This study aims to determine the position of the AC supply which has the best thermal comfort of FAC system in the studio apartment. It can be done by analyzing ADPI (Air Diffusion Performance Index), the distribution of air temperature, wind speed, RH (Relative Humidity), and DR (Draft Risk) to change the position of the AC supply supported by CFD (Computational Fluid Dynamics) simulation.This result prove that AC position 2 (on wall near the kitchen) is more comfortable than AC position 1 (on the bathroom wall) because AC position 2 away from occupied areas, thereby reducing the occurrence of draught discomfort.


2017 ◽  
Vol 140 (1) ◽  
Author(s):  
Lianying Zhang ◽  
Yuanyuan Liu ◽  
Yuan Wang ◽  
Liwen Jin ◽  
Qunli Zhang ◽  
...  

The absorption air-conditioning system is a low-power-consumption and low-noise system and is also good at balancing the electricity peak-valley system. It can be driven by low-grade energy, such as solar energy and industrial exhaust heat. The nanofluids, which possess the superior thermophysical properties, exhibit a great potential in enhancing heat and mass transfer. In this paper, nanofluids of H2O/LiBr with Fe3O4 nanoparticles were introduced into absorption air conditioning system. The effects of critical parameters, such as the flow rate of H2O/LiBr nanofluids, nanoparticle size and mass fraction, on the falling film absorption were investigated. The H2O/LiBr nanofluids with Fe3O4 nanoparticle mass fractions of 0.01 wt %, 0.05 wt % and 0.1 wt %, and nanoparticle sizes of 20 nm, 50 nm and 100 nm were tested. The results imply that the vapor absorption rate could be improved by adding the nanoparticles to H2O/LiBr solution. The smaller the nanoparticle size, the greater the enhancement of the heat and mass transfer. The absorption enhancement ratio increases sharply at first by increasing the nanoparticle mass fraction within a range of relatively low mass fraction and then exhibits a slow growing even reducing trends with increasing the mass fraction further. For Fe3O4 nanoparticle mass fraction of 0.05 wt % and nanoparticle size of 20 nm, the maximum mass transfer enhancement ratio is achieved about 2.28 at the flow rate of 100 L h−1. Meanwhile, a fitting formula of mass transfer enhancement ratio for Fe3O4 nanofluids has been improved.


2005 ◽  
Vol 16 (4) ◽  
pp. 59-66 ◽  
Author(s):  
V Mittal ◽  
KS Kasana ◽  
NS Thakur

An air-conditioning system utilizing solar energy would generally be more efficient, cost wise, if it was used to provide both heating and cooling requirements in the building it serves. Various solar powered heating systems have been tested extensively, but solar powered air conditioning systems have received very little attention. Solar powered absorption cooling systems can serve both heating and cooling requirements in the building it serves. Many researchers have studied the solar absorption air conditioning system in order to make it economically and technically viable. But still, much more research in this area is needed. This paper will help many researchers working in this area and provide them with fundamental knowledge on absorption systems, and a detailed review on the past efforts in the field of solar absorption cooling systems with the absorption pair of lithium-bromide and water. This knowledge will help them to start the parametric study in order to investigate the influence of key parameters on the overall system performance.


Author(s):  
Somaye A. Mohamadi ◽  
Abdulraheem J. Ahmed

<span>Despite their complexity and uncertainty, air conditioning systems should provide the optimal thermal conditions in a building. These controller systems should be adaptable to changes in environmental parameters. In most air conditioning systems, today, there are On/Off controllers or PID in more advanced types, which, due to different environmental conditions, are not optimal and cannot provide the optimal environmental conditions. Controlling thermal comfort of an air conditioning system requires estimation of thermal comfort index. In this study, fuzzy controller was used to provide thermal comfort in an air conditioning system, and neural network was used to estimate thermal comfort in the feedback path of the controller. Fuzzy controller has a good response given the non-linear features of air conditioning systems. In addition, the neural network makes it possible to use thermal comfort feedback in a real-time control.</span>


2019 ◽  
Vol 95 (3) ◽  
pp. 296-301
Author(s):  
U. A. Rakhmanin ◽  
S. E. Shibanov ◽  
Sergey V. Kozulya

Purpose of work is a compilation of data about the microflora which colonizes a split-system, with the aim of selection of sanitary-indicative microorganisms, whose presence in the sample would indicate to the need for cleaning and disinfection of split-systems. Materials and methods. In the article there were used data of five years author’s scientific inquiry, related to the prevention of respiratory diseases, associated with the usage of a local air conditioning systems. We also use the data from the literature. Results. For selection of “indicative” microorganisms, we proposed the usage of nine criteria, each of them have numeric value from 0 to 3 points (risk for health, prevalence rate of the disease, epidemiological link, speed of split system’s colonization, difficulty of cultivation, resistance in the environment, resistance to disinfectants, frequency of detection in home air conditioning systems, frequency of detection in air conditioning systems of public buildings). After the calculation Pseudomonas aeruginosa and Staphylococcus aureus received maximal score (20 points). Therefore, these two types of bacteria are indicative microorganisms. The detection of these microorganisms in split systems will indicate to the contamination of air-conditioning system. This microflora also is a criterion of cleaning and disinfection quality - presence of these microorganisms in the samples after this process will mean that the processing of air conditioning systems was performed poorly. Conclusions. Split systems are very faster colonized by conditionally pathogenic and pathogenic microflora. To prevent the possible hazard for population’s health it is necessary to develop the normative base, according to which sanitary-and-hygienic control over the split-systems working must be carried out. Proposed criteria suggest that Pseudomonas aeruginosa and Staphylococcus aureus are indicative microorganisms, and it’s identification in the air-conditioning system would mean risk for health and necessity for cleaning and disinfection.


Author(s):  
Ali Mohammad Jafarpour ◽  
Farivar Fazelpour ◽  
Seyyed Abbas Mousavi

AbstractIn this study an experimental design was developed to optimize the performance and structure of a membrane-based parallel-plate liquid desiccant dehumidifier used in air conditioning regeneration system which operates under high humidity weather conditions. We conducted a series of polymeric porous membranes with different compositions fabricated that were prepared with various weight percentages of polysulfone (PSU), mixed with N-methyl-2-pyrrolidone (NMP) and dimethyl form amide (DMF) solvents. Furthermore, the designed experiments were performed under various operating conditions, indicating that the dehumidification efficiency declines with increasing flow rate, temperature, and humidity. Consequently, a membrane with optimized porosity and moisture permeability was selected which resulted in eliminating the carryover of solution droplets in the air, largely due to separating the flow condition of liquid desiccant (Li Cl) and air. This specific design is also greatly benefited by removing the water vapor from the air stream. The results of mathematical model simulations indicate that the DMF solvent had higher dehumidification capability compared with that of NMP under the optimized operating conditions. Additionally, it can clarify the porosity of the membrane which plays a significant role in the overall performance. Therefore, the fabricated membrane produces fresh cool air, and it can be applied as a guiding sample for designing the membrane-based dehumidifier with improved performance.