Shower Head and Trailing Edge Cooling Influence on Transonic Vane Aero Performance

2014 ◽  
Vol 136 (11) ◽  
Author(s):  
Ranjan Saha ◽  
Jens Fridh ◽  
Torsten H. Fransson ◽  
Boris I. Mamaev ◽  
Mats Annerfeldt ◽  
...  

An experimental investigation on a cooled nozzle guide vane (NGV) has been conducted in an annular sector to quantify aerodynamic influences of shower head (SH) and trailing edge (TE) cooling. The investigated vane is a typical high pressure gas turbine vane, geometrically similar to a real engine component, operated at a reference exit Mach number of 0.89. The investigations have been performed for various coolant-to-mainstream mass–flux ratios. New loss equations are derived and implemented regarding coolant aerodynamic losses. Results lead to a conclusion that both TE cooling and SH film cooling increase the aerodynamic loss compared to an uncooled case. In addition, the TE cooling has higher aerodynamic loss compared to the SH cooling. Secondary losses decrease with inserting SH film cooling compared to the uncooled case. The TE cooling appears to have less impact on the secondary loss compared to the SH cooling. Area-averaged exit flow angles around midspan increase for the TE cooling.

Author(s):  
Ranjan Saha ◽  
Jens Fridh ◽  
Torsten H. Fransson ◽  
Boris I. Mamaev ◽  
Mats Annerfeldt ◽  
...  

An experimental investigation on a cooled nozzle guide vane has been conducted in an annular sector to quantify aerodynamic influences of shower head and trailing edge cooling. The investigated vane is a typical high pressure gas turbine vane, geometrically similar to a real engine component, operated at a reference exit Mach number of 0.89. The investigations have been performed for various coolant-to-mainstream mass-flux ratios. New loss equations are derived and implemented regarding coolant aerodynamic losses. Results lead to a conclusion that both trailing edge cooling and shower head film cooling increase the aerodynamic loss compared to an uncooled case. In addition, the trailing edge cooling has higher aerodynamic loss compared to the shower head cooling. Secondary losses decrease with inserting shower head film cooling compared to the uncooled case. The trailing edge cooling appears to have less impact on the secondary loss compared to the shower head cooling. Area-averaged exit flow angles around midspan increase for the trailing edge cooling.


Author(s):  
S. Ravelli ◽  
G. Barigozzi

The main purpose of this numerical investigation is to overcome the limitations of the steady modeling in predicting the cooling efficiency over the cutback surface in a high pressure turbine nozzle guide vane. Since discrepancy between Reynolds-averaged Navier–Stokes (RANS) predictions and measured thermal coverage at the trailing edge was attributable to unsteadiness, Unsteady RANS (URANS) modeling was implemented to evaluate improvements in simulating the mixing between the mainstream and the coolant exiting the cutback slot. With the aim of reducing the computation effort, only a portion of the airfoil along the span was simulated at an exit Mach number of Ma2is = 0.2. Three values of the coolant-to-mainstream mass flow ratio were considered: MFR = 0.66%, 1.05%, and 1.44%. Nevertheless the inherent vortex shedding from the cutback lip was somehow captured by the URANS method, the computed mixing was not enough to reproduce the measured drop in adiabatic effectiveness η along the streamwise direction, over the cutback surface. So modeling was taken a step further by using the Scale Adaptive Simulation (SAS) method at MFR = 1.05%. Results from the SAS approach were found to have potential to mimic the experimental measurements. Vortices shedding from the cutback lip were well predicted in shape and magnitude, but with a lower frequency, as compared to PIV data and flow visualizations. Moreover, the simulated reduction in film cooling effectiveness toward the trailing edge was similar to that observed experimentally.


Author(s):  
Ranjan Saha ◽  
Boris I. Mamaev ◽  
Jens Fridh ◽  
Björn Laumert ◽  
Torsten H. Fransson

Experiments are conducted to investigate the effect of the pre-history in the aerodynamic performance of a three-dimensional nozzle guide vane with a hub leading edge contouring. The performance is determined with two pneumatic probes (5 hole and 3 hole) concentrating mainly on the endwall. The investigated vane is a geometrically similar gas turbine vane for the first stage with a reference exit Mach number of 0.9. Results are compared for the baseline and filleted cases for a wide range of operating exit Mach numbers from 0.5 to 0.9. The presented data includes loading distributions, loss distributions, fields of exit flow angles, velocity vector and vorticity contour, as well as, mass-averaged loss coefficients. The results show an insignificant influence of the leading edge fillet on the performance of the vane. However, the pre-history (inlet condition) affects significantly in the secondary loss. Additionally, an oil visualization technique yields information about the streamlines on the solid vane surface which allows identifying the locations of secondary flow vortices, stagnation line and saddle point.


Author(s):  
C. Osnaghi ◽  
A. Perdichizzi ◽  
M. Savini ◽  
P. Harasgama ◽  
E. Lutum

The paper presents the results of an investigation on the aerodynamic performance of a full coverage film-cooled nozzle guide vane. The blading is a typical high pressure turbine vane of advanced design, working in the high subsonic regime. Tests have been carried out for a wide range of conditions, including variations in Mach number, coolant to mainstream mass flow rate ratio and location of the coolant injection. Both air and carbon dioxide at ambient conditions have been utilized, as coolant flow. Measurements have been performed in a plane located at 0.5 axial chord downstream of the trailing edge by means of a miniaturized five-hole pressure probe. Performances, in terms of losses, flow angles and profile pressure distributions, for different cooling mass flow rates are presented and compared to the results of the solid blade tests (i.e. with no cooling holes). The results showed a significant increase of the losses with blowing. Test with air and carbon dioxide provided almost equal losses if carried out at the same global momentum flux ratio; however the density ratio was found to influence slightly the share of the coolant fluid among the injection rows and the local momentum flux ratio as well. In order to define the individual contributions of groups of cooling rows on the performance of the blade, three different modes of injection have been tested, namely full, trailing edge and shower head injection. The main trend observed is that trailing edge injection produces the least amount of additional losses at high blowing rates. Full-coverage film-cooling injection did not lead to marked variations in the blade pressure distribution and/or outlet flow angle.


2014 ◽  
Vol 136 (12) ◽  
Author(s):  
Silvia Ravelli ◽  
Giovanna Barigozzi

The main purpose of this numerical investigation is to overcome the limitations of the steady modeling in predicting the cooling efficiency over the cutback surface in a high pressure turbine nozzle guide vane. Since discrepancy between Reynolds-averaged Navier–Stokes (RANS) predictions and measured thermal coverage at the trailing edge was attributable to unsteadiness, Unsteady RANS (URANS) modeling was implemented to evaluate improvements in simulating the mixing between the mainstream and the coolant exiting the cutback slot. With the aim of reducing the computation effort, only a portion of the airfoil along the span was simulated at an exit Mach number of Ma2is = 0.2. Three values of the coolant-to-mainstream mass flow ratio were considered: MFR = 0.66%, 1.05%, and 1.44%. Nevertheless the inherent vortex shedding from the cutback lip was somehow captured by the URANS method, the computed mixing was not enough to reproduce the measured drop in adiabatic effectiveness η along the streamwise direction, over the cutback surface. So modeling was taken a step further by using the scale adaptive simulation (SAS) method at MFR = 1.05%. Results from the SAS approach were found to have potential to mimic the experimental measurements. Vortices shedding from the cutback lip were well predicted in shape and magnitude, but with a lower frequency, as compared to particle image velocimetry (PIV) data and flow visualizations. Moreover, the simulated reduction in film cooling effectiveness toward the trailing edge was similar to that observed experimentally.


2000 ◽  
Vol 123 (2) ◽  
pp. 258-265 ◽  
Author(s):  
D. A. Rowbury ◽  
M. L. G. Oldfield ◽  
G. D. Lock

An empirical means of predicting the discharge coefficients of film cooling holes in an operating engine has been developed. The method quantifies the influence of the major dimensionless parameters, namely hole geometry, pressure ratio across the hole, coolant Reynolds number, and the freestream Mach number. The method utilizes discharge coefficient data measured on both a first-stage high-pressure nozzle guide vane from a modern aero-engine and a scale (1.4 times) replica of the vane. The vane has over 300 film cooling holes, arranged in 14 rows. Data was collected for both vanes in the absence of external flow. These noncrossflow experiments were conducted in a pressurized vessel in order to cover the wide range of pressure ratios and coolant Reynolds numbers found in the engine. Regrettably, the proprietary nature of the data collected on the engine vane prevents its publication, although its input to the derived correlation is discussed. Experiments were also conducted using the replica vanes in an annular blowdown cascade which models the external flow patterns found in the engine. The coolant system used a heavy foreign gas (SF6 /Ar mixture) at ambient temperatures which allowed the coolant-to-mainstream density ratio and blowing parameters to be matched to engine values. These experiments matched the mainstream Reynolds and Mach numbers and the coolant Mach number to engine values, but the coolant Reynolds number was not engine representative (Rowbury, D. A., Oldfield, M. L. G., and Lock, G. D., 1997, “Engine-Representative Discharge Coefficients Measured in an Annular Nozzle Guide Vane Cascade,” ASME Paper No. 97-GT-99, International Gas Turbine and Aero-Engine Congress & Exhibition, Orlando, Florida, June 1997; Rowbury, D. A., Oldfield, M. L. G., Lock, G. D., and Dancer, S. N., 1998, “Scaling of Film Cooling Discharge Coefficient Measurements to Engine Conditions,” ASME Paper No. 98-GT-79, International Gas Turbine and Aero-Engine Congress & Exhibition, Stockholm, Sweden, June 1998). A correlation for discharge coefficients in the absence of external crossflow has been derived from this data and other published data. An additive loss coefficient method is subsequently applied to the cascade data in order to assess the effect of the external crossflow. The correlation is used successfully to reconstruct the experimental data. It is further validated by successfully predicting data published by other researchers. The work presented is of considerable value to gas turbine design engineers as it provides an improved means of predicting the discharge coefficients of engine film cooling holes.


2012 ◽  
Vol 134 (5) ◽  
Author(s):  
Giovanna Barigozzi ◽  
Antonio Perdichizzi ◽  
Silvia Ravelli

Tests on a specifically designed linear nozzle guide vane cascade with trailing edge coolant ejection were carried out to investigate the influence of trailing edge bleeding on both aerodynamic and thermal performance. The cascade is composed of six vanes with a profile typical of a high pressure turbine stage. The trailing edge cooling features a pressure side cutback with film cooling slots, stiffened by evenly spaced ribs in an inline configuration. Cooling air is ejected not only through the slots but also through two rows of cooling holes placed on the pressure side, upstream of the cutback. The cascade was tested for different isentropic exit Mach numbers, ranging from M2is = 0.2 to M2is = 0.6, while varying the coolant to mainstream mass flow ratio MFR up to 2.8%. The momentum boundary layer behavior at a location close to the trailing edge, on the pressure side, was assessed by means of laser Doppler measurements. Cases with and without coolant ejection allowed us to identify the contribution of the coolant to the off the wall velocity profile. Thermochromic liquid crystals (TLC) were used to map the adiabatic film cooling effectiveness on the pressure side cooled region. As expected, the cutback effect on cooling effectiveness, compared to the other cooling rows, was dominant.


2011 ◽  
Vol 110-116 ◽  
pp. 1047-1053
Author(s):  
Zhi Gang Liu ◽  
Xiang Jun Fang ◽  
Si Yong Liu ◽  
Ping Wang ◽  
Zhao Yin

A highly loaded high-pressure turbine with a supersonic nozzle guide vane and a transonic rotor for a Variable Cycle Engine (VCE) has been investigated. Film cooling strategies were designed for the whole stage, during which the positions, injection orientations and arrangements of cooling holes were confirmed. Three-dimensional steady numerical simulations have been performed in the two operation modes of low and high bypass ratio with different thermodynamic cycle parameters according to the VCE and the coolant injections have been simulated by means of additional source term method. The influences of coolant injections in the fully cooled turbine stage on aerodynamic performance and flow characteristics have been analyzed. The results indicate that, the supersonic nozzle guide vane, over-expansion degree of main flows, fluctuations of static pressure and intensity of corner vortex are lessened or alleviated. In the transonic rotor, expansion and doing work capabilities in the mixed fluid are strengthened. Proper coolants injections are beneficial to the flow characteristics in the blade passage.


Author(s):  
Lamyaa A. El-Gabry ◽  
Ranjan Saha ◽  
Jens Fridh ◽  
Torsten Fransson

An experimental study has been performed in a transonic annular sector cascade of nozzle guide vanes to investigate the aerodynamic performance and the interaction between hub film cooling and mainstream flow. The focus of the study is on the endwalls, specifically the interaction between the hub film cooling and the mainstream. Carbon dioxide (CO2) has been supplied to the coolant holes to serve as tracer gas. Measurements of CO2 concentration downstream of the vane trailing edge can be used to visualize the mixing of the coolant flow with the mainstream. Flow field measurements are performed in the downstream plane with a 5-hole probe to characterize the aerodynamics in the vane. Results are presented for the fully cooled and partially cooled vane (only hub cooling) configurations. Data presented at the downstream plane include concentration contour, axial vorticity, velocity vectors, and yaw and pitch angles. From these investigations, secondary flow structures such as the horseshoe vortex, passage vortex, can be identified and show the cooling flow significantly impacts the secondary flow and downstream flow field. The results suggest that there is a region on the pressure side of the vane trailing edge where the coolant concentrations are very low suggesting that the cooling air introduced at the platform upstream of the leading edge does not reach the pressure side endwall, potentially creating a local hotspot.


Author(s):  
Sean Jenkins ◽  
Krishnakumar Varadarajam ◽  
David G. Bogard

This paper presents the combined effects of high turbulence and film cooling on the dispersion of a simulated hot streak as it passes over a scaled-up nozzle guide vane. Experimental data demonstrates a considerable decay in the strength of a hot streak due to turbulence effects alone. Film cooling further reduces the peak temperature values resulting in a reduction of the peak temperature in the hot streak on the order of 75% relative to the upstream peak temperature in the hot streak. Comparisons are made between high turbulence (Tu = 20%) and moderate turbulence (Tu = 3.5%) as well as between different blowing conditions for the suction side, showerhead, and pressure side film cooling holes on a simulated nozzle guide vane.


Sign in / Sign up

Export Citation Format

Share Document