Modeling of a Smart Heat Pump Made of Laminated Thermoelectric and Electrocaloric Materials

2016 ◽  
Vol 138 (4) ◽  
Author(s):  
Dudong Feng ◽  
Shi-Chune Yao ◽  
Tian Zhang ◽  
Qiming Zhang

In this study, a smart heat pump, which could be used for the cooling of electronics, made of laminated structure of thermoelectric (TE) and electrocaloric (EC) materials, is studied. A simple arrangement of two TE layers sandwiched with one EC layer is modeled. This smart heat pump utilized the newly developed EC materials of giant adiabatic temperature change and the TE materials of high figure of merit. The system has the advantages of no moving parts, made of solid state, operable over large working temperature difference, and can be formed into very small size. The operation of the device is numerically modeled considering the three major parametric effects: EC operation as a function of time, electric current applied on TE, and temperature difference between the hot and cold sinks. The results on coefficient of performance (COP) and heat flow per unit area are discussed. This study is performed as an early attempt of analyzing the basic physical features of TE–EC–TE laminated structure heat pump and extends the understanding by further discussing the tradeoff between lower COP and larger overall temperature difference coverage in the TE/EC hybrid heat pump system with multilaminated structure.

Author(s):  
Dudong Feng ◽  
Shi-chune Yao ◽  
Tian Zhang ◽  
Qiming Zhang

In this study, a smart heat pump, which could be used for the cooling of electronics, made of the laminated structure of thermoelectric (TE) and electrocaloric (EC) materials is studied. A simple arrangement of two TE layers sandwiched with one EC layer is modeled. This smart heat pump utilized the newly developed EC materials of giant adiabatic temperature change and the TE materials of high figure of merit, which has the advantages of no moving parts, made of solid state, operable over large working temperature difference, and can be formed into very small size. The operation of the device is numerically modelled considering the three major parametric effects: EC operation as function of time, electric current applied on TE, and temperature difference between the hot and cold sinks. The results on Coefficient of Performance (COP) and heat flow per unit area are discussed. This study validates the feasibility of TE-EC-TE laminated structure heat pump, and extends the understanding by further discussing the performance of structures with more laminated layers.


1999 ◽  
Author(s):  
D. A. Kouremenos ◽  
E. D. Rogdakis ◽  
G. K. Alexis

Abstract Absorption system have been investigated for many years. However, coefficient of performance COP or heat gain factor HGF for absorption systems are significantly lower than those for conventional compression systems. This has restricted their wide application. This paper discusses the behavior of mixture NH3-H2O through of an ejector, operating in an absorption heat pump system. This combination improves the performance of conventional absorption system and with the phasing out of ozone-damaging refrigerants, absorption refrigerators, heat pumps and air-conditioning now provide a potential alternative. For the detailed calculation of the proposed system a method has been developed, which employs analytical functions describing the thermodynamic properties of die mixture. The influence of three major parameters: generator, condenser and evaporator temperature, on ejector efficiency and heat gain factor of the system is discussed. Also the maximum value of HGF was estimated by correlation of above three temperatures.


Author(s):  
Jeremy Spitzenberger ◽  
Pengtao Wang ◽  
Laith Ismael ◽  
Hongbin Ma ◽  
Ahmad Abuheiba ◽  
...  

Abstract Ejector driven systems have the ability to operate at high efficiencies, utilizing recycled thermal energy as a power source. For a typical ejector heat pump system, the increase of the condenser temperature reduces the coefficient of performance (COP). In addition, if the condenser temperature is higher than the critical temperature, the ejector may not function. In this situation, the condenser temperature must be reduced, and an additional heater will be utilized to heat the production water from the condenser temperature to the desired temperature. In this investigation, a single-stage gas-fired ejector heat pump (EHP) is investigated and thermodynamically modeled in order to optimize the system COP for the purpose of heating water by utilizing the thermal energy from the ambient air. The effects of the high-temperature evaporator (HTE) and low-temperature evaporator (LTE) temperatures on the ejector critical back pressure and the EHP system performance are examined for a HTE temperature range of 120-180 °C and LTE temperatures of 15.5, 17.5, and 19.5 °C. Results show that an optimized COP of the EHP system exists which depends on HTE and LTE temperatures, primary nozzle throat diameters. In addition, it is found that the EHP COP is independent of the ejector COP. From this investigation a maximum EHP COP of 1.31 is able to be achieved for a HTE temperature of 160 °C and a LTE temperature of 19.5 °C with a total heating capacity of 15.98 kW.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Akbar Alidadi Shamsabadi ◽  
Mehdi Jahangiri ◽  
Tayebeh Rezaei ◽  
Rouhollah Yadollahi Farsani ◽  
Ali Seryani ◽  
...  

Purpose In this study, a solar water heating system along with a seasonal thermal energy storage and a heat pump is designed for a villa with an area of 192 m2 in Tehran, the capital of Iran. Design/methodology/approach According to the material and the area of the residential space, the required heating of the building was calculated manually and then the thermodynamic analysis of the system and simulation was done in MATLAB software. Finally, regarding the waste of system, an efficient solar heating system, providing all the required energy to heat the building, was obtained. Findings The surface area of the solar collector is equal to 46 m2, the capacity of the tank is about 2,850 m3, insulation thickness stands at 55 cm and the coefficient of performance in required heat pump is accounted to about 9.02. Also, according to the assessments, the maximum level of received energy by the collector in this system occurs at a maximum temperature of 68ºC. Originality/value To the best of the authors’ knowledge, in the present work, for the first time, using mathematical modeling and analyzing of the first and second laws of thermodynamics, as well as using of computational code in MATLAB software environment, the solar-assisted ground source heat pump system is simulated in a residential unit located in Tehran.


2011 ◽  
Vol 374-377 ◽  
pp. 398-404 ◽  
Author(s):  
Ying Ning Hu ◽  
Ban Jun Peng ◽  
Shan Shan Hu ◽  
Jun Lin

A hot-water and air-conditioning (HWAC) combined ground sourse heat pump(GSHP) system with horizontal ground heat exchanger self-designed and actualized was presented in this paper. The heat transfer performance for the heat exchanger of two different pipe arrangements, three layers and four layers, respectively, was compared. It showed that the heat exchange quantity per pipe length for the pipe arrangement of three layers and four layers are 18.0 W/m and 15.0 W/m. The coefficient of performance (COP) of unit and system could remain 4.8 and 4.2 as GSHP system for heating water, and the COP of heating and cooling combination are up to 8.5 and 7.5, respectively. The power consumption of hot-water in a whole year is 9.0 kwh/t. The economy and feasibility analysis on vertical and horizontal ground heat exchanger were made, which showed that the investment cost per heat exchange quantity of horizontal ground heat exchanger is 51.4% lower than that of the vertical ground heat exchanger, but the occupied area of the former is 7 times larger than the latter's.


Energies ◽  
2018 ◽  
Vol 11 (10) ◽  
pp. 2642 ◽  
Author(s):  
Yi Zhang ◽  
Guanmin Zhang ◽  
Aiqun Zhang ◽  
Yinhan Jin ◽  
Ruirui Ru ◽  
...  

Frost layer on the outdoor air heat exchanger surface in an air-source heat pump (ASHP) can decrease the system coefficient of performance (COP). Although the common defrosting and anti-frosting methods can improve the COP, the periodic defrosting not only reduces the system energy efficiency but also deteriorates the indoor environment. To solve these problems, it is necessary to clearly understand the frosting phenomenon and to achieve the system frost-free operation. This paper focused firstly on the analyses of frosting pathways and frosting maps. Followed by summarizing the characteristics of frost-free technologies. And then the performances of two types of frost-free ASHP (FFASHP) systems were reviewed, and the exergy and economic analysis of a FFASHP heating system were carried out. Finally, the existing problems related to the FFASHP technologies were proposed. Results show that the existing frosting maps need to be further improved. The FFASHP systems can not only achieve continuous frost-free operation but reduce operating cost. And the total COP of the FFASHP heating system is approximately 30–64% higher than that of the conventional ASHP system under the same frosting conditions. However, the investment cost of the FFASHP system increases, and its reliability also needs further field test in a wider frosting environment. In the future, combined with a new frosting map, the control strategy for the FFASHP system should be optimized.


Energies ◽  
2020 ◽  
Vol 13 (17) ◽  
pp. 4498 ◽  
Author(s):  
Paolo Conti ◽  
Carlo Bartoli ◽  
Alessandro Franco ◽  
Daniele Testi

Estimating and optimizing the dynamic performance of a heat pump system coupled to a building is a paramount yet complex task, especially under intermittent conditions. This paper presents the “hardware-in-the-loop” experimental campaign of an air-source heat pump serving a typical dwelling in Pisa (Italy). The experimental apparatus uses real pieces of equipment, together with a thermal load emulator controlled by a full energy dynamic simulation of the considered building. Real weather data are continuously collected and used to run the simulation. The experimental campaign was performed from November 2019 to February 2020, measuring the system performances under real climate and load dynamics. With a water set point equal to 40 °C, the average heat pump coefficient of performance was about 3, while the overall building-plant performance was around 2. The deviation between the two performance indexes can be ascribed to the continuous on-off signals given by the zone thermostat due to the oversized capacity of the heat emission system. The overall performance raised to 2.5 thanks to a smoother operation obtained with reduced supply temperature (35 °C) and fan coil speed. The paper demonstrates the relevance of a dynamic analysis of the building-HVAC system and the potential of the “hardware-in-the-loop” approach in assessing actual part-load heat pump performances with respect to the standard stationary methodology.


2018 ◽  
Vol 3 (2) ◽  
pp. 58-61
Author(s):  
Agnieszka Lisowska-Lis ◽  
Robert Leszczyński

The subject of the research was an air-water heat pump, model PCUW 2.5kW from HEWALEX, installed in a single-family house. The pump is only used for heating water. The research was carried out from 25-08-2017 to 18-09-2017 in the village of Zborowice, in Malopolska region, Poland. The data were recorded from the heat pump system: temperature of the lower heat source (external air), temperature of the upper heat source (water temperature in the tank), time of heat pump was calculated during the analysed cycle of work and electrical energy consumption. The Coefficient Of Performance (COP) of the analysed air-water heat pump was determined. The analysis of the results was carried out using the MATLAB and EXCEL statistical tools. The correlation between COP coefficient and external air temperature is strong: 0.67.