Evaluation of Thermal Stratification Inside a New Model of Spherical Water Storage Tank Using a Computational Fluid Dynamics 6 Degrees of Freedom Solver

Author(s):  
Mohamed Taher Bouzaher ◽  
Belghar Noureddine ◽  
Charaf-Eddine Bensaci ◽  
Nora Bouchahm ◽  
Belhi Guerira

Abstract In this work, a computational analysis of a spherical solar hot water storage tank during the discharging process is carried out by using the commercial code ansys-fluent.15. The study investigates a new type of spherical heat storage tank. A hinged baffle is fixed at the tank vertical axis to increase the discharge flow rate without a thermocline layer. The dynamic mesh LAYERING technique is used to update the computational domain during the movement of the hinged baffle. The passive pitching of the submerged baffle is due to the fluid-dynamic loads. This model limits the mixture between hot and cold water regardless of the inlet flow rate. A comparative study between tanks with typical diffusers and the hinged baffle model is considered. The comparison of the computational fluid dynamics results with available experimental data showed a good agreement. Examinations of the temperature contours indicate that for the typical models, the interaction between the incoming cold water and the stored hot water gives rise to a thick thermocline layer where its temperature and thickness are related to the intensity of the mixing process. The suggested model shows high stratification efficiency along the discharging process.

2017 ◽  
Vol 28 (1) ◽  
pp. 76 ◽  
Author(s):  
G.D. Joubert ◽  
R.T. Dobson

The as-built and tested passive night-sky radiation cooling/heating system considered in this investigation consists of a radiation panel, a cold water storage tank, a hot water storage tank, a room and the interconnecting pipework. The stored cold water can be used to cool a room during the day, particularly in summer. A theoretical time-dependent thermal performance model was also developed and compared with the experimental results and it is shown that the theoretical simulation model captures the experimental system performance to within a reasonable degree of accuracy. A natural circulation experimental set-up was constructed and subsequently used to show that under local (Stellenbosch, South Africa) conditions the typical heat-removal rate from the water in the tank is 55 W/m2 of radiating panel during the night; during the day the water in the hot water-storage tank was heated from 24 °C to 62 °C at a rate of 96 W/m2. The system was also able to cool the room at a rate of 120 W/m3. The results thus confirmed that it is entirely plausible to design an entirely passive system, that is, without the use of any moving mechanical equipment such as pumps and active controls, for both room-cooling and water-heating. It is thus concluded that a passive night-sky radiation cooling/heating system is a viable energy-saving option and that the theoretical simulation, as presented, can be used with confidence as an energy-saving system design and evaluation tool. Keywords: passive cooling and heating, buoyancy-driven fluid flow, theoretical simulation, experimental verification Highlights:Passively driven renewable energy heating and cooling systems are considered.Time-dependent mathematical simulation model is presented.Experimental buoyancy-driven heating and cooling system built and tested.Experimental results demonstrate the applicability of the theoretical simulation model.Saving and evaluation design tool.


2015 ◽  
Vol 36 (3) ◽  
pp. 123-138 ◽  
Author(s):  
Marcin Wołowicz ◽  
Jakub Kupecki ◽  
Katarzyna Wawryniuk ◽  
Jarosław Milewski ◽  
Konrad Motyliński

Abstract The paper presents dynamic model of hot water storage tank. The literature review has been made. Analysis of effects of nodalization on the prediction error of generalized finite element method (GFEM) is provided. The model takes into account eleven various parameters, such as: flue gases volumetric flow rate to the spiral, inlet water temperature, outlet water flow rate, etc. Boiler is also described by sizing parameters, nozzle parameters and heat loss including ambient temperature. The model has been validated on existing data. Adequate laboratory experiments were provided. The comparison between 1-, 5-, 10- and 50-zone boiler is presented. Comparison between experiment and simulations for different zone numbers of the boiler model is presented on the plots. The reason of differences between experiment and simulation is explained.


Energies ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 4741
Author(s):  
María Gasque ◽  
Federico Ibáñez ◽  
Pablo González-Altozano

This paper demonstrates that it is possible to characterize the water temperature profile and its temporal trend in a hot water storage tank during the thermal charge process, using a minimum number of thermocouples (TC), with minor differences compared to experimental data. Four experimental tests (two types of inlet and two water flow rates) were conducted in a 950 L capacity tank. For each experimental test (with 12 TC), four models were developed using a decreasing number of TC (7, 4, 3 and 2, respectively). The results of the estimation of water temperature obtained with each of the four models were compared with those of a fifth model performed with 12 TC. All models were tested for constant inlet temperature. Very acceptable results were achieved (RMSE between 0.2065 °C and 0.8706 °C in models with 3 TC). The models were also useful to estimate the water temperature profile and the evolution of thermocline thickness even with only 3 TC (RMSE between 0.00247 °C and 0.00292 °C). A comparison with a CFD model was carried out to complete the study with very small differences between both approaches when applied to the estimation of the instantaneous temperature profile. The proposed methodology has proven to be very effective in estimating several of the temperature-based indices commonly employed to evaluate thermal stratification in water storage tanks, with only two or three experimental temperature data measurements. It can also be used as a complementary tool to other techniques such as the validation of numerical simulations or in cases where only a few experimental temperature values are available.


2020 ◽  
Vol 143 (1) ◽  
Author(s):  
Azzam Abu-Rayash ◽  
Ibrahim Dincer

Abstract This paper features the integration of two renewable energy sources, making a new trigeneration system for residential applications. The system is primarily powered by solar photovoltaic-thermal (PVT) along with geothermal energy. This trigeneration system consists of a ground source heat pump, solar system, high-grade and low-grade heat exchangers, a heat pump system, and a water storage tank (WST). The objective of this system is to provide the main commodities for residential use including domestic hot water (DHW), electricity, and space heating. The system is analyzed energetically and exergetically using thermodynamic-based concepts. The overall energy and exergy efficiencies of the proposed system are found to be 86.9% and 74.7%, respectively. In addition, the energy and exergy efficiencies of the PVT system are obtained to be 57.91% and 34.19%, respectively. The exergy destructions at the high-grade heat exchanger and the water storage tank add up to 36.9 kW, which makes up 80% of the total exergy destruction of the system. Additionally, parametric studies are conducted to evaluate the degree of impact that various important parameters have on the overall system performance.