Computational Modeling of Voice Production Using Excised Canine Larynx

Author(s):  
Weili Jiang ◽  
Charles Farbos De Luzan ◽  
Xiaojian Wang ◽  
Liran Oren ◽  
Sid Khosla ◽  
...  

Abstract A combined experimental-numerical work was conducted to comprehensively validate a subject-specific continuum model of voice production in larynx using excised canine laryngeal experiments. The computational model is a coupling of the Navier-Stokes equations for glottal flow dynamics and a finite element model of vocal fold dynamics. The numerical simulations employed a cover-body vocal fold structure with the geometry reconstructed from MRI scans and the material properties determined through an optimization-based inverse process of experimental indentation measurement. The results showed that the simulations predicted key features of the dynamics observed in the experiments, including the skewing of the glottal flow waveform, mucosal wave propagation, continuous increase of the divergent angle and intraglottal swirl strength during glottal closing, and flow recirculation between glottal jet and vocal fold. The simulations also predicted the increase of the divergent angle, glottal jet speed and intraglottal flow swirl strength with the subglottal pressure, same as in the experiments. Quantitatively, the simulations over-predicted the frequency and jet speed and under-predicted the flow rate and divergent angle for the larynx under study. The limitations of the model and their implications were discussed.

2021 ◽  
Vol 11 (3) ◽  
pp. 1221
Author(s):  
Dariush Bodaghi ◽  
Qian Xue ◽  
Xudong Zheng ◽  
Scott Thomson

An in-house 3D fluid–structure–acoustic interaction numerical solver was employed to investigate the effect of subglottic stenosis (SGS) on dynamics of glottal flow, vocal fold vibration and acoustics during voice production. The investigation focused on two SGS properties, including severity defined as the percentage of area reduction and location. The results show that SGS affects voice production only when its severity is beyond a threshold, which is at 75% for the glottal flow rate and acoustics, and at 90% for the vocal fold vibrations. Beyond the threshold, the flow rate, vocal fold vibration amplitude and vocal efficiency decrease rapidly with SGS severity, while the skewness quotient, vibration frequency, signal-to-noise ratio and vocal intensity decrease slightly, and the open quotient increases slightly. Changing the location of SGS shows no effect on the dynamics. Further analysis reveals that the effect of SGS on the dynamics is primarily due to its effect on the flow resistance in the entire airway, which is found to be related to the area ratio of glottis to SGS. Below the SGS severity of 75%, which corresponds to an area ratio of glottis to SGS of 0.1, changing the SGS severity only causes very small changes in the area ratio; therefore, its effect on the flow resistance and dynamics is very small. Beyond the SGS severity of 75%, increasing the SGS severity, leads to rapid increases of the area ratio, resulting in rapid changes in the flow resistance and dynamics.


2004 ◽  
Author(s):  
Michael Barry

The design and testing of an experimental apparatus for in vitro study of phonatory aerodynamics (voice production) in humans is presented. The presentation includes not only the details of apparatus design, but flow visualization and Digital Particle Image Velocimetry (DPIV) measurements of the developing flow that occurs during the opening of the constriction from complete closure. The main features of the phonation process have long been understood. A proper combination of air flow from the lungs and of vocal fold tension initiates a vibration of the vocal folds, which in turn valves the airflow. The resulting periodic acceleration of the airstream through the glottis excites the acoustic modes of the vocal tract. It is further understood that the pressure gradient driving glottal flow is related to flow separation on the downstream side of the vocal folds. However, the details of this process and how it may contribute to effects such as aperiodicity of the voice and energy losses in voiced sound production are still not fully grasped. The experimental apparatus described in this paper is designed to address these issues. The apparatus itself consists of a scaled-up duct in which water flows through a constriction whose width is modulated by motion of the duct wall in a manner mimicking vocal fold vibration. Scaling the duct up 10 times and using water as the working fluid allows temporally and spatially resolved measurements of the dynamically similar flow velocity field using DPIV at video standard framing rates (15Hz). Dynamic similarity is ensured by matching the Reynolds number (based on glottal flow speed and glottis width) of 8000, and by varying the Strouhal number (based on vocal fold length, glottal flow speed, and a time scale characterizing the motion of the vocal folds) ranging from 0.01 to 0.1. The walls of the 28 cm × 28 cm test section and the vocal fold pieces are made of clear cast acrylic to allow optical access. The vocal fold pieces are 12.7 cm × 14 cm × 28 cm and are rectangular in shape, except for the surfaces which form the glottis, which are 6.35 cm radius half-circles. Dye injection slots are placed on the upstream side of both vocal field pieces to allow flow visualization. Prescribed motion of the vocal folds is provided by two linear stages. Linear bearings ensure smooth execution of the motion prescribed using a computer interface. Measurements described here use the Laser-Induced Fluorescence (LIF) flow visualization and DPIV techniques and are performed for two Strouhal numbers to assess the effect of opening time on the development of the glottal jet. These measurements are conducted on a plane oriented perpendicular to the glottis, at the duct midplane. LIF measurements use a 5W Argon ion laser to produce a light sheet, which illuminates the dye injected through a slot in each vocal fold piece. Two dye colors are used, one for each side. Quantitative information about the velocity and vorticity fields are obtained through DPIV measurements at the same location as the LIF measurements.


2021 ◽  
Vol 15 (2) ◽  
Author(s):  
Petr Hájek ◽  
Pavel Švancara ◽  
Jaromír Horáček ◽  
Jan G. Švec

Finite-element modeling of self-sustained vocal fold oscillations during voice production has mostly considered the air as incompressible, due to numerical complexity. This study overcomes this limitation and studies the influence of air compressibility on phonatory pressures, flow and vocal fold vibratory characteristics. A two-dimensional finite-element model is used, which incorporates layered vocal fold structure, vocal fold collisions, large deformations of the vocal fold tissue, morphing the fluid mesh according to the vocal fold motion by the arbitrary Lagrangian-Eulerian approach and vocal tract model of Czech vowel [i:] based on data from magnetic resonance images. Unsteady viscous compressible or incompressible airflow is described by the Navier-Stokes equations. An explicit coupling scheme with separated solvers for structure and fluid domain was used for modeling the fluid-structure-acoustic interaction. Results of the simulations show clear differences in the glottal flow and vocal fold vibration waveforms between the incompressible and compressible fluid flow. These results provide the evidence on the existence of the coupling between the vocal tract acoustics and the glottal flow (Level 1 interactions), as well as between the vocal tract acoustics and the vocal fold vibrations (Level 2 interactions).


1988 ◽  
Vol 31 (3) ◽  
pp. 338-351 ◽  
Author(s):  
Martin Rothenberg ◽  
James J. Mahshie

A number of commercial devices for measuring the transverse electrical conductance of the thyroid cartilage produce waveforms that can be useful for monitoring movements within the larynx during voice production, especially movements that are closely related to the time-variation of the contact between the vocal folds as they vibrate. This paper compares the various approaches that can be used to apply such a device, usually referred to as an electroglottograph, to the problem of monitoring the time-variation of vocal fold abduction and adduction during voiced speech. One method, in which a measure of relative vocal fold abduction is derived from the duty cycle of the linear-phase high pass filtered electroglottograph waveform, is developed in detail.


Author(s):  
M. Vahdati ◽  
C. Breard ◽  
G. Simpson ◽  
M. Imregun

This paper will focus on core-compressor forced response with the aim to develop two design criteria, the so-called chordwise cumulative modal force and heightwise cumulative force, to assess the potential severity of the vibration levels from the correlation between the unsteady pressure distribution on the blade’s surface and the structural modeshape. It is also possible to rank various blade designs since the proposed criterion is sensitive to changes in both unsteady aerodynamic loads and the vibration modeshapes. The proposed methodology was applied to a typical core-compressor forced response case for which measured data were available. The Reynolds-averaged Navier-Stokes equations were used to represent the flow in a non-linear time-accurate fashion on unstructured meshes of mixed elements. The structural model was based on a standard finite element representation from which the vibration modes were extracted. The blade flexibility was included in the model by coupling the finite element model to the unsteady flow model in a time-accurate fashion. A series of numerical experiments were conducted by altering the stator wake and using the proposed indicator functions to minimize the rotor response levels. It was shown that a fourfold response reduction was possible for a certain mode with only a minor modification of the blade.


2016 ◽  
Vol 126 (11) ◽  
pp. 2534-2538 ◽  
Author(s):  
Liran Oren ◽  
Sid Khosla ◽  
Ephraim Gutmark
Keyword(s):  

Author(s):  
L. Hai ◽  
A. M. Al-Jumaily ◽  
A. Mirnajafi

The vibration characteristics of the vocal folds are investigated using a finite element model which incorporates the in-homogeneity and anisotropy of the materials and the irregularity of the geometry. The model employs the cover and body theory to build the structure of the vocal folds and implements measured viscoelastic properties of the mucosa and the transverse isotropic elastic properties of the muscles. It has the potential to simulate some vocal-fold disorders and determine the change in characteristics. To determine the oscillation characteristics of the folds, the eigenfrequency and eigenmodes of the finite element model are determined using the ABAQUS software. The model results compare well with some experiments performed on a silicon vocal fold. It is anticipated that the model will help to identify voice disorders such as vocal-fold paralysis and vocal-fold nodules.