scholarly journals The Influence of Blade Leaning on the Performance of an Integrated OGV-Diffuser System

Author(s):  
J. F. Carrotte ◽  
S. J. Stevens ◽  
A. P. Wray

An experimental investigation has been carried out to study the performance of an integrated design of compressor outlet guide vane and combustor pre-diffuser system. The trailing edge of each OGV was located within the outwardly canted diffuser by a distance equal to 27% of the diffuser axial length. In order to obtain representative inlet conditions a rotor, providing a fully sheared velocity profile and an air outlet angle of approximately 40°, was located upstream of the OGVs. Compared with the measured performance when the trailing edge of each OGV was located at diffuser inlet, a small increase in total pressure loss and a corresponding decrease in static pressure recovery was observed for the shortened system. This change in performance reflected a deterioration in the flow conditions along the outer wall, with transitory stalling of the flow being observed at diffuser exit. By leaning the blades in a circumferential direction through angles of 10° and 15° the outer wall flow conditions could be progressively improved, although at the largest angle tested stalling of the flow occurred at the hub of each OGV. However, at a lean angle of 10° the performance, in terms of loss and flow stability, could be virtually restored to the levels obtained when the trailing edge of each OGV was located radially at diffuser inlet.

Author(s):  
Daniel Burdett ◽  
Chris Hambidge ◽  
Thomas Povey

Accurate assessment of nozzle guide vane (NGV) capacity is essential for understanding engine performance data, and to achieve accurate turbine stage matching. In accelerated engine development programmes in particular, accurate and early assessment of NGV capacity is a significant advantage. Whilst the capabilities of computational methods have improved rapidly in recent years, the accuracy of absolute capacity prediction capability is lower than experimental techniques by some margin. Thus, experimental measurement of NGV capacity is still regarded as an essential part of many engine programmes. The semi-transient capacity measurement technique, developed and refined at the University of Oxford over the last 10 years, allows rapid and accurate measurement of engine component (typically fully cooled NGVs) capacity at engine-representative conditions of Mach and Reynolds numbers and coolant-to-mainstream pressure ratio. The technique has been demonstrated to offer considerable advantages over traditional (industrial steady-state) techniques in terms of accuracy, time and operating cost. Since the original facility was constructed, the facility has been modularised to allow for rapid interchange of test vane modules, and the instrumentation has been optimised to drive down the uncertainty in NGV capacity. In this paper, these improvements are described in detail, and a detailed uncertainty analysis is presented of the original facility, the current facility, and a proposed future facility in which the uncertainty of the measurement has been driven down to a practical limit. The bias errors of the three facilities are determined to be ±0.535%, ± 0.495% and ±0.301%, respectively (to 95% confidence). The corresponding precision uncertainties are ±0.028%, ±0.025% and ±0.025%, respectively. The extremely low precision uncertainty in particular allows very small changes in capacity to be resolved. This, combined with rapid interchangeability of test modules, allows studies of the sensitivity of capacity to secondary influences with much greater flexibility than was previously possible. Consideration is also given to the definition of vane capacity in systems with several streams at different conditions of inlet total pressure and temperature. A typical high pressure (HP) NGV has three distinct streams: a mainstream flow; coolant flow ejected from film cooling holes (distributed over the vane surface); and trailing edge coolant ejection. Whilst it is helpful for the coolant mass flow rates and inlet temperatures to be included in the definition, only a relatively small difference arises from the way in which this is achieved. Several definitions appear to share similar usefulness in terms of their robustness to changing inlet conditions of individual streams, but the favoured definition offers the possibility of isolating sensitivities to key effects such as trailing edge coolant ejection. This is achieved by explicitly expressing vane capacity as a function of two controlling pressure ratios. The overall purpose of this paper is to review and analyse in detail the current state-of-the-art in gas turbine flow capacity measurement.


Author(s):  
M. Pau ◽  
G. Paniagua

Ensuring an adequate life of high pressure turbines requires efficient cooling methods, such as rim seal flow ejection from the stator-rotor wheel space cavity interface, which prevents hot gas ingress into the rotor disk. The present work addresses the potential to improve the efficiency in transonic turbines at certain rim seal ejection rates. To understand this process a numerical study was carried out combining computational fluid dynamic simulations (CFD) and experiments on a single stage axial test turbine. The three dimensional steady CFD analysis was performed modeling the purge cavity flow ejected downstream of the stator blade row, at three flow regimes, subsonic M2 = 0.73, transonic M2 = 1.12 and supersonic M2 = 1.33. Experimental static pressure measurements were used to calibrate the computational model. The main flow field-purge flow interaction is found to be governed by the vane shock structures at the stator hub. The interaction between the vane shocks at the hub and the purge flow has been studied and quantitatively characterized as function of the purge ejection rate. The ejection of 1% of the core flow from the rim seal cavity leads to an increase of the hub static pressure of approximately 7% at the vane trailing edge. This local reduction of the stator exit Mach number decreases the trailing edge losses in the transonic regime. Finally, a numerically predicted loss breakdown is presented, focusing on the relative importance of the trailing edge losses, boundary layer losses, shock losses and mixing losses, as a function of the purge rate ejected. Contrary to the experience in subsonic turbines, results in a transonic model demonstrate that ejecting purge flow improves the vane efficiency due to the shock structures modification downstream of the stator.


Author(s):  
Sohail Hamid Zaidi ◽  
Robin L. Elder

A lightweight, high pressure radial inflow turbine was tested and laser anemometry used to measure the flow at various positions within the nozzle guide vanes, immediately upstream of the rotor and at two axial stations downstream of the rotor. The laser anemometry results indicated flow conditions within the nozzle vanes which were largely two dimensional (blade-to-blade with little hub to shroud variation) except at the vane outlet. Unsteadiness due to rotor blade passing effects were detected at the nozzle guide vane trailing edge but had almost entirely decayed at the vane throat. The results also indicate significant variations in flow conditions across the pitch of the nozzles suggesting incidence variations on the rotor of approaching 30 degrees. The laser anemometry results downstream of the turbine show a swirling flow characterised by a turbulent inner core region, a ‘centre annulus’ region of uniform velocity and flow direction and an outer flow region with a similar flow direction but velocity which increases rapidly towards the outer wall. The blade passing unsteadiness (blade-to-blade) is hardly noticeable some 50mm downstream of the rotor trailing edge.


2012 ◽  
Vol 135 (1) ◽  
Author(s):  
A. D. Walker ◽  
A. G. Barker ◽  
J. F. Carrotte ◽  
J. J. Bolger ◽  
M. J. Green

Within gas turbines the ability to design shorter aggressive S-shaped ducts is advantageous from a performance and weight saving perspective. However, current design philosophies tend to treat the S-shaped duct as an isolated component, neglecting the potential advantages of integrating the design with the upstream or downstream components. In this paper, such a design concept is numerically developed in which the upstream compressor outlet guide vanes are incorporated into the first bend of the S-shaped duct. Positioning the vane row within the first bend imparts a strong radial gradient to the pressure field within the vane passage. Tangential lean and axial sweep are employed such that the vane geometry is modified to exactly match the resulting inclined static pressure field. The integrated design is experimentally assessed and compared to a conventional nonintegrated design on a fully annular low speed test facility incorporating a single stage axial compressor. Several traverse planes are used to gather five-hole probe data which allow the flow structure to be examined through the rotor, outlet guide vane and within the transition ducts. The two designs employ almost identical duct geometry, but integration of the vane row reduces the system length by 21%. Due to successful matching of the static pressure field, the upstream influence of the integrated vane row is minimal and the rotor performance is unchanged. Similarly, the flow development within both S-shaped ducts is similar such that the circumferentially averaged profiles at duct exit are almost identical, and the operation of a downstream component would be unaffected. Overall system loss remains nominally unchanged despite the inclusion of lean and sweep and a reduction in system length. Finally, the numerical design predictions show good agreement with the experimental data thereby successfully validating the design process.


Author(s):  
A. D. Walker ◽  
A. G. Barker ◽  
J. F. Carrotte ◽  
J. J. Bolger ◽  
M. J. Green

Within gas turbines the ability to design shorter aggressive S-shaped ducts is advantageous from a performance and weight saving perspective. However, current design philosophies tend to treat the S-shaped duct as an isolated component, neglecting the potential advantages of integrating the design with the upstream or downstream components. In this paper such a design concept is numerically developed in which the upstream compressor outlet guide vanes are incorporated into the first bend of the S-shaped duct. Positioning the vane row within the first bend imparts a strong radial gradient to the pressure field within the vane passage. Tangential lean and axial sweep are employed such that the vane geometry is modified to exactly match the resulting inclined static pressure field. The integrated design is experimentally assessed and compared to a conventional non-integrated design on a fully annular low speed test facility incorporating a single stage axial compressor. Several traverse planes are used to gather five-hole probe data which allow the flow structure to be examined through the rotor, outlet guide vane and within the transition ducts. The two designs employ almost identical duct geometry, but integration of the vane row reduces the system length by 21%. Due to successful matching of the static pressure field, the upstream influence of the integrated vane row is minimal and the rotor performance is unchanged. Similarly the flow development within both S-shaped ducts is similar such that the circumferentially averaged profiles at duct exit are almost identical, and the operation of a downstream component would be unaffected. Overall system loss remains nominally unchanged despite the inclusion of lean and sweep and a reduction in system length. Finally, the numerical design predictions show good agreement with the experimental data thereby successfully validating the design process.


Author(s):  
A. G. Barker ◽  
J. F. Carrotte ◽  
C. W. Frodsham

An experimental investigation has been carried out to assess the aerodynamic effects of locating radial struts within the pre-diffuser of a modern combustor dump diffuser system. Engine representative inlet conditions were generated by a single stage rotor, with the diffuser system incorporating various compressor outlet guide vane (OGV)/pre-diffuser assemblies and an annular flame tube with representative porosity. Stagnation and static pressure measurements were obtained at numerous locations and included assessment of the upstream pressure field, associated with the struts, which impacts on the rotor and OGV aerodynamics. Measurements were also obtained within the feed annuli, surrounding the flame tube, with attempts also being made to assess the stagnation pressure distributions presented to a simulated flame tube burner. Initial tests were performed with an OGV row attached to a conventional 1.45 area ratio pre-diffuser, this providing the datum to which all other systems were assessed. These included systems with thin or thick struts with the strut blockage, at pre-diffuser exit, being 5% and 11% of the gas passage area respectively. For the geometries tested it was shown that the method of adjusting each pre-diffuser passage area, to account for the strut blockage, was successful in providing similar levels of reduced kinetic energy at pre-diffuser exit. Despite this, however, the presence of strut wakes and their effect on the dump cavity flow produced increases in stagnation pressure loss. These loss variations were evaluated for both the feed annuli and burner flows, with the magnitudes depending on whether the struts were aligned or midway between burners. Also assessed was the impact of the increased circumferential flow non-uniformity that was observed for the flow within the inner feed annulus. A beneficial effect produced by the struts was the significant reductions in flow swirl, within the diffuser system, relative to the datum. This improved axial alignment of the flow, provided a more uniform pressure distribution to the burners and a more stable feed to the various flame tube features.


Author(s):  
Marco Montis ◽  
Reinhard Niehuis ◽  
Mattia Guidi ◽  
Simone Salvadori ◽  
Francesco Martelli ◽  
...  

A series of tests on a specific designed linear nozzle guide vane (NGV) cascade with trailing edge coolant ejection was carried out to investigate the influence of the trailing edge bleeding (TEB) on the loss behaviour of the profile. Wake traverses with a five-hole probe and measurements of the pressure distribution on the profile were taken varying the ejection rate under reference main flow conditions, namely Re2th = 1.056·106 and Ma2th = 0.8 (Re2th based on the true chord). Wake total pressure losses and isentropic Mach number distributions on the profile were compared to measurements without coolant ejection, showing a significant influence of the TEB both on the wake development and on the flow in the vane passage. Numerical simulations of the experiments showed good agreement with the measured data and provided a deeper understanding of the flow phenomena, revealing the differences in the development of the wake with and without trailing edge coolant ejection and illustrating the blockage effect of the TEB on the flow in the vane passage.


2010 ◽  
Vol 132 (11) ◽  
Author(s):  
M. Pau ◽  
G. Paniagua

Ensuring an adequate life of high pressure turbines requires efficient cooling methods such as rim seal flow ejection from the stator-rotor wheel space cavity interface, which prevents hot gas ingress into the rotor disk. The present paper addresses the potential to improve the efficiency in transonic turbines at certain rim seal ejection rates. To understand this process, a numerical study was carried out, combining computational fluid dynamic (CFD) simulations and experiments on a single stage axial test turbine. The three dimensional steady CFD analysis was performed, modeling the purge cavity flow ejected downstream of the stator blade row at three flow regimes: subsonic M2=0.73, transonic M2=1.12, and supersonic M2=1.33. Experimental static pressure measurements were used to calibrate the computational model. The main flow field-purge flow interaction is found to be governed by the vane shock structures at the stator hub. The interaction between the vane shocks at the hub and the purge flow has been studied and quantitatively characterized as a function of the purge ejection rate. The ejection of 1% of the core flow from the rim seal cavity leads to an increase in the hub static pressure of approximately 7% at the vane trailing edge. This local reduction of the stator exit Mach number decreases the trailing edge losses in the transonic regime. Finally, a numerically predicted loss breakdown is presented, focusing on the relative importance of the trailing edge losses, boundary layer losses, shock losses, and mixing losses, as a function of the purge rate ejected. Contrary to the experience in subsonic turbines, results in a transonic model demonstrate that ejecting purge flow improves the vane efficiency due to the shock structure modification downstream of the stator.


2021 ◽  
Vol 9 (8) ◽  
pp. 831
Author(s):  
Zhuangzhuang Sun ◽  
Jie Yu ◽  
Fangping Tang

In order to study the influence of the position of the bulb on the hydraulic performance of asubmersible tubular pump device, based on a large-scale pumping station, two schemes—involving a front-mounted bulb and a rear-mounted bulb, respectively—were designed. The front-mounted scheme uses the GL-2008-03 hydraulic model and its conventional guide vane, while the rearmounted scheme uses the optimized design of a diffuser vane. The method of combining numerical simulation and experimental testing was used to analyze the differences between the external and internal characteristics of the two schemes. The results show that, under the condition of reasonable diffusion guide vane design, the efficiency under the rear-mounted scheme is higher than that under the front-mounted scheme, where the highest efficiency difference is about 1%. Although the frontmounted bulb scheme reduces the hydraulic loss of the bulb section, the placement of the bulb on the water inlet side reduces the flow conditions of the impeller. Affected by the circulation of the guide vane outlet, the hydraulic loss of the outlet channel is greater than the rear-mounted scheme. The bulb plays a rectifying function when the bulb is placed behind, which greatly eliminates the annular volume of the guide vane outlet, and the water outlet channel has a smaller hydraulic loss. In the front-mounted scheme, the water flow inside the outlet channel squeezes to the outer wall, causing higher entropy production near the outer wall area. The entropy production of the rear-mounted scheme is mainly in the bulb section and the bulb support. This research can provide reference for the design and form selection of a submersible tubular pump device, which has great engineering significance.


2013 ◽  
Vol 773 ◽  
pp. 749-754
Author(s):  
Zhen Ya Duan ◽  
Fu Lin Zheng ◽  
Hui Ling Shi ◽  
Jun Mei Zhang

In this paper, the numerical model of multi-stage liquid column scrubber was established. The flow field of liquid column scrubber with different inlet structure was respectively simulated by a commercial CFD code, Fluent. Considering the distribution characteristics of static pressure and velocity in the scrubber, this inlet type, single horizontal gas inlet with a notch at the bottom, is regarded as the most reasonable structure. On one hand, that structure has uniform distribution of static pressure. On the other hand, the velocity profile of its field presents saddle shape, i.e. the low central velocity exists between two peaks, which could contribute to weakening wall-flow phenomenon and obtaining uniform gas-liquid distribution.


Sign in / Sign up

Export Citation Format

Share Document