scholarly journals Next-Generation Integration Concepts for Air Separation Units and Gas Turbines

Author(s):  
Arthur R. Smith ◽  
Joseph Klosek ◽  
Donald W. Woodward

The commercialization of Integrated Gasification Combined Cycle (IGCC) power has been aided by concepts involving the integration of a cryogenic air separation unit (ASU) with the gas turbine combined-cycle module. Other processes, such as coal-based ironmaking and combined power/industrial gas production facilities, can also benefit from the integration. It is known and now widely accepted that an ASU designed for “elevated pressure” service and optimally integrated with the gas turbine can increase overall IGCC power output, increase overall efficiency, and decrease the net cost of power generation when compared to non-integrated facilities employing low pressure ASU’s. The specific gas turbine, gasification technology. NOx emission specification, and other site specific factors determine the optimal degree of compressed air and nitrogen stream integration. Continuing advancements in both air separation and gas turbine technologies offer new integration opportunities to improve performance and reduce costs. This paper reviews basic integration principles and describes next-generation concepts based on advanced high pressure ratio gas turbines, Humid Air Turbine (HAT) cycles and integration of compression heat and refrigeration sources from the ASU. Operability issues associated with integration are reviewed and control measures are described for the safe, efficient and reliable operation of these facilities.

1997 ◽  
Vol 119 (2) ◽  
pp. 298-304 ◽  
Author(s):  
A. R. Smith ◽  
J. Klosek ◽  
D. W. Woodward

The commercialization of Integrated Gasification Combined Cycle (IGCC) Power has been aided by concepts involving the integration of a cryogenic air separation unit (ASU) with the gas turbine combined-cycle module. Other processes, such as coal-based ironmaking and combined power/industrial gas production facilities, can also benefit from the integration. It is known and now widely accepted that an ASU designed for “elevated pressure” service and optimally integrated with the gas turbine can increase overall IGCC power output, increase overall efficiency, and decrease the net cost of power generation when compared to nonintegrated facilities employing low-pressure ASUs. The specific gas turbine, gasification technology, NOx emission specification, and other site specific factors determine the optimal degree of compressed air and nitrogen stream integration. Continuing advancements in both air separation and gas turbine technologies offer new integration opportunities to improve performance and reduce costs. This paper reviews basic integration principles and describes next-generation concepts based on advanced high pressure ratio gas turbines, Humid Air Turbine (HAT) cycles and integration of compression heat and refrigeration sources from the ASU. Operability issues associated with integration are reviewed and control measures are described for the safe, efficient, and reliable operation of these facilities.


Author(s):  
A. K. Anand ◽  
C. S. Cook ◽  
J. C. Corman ◽  
A. R. Smith

The application of gas turbine technology to IGCC systems requires careful consideration of the degree and type of integration used during the system design phase. Although gas turbines provide the primary output and efficiency gains for IGCC systems, as compared with conventional coal fired power generation systems, they are commercially available only in specific size ranges. Therefore, it is up to the IGCC system designer to optimize the IGCC power plant within the required output, efficiency and site conditions by selecting the system configuration carefully, particularly for air separation unit (ASU) integration incorporated with oxygen blown gasification systems. An IGCC system, based on a generic, entrained flow, oxygen blown gasification system and a GE STAG 109FA combined cycle has been evaluated with varying degrees of ASU integration, two fuel equivalent heating values and two gas turbine firing temperatures to provide net plant output and efficiency results. The data presented illustrate the system flexibility afforded by variation of ASU integration and the potential performance gains available through the continued use of gas turbine advances. Emphasis is place on system design choices which favor either low initial investment cost or low operating cost for a given IGCC system output.


1996 ◽  
Vol 118 (4) ◽  
pp. 732-736 ◽  
Author(s):  
A. K. Anand ◽  
C. S. Cook ◽  
J. C. Corman ◽  
A. R. Smith

The application of gas turbine technology to IGCC systems requires careful consideration of the degree and type of integration used during the system design phase. Although gas turbines provide the primary output and efficiency gains for IGCC systems, as compared with conventional coal-fired power generation systems, they are commercially available only in specific size ranges. Therefore, it is up to the IGCC system designer to optimize the IGCC power plant within the required output, efficiency, and site conditions by selecting the system configuration carefully, particularly for air separation unit (ASU) integration incorporated with oxygen blown gasification systems. An IGCC system, based on a generic, entrained flow, oxygen blown gasification system and a GE STAG 109FA combined cycle has been evaluated with varying degrees of ASU integration, two fuel equivalent heating values and two gas turbine firing temperatures to provide net plant output and efficiency results. The data presented illustrate the system flexibility afforded by variation of ASU integration and the potential performance gains available through the continued use of gas turbine advances. Emphasis is placed on system design choices that favor either low initial investment cost or low operating cost for a given IGCC system output.


Author(s):  
Satoshi Hada ◽  
Masanori Yuri ◽  
Junichiro Masada ◽  
Eisaku Ito ◽  
Keizo Tsukagoshi

MHI recently developed a 1600°C class J-type gas turbine, utilizing some of the technologies developed in the National Project to promote the development of component technology for the next generation 1700°C class gas turbine. This new frame is expected to achieve higher combined cycle efficiency and will contribute to reduce CO2 emissions. The target combined cycle efficiency of the J type gas turbine will be above 61.5% (gross, ISO standard condition, LHV) and the 1on1 combined cycle output will reach 460MW for 60Hz engine and 670MW for 50Hz engine. This new engine incorporates: 1) A high pressure ratio compressor based on the advanced M501H compressor, which was verified during the M501H development in 1999 and 2001. 2) Steam cooled combustor, which has accumulated extensive experience in the MHI G engine (> 1,356,000 actual operating hours). 3) State-of-art turbine designs developed through the 1700°C gas turbine component technology development program in Japanese National Project for high temperature components. This paper discusses the technical features and the updated status of the J-type gas turbine, especially the operating condition of the J-type gas turbine in the MHI demonstration plant, T-Point. The trial operation of the first M501J gas turbine was started at T-point in February 2011 on schedule, and major milestones of the trial operation have been met. After the trial operation, the first commercial operation has taken place as scheduled under a predominantly Daily-Start-and-Stop (DSS) mode. Afterward, MHI performed the major inspection in October 2011 in order to check the mechanical condition, and confirmed that the hot parts and other parts were in sound condition.


1983 ◽  
Vol 105 (4) ◽  
pp. 844-850 ◽  
Author(s):  
I. G. Rice

High-cycle pressure-ratio (38–42) gas turbines being developed for future aircraft and, in turn, industrial applications impose more critical disk and casing cooling and thermal-expansion problems. Additional attention, therefore, is being focused on cooling and the proper selection of materials. Associated blade-tip clearance control of the high-pressure compressor and high-temperature turbine is critical for high performance. This paper relates to the use of extracted steam from a steam turbine as a coolant in a combined cycle to enhance material selection and to control expansion in such a manner that the cooling process increases combined-cycle efficiency, gas turbine output, and steam turbine output.


2013 ◽  
Vol 34 (4) ◽  
pp. 137-159 ◽  
Author(s):  
Łukasz Bartela ◽  
Janusz Kotowicz

Abstract In the paper the results of analysis of an integrated gasification combined cycle IGCC polygeneration system, of which the task is to produce both electricity and synthesis gas, are shown. Assuming the structure of the system and the power rating of a combined cycle, the consumption of the synthesis gas for chemical production makes it necessary to supplement the lack of synthesis gas used for electricity production with the natural gas. As a result a change of the composition of the fuel gas supplied to the gas turbine occurs. In the paper the influence of the change of gas composition on the gas turbine characteristics is shown. In the calculations of the gas turbine the own computational algorithm was used. During the study the influence of the change of composition of gaseous fuel on the characteristic quantities was examined. The calculations were realized for different cases of cooling of the gas turbine expander’s blades (constant cooling air mass flow, constant cooling air index, constant temperature of blade material). Subsequently, the influence of the degree of integration of the gas turbine with the air separation unit on the main characteristics was analyzed.


2005 ◽  
Vol 127 (2) ◽  
pp. 369-374 ◽  
Author(s):  
Y. Fukuizumi ◽  
J. Masada ◽  
V. Kallianpur ◽  
Y. Iwasaki

Mitsubishi completed design development and verification load testing of a steam-cooled M501H gas turbine at a combined cycle power plant at Takasago, Japan in 2001. Several advanced technologies were specifically developed in addition to the steam-cooled components consisting of the combustor, turbine blades, vanes, and the rotor. Some of the other key technologies consisted of an advanced compressor with a pressure ratio of 25:1, active clearance control, and advanced seal technology. Prior to the M501H, Mitsubishi introduced cooling-steam in “G series” gas turbines in 1997 to cool combustor liners. Recently, some of the advanced design technologies from the M501H gas turbine were applied to the G series gas turbine resulting in significant improvement in output and thermal efficiency. A noteworthy aspect of the technology transfer is that the upgraded G series M701G2 gas turbine has an almost equivalent output and thermal efficiency as H class gas turbines while continuing to rely on conventional air cooling of turbine blades and vanes, and time-proven materials from industrial gas turbine experience. In this paper we describe the key design features of the M701G2 gas turbine that make this possible such as the advanced 21:1 compressor with 14 stages, an advanced premix DLN combustor, etc., as well as shop load test results that were completed in 2002 at Mitsubishi’s in-house facility.


Author(s):  
Geoff Myers ◽  
Dan Tegel ◽  
Markus Feigl ◽  
Fred Setzer ◽  
William Bechtel ◽  
...  

The lean, premixed DLN2.5H combustion system was designed to deliver low NOx emissions from 50% to 100% load in both the Frame 7H (60 Hz) and Frame 9H (50 Hz) heavy-duty industrial gas turbines. The H machines employ steam cooling in the gas turbine, a 23:1 pressure ratio, and are fired at 1440 C (2600 F) to deliver over-all thermal efficiency for the combined-cycle system near 60%. The DLN2.5H combustor is a modular can-type design, with 14 identical chambers used on the 9H machine, and 12 used on the smaller 7H. On a 9H combined-cycle power plant, both the gas turbine and steam turbine are fired using the 14-chamber DLN2.5H combustion system. An extensive full-scale, full-pressure rig test program developed the fuel-staged dry, low emissions combustion system over a period of more than five years. Rig testing required test stand inlet conditions of over 50 kg/s at 500 C and 28 bar, while firing at up to 1440 C, to simulate combustor operation at base load. The combustion test rig simulated gas path geometry from the discharge of the annular tri-passage diffuser through the can-type combustion liner and transition piece, to the inlet of the first stage turbine nozzle. The present paper describes the combustion system, and reports emissions performance and operability results over the gas turbine load and ambient temperature operating range, as measured during the rig test program.


1983 ◽  
Vol 105 (4) ◽  
pp. 821-825 ◽  
Author(s):  
J. Wolf ◽  
S. Moskowitz

Studies of combined cycle electic power plants have shown that increasing the firing temperature and pressure ratio of the gas turbine can substantially improve the specific power output of the gas turbine as well as the combined cycle plant efficiency. Clearly this is a direction in which we can proceed to conserve the world’s dwindling petroleum fuel supplies. Furthermore, tomorrow’s gas turbines must do more than operate at higher temperature; they will likely face an aggressive hot gas stream created by the combustion of heavier oils or coal-derived liquid or gaseous fuels. Extensive tests have been performed on two rotating turbine rigs, each with a transpiration air cooled turbine operating in the 2600 to 3000°F (1427 to 1649°C) temperature range at increasing levels of gas stream particulates and alkali metal salts to simulate operation on coal-derived fuel. Transpiration air cooling was shown to be effective in maintaining acceptable metal temperatures, and there was no evidence of corrosion, erosion, or deposition. The rate of transpiration skin cooling flow capacity exhibited a minor loss in the initial exposure to the particulate laden gas stream of less than 100 hours, but the flow reduction was commensurate with that produced by normal oxidation of the skin material at the operating temperatures of 1350°F (732°C). The data on skin permeability loss from both cascade and engine tests compared favorably with laboratory furnace oxidation skin specimens. To date, over 10,000 hr of furnace exposure has been conducted. Extrapolation of the data to 50,000 hr indicates the flow capacity loss would produce an acceptable 50°F (10°C) increase in skin operating temperature.


Sign in / Sign up

Export Citation Format

Share Document