Gas Turbine Power Boosting: Evaporative Cooling

Author(s):  
S. Brusca ◽  
R. Lanzafame

It is well known that gas turbines performance depend on ambient conditions. In particular, power production decreases when ambient temperature increases. It is possible to restore standard performance while running at critical temperatures using a power boosting technique such as evaporative cooling. The present paper deals with analysis of gas turbines power boosting by means of an evaporative cooling technique. In order to study the impact of the technique on gas turbine performance, a mathematical model of a General Electric MS6001FA gas turbine has been implemented using GateCycle software. The mathematical model was calibrated and tested using real gas turbine data for different running conditions. Test results show that the model is able to simulate engine behavior in all considered conditions with low errors. Parametric analysis in function of ambient conditions at maximum load was carried out. It was imposed a specific value of artificial air humidity using real ambient temperature and pressure. Thus, performance analysis of gas turbine running was carried out.

1990 ◽  
Vol 112 (4) ◽  
pp. 590-596 ◽  
Author(s):  
A. A. El Hadik

In a hot summer climate, as in Kuwait and other Arabian Gulf countries, the performance of a gas turbine deteriorates drastically during the high-temperature hours (up to 60°C in Kuwait). Power demand is the highest at these times. This necessitates an increase in installed gas turbine capacities to balance this deterioration. Gas turbines users are becoming aware of this problem as they depend more on gas turbines to satisfy their power needs and process heat for desalination due to the recent technical and economical development of gas turbines. This paper is devoted to studying the impact of atmospheric conditions, such as ambient temperature, pressure, and relative humidity on gas turbine performance. The reason for considering air pressures different from standard atmospheric pressure at the compressor inlet is the variation of this pressure with altitude. The results of this study can be generalized to include the cases of flights at high altitudes. A fully interactive computer program based on the derived governing equations is developed. The effects of typical variations of atmospheric conditions on power output and efficiency are considered. These include ambient temperature (range from −20 to 60°C), altitude (range from zero to 2000 m above sea level), and relative humidity (range from zero to 100 percent). The thermal efficiency and specific net work of a gas turbine were calculated at different values of maximum turbine inlet temperature (TIT) and variable environmental conditions. The value of TIT is a design factor that depends on the material specifications and the fuel/air ratio. Typical operating values of TIT in modern gas turbines were chosen for this study: 1000, 1200, 1400, and 1600 K. Both partial and full loads were considered in the analysis. Finally the calculated results were compared with actual gas turbine data supplied by manufacturers.


Author(s):  
K. Mathioudakis ◽  
A. Tsalavoutas

The paper presents an analysis of the effect of ambient humidity on the performance of industrial gas turbines and examines the impact of humidity on methods used for engine condition assessment and fault diagnostics. First, the way of incorporating the effect of humidity into a computer model of gas turbine performance is described. The model is then used to derive parameters indicative of the “health” of a gas turbine and thus diagnose the presence of deterioration or faults. The impact of humidity magnitude on the values of these health parameters is studied and the uncertainty introduced, if humidity is not taken into account, is assessed. It is shown that the magnitude of the effect of humidity depends on ambient conditions and is more severe for higher ambient temperatures. Data from an industrial gas turbine are presented to demonstrate these effects and to show that if humidity is appropriately taken into account, the uncertainty in the estimation of health parameters is reduced


Author(s):  
Sepehr Sanaye ◽  
Abbasali Farhad ◽  
Mohsen Ebrahimi

The ambient conditions (temperature, pressure and humidity) affect the gas turbine power output and thermal efficiency [1–8]. Increasing one Celsius degree of ambient temperature decreases the power output for about 0.5 to 0.9 percent and the thermal efficiency for about 0.25 percent. Evaporating cooling is efficient and cost effective method for gas turbine inlet cooling to improve the power output and efficiency, specially in hot and dry regions. A systematic thermo-economic evaluation of the three evaporative inlet cooling methods applied to existing 25 MW Fiat gas turbine in Ray power plant, is presented in this paper. The three inlet cooling methods considered are: evaporative inlet fogging, media type evaporative cooling and inlet cooling through air washer. The investment and maintenance costs, the income from increasing the power output, the costs of increasing fuel consumption, and power loss due to pressure drops, were estimated and the payback periods for the mentioned evaporative inlet cooling methods were obtained and compared. The suitable evaporative cooling method for various operational conditions is proposed for 25 MW Fiat gas turbines.


2002 ◽  
Vol 124 (4) ◽  
pp. 801-808 ◽  
Author(s):  
K. Mathioudakis ◽  
T. Tsalavoutas

The paper presents an analysis of the effect of ambient humidity on the performance of industrial gas turbines and examines the impact of humidity on methods used for engine condition assessment and fault diagnostics. First, the way of incorporating the effect of humidity into a computer model of gas turbine performance is described. The model is then used to derive parameters indicative of the “health” of a gas turbine and thus diagnose the presence of deterioration or faults. The impact of humidity magnitude on the values of these health parameters is studied and the uncertainty introduced, if humidity is not taken into account, is assessed. It is shown that the magnitude of the effect of humidity depends on ambient conditions and is more severe for higher ambient temperatures. Data from an industrial gas turbine are presented to demonstrate these effects and to show that if humidity is appropriately taken into account, the uncertainty in the estimation of health parameters is reduced.


Energies ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1382
Author(s):  
Obida Zeitoun

Gas turbine inlet air-cooling (TIAC) is an established technology for augmenting gas turbine output and efficiency, especially in hot regions. TIAC using evaporative cooling is suitable for hot, dry regions; however, the cooling is limited by the ambient wet-bulb temperature. This study investigates two-stage evaporative TIAC under the harsh weather of Riyadh city. The two-stage evaporative TIAC system consists of indirect and direct evaporative stages. In the indirect stage, air is precooled using water cooled in a cooling tower. In the direct stage, adiabatic saturation cools the air. This investigation was conducted for the GE 7001EA gas turbine model. Thermoflex software was used to simulate the GE 7001EA gas turbine using different TIAC systems including evaporative, two-stage evaporative, hybrid absorption refrigeration evaporative and hybrid vapor-compression refrigeration evaporative cooling systems. Comparisons of different performance parameters of gas turbines were conducted. The added annual profit and payback period were estimated for different TIAC systems.


Energies ◽  
2018 ◽  
Vol 11 (12) ◽  
pp. 3521 ◽  
Author(s):  
Panagiotis Stathopoulos

Conventional gas turbines are approaching their efficiency limits and performance gains are becoming increasingly difficult to achieve. Pressure Gain Combustion (PGC) has emerged as a very promising technology in this respect, due to the higher thermal efficiency of the respective ideal gas turbine thermodynamic cycles. Up to date, only very simplified models of open cycle gas turbines with pressure gain combustion have been considered. However, the integration of a fundamentally different combustion technology will be inherently connected with additional losses. Entropy generation in the combustion process, combustor inlet pressure loss (a central issue for pressure gain combustors), and the impact of PGC on the secondary air system (especially blade cooling) are all very important parameters that have been neglected. The current work uses the Humphrey cycle in an attempt to address all these issues in order to provide gas turbine component designers with benchmark efficiency values for individual components of gas turbines with PGC. The analysis concludes with some recommendations for the best strategy to integrate turbine expanders with PGC combustors. This is done from a purely thermodynamic point of view, again with the goal to deliver design benchmark values for a more realistic interpretation of the cycle.


Author(s):  
Rainer Kurz ◽  
Grant Musgrove ◽  
Klaus Brun

Fouling of compressor blades is an important mechanism leading to performance deterioration in gas turbines over time. Experimental and simulation data are available for the impact of specified amounts of fouling on performance, as well as the amount of foulants entering the engine for defined air filtration systems and ambient conditions. This study provides experimental data on the amount of foulants in the air that actually stick to a blade surface for different conditions of the blade surface. Quantitative results both indicate the amount of dust as well as the distribution of dust on the airfoil, for a dry airfoil, as well as airfoils that were wet from ingested water, as well as different types of oil. The retention patterns are correlated with the boundary layer shear stress. The tests show the higher dust retention from wet surfaces compared to dry surfaces. They also provide information about the behavior of the particles after they impact on the blade surface, showing that for a certain amount of wet film thickness, the shear forces actually wash the dust downstream, and off the airfoil. Further, the effect of particle agglomeration of particles to form larger clusters was observed, which would explain the disproportional impact of very small particles on boundary layer losses.


2021 ◽  
Author(s):  
Senthil Krishnababu ◽  
Omar Valero ◽  
Roger Wells

Abstract Data driven technologies are revolutionising the engineering sector by providing new ways of performing day to day tasks through the life cycle of a product as it progresses through manufacture, to build, qualification test, field operation and maintenance. Significant increase in data transfer speeds combined with cost effective data storage, and ever-increasing computational power provide the building blocks that enable companies to adopt data driven technologies such as data analytics, IOT and machine learning. Improved business operational efficiency and more responsive customer support provide the incentives for business investment. Digital twins, that leverages these technologies in their various forms to converge physics and data driven models, are therefore being widely adopted. A high-fidelity multi-physics digital twin, HFDT, that digitally replicates a gas turbine as it is built based on part and build data using advanced component and assembly models is introduced. The HFDT, among other benefits enables data driven assessments to be carried out during manufacture and assembly for each turbine allowing these processes to be optimised and the impact of variability or process change to be readily evaluated. On delivery of the turbine and its associated HFDT to the service support team the HFDT supports the evaluation of in-service performance deteriorations, the impact of field interventions and repair and the changes in operating characteristics resulting from overhaul and turbine upgrade. Thus, creating a cradle to grave physics and data driven twin of the gas turbine asset. In this paper, one branch of HFDT using a power turbine module is firstly presented. This involves simultaneous modelling of gas path and solid using high fidelity CFD and FEA which converts the cold geometry to hot running conditions to assess the impact of various manufacturing and build variabilities. It is shown this process can be executed within reasonable time frames enabling creation of HFDT for each turbine during manufacture and assembly and for this to be transferred to the service team for deployment during field operations. Following this, it is shown how data driven technologies are used in conjunction with the HFDT to improve predictions of engine performance from early build information. The example shown, shows how a higher degree of confidence is achieved through the development of an artificial neural network of the compressor tip gap feature and its effect on overall compressor efficiency.


2015 ◽  
Vol 22 (4) ◽  
pp. 53-58 ◽  
Author(s):  
Zygfryd Domachowski ◽  
Marek Dzida

Abstract The use of inlet air fogging installation to boost the power for gas turbine engines is widely applied in the power generation sector. The application of fogging to mechanical drive is rarely considered in literature [1]. This paper will cover some considerations relating to its application for gas turbines in ship drive. There is an important evaporative cooling potential throughout the world, when the dynamic data is evaluated, based on an analysis of coincident wet and dry bulb information. This data will allow ships’ gas turbine operators to make an assessment of the economics of evaporative fogging. The paper represents an introduction to the methodology and data analysis to derive the direct evaporative cooling potential to be used in marine gas turbine power output loss compensation.


2002 ◽  
Vol 128 (3) ◽  
pp. 506-517 ◽  
Author(s):  
S. M. Camporeale ◽  
B. Fortunato ◽  
M. Mastrovito

A high-fidelity real-time simulation code based on a lumped, nonlinear representation of gas turbine components is presented. The code is a general-purpose simulation software environment useful for setting up and testing control equipments. The mathematical model and the numerical procedure are specially developed in order to efficiently solve the set of algebraic and ordinary differential equations that describe the dynamic behavior of gas turbine engines. For high-fidelity purposes, the mathematical model takes into account the actual composition of the working gases and the variation of the specific heats with the temperature, including a stage-by-stage model of the air-cooled expansion. The paper presents the model and the adopted solver procedure. The code, developed in Matlab-Simulink using an object-oriented approach, is flexible and can be easily adapted to any kind of plant configuration. Simulation tests of the transients after load rejection have been carried out for a single-shaft heavy-duty gas turbine and a double-shaft aero-derivative industrial engine. Time plots of the main variables that describe the gas turbine dynamic behavior are shown and the results regarding the computational time per time step are discussed.