Experimental and Numerical Investigations of Low-Swirl Multi-Nozzle Combustion in a Lean Premixed Combustor

Author(s):  
Weijie Liu ◽  
Bing Ge ◽  
Yinshen Tian ◽  
Yongwen Yuan ◽  
Shusheng Zang ◽  
...  

This paper presents large-eddy simulations (LES) and laser diagnostic experiments of low-swirl lean premixed methane/air flames in a multi-nozzle combustor including five nozzles with the same structure. OH Planar Laser Induced Fluorescence (PLIF) is used to observe flame shapes and identify main reaction zones. NOx and CO emissions are also recorded during the experiment. The flows and flames are studied at different equivalence ratios ranging from 0.5 to 0.8, while the inlet velocity is fixed at 6.2 m/s. Results show that the neighboring swirling flows interact with each other, generating a highly turbulent mixing zone where intensive reactions take place. The flame is stabilized above the nozzle rim and its liftoff height decreases with increasing equivalence ratio. The center flow is confined and distorted by the neighboring flows, resulting in instabilities of the center flame. Mean OH radical images reveals that the center nozzle flame is extinguished when equivalence ratio is equals to 0.5, which is successfully predicted by LES. In addition, NOx emissions show log-linear dependency on the adiabatic flame temperature, while the CO emissions remain lower than 10 ppm. NOx emissions for multi-nozzle flame are less sensitive to the flame temperature than that for single nozzle. These results demonstrate that the low-swirl multi-nozzle concept is a promising solution to achieve stable combustion with ultra-low emissions in gas turbines.

Author(s):  
Thoralf G. Reichel ◽  
Steffen Terhaar ◽  
Oliver Paschereit

Since lean premixed combustion allows for fuel-efficiency and low emissions, it is nowadays state of the art in stationary gas turbines. In the long term, it is also a promising approach for aero engines, when safety issues like lean blowout (LBO) and flame flashback in the premixer can be overcome. While for the use of hydrogen the LBO limits are extended, the flashback propensity is increased. Thus, axial air injection is applied in order to eliminate flashback in a swirl-stabilized combustor burning premixed hydrogen. Axial injection constitutes a non-swirling jet on the central axis of the radial swirl generator which influences the vortex breakdown position. In the present work changes in the flow field and their impact on flashback limits of a model combustor are evaluated. First, a parametric study is conducted under isothermal test conditions in a water tunnel employing particle image velocimetry (PIV). The varied parameters are the amount of axially injected air and swirl number. Subsequently, flashback safety is evaluated in the presence of axial air injection in an atmospheric combustor test rig and a stability map is recorded. The flame structure is measured using high-speed OH* chemiluminescence imaging. Simultaneous high-speed PIV measurements of the reacting flow provide insight in the time-resolved reacting flow field and indicate the flame location by evaluating the Mie scattering of the raw PIV images by the means of the Qualitative Light Sheet (QLS) technique. The isothermal tests identify the potential of axial air injection to overcome the axial velocity deficits at the nozzle outlet, which is considered crucial in order to provide flashback safety. This effect of axial air injection is shown to prevail in the presence of a flame. Generally, flashback safety is shown to benefit from an elevated amount of axial air injection and a lower swirl number. Note, that the latter also leads to increased NOx emissions, while axial air injection does not. Additionally, fuel momentum is indicated to positively influence flashback resistance, although based on a different mechanism, an explanation of which is suggested. In summary, flashback-proof operation of the burner with a high amount of axial air injection is achieved on the whole operating range of the test rig at inlet temperatures of 620 K and up to stoichiometric conditions while maintaining single digit NOx emissions below a flame temperature of 2000 K.


Author(s):  
Thoralf G. Reichel ◽  
Steffen Terhaar ◽  
Oliver Paschereit

Since lean premixed combustion allows for fuel-efficiency and low emissions, it is nowadays state of the art in stationary gas turbines. In the long term, it is also a promising approach for aero engines, when safety issues like lean blowout (LBO) and flame flashback in the premixer can be overcome. While for the use of hydrogen the LBO limits are extended, the flashback propensity is increased. Thus, axial air injection is applied in order to eliminate flashback in a swirl-stabilized combustor burning premixed hydrogen. Axial injection constitutes a nonswirling jet on the central axis of the radial swirl generator which influences the vortex breakdown (VB) position. In the present work, changes in the flow field and their impact on flashback limits of a model combustor are evaluated. First, a parametric study is conducted under isothermal test conditions in a water tunnel employing particle image velocimetry (PIV). The varied parameters are the amount of axially injected air and swirl number. Subsequently, flashback safety is evaluated in the presence of axial air injection in an atmospheric combustor test rig and a stability map is recorded. The flame structure is measured using high-speed OH* chemiluminescence imaging. Simultaneous high-speed PIV measurements of the reacting flow provide insight in the time-resolved reacting flow field and indicate the flame location by evaluating the Mie scattering of the raw PIV images by means of the qualitative light sheet (QLS) technique. The isothermal tests identify the potential of axial air injection to overcome the axial velocity deficits at the nozzle outlet, which is considered crucial in order to provide flashback safety. This effect of axial air injection is shown to prevail in the presence of a flame. Generally, flashback safety is shown to benefit from an elevated amount of axial air injection and a lower swirl number. Note that the latter also leads to increased NOx emissions, while axial air injection does not. Additionally, fuel momentum is indicated to positively influence flashback resistance, although based on a different mechanism, an explanation of which is suggested. In summary, flashback-proof operation of the burner with a high amount of axial air injection is achieved on the whole operating range of the test rig at inlet temperatures of 620 K and up to stoichiometric conditions while maintaining single digit NOx emissions below a flame temperature of 2000 K.


Author(s):  
P. Griebel ◽  
R. Bombach ◽  
A. Inauen ◽  
R. Scha¨ren ◽  
S. Schenker ◽  
...  

The present experimental study focuses on flame characteristics and turbulent flame speeds of lean premixed flames typical for stationary gas turbines. Measurements were performed in a generic combustor at a preheating temperature of 673 K, pressures up to 14.4 bars (absolute), a bulk velocity of 40 m/s, and an equivalence ratio in the range of 0.43–0.56. Turbulence intensities and integral length scales were measured in an isothermal flow field with Particle Image Velocimetry (PIV). The turbulence intensity (u′) and the integral length scale (LT) at the combustor inlet were varied using turbulence grids with different blockage ratios and different hole diameters. The position, shape, and fluctuation of the flame front were characterized by a statistical analysis of Planar Laser Induced Fluorescence images of the OH radical (OH-PLIF). Turbulent flame speeds were calculated and their dependence on operating conditions (p, φ) and turbulence quantities (u′, LT) are discussed and compared to correlations from literature. No influence of pressure on the most probable flame front position or on the turbulent flame speed was observed. As expected, the equivalence ratio had a strong influence on the most probable flame front position, the spatial flame front fluctuation, and the turbulent flame speed. Decreasing the equivalence ratio results in a shift of the flame front position farther downstream due to the lower fuel concentration and the lower adiabatic flame temperature and subsequently lower turbulent flame speed. Flames operated at leaner equivalence ratios show a broader spatial fluctuation as the lean blow-out limit is approached and therefore are more susceptible to flow disturbances. In addition, because of a lower turbulent flame speed these flames stabilize farther downstream in a region with higher velocity fluctuations. This increases the fluctuation of the flame front. Flames with higher turbulence quantities (u′, LT) in the vicinity of the combustor inlet exhibited a shorter length and a higher calculated flame speed. An enhanced turbulent heat and mass transport from the recirculation zone to the flame root location due to an intensified mixing which might increase the preheating temperature or the radical concentration is believed to be the reason for that.


2021 ◽  
Author(s):  
Fujun Sun ◽  
Jianqin Suo ◽  
Zhenxia Liu

Abstract Based on the development trend of incorporating fuel holes into swirler-vanes and the advantages of wide operating conditions as well as low NOx emissions of LSI, this paper proposes an original lean premixed LSI with a convergent outlet. The influence of key structures on flowfields and fuel/air premixing uniformities of LSI is investigated by the combination of laser diagnostic experiments and numerical simulations. The flowfields of LSI shows that the main recirculation zone is detached from the convergent outlet and its axial dimensions are smaller than that of HSI, which can decrease the residence time of high-temperature gas to reduce NOx emissions. The fuel/air premixing characteristics show that the positions and diameters of fuel holes affect fuel/air premixing by changing the penetration depth of fuel. And when the penetration depth is moderate, it can give full play to the role of swirling air in enhancing premixing of fuel and air. In addition, the increase of the length of the premixing section can improve the uniformity of fuel/ar premixing, but it can also weaken the swirl intensity and increase the residence time of the combustible mixture within the LSI, which can affect flame stability and increase the risk of auto-ignition. Therefore, the design and selection of LSI structural parameters should comprehensively consider the requirements of fuel/air mixing uniformity, flame stability and avoiding the risk of auto-ignition. The results can provide the technical basis for LSI design and application in aero-derivative and land-based gas turbine combustors.


Author(s):  
Yeshayahou Levy ◽  
Vladimir Erenburg ◽  
Valery Sherbaum ◽  
Vitali Ovcharenko ◽  
Leonid Rosentsvit ◽  
...  

Lean premixed combustion is one of the widely used methods for NOx reduction in gas turbines (GT). When this method is used combustion takes place under low Equivalence Ratio (ER) and at relatively low combustion temperature. While reducing temperature decreases NOx formation, lowering temperature reduces the reaction rate of the hydrocarbon–oxygen reactions and deteriorates combustion stability. The objective of the present work was to study the possibility to decrease the lower limit of the stable combustion regime by the injection of free radicals into the combustion zone. A lean premixed gaseous combustor was designed to include a circumferential concentric pilot flame. The pilot combustor operates under rich fuel to air ratio, therefore it generates a significant amount of reactive radicals. The experiments as well as CFD and CHEMKIN simulations showed that despite of the high temperatures obtained in the vicinity of the pilot ring, the radicals’ injection from the pilot combustor has the potential to lower the limit of the global ER (and temperatures) while maintaining stable combustion. Spectrometric measurements along the combustor showed that the fuel-rich pilot flame generates free radicals that augment combustion stability. In order to study the relevant mechanisms responsible for combustion stabilization, CHEMKIN simulations were performed. The developed chemical network model took into account some of the basic parameters of the combustion process: ER, residence time, and the distribution of the reactances along the combustor. The CHEMKIN simulations showed satisfactory agreement with experimental results.


Author(s):  
Felipe Bolaños ◽  
Dieter Winkler ◽  
Felipe Piringer ◽  
Timothy Griffin ◽  
Rolf Bombach ◽  
...  

The combustion of hydrogen-rich fuels (> 80 % vol. H2), relevant for gas turbine cycles with “pre-combustion” carbon capture, creates great challenges in the application of standard lean premix combustion technology. The significant higher flame speed and drastically reduced auto-ignition delay time of hydrogen compared to those of natural gas, which is normally burned in gas turbines, increase the risk of higher NOX emissions and material damage due to flashback. Combustion concepts for gas turbines operating on hydrogen fuel need to be adapted to assure safe and low-emission combustion. A rich/lean (R/L) combustion concept with integrated heat transfer that addresses the challenges of hydrogen combustion has been investigated. A sub-scale, staged burner with full optical access has been designed and tested at gas turbine relevant conditions (flame temperature of 1750 K, preheat temperature of 400 °C and a pressure of 8 bar). Results of the burner tests have confirmed the capability of the rich/lean staged concept to reduce the NOx emissions for undiluted hydrogen fuel. The NOx emissions were reduced from 165 ppm measured without staging (fuel pre-conversion) to 23 ppm for an R/L design having a fuel-rich hydrogen pre-conversion of 50 % at a constant power of 8.7 kW. In the realized R/L concept the products of the first rich stage, which is ignited by a Pt/Pd catalyst (under a laminar flow, Re ≈ 1900) are combusted in a diffusion-flame-like lean stage (turbulent flow Re ≈ 18500) without any flashback risk. The optical accessibility of the reactor has allowed insight into the combustion processes of both stages. Applying OH-LIF and OH*-chemiluminescence optical techniques, it was shown that mainly homogeneous reactions at rich conditions take place in the first stage, questioning the importance of a catalyst in the system, and opening a wide range of optimization possibilities. The promising results obtained in this study suggest that such a rich/lean staged burner with integrated heat transfer could help to develop a new generation of gas turbine burners for safe and clean combustion of H2-rich fuels.


Author(s):  
S. K. Alavandi ◽  
A. K. Agrawal

Lean premixed combustion of carbon monoxide (CO), hydrogen (H2), and methane (CH4) fuel mixtures with air was investigated experimentally. Combustion at atmospheric pressure was stabilized within porous inert medium made of silicon-carbide coated carbon foam with 4 pores per centimeter. CH4 in the fuel was varied from 100% to 0% (by volume), with the remaining fuel containing equal amounts of CO and H2. Experiments at a fixed air flow rate were conducted by varying the adiabatic flame temperature and fuel composition. Profile of CO and NOx emissions in the axial and transverse directions were taken to identify the post-combustion zone and uniformity of combustion. At a given flame temperature, fuels with CO/H2 produced lower CO and NOx emissions compared to those for CH4. The temperature at the lean blow off limit was significantly lower (compared to CH4) if the fuel contained CO and H2, each greater than 35% by volume.


Author(s):  
Thoralf G. Reichel ◽  
Katharina Goeckeler ◽  
Oliver Paschereit

In the context of lean premixed combustion, the prevention of upstream flame propagation in the premixing zone, referred to as flashback, is a crucial challenge related to the application of hydrogen as a fuel for gas turbines. The location of flame anchoring and its impact on flashback tendencies in a technically premixed, swirl-stabilized hydrogen burner are investigated experimentally at atmospheric pressure conditions using planar laser-induced fluorescence of hydroxyl radicals (OH-PLIF). The inlet conditions are systematically varied with respect to equivalence ratio (ϕ = 0.2–1.0), bulk air velocity u0 = 30–90m/s and burner preheat temperature ranging from 300K to 700K. The burner is mounted in the atmospheric combustion test rig at the HFI, firing at a power of up to 220 kW into a 105 mm diameter quartz cylinder, which provides optical access to the flame region. The experiments were performed using an in-house burner design that previously proved to be highly resistant against flashback occurrence by applying the axial air injection strategy. Axial air injection constitutes a non-swirling air jet on the central axis of the radial swirl generator, thus, influencing the vortex breakdown position. High axial air injection yields excellent flashback resistance and is used to investigate the whole inlet parameter space. In order to trigger flashback, the amount of axially injected air is reduced, which allowed to investigate the near flashback flame behavior. Results show that both, fuel momentum of hydrogen and axial air injection alter the isothermal flow field and cause a downstream shift of the axial flame front location. Such a shift is proven beneficial for flashback resistance. This effect was quantified by applying an edge detection algorithm to the OH-PLIF images, in order to extract the location of maximum flame front likelihood xF. The temperature and equivalence ratio dependence of the parameters xF is identified to be governed by the momentum ratio between fuel and air flow J. These results contribute to the understanding of the superior flashback limits of configurations applying high amounts of axial air injection over medium or none air injection.


Author(s):  
Donald M. Newburry ◽  
Arthur M. Mellor

The semi–empirical characteristic time model (CTM) has been used previously to correlate and predict emissions data from conventional diffusion flame, gas turbine combustors. The form of the model equation was derived for NOx emissions from laboratory flameholders and then extended to conventional gas turbine combustors. The model relates emissions to the characteristic times of distinct combustion subprocesses, with empirically determined model constants. In this paper, a new model is developed for lean premixed (LP) NOx emissions from a perforated plate flameholder combustor burning propane fuel. Several modifications to the diffusion flame CTM were required, including a new activation energy and a more complicated dependence on combustor pressure. Appropriate model constants were determined from the data, and the correlation results are reasonable. An attempt was made to validate the new model with LP NOx data for a different but geometrically similar flameholder operating at lower pressures. The predictions are good for the low equivalence ratio data. However, a systematic error in the reported equivalence ratios may be adversely affecting the predictions of the higher equivalence ratio data through the calculated adiabatic flame temperature.


Author(s):  
Luke H. Cowell ◽  
Matthew P. Larkin

A catalytic combustion system for advanced industrial gas turbines is under long tern development employing recent advances in catalyst and materials technologies. Catalytic combustion is a proven means of burning fuel with single digit NOx emissions levels. However, this technology has yet to be considered for production in an industrial gas turbine for a number of reasons including: limited catalyst durability, demonstration of a system that can operate over all loads and ambient conditions, and market and cost factors. The catalytic combustion system will require extensive modifications to production gas turbines including fuel staging and variable geometry. The combustion system is composed of five elements: a preheat combustor, premixer, catalyst bed, part load injector and post-catalyst combustor. The preheat combustor operates in a lean premixed mode and is used to elevate catalyst inlet air and fuel to operating temperature. The premixer combines fuel and air into a uniform mixture before entering the catalyst. The catalyst bed initiates the fuel-air reactions, elevating the mixture temperature and partially oxidizing the fuel. The part load injector is a lean premixed combustor system that provides fuel and air to the post-catalyst combustor. The post-catalyst combustor is the volume downstream of the catalyst bed where the combustion reactions are completed. At part load conditions a conventional flame bums in this zone. Combustion testing is on-going in a subscale rig to optimize the system and define operating limits. Short duration rig testing has been completed to 9 atmospheres pressure with stable catalytic combustion and NOx emissions down to the 5 ppmv level. Testing was intended to prove-out design elements at representative full load engine conditions. Subscale combustion testing is planned to document performance at part-load conditions. Preliminary full-scale engine design studies are underway.


Sign in / Sign up

Export Citation Format

Share Document