Numerical Investigation on the Flow Characteristics of a Supercritical CO2 Centrifugal Compressor

Author(s):  
Hang Zhao ◽  
Qinghua Deng ◽  
Kuankuan Zheng ◽  
Hanzhen Zhang ◽  
Zhenping Feng

Supercritical CO2 closed-loop Brayton cycles offer the potential of better economical and practical efficiency due to its compact size and smaller compression work as compared with some traditional working fluids cycles, in which compressor is the key component. In this paper, the aerodynamic design and impeller aerodynamic optimization were conducted for a single stage centrifugal compressor with a combined vaneless and vaned diffuser, operating with CO2 slightly above the vapor-liquid critical point. The NIST REFPROP database was used for the computation of supercritical CO2 properties in design analysis and numerical investigation. The flow characteristics of the supercritical CO2 compressor were investigated by NUMECA FINE/Turbo. In order to weaken the low pressure regions, a vaneless diffuser was applied in this design, which would control and reduce the distribution differences of fluid thermodynamic states and increase fluid static pressure. The results indicate that there are no obvious low pressure regions occurring close to the leading edge of vaned diffuser. So it is observed in the design process that the vaneless diffuser could improve the aerodynamic performance of supercritical CO2 compressor. Compared with the operating conditions of the compressor only under centrifugal force, the pressure load from the aerodynamic analysis and the centrifugal load due to high speed of rotation were considered in the study of the stress and deformation of the structure of impeller by ANSYS/Mechanical. It can be concluded that supercritical CO2 provides unique properties for the compressor working process, which have a significant influence on finite element modeling in structural analysis. For the present design the maximum von Mises stress and total deformation are shown much smaller than the maximum allowable values, and thus the compressor could work in a wide range of operating conditions.

1987 ◽  
Author(s):  
A. N. Abdel-Hamid ◽  
U. Haupt ◽  
M. Rautenberg

Self-excited flow oscillations in a high performance centrifugal compressor with vaned diffuser have been experimentally investigated over a wide range of operating conditions. The space and time characteristics of the flow oscillations in the compressor from inlet to outlet were measured using fast response dynamic pressure transducers on the shroud wall and blade mounted straingages. Multi-channel signal analysis techniques in the frequency domain clearly identified the onset of the oscillations and its type. Rotating stall was found to exist in certain regimes of the compressor map but did not necessarily preceed the occurrence of the surge phenomena. At compressor speeds below 13600 rpm the rotating non-uniform flow when it occurred was composed of three lobes and rotated at approximately 5–6 % of the impeller speed. Above 13600 rpm the rotating pattern changed to two lobes and rotated at approximately 16–20 % of the impeller speed. The direction of rotation of both patterns was opposite to that of the impeller. Analysis of the performance characteristics of the compressor components prior to and during flow oscillations indicates that the relative magnitude of the flow fluctuations in the semi-vaneless space downstream of the impeller are the largest which points towards the close relationship between the conditions leading to the onset of the oscillations and the flow details in this region of the compressor. Additional confirmation of this relationship is obtained from comparison between the results obtained in this study and those obtained when the same compressor was operated with a vaneless diffuser.


1988 ◽  
Vol 110 (3) ◽  
pp. 293-302 ◽  
Author(s):  
U. Haupt ◽  
U. Seidel ◽  
A. N. Abdel-Hamid ◽  
M. Rautenberg

Experiments were conducted to investigate the characteristics of self-excited flow oscillations in a high-performance centrifugal compressor system with a straight channel radial vaned diffuser. Fast response dynamic pressure transducers on the shroud wall and blade-mounted strain gages were used to identify the onset of the oscillations and their characteristics in space and time. In addition, flow characteristics near the shroud wall were visualized by an oil injection method, showing the extent of upstream directed reverse flow in the impeller range during significant unsteady flow compressor operation. Rotating nonuniform flow patterns were found in a wide range of operating speeds before the occurrence of surge. The number of lobes in the nonuniform flow patterns was dependent on the operating conditions and varied from two to four. Results of this experimental investigation were compared with those obtained from a previous investigation of the same compressor but with a cambered vane diffuser. Considerable similarity between the two configurations was found in the spatial distribution of the unsteady pressure field and in the frequencies of the fluctuations. The stability margin before the occurrence of surge and the operating regimes in which very intense pressure fluctuations were found were however different. In both cases, flow visualization techniques revealed the occurrence of reversed flow near the shroud wall of the impeller. Reverse flow extent up to the leading edge of the splitter blades systematically correlated with the occurrence of a nonuniform pressure pattern rotating with relatively high speed. Low rotational speed pressure patterns were observed when the extent of the reverse flow was up to the leading edge of the long blade. These different flow characteristics can be related to the occurrence of distinct rotating stall cell numbers. This result could be confirmed by unsteady pressure and blade vibration measurements.


2015 ◽  
Vol 137 (7) ◽  
Author(s):  
Klemens Vogel ◽  
Reza S. Abhari ◽  
Armin Zemp

Vaned diffusers in centrifugal compressor stages are used to achieve higher stage pressure ratios, higher stage efficiencies, and more compact designs. The interaction of the stationary diffuser with the impeller can lead to resonant vibration with potentially devastating effects. This paper presents unsteady diffuser vane surface pressure measurements using in-house developed, flush mounted, fast response piezoresistive pressure transducers. The unsteady pressures were recorded for nine operating conditions, covering a wide range of the compressor map. Experimental work was complemented by 3D unsteady computational fluid dynamics (CFD) simulations using ansys cfx V12.1 to detail the unsteady diffuser aerodynamics. Pressure fluctuations of up to 34.4% of the inlet pressure were found. High pressure variations are present all along the vane and are not restricted to the leading edge region. Frequency analysis of the measured vane surface pressures show that reduced impeller loading, and the corresponding reduction of tip leakage fluid changes the characteristics of the fluctuations from a main blade count to a total blade count. The unsteady pressure fluctuations in the diffuser originate from three distinct locations. The impact of the jet-wake flow leaving the impeller results in high variation close to the leading edge. It was observed that CFD results overpredicted the amplitude of the pressure fluctuation on average by 62%.


Author(s):  
Klemens Vogel ◽  
Reza S. Abhari ◽  
Armin Zemp

Vaned diffusers in centrifugal compressor stages are used to achieve higher stage pressure ratios, higher stage efficiencies and more compact designs. The interaction of the stationary diffuser with the impeller can lead to resonant vibration with potentially devastating effects. This paper presents unsteady diffuser vane surface pressure measurements using in-house developed, flush mounted, fast response piezo-resistive pressure transducers. The unsteady pressures were recorded for 9 operating conditions, covering a wide range of the compressor map. Experimental work was complemented by 3D unsteady CFD simulations using ANSYS CFX V12.1 to detail the unsteady diffuser aerodynamics. Pressure fluctuations of up to 34.4% of the inlet pressure were found. High pressure variations are present all along the vane and are not restricted to the leading edge region. Frequency analysis of the measured vane surface pressures show that reduced impeller loading and the corresponding reduction of tip leakage fluid changes the characteristics of the fluctuations from a main blade count to a total blade count. The unsteady pressure fluctuations in the diffuser originate from three distinct locations. The impact of the jet wake flow leaving the impeller results in high variation close to the leading edge. It was observed that CFD results overpredicted the amplitude of the pressure fluctuation on average by 62%.


Author(s):  
Swati Saxena ◽  
Ramakrishna Mallina ◽  
Francisco Moraga ◽  
Douglas Hofer

This paper is presented in two parts. Part I (Tabular fluid properties for real gas analysis) describes an approach to creating a tabular representation of the equation of state that is applicable to any fluid. This approach is applied to generating an accurate and robust tabular representation of the RefProp CO2 properties. Part II (this paper) presents numerical simulations of a low flow coefficient supercritical CO2 centrifugal compressor developed for a closed loop power cycle. The real gas tables presented in part I are used in these simulations. Three operating conditions are simulated near the CO2 critical point: normal day (85 bar, 35C), hot day (105 bar, 50 C) and cold day (70 bar, 20C) conditions. The compressor is a single stage overhung design with shrouded impeller, 155 mm impeller tip diameter and a vaneless diffuser. An axial variable inlet guide vane (IGV) is used to control the incoming swirl into the impeller. An in-house three-dimensional computational fluid dynamics (CFD) solver named TACOMA is used with real gas tables for the steady flow simulations. The equilibrium thermodynamic modeling is used in this study. The real gas effects are important in the desired impeller operating range. It is observed that both the operating range (minimum and maximum volumetric flow rate) and the pressure ratio across the impeller are dependent on the inlet conditions. The compressor has nearly 25% higher operating range on a hot day as compared to the normal day conditions. A condensation region is observed near the impeller leading edge which grows as the compressor operating point moves towards choke. The impeller chokes near the mid-chord due to lower speed of sound in the liquid-vapor region resulting in a sharp drop near the choke side of the speedline. This behavior is explained by analyzing the 3D flow field within the impeller and thermodynamic quantities along the streamline. The 3D flow analysis for the flow near the critical point provides useful insight for the designers to modify the current compressor design for higher efficiency.


Computation ◽  
2018 ◽  
Vol 6 (4) ◽  
pp. 54 ◽  
Author(s):  
Senthil Raman ◽  
Heuy Kim

A centrifugal compressor working with supercritical CO 2 (S-CO 2 ) has several advantages over other supercritical and conventional compressors. S-CO 2 is as dense as the liquid CO 2 and becomes difficult to compress. Thus, during the operation, the S-CO 2 centrifugal compressor requires lesser compression work than the gaseous CO 2 . The performance of S-CO 2 compressors is highly varying with tip clearance and vanes in the diffuser. To improve the performance of the S-CO 2 centrifugal compressor, knowledge about the influence of individual components on the performance characteristics is necessary. This present study considers an S-CO 2 compressor designed with traditional engineering design tools based on ideal gas behaviour and tested by SANDIA national laboratory. Three-dimensional, steady, viscous flow through the S-CO 2 compressor was analysed with computational fluid dynamics solver based on the finite volume method. Navier-Stokes equations are solved with K- ω (SST) turbulence model at operating conditions in the supercritical regime. Performance of the impeller, the main component of the centrifugal compressor is compared with the impeller with vaneless diffuser and vaned diffuser configurations. The flow characteristics of the shrouded impeller are also studied to analyse the tip-leakage effect.


Author(s):  
Timothy C. Allison ◽  
Natalie R. Smith ◽  
Robert Pelton ◽  
Jason C. Wilkes ◽  
Sewoong Jung

Successful implementation of sCO2 power cycles requires high compressor efficiency at both the design-point and over a wide operating range in order to maximize cycle power output and maintain stable operation over a wide range of transient and part-load operating conditions. This requirement is particularly true for air-cooled cycles where compressor inlet density is a strong function of inlet temperature that is subject to daily and seasonal variations as well as transient events. In order to meet these requirements, a novel centrifugal compressor stage design was developed that incorporates multiple novel range extension features, including a passive recirculating casing treatment and semi-open impeller design. This design, presented and analyzed for CO2 operation in a previous paper, was fabricated via direct metal laser sintering and tested in an open-loop test rig in order to validate simulation results and the effectiveness of the casing treatment configuration. Predicted performance curves in air and CO2 conditions are compared, resulting in a reduced diffuser width requirement for the air test in order to match design velocities and demonstrate the casing treatment. Test results show that the casing treatment performance generally matched computational fluid dynamics (CFD) predictions, demonstrating an operating range of 69% and efficiency above air predictions across the entire map. The casing treatment configuration demonstrated improvements over the solid wall configuration in stage performance and flow characteristics at low flows, resulting in an effective 14% increase in operating range with a 0.5-point efficiency penalty. The test results are also compared to a traditional fully shrouded impeller with the same flow coefficient and similar head coefficient, showing a 42% range improvement over traditional designs.


Author(s):  
Shashank Mishra ◽  
Shaaban Abdallah ◽  
Mark Turner

Multistage axial compressor has an advantage of lower stage loading as compared to a single stage. Several stages with low pressure ratio are linked together which allows for multiplication of pressure to generate high pressure ratio in an axial compressor. Since each stage has low pressure ratio they operate at a higher efficiency and the efficiency of multi-stage axial compressor as a whole is very high. Although, single stage centrifugal compressor has higher pressure ratio compared with an axial compressor but multistage centrifugal compressors are not as efficient because the flow has to be turned from radial at outlet to axial at inlet for each stage. The present study explores the advantages of extending the axial compressor efficient flow path that consist of rotor stator stages to the centrifugal compressor stage. In this invention, two rotating rows of blades are mounted on the same impeller disk, separated by a stator blade row attached to the casing. A certain amount of turning can be achieved through a single stage centrifugal compressor before flow starts separating, thus dividing it into multiple stages would be advantageous as it would allow for more flow turning. Also the individual stage now operate with low pressure ratio and high efficiency resulting into an overall increase in pressure ratio and efficiency. The baseline is derived from the NASA low speed centrifugal compressor design which is a 55 degree backward swept impeller. Flow characteristics of the novel multistage design are compared with a single stage centrifugal compressor. The flow path of the baseline and multi-stage compressor are created using 3DBGB tool and DAKOTA is used to optimize the performance of baseline as well novel design. The optimization techniques used are Genetic algorithm followed by Numerical Gradient method. The optimization resulted into improvements in incidence and geometry which significantly improved the performance over baseline compressor design. The multistage compressor is more efficient with a higher pressure ratio compared with the base line design for the same work input and initial conditions.


Author(s):  
Ziliang Li ◽  
Xingen Lu ◽  
Ge Han ◽  
Yanfeng Zhang ◽  
Shengfeng Zhao ◽  
...  

Centrifugal compressors often suffer relatively low efficiency and a terrible operating range particularly due to the complex flow structure and intense impeller/diffuser interaction. Numerous studies have focused on improving the centrifugal compressor performance using many innovative ideas, such as the tandem impeller, which has become increasingly attractive due to its ability to achieve the flow control with no additional air supply configurations and control costs in compressor. However, few studies that attempted to the investigation of tandem impeller have been published until now and the results are always contradictory. To explore the potential of the tandem impeller to enhance the compressor performance and the underlying mechanism of the flow phenomena in the tandem impellers, this paper numerically investigated a high-pressure-ratio centrifugal compressor with several tandem impellers at off-design operating speeds. The results encouragingly demonstrate that the tandem impeller can achieve a performance enhancement over a wide range of operating conditions. Approximately 1.8% maximum enhancement in isentropic efficiency and 5.0% maximum enhancement in operating range are achieved with the inducer/exducer circumferential displacement of [Formula: see text] = 25% and 50%, respectively. The observed stage performance gain of the tandem impellers decreases when the operating speed increases due to the increased inducer shock, increased wake losses, and deteriorated tandem impeller discharge flow uniformity. In addition, the tandem impeller can extend the impeller operating range particularly at low rotation speeds, which is found to be a result from the suppression of the low-momentum fluid radial movement. The results also indicate that the maximum flux capacity of the tandem impeller decreases due to the restriction of the inducer airfoil Kutta–Joukowsky condition.