Developing an Optimum Design of the Double Layer Microchannel Heat Sink for High Speed CPUs

Author(s):  
Ali Radwan ◽  
Essam M. Abo-Zahhad ◽  
O. Abdelrehim ◽  
A. H. El-Shazly ◽  
Shinichi Ookawara ◽  
...  

Abstract High speed CPUs and electronic chips usually dissipate relatively large quantities of energy in the form of heat. The limited available cooling space requires innovative and efficient thermal management techniques. These techniques must accomplish low operation temperatures along with uniform temperature distribution over the chip surface. Recently, several researches focused on developing different microchannel heat sink (MCHS) designs for this purpose. Among these designs is the double layer microchannel heat sink (DL-MCHS), which can be operated in either parallel flow (PF) or counter flow (CF) operation modes. The thermo-hydraulic characteristics of this heat sink was comprehensively investigated in the literature using numerical methods. However, based on the authors literature survey, all the previous numerical investigations considered the computational domain as a straight section with multi-channels in each layer. This approach assumes a uniform velocity for all the flow channels in each layer and neglect the effect of the inlet and outlet headers. In addition, the heat interaction between the coolant in both layers through the header section was not considered. These assumptions cause a considerable discrepancy between the numerical results in the literature and the realistic conditions. Therefore, in this work, a detailed 3D conjugate heat transfer model is developed. In this 3D model, DL-MCHS is designed with and without headers. The designed heat sinks are operated under PF and CF conditions. For a specific electronic chip with dimensions of 13 mm × 40 mm at a heat flux of 5 kW/m2. The model is validated with the experimental results in the literature. It is found that, including the header design in the simulation of the DL-MCHS must be considered in the simulation to predict the accurate thermo-hydraulic performance of the DL-MCHS specially in the CF. Further, using the DL-MCHS in PF operation accomplished a lower average chip temperature compared with the CF. Furthermore, at high coolant flowrate, neglecting the effect of the header in the CFD calculations can be approximated to predict the chip surface temperature. And finally, neglecting the header in the CFD calculations significantly affect the calculated pumping power for both PF and CF operated DL-MCHS.

2013 ◽  
Vol 479-480 ◽  
pp. 411-415 ◽  
Author(s):  
Wong Kok Cheong ◽  
Fashli Nazhirin bin Ahmad Muezzin

A numerical study is conducted to predict the effects of physical parameters of a double layer microchannel heat sink on heat transfer. The physical parameters investigated are the channel height and channel width for different flow orientation at the upper and lower channels. For the range of Reynolds number investigated, results show that parallel flow configuration leads to better heat transfer performance than counter flow. Lower thermal resistance can be achieved in a double-layered microchannel heat sink with higher channel height and lower channel width.


2001 ◽  
Author(s):  
G. Hetsroni ◽  
A. Mosyak ◽  
Z. Segal

Abstract Experimental investigation of a heat sink for electronics cooling is performed. The objective is to keep the operating temperature at a relatively low level of about 323–333K, while reducing the undesired temperature variation in both the streamwise and transverse directions. The experimental study is based on systematic temperature, flow and pressure measurements, infrared radiometry and high-speed digital video imaging. The heat sink has parallel triangular microchannels with a base of 250μm. According to the objectives of the present study, Vertrel XF is chosen as the working fluid. Experiments on flow boiling of Vertrel XF in the microchannel heat sink are performed to study the effect of mass velocity and vapor quality on the heat transfer, as well as to compare the two-phase results to a single-phase water flow.


2021 ◽  
Vol 1163 ◽  
pp. 73-88
Author(s):  
Md Tanbir Sarowar

Microchannel heat sink plays a vital role in removing a considerable amount of heat flux from a small surface area from different electronic devices. In recent times, the rapid development of electronic devices requires the improvement of these heat sinks to a greater extent. In this aspect, the selection of appropriate substrate materials of the heat sinks is of vital importance. In this paper, three boron-based ultra-high temperature ceramic materials (ZrB2, TiB2, and HfB2) are compared as a substrate material for the microchannel heat sink using a numerical approach. The fluid flow and heat transfer are analyzed using the finite volume method. The results showed that the maximum temperature of the heat source didn’t exceed 355K at 3.6MWm-2 for any material. The results also indicated HfB2 and TiB2 to be more useful as a substrate material than ZrB2. By applying 3.6 MWm-2 heat flux at the source, the maximum obtained surface heat transfer coefficient was 175.2 KWm-2K-1 in a heat sink having substrate material HfB2.


Author(s):  
S. Manna ◽  
S. K. Ghosh ◽  
S. C. Haldar

Free convection from an upward facing radial heat sink with fins at an equal angular gap attached to an isothermal base has been investigated numerically. The governing equations in primitive variables were changed to vorticity-vector potential formulation, and an in-house code was developed using finite difference technique. To close the computational domain, two pseudo boundaries were considered. Length, height, and number of fins strongly influence the rate of heat transfer while the fin thickness has a marginal role. As the fin length increases, the rate of heat transfer first increases and then remains almost unaffected. However, the active length of the fins depends on the strength of buoyancy. Heat transfer continuously increases with fin height but with diminishing effect. Adding more number of fins has two opposing effects. It provides more surface area for convection, but at the same time, the induced air is unable to reach the interior of the heat sink making the inner portion of the fins inoperative. As a result of these two opposing influences, heat transfer increases in the beginning and then decreases as more fins are added. This article suggests various fin parameters to achieve maximum cooling. In addition, one can estimate the rate of cooling to be achieved by any radial heat sink.


Fluids ◽  
2020 ◽  
Vol 5 (3) ◽  
pp. 143
Author(s):  
Carlo Nonino ◽  
Stefano Savino

An in-house finite element method (FEM) procedure is used to carry out a numerical study on the thermal behavior of cross-flow double-layered microchannel heat sinks with an unequal number of microchannels in the two layers. The thermal performance is compared with those yielded by other more conventional flow configurations. It is shown that if properly designed, i.e., with several microchannels in the top layer smaller than that in the bottom layer, cross-flow double-layered microchannel heat sinks can provide an acceptable thermal resistance and a reasonably good temperature uniformity of the heated base with a header design that is much simpler than that required by the counter-flow arrangement.


Author(s):  
Suchismita Sarangi ◽  
Karthik K. Bodla ◽  
Suresh V. Garimella ◽  
Jayathi Y. Murthy

Conventional microchannel heat sinks provide good heat dissipation capability but are associated with high pressure drop and corresponding pumping power. The use of a manifold system that distributes the flow into the microchannels through multiple, alternating inlet and outlet pairs is investigated here. This manifold arrangement greatly reduces the pressure drop incurred due to the smaller flow paths, while simultaneously increasing the heat transfer coefficient by tripping the thermal boundary layers. A three-dimensional numerical model is developed and validated, to study the effect of various geometric parameters on the performance of the manifold microchannel heat sink. Apart from a deterministic analysis, a probabilistic optimization study is also performed. In the presence of uncertainties in the geometric and operating parameters of the system, this probabilistic optimization approach yields an optimal design that is also robust and reliable. Uncertainty-based optimization also yields auxiliary information regarding local and global sensitivities and helps identify the input parameters to which outputs are most sensitive. This information can be used to design improved experiments targeted at the most sensitive inputs. Optimization under uncertainty also provides a quantitative estimate of the allowable uncertainty in input parameters for an acceptable uncertainty in the relevant output parameters. The optimal geometric design parameters with uncertainties that maximize heat transfer coefficient while minimizing pressure drop for fixed input conditions are identified for a manifold microchannel heat sink. A comparison between the deterministic and probabilistic optimization results is also presented.


Author(s):  
Ling Ling ◽  
Yanfeng Fan ◽  
Ibrahim Hassan

Higher heat flux is produced by Micro-Electro-Mechanical Systems (MEMS) because of their reduced size and increased clock speed. At the mean time, studies of non-uniform heating conditions which are more practical than uniform heating conditions are inadequate and needed urgently. Four nonuniform heating conditions are simulated in the paper. Three heat sinks with different widths of cross-linked channels locating above the center of hotspots are studied and compared to conventional straight microchannel heat sink. Half of the module geometry is chosen to be the computational domain. Two hotspots are placed at the bottom surface. The coolant is water, whose properties are dependent on temperature. Two inlet velocities, 0.5 m/s and 1 m/s, are tested for each heat sink. Temperature profile at the hotspots, pressure drop and total thermal resistance are selected as criteria of evaluating heat sink performance. All heat sinks have better performance when there is an upstream hotspot or the upstream hotspot is subjected to a higher heat flux. Cross-linked channel width of 0.5 mm has the best benefit to obtain better temperature uniformity without increasing the maximum temperature on the bottom surface.


Author(s):  
Ali Radwan ◽  
Mohamed M. Awad ◽  
Shinichi Ookawara ◽  
Mahmoud Ahmed

Abstract In this study, a new design of double layer microchannel heat sink (DL-MCHS) has been monolithically fabricated using 3D metal printer and experimentally examined as a heat sink for concentrator photovoltaic (CPV) systems. Single phase liquid cooling using ethanol and flow boiling cooling using NOVEC-7000 coolant in the designed DL-MCHS are experimentally compared. The results proved that using the flow boiling cooling technique for the CPV systems attained a lower solar cell temperature with high temperature uniformity. In more details, flow boiling in counterflow (CF) operated DL-MCHS, attained a very low solar cell temperature close to the NOVEC-7000 boiling point with temperature uniformity of 0.2 °C over a wide range of coolant flow rate from 25–250 ml/hr.