Heat Transfer to a Ducted, Semiconfined Impinging Synthetic Air Jet

Author(s):  
Daniel Rylatt ◽  
Tadhg S. O’Donovan

Heat transfer to confined impinging synthetic air jets is investigated experimentally. The influence of ducting on the cooling performance of synthetic air jets is of particular interest. Heat transfer to the jets is reported for a wide range of experimental parameters including nozzle to impingement surface spacings (0.5 to 5 jet diameters), Reynolds numbers (2000, 3000 and 4000) and non-dimensional Stroke lengths, L0/D (10 15 and 20 respectively). A range of ducting outlet sizes were also investigated (1, 1.2, 1.4 jet diameters). It has been found that ducting can have the effect of reducing the turbulent mixing of the flow but overall enhances the rate of heat transfer to the jet at low H/D < 2. The largest ducting outlet of 1.4 jet diameters has also been shown to outperform the others across the whole range of variables tested.

Author(s):  
Tadhg S. O’Donovan ◽  
Darina B. Murray

Impinging air jets are known as a method of achieving particularly high heat transfer coefficients and are employed in many applications including the cooling of electronics, manufacturing processes such as grinding, etc. The current investigation is concerned with acoustically exciting an impinging air jet to enhance its overall cooling capacity. Distributions of the heat transfer to an axially impinging air jet for a range of Reynolds numbers (Re) from 10000 to 30000, non-dimensional nozzle to impingement surface heights (H/D) from 0.5 to 2 and excitation frequencies (f) that range from 0.5 to 1 times the natural frequency of the jet are presented. For this low range of nozzle to impingement surface spacings it has been shown that the heat transfer distribution exhibits a peak at the stagnation point and secondary peaks at a radial location that is both excitation frequency and Reynolds number dependent. Distributions of the fluctuating component of the heat transfer coefficient are also presented for the range of parameters tested. These have been used, along with spectral analysis of the heat flux signal, to discern whether local variations in heat transfer are due to changes in the local vortex flow or to changes in the mean flow structure of the impinging jet.


2000 ◽  
Vol 123 (3) ◽  
pp. 165-172 ◽  
Author(s):  
Suresh V. Garimella ◽  
Vincent P. Schroeder

Heat transfer from a discrete heat source to multiple, normally impinging, confined air jets was experimentally investigated. The jets issued from short, square-edged orifices with still-developing velocity profiles on to a foil heat source which produced a constant heat flux. The orifice plate and the surface containing the heat source were mounted opposite each other in a parallel-plates arrangement to effect radial outflow of the spent fluid. The local surface temperature was measured in fine increments over the entire heat source. Experiments were conducted for different jet Reynolds numbers (5000<Re<20,000), orifice-to-target spacing 0.5<H/d<4, and multiple-orifice arrangements. The results are compared to those previously obtained for single air jets. A reduction in orifice-to-target spacing was found to increase the heat transfer coefficient in multiple jets, with this effect being stronger at the higher Reynolds numbers. With a nine-jet arrangement, the heat transfer to the central jet was higher than for a corresponding single jet. For a four-jet arrangement, however, each jet was found to have stagnation-region heat transfer coefficients that were comparable to the single-jet values. The effectiveness of single and multiple jets in removing heat from a given heat source is compared at a fixed total flow rate. Predictive correlations are proposed for single and multiple jet impingement heat transfer.


Author(s):  
Flavia Barbosa ◽  
Carlos Costa ◽  
Senhorinha Teixeira ◽  
Jose Carlos Teixeira

Abstract The study of the flow interaction and the heat transfer between air jets and a surface is of paramount importance in industrial processes that apply air jet impingement. To ensure a good performance of the process, high heat transfer rates and uniformization of the flow over the target plate are required. To perform this analysis, a PIV technique was implemented for the measurement of the flow velocity fields. However, as any real experiment, the values recorded by the PIV method are subjected to several errors that compromise the reliability and accuracy of the measurements. These errors can have different sources, from the installation and alignment to the particles seeding and calibration procedure. To maximize the accuracy of the experimental results, this paper focus on the identification of measurement errors and uncertainty quantification of an experimental set up specially built for the analysis of the interaction between air jets and a target surface. This work presents an analysis of the system, and the source of errors are identified, quantified and, when possible, corrected. The particle seeding is characterized and its efficiency for the flow tracking is analyzed. The setup was tested to fully characterize the flow field in terms of mean velocity profile and turbulence intensity over a wide range of Reynolds numbers and temperature. Several velocity fields are then measured until convergence of the flow quantities is reached. The combination of these measurements with high spatial resolution and low measurement errors allow to obtain accurate and precise measurements.


Author(s):  
Tadhg S. O’Donovan ◽  
Darina B. Murray ◽  
Andrew A. Torrance

Convective heat transfer to an impinging air jet is known to yield high local and area averaged heat transfer coefficients. Such jets are of interest in the cooling of electronic components and of turbine blades and in manufacturing processes such as grinding. The current research is concerned with the measurement of heat transfer to an impinging air jet over a wide range of test parameters. These include Reynolds numbers, Re, from 10000 to 30000 and nozzle to impingement surface distance, H/D, from 0.5 to 8. The current research reports both mean and fluctuating heat transfer distributions up to 6 diameters from the geometric centre of the jet. The heat transfer results are compared to local velocity data. At low nozzle to impingement surface spacings the heat transfer distributions exhibit peaks at a radial location that varies with both Re and H/D. These peaks are shown to be due to an abrupt increase in turbulence in the wall jet boundary layer. At certain test configurations vortices that initiate in the shear layer impinge on the surface and move along the wall jet before being broken down into smaller scale turbulence. The effects of the vortical flow on the heat transfer mechanisms in an impinging jet flow are discussed.


2014 ◽  
Vol 663 ◽  
pp. 322-328 ◽  
Author(s):  
Ali Ahmed Gitan ◽  
Rozli Zulkifli ◽  
Kamaruzaman Sopian ◽  
Shahrir Abdullah

The problem of environmental pollution and depletion of fossil fuel can be reduced in automotives by using an alternative bio-fuel and improve the ignition process in engine. Both solutions need to use the fuel preheating technique. This work presents the idea of fuel preheating by using exhaust impingement on the fuel tank. Heat transfer between twin pulsating hot air jets and flat copper target was investigated as an application for preheating of automotive fuel to improve ignition process in the engine. The nozzle of 20 mm was used to produce air jet of Reynolds number, Re ≃ 5500 and a temperature of 54°C. The impinged target was imposed to still air surrounding at temperature of 24°C. Pulsating frequencies of 10-50 Hz were applied on air jets by using twin pulsating jet mechanism. The effect of pulsation frequency on heat transfer was measured using IR camera and heat flux-temperature micro foil sensor. The results obtained by both of these methods showed well agreement. Also, the results revealed significant influence of flow rate difference between steady and pulsating jet cases. In addition, the highest Nusselt number, Nu ≃ 7.2, was obtained at pulsation frequency of 20 Hz.


Author(s):  
Anil K. Tolpadi ◽  
Michael E. Crawford

The heat transfer and aerodynamic performance of turbine airfoils are greatly influenced by the gas side surface finish. In order to operate at higher efficiencies and to have reduced cooling requirements, airfoil designs require better surface finishing processes to create smoother surfaces. In this paper, three different cast airfoils were analyzed: the first airfoil was grit blasted and codep coated, the second airfoil was tumbled and aluminide coated, and the third airfoil was polished further. Each of these airfoils had different levels of roughness. The TEXSTAN boundary layer code was used to make predictions of the heat transfer along both the pressure and suction sides of all three airfoils. These predictions have been compared to corresponding heat transfer data reported earlier by Abuaf et al. (1997). The data were obtained over a wide range of Reynolds numbers simulating typical aircraft engine conditions. A three-parameter full-cone based roughness model was implemented in TEXSTAN and used for the predictions. The three parameters were the centerline average roughness, the cone height and the cone-to-cone pitch. The heat transfer coefficient predictions indicated good agreement with the data over most Reynolds numbers and for all airfoils-both pressure and suction sides. The transition location on the pressure side was well predicted for all airfoils; on the suction side, transition was well predicted at the higher Reynolds numbers but was computed to be somewhat early at the lower Reynolds numbers. Also, at lower Reynolds numbers, the heat transfer coefficients were not in very good agreement with the data on the suction side.


Author(s):  
Shang-Feng Yang ◽  
Je-Chin Han ◽  
Salam Azad ◽  
Ching-Pang Lee

This paper experimentally investigates the effect of rotation on heat transfer in typical turbine blade serpentine coolant passage with ribbed walls at low Mach numbers. To achieve the low Mach number (around 0.01) condition, pressurized Freon R-134a vapor is utilized as the working fluid. The flow in the first passage is radial outward, after the 180 deg tip turn the flow is radial inward to the second passage, and after the 180 deg hub turn the flow is radial outward to the third passage. The effects of rotation on the heat transfer coefficients were investigated at rotation numbers up to 0.6 and Reynolds numbers from 30,000 to 70,000. Heat transfer coefficients were measured using the thermocouples-copper-plate-heater regional average method. Heat transfer results are obtained over a wide range of Reynolds numbers and rotation numbers. An increase in heat transfer rates due to rotation is observed in radially outward passes; a reduction in heat transfer rate is observed in the radially inward pass. Regional heat transfer coefficients are correlated with Reynolds numbers for nonrotation and with rotation numbers for rotating condition, respectively. The results can be useful for understanding real rotor blade coolant passage heat transfer under low Mach number, medium–high Reynolds number, and high rotation number conditions.


Author(s):  
Patricia Streufert ◽  
Terry X. Yan ◽  
Mahdi G. Baygloo

Local turbulent convective heat transfer from a flat plate to a circular impinging air jet is numerically investigated. The jet-to-plate distance (L/D) effect on local heat transfer is the main focus of this study. The eddy viscosity V2F turbulence model is used with a nonuniform structured mesh. Reynolds-Averaged Navier-Stokes equations (RANS) and the energy equation are solved for axisymmetric, three-dimensional flow. The numerical solutions obtained are compared with published experimental data. Four jet-to-plate distances, (L/D = 2, 4, 6 and 10) and seven Reynolds numbers (Re = 7,000, 15,000, 23,000, 50,000, 70,000, 100,000 and 120,000) were parametrically studied. Local and average heat transfer results are analyzed and correlated with Reynolds number and the jet-to-plate distance. Results show that the numerical solutions matched experimental data best at low jet-to-plate distances and lower Reynolds numbers, decreasing in ability to accurately predict the heat transfer as jet-to-plate distance and Reynolds number was increased.


Author(s):  
J. E. Kingery ◽  
F. E. Ames

A database for stagnation region heat transfer has been extended to include heat transfer measurements acquired downstream from a new high intensity turbulence generator. This work was motivated by gas turbine industry heat transfer designers who deal with heat transfer environments with increasing Reynolds numbers and very high turbulence levels. The new mock aero-combustor turbulence generator produces turbulence levels which average 17.4%, which is 37% higher than the older turbulence generator. The increased level of turbulence is caused by the reduced contraction ratio from the liner to the exit. Heat transfer measurements were acquired on two large cylindrical leading edge test surfaces having a four to one range in leading edge diameter (40.64 cm and 10.16 cm). Gandvarapu and Ames [1] previously acquired heat transfer measurements for six turbulence conditions including three grid conditions, two lower turbulence aero-combustor conditions, and a low turbulence condition. The data are documented and tabulated for an eight to one range in Reynolds numbers for each test surface with Reynolds numbers ranging from 62,500 to 500,000 for the large leading edge and 15,625 to 125,000 for the smaller leading edge. The data show augmentation levels of up to 136% in the stagnation region for the large leading edge. This heat transfer rate is an increase over the previous aero-combustor turbulence generator which had augmentation levels up to 110%. Note, the rate of increase in heat transfer augmentation decreases for the large cylindrical leading edge inferring only a limited level of turbulence intensification in the stagnation region. The smaller cylindrical leading edge shows more consistency with earlier stagnation region heat transfer results correlated on the TRL (Turbulence, Reynolds number, Length scale) parameter. The downstream regions of both test surfaces continue to accelerate the flow but at a much lower rate than the leading edge. Bypass transition occurs in these regions providing a useful set of data to ground the prediction of transition onset and length over a wide range of Reynolds numbers and turbulence intensity and scales.


Author(s):  
Chadia Haidar ◽  
Rachid Boutarfa ◽  
Mohamed Sennoune ◽  
Souad Harmand

This work focuses on the numerical and experimental study of convective heat transfer in a rotor of a discoidal the machine with an eccentric impinging jet. Convective heat transfers are determined experimentally in steady state on the surface of a single rotating disk. The experimental technique is based on the use of infrared thermography to access surface temperature measurement, and on the numerical resolution of the energy equation in steady-state, to evaluate local convective coefficients. The results from the numerical simulation are compared with heat transfer experiments for rotational Reynolds numbers between 2.38×105 and 5.44×105 and for the jet's Reynolds numbers ranging from 16.5×103 to 49.6 ×103. A good agreement between the two approaches was obtained in the case of a single rotating disk, which confirms us in the choice of our numerical model. On the other hand, a numerical study of the flow and convective heat transfer in the case of an unconfined rotor-stator system with an eccentric air jet impinging and for a dimensionless spacing G=0.02, was carried out. The results obtained revealed the presence of different heat transfer zones dominated either by rotation only, by the air flow only or by the dynamics of the rotation flow superimposed on that of the air flow. Critical radii on the rotor surface have been identified