Effect of Geometry on the Performance of Miniature Heat Pipe

Author(s):  
Ahmed Imtiaz Uddin ◽  
A. S. M. Atiqul Islam ◽  
Chowdhury Md. Feroz

An experimental study is performed to investigate the effect of geometry on the performance of miniature heat pipe (MHP). The experiment is conducted with circular and square MHPs having the same hydraulic diameter of 5 mm and length of 150 mm with acetone as the working fluid. The major findings in the investigation are as follows. At a constant heat flux, coolant flow rate and inclination angle, wall temperatures of evaporator section of circular MHP are higher than that of the square MHP. With the decrease in both inclination angle and coolant flow rate, the rate of increase in wall temperature of the evaporator section for circular MHP is higher than that of square MHP. Thermal resistance of the circular MHP is almost independent of coolant flow rate but for square MHP, thermal resistance decreases with the increase in coolant flow rate. Again at a constant coolant flow rate, heat flux and inclination angle, the thermal resistance for square MHP shows much smaller value than that of circular MHP. Overall heat transfer coefficient for square MHP is maximed at vertical orientation.

Author(s):  
Daniel T. Pollock ◽  
Zehao Yang ◽  
John T. Wen

Multiple-evaporator vapor compression cycles may be used for distributed cooling of high heat-flux systems, such as arrays of high-power electronics. Under transient heating conditions, these systems must be carefully controlled to avoid critical heat flux (CHF) due to evaporator dryout. An active control strategy is presented that regulates two-phase flow quality in multiple evaporators in order to avoid critical quality under transient heating conditions. A two-loop control system is used, in which an outer loop uses model-based feedforward combined with evaporator wall temperature feedback to determine the necessary coolant flow rate to avoid CHF, while an inner loop uses system actuators (variable speed compressor, electronic expansion valves) to track to the desired flow rate. An advantage of this approach is that the inner-loop control handles the system complexity arising from pressure coupling and actuator nonlinearity. Additionally, the outer-loop quality control may be applied to other two-phase cooling schemes, for instance pumped systems, by providing coolant flow rate setpoints. Simulations and corresponding experimental controller validation were conducted using a three-evaporator vapor compression testbed with transient imposed heat-flux.


2011 ◽  
Vol 27 (2) ◽  
pp. 167-176 ◽  
Author(s):  
L.-H. Chien ◽  
Y.-C. Shih

ABSTRACTFlat heat pipes having mesh capillaries were investigated experimentally in this study. An apparatus was designed to test thermal performance of plate type copper water heat pipe having one or two layers of #50 or #80 mesh capillary structures with 5 to 50 W heat input. The working fluid, water, is charged in volumes equivalent to 25%, 33%, or 50% of the internal space. In addition to horizontal orientation, heat pipes were tested with the evaporator section elevated up to 40 degree inclination angle. Temperature distribution of the heat pipe was measured, and the evaporator, adiabatic and condensation resistances were calculated separately. The effects of mesh size, charge volume fraction, and inclination angle on thermal resistance were discussed. In general, the #80 mesh yielded lower thermal resistance than the #50 mesh. Inclination angle has a more significant effect on condenser than evaporator. Analysis of evaporation and condensation in flat heat pipes was conducted and semi-empirical correlations were derived. The present evaporation correlation predicts evaporation resistance between −20% and +30%, and the condensation correlation predicts most condensation resistance data within ±30% for 25% and 33% charge volume fraction.


Author(s):  
Mehdi Taslimifar ◽  
Maziar Mohammadi ◽  
Mohammad Hassan Saidi ◽  
Hossein Afshin ◽  
Mohammad Behshad Shafii ◽  
...  

In the present research an experimental investigation is performed to explore the effects of working fluid, heat input, ferrofluid concentration, magnets location, and inclination angle on the thermal performance of an Open Loop Pulsating Heat Pipe (OLPHP). Obtained results show that using ferrofluid can improve the thermal performance and applying a magnetic field on the water based ferrofluid decreases the thermal resistance. It shows that at an inclination angle of the OLPHP to be zero, the thermal performance of the present OLPHP reduces. Best heat transfer capability was achieved at 67.5 degree relative to horizontal axis for all of working fluids. Variation of the magnets location leads to a different thermal resistance in the OLPHP charged with ferrofluid.


2016 ◽  
Vol 851 ◽  
pp. 292-298
Author(s):  
Niti Kammuang-Lue ◽  
Deuansavanh Phommavongsa ◽  
Kritsada On-Ai ◽  
Phrut Sakulchangsatjatai ◽  
Pradit Terdtoon

Objective of this study is to experimentally investigate the effect of centrifugal accelerations on thermal resistance of the rotating closed-loop pulsating heat pipe (RCLPHP). The RCLPHPs were made of a copper tube with internal diameter of 1.50 and 1.78 mm and bent into flower’s petal-shape and arranged into a circle with 11 turns. The evaporator section located at the outer end of the bundle while the condenser section placed around the center of the RCLPHP with no adiabatic section. Both sections had an identical length of 50 mm. R123, and ethanol was filled as working fluid respectively. The RCLPHP was installed on the test rig and it was rotated by the DC motor at the centrifugal acceleration of 0.5, 1, 3, 5, 10, and 20 times of the gravitational acceleration considering at the connection between the evaporator and condenser section. Heat input was generated by electrical annular-plate heaters and varied from 30 to 50, 100, 150, and 200 W. Ceramic papers, wooden plate, and insulation sheet were consecutively attached on the outer side of the heaters in order to prevent the heat loss from the heater. It can be concluded that when the centrifugal acceleration increases, the thermal resistance continuously decreases since the condensate flows back to the evaporator section more rapidly.


2019 ◽  
Vol 12 (2) ◽  
pp. 90-97
Author(s):  
Basil Noori Merzah ◽  
Majid H. Majeed ◽  
Fouad A. Saleh

In this work, a system of a heat pipe is implemented to improve the performance of flat plate solar collector. The model is represented by square shape portion of the evaporator section of wicked heat pipe with a constant total length of 510 mm, and the evaporator section inclined by an angle of 30o. In this models the evaporator, adiabatic and condenser lengths are 140mm, 140mm, and 230mm respectively. The omitted energies from sunlight simulator are 200, 400, 600, 800 and 1000 W/m2 which is close to the normal solar energy in Iraq. The working fluid for all models is water with fill charge ratio of 240%. The efficiency of the solar collector is investigated with three values of condenser inlet water temperatures, namely (12, 16 and 20o C). The numerical result showed an optimum volume flow rate of cooling water in condenser at which the efficiency of collector is a maximum. This optimum agree well with the ASHRAE standard volume of flow rate for conventional tasting for flat plate solar collector. When the radiation incident increases the thermal resistance of wicked heat pipe is decreases, where the heat transfer from the evaporator to condenser increases. The numerical results showed the performance of solar collector with square shape evaporator greater than other types of evaporator as a ratio 15 %.


2011 ◽  
Vol 204-210 ◽  
pp. 2023-2026
Author(s):  
Ka Lin Su ◽  
Jing Liu ◽  
Jun Rong ◽  
Jun Hua Wan

A novel porous micro heat sink system was presented for dissipating high heat fluxes of electronic device. The flow and heat transfer of porous micro heat sink was investigated by experiment at the condition of high heat fluxes, and the results showed that the heat load of up to 280W was removed by the heat sink, and the heater junction temperature was 63.8°C at the coolant flow rate of 5.1cm3/s. The whole heat transfer coefficient of heat sink increased with the increases of coolant flow rate and heat load, and the maximal heat transfer coefficient was 33kW(m2.°C)-1 in the experiment. The minimum value of 0.19°C/W for whole thermal resistance of heat sink was achieved at flow rate of 5.1cm3/s, and increasing of coolant flow rate and heat fluxes could decrease the thermal resistance.


2020 ◽  
Vol 38 (1A) ◽  
pp. 88-104
Author(s):  
Anwar S. Barrak ◽  
Ahmed A. M. Saleh ◽  
Zainab H. Naji

This study is investigated the thermal performance of seven turns of the oscillating heat pipe (OHP) by an experimental investigation and CFD simulation. The OHP is designed and made from a copper tube with an inner diameter 3.5 mm and thickness 0.6 mm and the condenser, evaporator, and adiabatic lengths are 300, 300, and 210 mm respectively.  Water is used as a working fluid with a filling ratio of 50% of the total volume. The evaporator part is heated by hot air (35, 40, 45, and 50) oC with various face velocity (0.5, 1, and 1.5) m/s. The condenser section is cold by air at temperature 15 oC. The CFD simulation is done by using the volume of fluid (VOF) method to model two-phase flow by conjugating a user-defined function code (UDF) to the FLUENT code. Results showed that the maximum heat input is 107.75 W while the minimum heat is 13.75 W at air inlet temperature 35 oC with air velocity 0.5m/s. The thermal resistance decreased with increasing of heat input. The results were recorded minimum thermal resistance 0.2312 oC/W at 107.75 W and maximum thermal resistance 1.036 oC/W at 13.75W. In addition, the effective thermal conductivity increased due to increasing heat input.  The numerical results showed a good agreement with experimental results with a maximum deviation of 15%.


Author(s):  
D. Sugumar ◽  
Kek Kiong Tio

A micro heat pipe will operate effectively by achieving its maximum possible heat transport capacity only if it is to operate at a specific temperature, i.e., design temperature. In reality, micro heat pipe’s may be required to operate at temperatures different from the design temperature. In this study, the heat transport capacity of an equilateral triangle micro heat pipe is investigated. The micro heat pipe is filled optimally with working fluid for a specific design temperature and operated at different operating temperatures. For this purpose, water, pentane and acetone was selected as the working fluids. From the numerical results obtained, it shows that the optimal charge level of the micro heat pipe is dependent on the operating temperature. Furthermore, the results also shows that if the micro heat pipe is to be operated at temperatures other than its design temperature, its heat transport capacity is limited by the occurrence of flooding at the condenser section or dryout at the evaporator section, depending on the operating temperature and type of working fluid. It is observed that when the micro heat pipe is operated at a higher temperature than its design temperature, the heat transport capacity increases but limited by the onset of dryout at the evaporator section. However, the heat transport capacity decreases if it is to be operated at lower temperatures than its design temperature due to the occurrence of flooding at condenser end. From the results obtained, we can conclude that the performance of a micro heat pipe is decreased if it is to be operated at temperatures other than its design temperature.


Author(s):  
Zhigang Li ◽  
Jun Li ◽  
Liming Song ◽  
Qing Gao ◽  
Xin Yan ◽  
...  

The modern gas turbine is widely applied in the aviation propulsion and power generation. The rim seal is usually designed at the periphery of the wheel-space and prevented the hot gas ingestion in modern gas turbines. The high sealing effectiveness of rim seal can improve the aerodynamic performance of gas turbines and avoid of the disc overheating. Effect of outer fin axial gap of radial rim seal on the sealing effectiveness and fluid dynamics was numerically investigated in this work. The sealing effectiveness and fluid dynamics of radial rim seal with three different outer fin axial gaps was conducted at different coolant flow rates using three-dimensional Reynolds-Averaged Navier-Stokes (RANS) and SST turbulent model solutions. The accuracy of the presented numerical approach for the prediction of the sealing performance of the turbine rim seal was demonstrated. The obtained results show that the sealing effectiveness of radial rim seal increases with increase of coolant flow rate at the fixed axial outer fin gap. The sealing effectiveness increases with decrease of the axial outer fin gap at the fixed coolant flow rate. Furthermore, at the fixed coolant flow rate, the hot gas ingestion increases with the increase of the axial outer fin gap. This flow behavior intensifies the interaction between the hot gas and coolant flow at the clearance of radial rim seal. The preswirl coefficient in the wheel-space cavity is also illustrated to analyze the flow dynamics of radial rim seal at different axial outer fin gaps.