Non-Destructive Detection of Defects in Composite Boat Hulls

Author(s):  
A. S. Suratkar ◽  
A. Y. Sajjadi ◽  
K. Mitra

This paper demonstrates use of thermal imaging for nondestructive defect detection in a composite boat hull which covers a large area. There is a strong demand in the boat industry for a non-destructive method that can detect defects such as delamination, voids of air or fluid, cracks, acid, dry mat, and carbon fiber. These defects are always difficult to detect as they occur inside the walls of the boat. Currently, ultrasound and manual inspection methods are used to identify these defects. The manual checking technique is unscientific; furthermore the ultrasound method is not acceptable due to unsatisfactory results. Thermal imaging involves detecting infra-red radiation from a hot body; this is captured by a thermal imaging camera. A thermal heat gun is used to heat the walls of the boat hull. After heating for a specific time period, the walls of the boat start emitting radiation. Dry void attains the highest peak intensity value for short time heating followed by Acid. Other defects like carbon fiber, delamination, and dry mat took longer time to attain higher intensity value. The decay of radiations is also different for various types of defects. The maximum intensity decay occurs for dry void as compared to other defects. From the results obtained so far, it can be inferred that thermal imaging can distinctly differentiate the different kinds of defects, as well as the unaffected areas of the boat wall.

2010 ◽  
Vol 645-648 ◽  
pp. 559-562 ◽  
Author(s):  
Kun Yong Lee ◽  
Hisashi Miyazaki ◽  
Yoichi Okamoto ◽  
Jun Morimoto

We have detected defects micro-pipes and a cluster of impurities in semi-insulating 6H-SiC substrates using long-wavelength infrared thermal imaging camera (IR-camera) with 8 ~ 14 µm in non-destructive and non-contact. Also we have evaluated the thermal influence of defects on the entire substrates from the observation results of scanning laser microscope (SLM) and light scattering tomography (LST). Through the process, it was certificated that the defects in the substrates could be detected with relatively macroscopic scale (8  6 mm2). Moreover, through a temperature profile processing by a 0.1 K thermal resolution, we estimated thermal behavior of the defect areas in the 6H-SiC precisely. The IR-camera is considered as effective technique for evaluating the defects in the intermediate range between micro and macro scale.


Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4497
Author(s):  
Karmen Šibanc ◽  
Ivan Čuk ◽  
Maja Pajek ◽  
Igor Pušnik

Thermal imaging is used in various fields of industry and research to measure temperature and its possible differences. Since there is a lack of research and literature on palm temperatures and prevention of blisters on hands, our question was how palm temperature differs in human hands after different loads (Hang and Swing in Hang) for 30 s on a high bar. Thirty-eight students from the Faculty of Sport at the University of Ljubljana were measured with a high-quality thermal imaging camera. Palm temperatures were measured before the load was applied, immediately after and every 30 s for a period of 5 min after the load. Each hand was divided into nine different regions of interest (ROIs). Mean (XA), standard deviation (SD), maximum and minimum, and number of pixels were calculated. We found that there was no difference between the left and right hand. The temperature right after the load was applied decreased significantly for both loads and then increased above the level before the load was applied. After the static load, the temperature reached a constant higher level after 3 min. After the dynamic load, the temperatures continued to increase throughout the measurement period. Further investigation is needed to determine the time period in which the hand temperature reaches the temperature before the load is applied.


2017 ◽  
Vol 2 (87) ◽  
pp. 66-74
Author(s):  
J. Nowacki ◽  
N. Sieczkiewicz

Purpose: Analysis of non-destructive testing systems polymer composite in terms of current solutions in the area of methodology and devices. Analysis of contemporary standards for non-destructive testing of polymer composites established by ASTM. Analysis of Flir ONE camera capabilities in non-destructive testing composite carbon-epoxy composites. Design/methodology/approach: The thermal imaging tests of the carbon-epoxy composite discontinuity were carried out using a thermal imaging camera and Flir One accessory for an iOS phone. The tests were performed on carbon-epoxy composite samples measuring 100x100 mm. In order to simulate the discontinuity in a sample by the Resin Transfer Molding (RTM) method, a 30x30 mm PTFE film was inserted between the reinforcement layers. The thickness of the sample with discontinuity was 2 mm. Water was added to the selected sample sites. Samples were placed on a 50°C heated plate to record thermal images and thermal images combined with visual contours of samples with simulated defects. Area Calculator – SketchAndCalc Icalc, Inc. was used to describe the size and location of the defects. Findings: As a result of the tests, the use of the Flir One thermal imaging device in epoxycarbon composite discontinuity tests has been demonstrated, and a methodology has been proposed to measure geometrical features of defects. Research limitations/implications: The description of welded joint structure and mechanical properties was based on welding toughened steels by using an innovative welding method and a filler that has been proposed. Practical implications: The development of thermal imaging studies of polymer composite discontinuity using the Flir One thermal imaging camera and accessory with iOS opens up the possibility of conducting a basic inspection of composite materials in production plants, and even for simplicity – also in small laboratories. Originality/value: In order to improve the quality of imaging of small items using the Flir One mobile camera, the use of cheap and readily available lenses used in laser optics has been tested positively.


2012 ◽  
pp. 61-83 ◽  
Author(s):  
M. Ershov

According to the latest forecasts, it will take 10 years for the world economy to get back to “decent shape”. Some more critical estimates suggest that the whole western world will have a “colossal mess” within the next 5–10 years. Regulators of some major countries significantly and over a short time‑period changed their forecasts for the worse which means that uncertainty in the outlook for the future persists. Indeed, the intensive anti‑crisis measures have reduced the severity of the past problems, however the problems themselves have not disappeared. Moreover, some of them have become more intense — the eurocrisis, excessive debts, global liquidity glut against the backdrop of its deficit in some of market segments. As was the case prior to the crisis, derivatives and high‑risk operations with “junk” bonds grow; budget problems — “fiscal cliff” in the US — and other problems worsen. All of the above forces the regulators to take unprecedented (in their scope and nature) steps. Will they be able to tackle the problems which emerge?


2020 ◽  
Vol 35 (3) ◽  
Author(s):  
Tayyaba Gul Malik ◽  
Hina Nadeem ◽  
Eiman Ayesha ◽  
Rabail Alam

Objective: To study the effect of short-term use of oral contraceptive pills on intra-ocular pressures of women of childbearing age.   Methods: It was a comparative observational study, conducted at Arif memorial teaching hospital and Allied hospital Faisalabad for a period of six months. Hundred female subjects were divided into two groups of 50 each. Group A, included females, who had been taking oral contraceptive pills (OCP) for more than 6 months and less than 36 months. Group B, included 50 age-matched controls, who had never used OCP. Ophthalmic and systemic history was taken. Careful Slit lamp examination was performed and intraocular pressures (IOP) were measured using Goldman Applanation tonometer. Fundus examination was done to rule out any posterior segment disease. After collection of data, we analyzed and compared the intra ocular pressures between the two groups by using ANOVA in SPSS version 21.   Results: Average duration of using OCP was 14.9 months. There was no significant difference of Cup to Disc ratios between the two groups (p= 0.109). However, significant difference was noted between the IOP of OCP group and controls. (p=0.000). Conclusion: OCP significantly increase IOP even when used for short time period.


2021 ◽  
pp. 112067212110237
Author(s):  
Ari Leshno ◽  
Ori Stern ◽  
Yaniv Barkana ◽  
Noa Kapelushnik ◽  
Reut Singer ◽  
...  

Purpose: Accumulating evidence suggests that neuroinflammation and immune response are part of the sequence of pathological events leading to optic nerve damage in glaucoma. Changes in tissue temperature due to inflammation can be measured by thermographic imaging. We investigated the ocular surface temperature (OST) profile of glaucomatous eyes to better understand the pathophysiology of these conditions. Methods: Subjects diagnosed with glaucoma (primary open angle glaucoma [POAG] or pseudo exfoliation glaucoma [PXFG]) treated at the Sam Rothberg Glaucoma Center (11/2019–11/2020.) were recruited. Healthy subjects with no ocular disease served as controls. The Therm-App thermal imaging camera was used for OST acquisition. Room and body temperatures were recorded, and the mean temperatures of the medial cantus, lateral cantus, and cornea were calculated with image processing software. Results: Thermographic images were obtained from 52 subjects (52 eyes: 25 POAG and 27 PXFG) and 66 controls (66 eyes). Eyes with glaucoma had a significantly higher OST compared to controls (mean 0.9 ± 0.3°C, p < 0.005). The difference between the two groups remained significant after adjustment for age, sex, intraocular pressure (IOP) and room and body temperatures. Lens status and topical IOP-lowering medication did not significantly affect OST. A subgroup analysis revealed that the OST was higher among eyes with POAG compared to eyes with PXFG, but not significantly. Conclusions: Differences in the OST between glaucomatous and normal eyes strengthens current thinking that inflammation affects the pathophysiology of glaucoma. Longitudinal studies are warranted to establish the prognostic value of thermographic evaluations in these patients.


2021 ◽  
Author(s):  
Marc Debus ◽  
Jale Tosun

AbstractThe COVID-19 pandemic has forced governments to impose major restrictions on individual freedom in order to stop the spread of the virus. With the successful development of a vaccine, these restrictions are likely to become obsolete—on the condition that people get vaccinated. However, parts of the population have reservations against vaccination. While this is not a recent phenomenon, it might prove a critical one in the context of current attempts to manage the COVID-19 pandemic. Consequently, the task of designing policies suitable for attaining high levels of vaccination deserves enhanced attention. In this study, we use data from the Eurobarometer survey fielded in March 2019. They show that 39% of Europeans consider vaccines to cause the diseases which they should protect against, that 50% believe vaccines have serious side effects, that 32% think that vaccines weaken the immune system, and that 10% do not believe vaccines are tested rigorously before authorization. We find that—even when controlling for important individual-level factors—ideological extremism on both ends of the spectrum explains skepticism of vaccination. We conclude that policymakers must either politicize the issue or form broad alliances among parties and societal groups in order to increase trust in and public support for the vaccines in general and for vaccines against COVID-19 in particular, since the latter were developed in a very short time period and resulted—in particular in case of the AstraZeneca vaccine—in reservations because of the effectiveness and side effects of the new vaccines.


Author(s):  
Yudai Tamura ◽  
Tomohiro Sakamoto

Abstract Background Platypnoea–orthodeoxia syndrome (POS) is an uncommon condition characterized by dyspnoea and arterial desaturation in the standing or sitting position that improves in the supine position. Case summary We report two cases of POS caused by an atrial septal defect (ASD) and a patent foramen ovale (PFO). Both cases reported a recent decrease in body weight of more than 10 kg in a short time period. Transoesophageal echocardiography (TOE) with agitated saline bubble study revealed and a large amount of contrast bubble through the ASD (Patient 1) or the PFO (Patient 2) from the right atrium to the left atrium in the sitting position. Both patients were diagnosed by the finding of positional dyspnoea and the results of TOE using agitated saline bubble contrast. Discussion Taken together, their presentations suggest that weight loss in a short time period could be a pathogenic factor for POS.


1998 ◽  
Vol 27 (3) ◽  
pp. 351-369 ◽  
Author(s):  
MICHAEL NOBLE ◽  
SIN YI CHEUNG ◽  
GEORGE SMITH

This article briefly reviews American and British literature on welfare dynamics and examines the concepts of welfare dependency and ‘dependency culture’ with particular reference to lone parents. Using UK benefit data sets, the welfare dynamics of lone mothers are examined to explore the extent to which they inform the debates. Evidence from Housing Benefits data show that even over a relatively short time period, there is significant turnover in the benefits-dependent lone parent population with movement in and out of income support as well as movement into other family structures. Younger lone parents and owner-occupiers tend to leave the data set while older lone parents and council tenants are most likely to stay. Some owner-occupier lone parents may be relatively well off and on income support for a relatively short time between separation and a financial settlement being reached. They may also represent a more highly educated and highly skilled group with easier access to the labour market than renters. Any policy moves paralleling those in the United States to time limit benefit will disproportionately affect older lone parents.


Sign in / Sign up

Export Citation Format