Quality of Reamed Surface Using Serrated Blades as Compared to a Conventional Acetabular Reamer

Author(s):  
Annie Levasseur ◽  
Jérémie Ménard ◽  
Victor Songmené ◽  
Julio Fernandes ◽  
Yvan Petit

Background: Hip arthroplasty requires the preparation of the acetabular cavity to allow a proper contact between the bone and the implant. It is essential to allow osseointegration and long-term stability of the implant. The aim of this study was to conduct experimental testing to evaluate the quality of reamed surfaces using a serrated blade acetabular reamer as compared to a conventional rasp reamer. Method of Approach: Reaming tests were performed on a computerized numerical control tools machine at a rotational speed of 250 rpm and 3 different penetration speeds: 0.20 mm/s, 0.55 mm/s and 0.90 mm/s. For each reamer, a complete semi-hemispherical hole was perforated in 7 polyurethane samples. The reamed surfaces were digitized with a three-dimensional high resolution (40 μm) self-positioning laser scanner to carry out a quantitative analysis of the surface quality. Results: Results demonstrated that the cutting edge and the penetration speed influence the quality of the reamed surface. The serrated blade was found to reduce surface irregularities (ranging between 0.19 mm to 0.21 mm for the conventional rasp and between 0.07 mm and 0.12 mm for the serrated blades), and to reduce inaccuracies on the reamed cavity diameter (0.13 mm ± 0.05mm for the rasps and 0.06 mm ± 0.03mm for the serrated blade). Conclusions: The use of such tool by the surgeon may influence the stability of the acetabular implant and reduce the risks of revision surgery.

Author(s):  
B. Veeraswami ◽  
V. M. K. Naveen

In this paper a comprehensive study of stability related, and evidence based best practices of Bio-analytical stability on Bendroflumethiazide drug samples are studied. The proposed approach is very significant and essential for the drugs development process address the specify the acceptancy, purity, efficacy, prediction of strength and quality of the drugs. The stability study constituents several methods like Bench-Top, Auto-sampler, Freeze-Thaw, Dry-extract, Wet-extract, Short-term, long-Term stability studies at relative intervals results the complete stability information about the drug under the proposed and validated method. There ported out comes of this methos shows this drug have good stability according to ICH guidelines.


1979 ◽  
Vol 42 (04) ◽  
pp. 1135-1140 ◽  
Author(s):  
G I C Ingram

SummaryThe International Reference Preparation of human brain thromboplastin coded 67/40 has been thought to show evidence of instability. The evidence is discussed and is not thought to be strong; but it is suggested that it would be wise to replace 67/40 with a new preparation of human brain, both for this reason and because 67/40 is in a form (like Thrombotest) in which few workers seem to use human brain. A �plain� preparation would be more appropriate; and a freeze-dried sample of BCT is recommended as the successor preparation. The opportunity should be taken also to replace the corresponding ox and rabbit preparations. In the collaborative study which would be required it would then be desirable to test in parallel the three old and the three new preparations. The relative sensitivities of the old preparations could be compared with those found in earlier studies to obtain further evidence on the stability of 67/40; if stability were confirmed, the new preparations should be calibrated against it, but if not, the new human material should receive a calibration constant of 1.0 and the new ox and rabbit materials calibrated against that.The types of evidence available for monitoring the long-term stability of a thromboplastin are discussed.


2019 ◽  
Vol 952 (10) ◽  
pp. 47-54
Author(s):  
A.V. Komissarov ◽  
A.V. Remizov ◽  
M.M. Shlyakhova ◽  
K.K. Yambaev

The authors consider hand-held laser scanners, as a new photogrammetric tool for obtaining three-dimensional models of objects. The principle of their work and the newest optical systems based on various sensors measuring the depth of space are described in detail. The method of simultaneous navigation and mapping (SLAM) used for combining single scans into point cloud is outlined. The formulated tasks and methods for performing studies of the DotProduct (USA) hand-held laser scanner DPI?8X based on a test site survey are presented. The accuracy requirements for determining the coordinates of polygon points are given. The essence of the performed experimental research of the DPI?8X scanner is described, including scanning of a test object at various scanner distances, shooting a test polygon from various scanner positions and building point cloud, repeatedly shooting the same area of the polygon to check the stability of the scanner. The data on the assessment of accuracy and analysis of research results are given. Fields of applying hand-held laser scanners, their advantages and disadvantages are identified.


2018 ◽  
Vol 86 (13) ◽  
pp. 301-314
Author(s):  
Maren Rastedt ◽  
Julian Büsselmann ◽  
Tomas Klicpera ◽  
Karsten Reinwald ◽  
Nadine Pilinski ◽  
...  

2018 ◽  
Author(s):  
Anne Boynard ◽  
Daniel Hurtmans ◽  
Katerina Garane ◽  
Florence Goutail ◽  
Juliette Hadji-Lazaro ◽  
...  

Abstract. This paper assesses the quality of IASI/Metop-A (IASI-A) and IASI/Metop-B (IASI-B) ozone (O3) products (total and partial O3 columns) retrieved with the Fast Optimal Retrievals on Layers for IASI Ozone (FORLI-O3) v20151001 software for nine years (2008–2017) through an extensive inter-comparison and validation exercise using independent observations (satellite, ground-based and ozonesonde). IASI-A and IASI-B Total O3 Columns (TOCs) are generally consistent, with a global mean difference less than 0.3 % for both day- and nighttime measurements, IASI-A being slightly higher than IASI-B. A global difference less than 2.4 % is found for the tropospheric (TROPO) O3 column product (IASI-A being lower than IASI-B), which is partly due to a temporary issue related to IASI-A viewing angle in 2015. Our validation shows that IASI-A and IASI-B TOCs are consistent with GOME-2, Dobson, Brewer and SAOZ retrieved ones, with global mean differences in the range 0.1–2 % depending on the instruments. The IASI-A and ground-based TOC comparison for the period 2008–July 2017 shows good long-term stability (negative trends within 3 % decade−1). The comparison results between IASI-A and IASI-B against smoothed ozonesonde partial O3 columns vary in altitude and latitude, with maximum standard deviation for the 300–150 hPa column (20–40 %) due to strong ozone variability and a priori uncertainty. The worst agreement with the ozonesondes and with UV-vis retrieved TOC [satellite and ground] is found at the southern high latitudes. Compared to ozonesonde data, IASI-A and IASI-B O3 products overestimate the O3 abundance in the stratosphere (up to 20 % for the 150–25 hPa column) and underestimates the O3 abundance in the troposphere (within 10 % for the mid-latitudes and ~ 18 % for the tropics). Based on the period 2011–2016, non-significant drift is found for the northern hemispheric tropospheric columns while a small drift prevails for the period before 2011.


2021 ◽  
Vol 15 (1) ◽  
pp. 2
Author(s):  
Cristina Martín-Sabroso ◽  
Mario Alonso-González ◽  
Ana Fernández-Carballido ◽  
Juan Aparicio-Blanco ◽  
Damián Córdoba-Díaz ◽  
...  

Accumulation of cystine crystals in the cornea of patients suffering from cystinosis is considered pathognomonic and can lead to severe ocular complications. Cysteamine eye drop compounded formulations, commonly prepared by hospital pharmacy services, are meant to diminish the build-up of corneal cystine crystals. The objective of this work was to analyze whether the shelf life proposed for six formulations prepared following different protocols used in hospital pharmacies is adequate to guarantee the quality and efficacy of cysteamine eye drops. The long-term and in-use stabilities of these preparations were studied using different parameters: content of cysteamine and its main degradation product cystamine; appearance, color and odor; pH and viscosity; and microbiological analysis. The results obtained show that degradation of cysteamine was between 20% and 50% after one month of storage in the long-term stability study and between 35% and 60% in the in-use study. These data confirm that cysteamine is a very unstable molecule in aqueous solution, the presence of oxygen being the main degradation factor. Saturation with nitrogen gas of the solutions offers a means of reducing cysteamine degradation. Overall, all the formulae studied presented high instability at the end of their shelf life, suggesting that their clinical efficacy might be dramatically compromised.


2019 ◽  
Vol 25 (2) ◽  
pp. 9-18 ◽  
Author(s):  
A. A. Cherny ◽  
A. N. Kovalenko ◽  
S. S. Bilyk ◽  
A. O. Denisov ◽  
A. V. Kazemirskiy ◽  
...  

The aim of this study was the assessment of early outcomes of patient-specific three-dimensional titanium cones with specified porosity parameters to compensate for extensive metaphysical-diaphyseal bone defects in RTKA.Materials and Methods. Since 2017 till 2019 30 patient-specific titanium cones (12 femoral and 18 tibial) implanted during 26 RTKAS. Clinical outcomes evaluated using KSS, WOMAC and fjS-12 scoring systems on average 10 (2–18) months after surgery. At the same time the stability of implant fixation analyzed using frontal, lateral and axial knee roentgenograms.Results. During all procedures there were no technical difficulties in positioning and implantation of custom-made titanium cones. At the time of preparation of the publication, none of the patients had indications for further surgical intervention, as well as intra- and postoperative complications. Six months after surgery all scores improved significantly: KSS from 23 (2–42, SD 19.96) to 66.5 (62–78, SD 7.68), WOMAC from 59 (56–96, SD 28.31) to 32.25 (19–46, SD 11.76), the index FJS-12 was 29.16 points (0–68.75, SD 30.19). The average scores continued to improve up to 18 months: KSS — 97.5 (88–108, SD 9.14), WOMAC — 16.5 (9–24, SD 6.45), FJS-12 — 45.85 (25–75, SD 22.03). No radiolucent lines were noticed during this period of observation.Conclusion. The original additive technology of designing and producing patient-specific titanium cones for compensation of extensive metaphyseal-diaphyseal bone defects in RTKA is a valid solution at least in the short term. A longer follow-up period is required to assess its medium-and long-term reliability compared to existing alternative surgical solutions.


2020 ◽  
Author(s):  
Haozhen Dou ◽  
Mi Xu ◽  
Baoyu Wang ◽  
Zhen Zhang ◽  
Guobin Wen ◽  
...  

Abstract Cellular membranes provide ideal archetypes for molecule or ion separations with sub-angstrom scale precision, which are featured with both extremely high permeability and selectivity due to the well-defined membrane protein channels. However, the development of bioinspired membranes with artificial channels for sub-angstrom scale ethylene/ethane (0.416 nm / 0.443 nm) separation remains an uncharted territory and a significant challenge. Herein, a bioinspired nano-ordered liquid membrane is constructed by a facile ion/molecule self-assembly strategy for highly efficient ethylene/ethane separation, which mimics the structure of cellular membrane elegantly and possesses plenty of three-dimensional (3D) nanochannels. The elaborate regulation of non-covalent interactions by optimizing the ion/molecule compositions within membrane confers the nano-ordered liquid structure with interpenetrating and bi-continuous apolar domains and polar domains, which results in the formation of regular carrier wires and enormous 3D interconnected ethylene transport nanochannels. By virtue of these 3D nanochannels, the bioinspired nano-ordered liquid membrane manifests simultaneously super-high selectivity, excellent permeance and long-term stability, which exceeds previously reported ethylene/ethane separation membranes. This methodology in this work for construction of bioinspired membrane with tunable 3D nanochannels through ion/molecule self-assembly will enlighten the design and development of high-performance separation membranes for angstrom/sub-angstrom scale ion or molecule separations.


2013 ◽  
Vol 23 (11) ◽  
pp. 2129-2154 ◽  
Author(s):  
HÉLÈNE BARUCQ ◽  
JULIEN DIAZ ◽  
VÉRONIQUE DUPRAT

This work deals with the stability analysis of a one-parameter family of Absorbing Boundary Conditions (ABC) that have been derived for the acoustic wave equation. We tackle the problem of long-term stability of the wave field both at the continuous and the numerical levels. We first define a function of energy and show that it is decreasing in time. Its discrete form is also decreasing under a Courant–Friedrichs–Lewy (CFL) condition that does not depend on the ABC. Moreover, the decay rate of the continuous energy can be determined: it is exponential if the computational domain is star-shaped and this property can be illustrated numerically.


2021 ◽  
pp. 1-27
Author(s):  
Yichen Bao ◽  
Kai Liu ◽  
Quan Zheng ◽  
Lulu Yao ◽  
Yufu Xu

Abstract Pickering emulsion is a new type of stable emulsion made by ultra-fine solid particles instead of traditional surfactants as stabilizers, which has received widespread attention in recent years. The preparation methods of stator-rotor homogenization, high-pressure homogenization, and ultrasonic emulsification were compared with others in this work. The main factors affecting the stability of Pickering emulsion are the surface humidity of the solid particles, the polarity of the oil phase, and the oil-water ratio. These factors could affect the nature of the solid particles, the preparation process of Pickering emulsion and the external environment. Consequently, the long-term stability of Pickering emulsion is still a challenge. The tribological investigations of Pickering emulsion were summarized, and the multifunctional Pickering emulsion shows superior prospects for tribological applications. Moreover, the latest development of Pickering emulsion offers a new strategy for smart lubrication in the near future.


Sign in / Sign up

Export Citation Format

Share Document