Computational Human Torso Model Validation for Frontal Blunt Trauma

Author(s):  
Carolyn E. Hampton ◽  
Michael Kleinberger

Recent research on behind-armor blunt trauma (BABT) has focused on the personal protection offered by lightweight armor. A finite element analysis was performed to improve the biofidelity of the US Army Research Laboratory (ARL) human torso model to prepare for simulating blunt chest impacts and BABT. The overly stiff linear elastic material models for the torso were replaced with material characterizations drawn from current literature. FE torso biofidelity was determined by comparing peak force, force-compression, peak compression, and energy absorption data with cadaver responses to a 23.5 kg pendulum impacting at the sternum at 6.7 m/s. Nonlinear foam, viscous foam, soft rubbers, fibrous hyperelastic rubbers, and low moduli elastic material were considered as material models for the flesh, organs, and bones. Simulations modifying one tissue type revealed that the flesh characterization was most crucial for predicting compression and force, followed closely by the organs characterizations. Combining multiple tissue modifications allowed the FE torso to mimic the cadaveric torsos by reducing peak force and increasing chest compression and energy absorption. Limitations imposed by the Lagrangian finite element approach are discussed with potential workarounds described. Proposed future work is split between considering additional impact scenarios accounting for position and biomaterial variability.

2021 ◽  
pp. 073168442199086
Author(s):  
Yunfei Qu ◽  
Dian Wang ◽  
Hongye Zhang

The double V-wing honeycomb can be applied in many fields because of its lower mass and higher performance. In this study, the volume, in-plane elastic modulus and unit cell area of the double V-wing honeycomb were analytically derived, which became parts of the theoretical basis of the novel equivalent method. Based on mass, plateau load, in-plane elastic modulus, compression strain and energy absorption of the double V-wing honeycomb, a novel equivalent method mapping relationship between the thickness–width ratio and the basic parameters was established. The various size factor of the equivalent honeycomb model was denoted as n and constructed by the explicit finite element analysis method. The mechanical properties and energy absorption performance for equivalent honeycombs were investigated and compared with hexagonal honeycombs under dynamic impact. Numerical results showed a well coincidence for each honeycomb under dynamic impact before 0.009 s. Honeycombs with the same thickness–width ratio had similar mechanical properties and energy absorption characteristics. The equivalent method was verified by theoretical analysis, finite element analysis and experimental testing. Equivalent honeycombs exceeded the initial honeycomb in performance efficiency. Improvement of performance and weight loss reached 173.9% and 13.3% to the initial honeycomb. The double V-wing honeycomb possessed stronger impact resistance and better load-bearing capacity than the hexagonal honeycomb under impact in this study. The equivalent method could be applied to select the optimum honeycomb based on requirements and improve the efficiency of the double V-wing honeycomb.


2013 ◽  
Vol 42 (4) ◽  
pp. 843-857 ◽  
Author(s):  
Maximilian Eder ◽  
Stefan Raith ◽  
Jalil Jalali ◽  
Alexander Volf ◽  
Markus Settles ◽  
...  

Author(s):  
Joonas Ponkala ◽  
Mohsin Rizwan ◽  
Panos S. Shiakolas

The current state of the art in coronary stent technology, tubular structures used to keep the lumen open, is mainly populated by metallic stents coated with certain drugs to increase biocompatibility, even though experimental biodegradable stents have appeared in the horizon. Biodegradable polymeric stent design necessitates accurate characterization of time dependent polymer material properties and mechanical behavior for analysis and optimization. This manuscript presents the process for evaluating material properties for biodegradable biocompatible polymeric composite poly(diol citrate) hydroxyapatite (POC-HA), approaches for identifying material models and three dimensional solid models for finite element analysis and fabrication of a stent. The developed material models were utilized in a nonlinear finite element analysis to evaluate the suitability of the POC-HA material for coronary stent application. In addition, the advantages of using femtosecond laser machining to fabricate the POC-HA stent are discussed showing a machined stent. The methodology presented with additional steps can be applied in the development of a biocompatible and biodegradable polymeric stents.


2021 ◽  
Author(s):  
Richárd Horváth ◽  
Vendel Barth ◽  
Viktor Gonda ◽  
Mihály Réger ◽  
Imre Felde

Abstract In this paper, we study the energy absorption of metamaterials composed of unit cells whose special geometry makes the cross-sectional area and the volume of the bodies generated from them constant (for the same enclosing box dimensions). After a parametric description of such special geometries, we analyzed by finite element analysis the deformation of the metamaterials we have designed during compression. We 3D printed the designed metamaterials from plastic to subject them to real compression. The results of the finite element analysis were compared with the real compaction results. Then, for each test specimen, we plotted its compaction curve. By fitting a polynomial to the compaction curves and integrating it (area under the curve), the energy absorption of the samples can be obtained. As a result of these investigations, we drew a conclusion about the relationship between energy absorption and cell number.


2006 ◽  
Vol 129 (1) ◽  
pp. 58-65 ◽  
Author(s):  
B. Scott Kessler ◽  
A. Sherif El-Gizawy ◽  
Douglas E. Smith

The accuracy of a finite element model for design and analysis of a metal forging operation is limited by the incorporated material model’s ability to predict deformation behavior over a wide range of operating conditions. Current rheological models prove deficient in several respects due to the difficulty in establishing complicated relations between many parameters. More recently, artificial neural networks (ANN) have been suggested as an effective means to overcome these difficulties. To this end, a robust ANN with the ability to determine flow stresses based on strain, strain rate, and temperature is developed and linked with finite element code. Comparisons of this novel method with conventional means are carried out to demonstrate the advantages of this approach.


Author(s):  
Ben Mann ◽  
Kurtis Ford ◽  
Mike Neilsen ◽  
Dan Kammler

Abstract Ceramic to metal brazing is a common bonding process used in many advanced systems such as automotive engines, aircraft engines, and electronics. In this study, we use optimization techniques and finite element analysis utilizing viscoplastic and thermo-elastic material models to find an optimum thermal profile for a Kovar® washer bonded to an alumina button that is typical of a tension pull test. Several active braze filler materials are included in this work. Cooling rates, annealing times, aging, and thermal profile shapes are related to specific material behaviors. Viscoplastic material models are used to represent the creep and plasticity behavior in the Kovar® and braze materials while a thermo-elastic material model is used on the alumina. The Kovar® is particularly interesting because it has a Curie point at 435°C that creates a nonlinearity in its thermal strain and stiffness profiles. This complex behavior incentivizes the optimizer to maximize the stress above the Curie point with a fast cooling rate and then favors slow cooling rates below the Curie point to anneal the material. It is assumed that if failure occurs in these joints, it will occur in the ceramic material. Consequently, the maximum principle stress of the ceramic is minimized in the objective function. Specific details of the stress state are considered and discussed.


Sign in / Sign up

Export Citation Format

Share Document