Analysis of Triangular Microchannel Under Forced Convection Heat Transfer Condition for Laminar Flow Condition

Author(s):  
D. A. Kamble ◽  
B. S. Gawali

Micro-convection is a strategic area in transport phenomena, since it is the basis for a wide range of miniaturized high-performance heat transfer applications. Surface area is one of the important parameter for high flux heat transfer in microchannel performance. This experimental study deals with heat transfer using triangular microchannel having hydraulic diameters of 321μm and 289μm. Experimentation is carried out for triangular microchannel set for different heat input and flow rate condition. Triangular microchannel are manufactured with EDM technology. Testing of microchannel under laminar flow is considered with different tip angle, spacing, and length of microchannels. The different microchannels made up of copper material with 29 microchannel each having three different sets of length of 50 mm, 70 mm and 90 mm respectively. Tip angles for triangular microchannel is varied 50 ° and 60 ° with width of 30 mm each respectively are analyzed numerically. Spacing between triangular microchannels is also varied and 300μm and 400μm are considered for the analysis. Water flow rate is considered laminar flow. The flow rate of water is varied from 0.0167 kg/sec to 0.167 kg/sce to carry away heat. It is observed that as hydraulic diameters increase the heat transfer coefficient decreases. As the heat input to microchannel increases from 10 Watt to 100 Watt the temperature drop across varies from 2° C to 22°C as water flow rate increases. The numerical analysis is done using computer C programming. Experimental result differ from theoretical for temperature drop with variation of 2°C to 5°C. It is also observed that in all triangular microchannels its geometry i.e. tip angle and hydraulic diameter are dominant parameters which influences on rate of heat transfer. With increasing channel depth, increases flow passage area therefore enhances heat transfer sufficiently. From experimentation a Nu number correlation is proposed with considering tip angle, length, spacing of microchannel and other related parameters.

Author(s):  
Sun-Joon Byun ◽  
Sang-Jae Lee ◽  
Jae-Min Cha ◽  
Zhen-Huan Wang ◽  
Young-Chul Kwon

This study presents the comparison of heat transfer capacity and pressure drop characteristics between a basic fin-tube heat exchanger and a modified heat exchanger with the structural change of branch tubes and coiled turbulators. All experiments were carried out using an air-enthalpy type calorimeter based on the method described in ASHRAE standards, under heat exchanger experimental conditions. 14 different kinds of heat exchangers were used for the experiment. Cooling and heating capacities of the turbulator heat exchanger were excellent, compared to the basic one. As the insertion ratio of the coiled turbulator and the number of row increased, the heat transfer performance increased. However, the capacity per unit area was more effective in 4 rows than 6 rows, and the cooling performance of the 6 row turbulator heat exchanger (100% turbulator insert ratio) was down to about 6% than that of 4 row one. As the water flow rate and the turbulator insertion ratio increased, the pressure drop of the water side increased. This trend was more pronounced in 6 rows. In the cooling condition, the pressure drop on the air side was slightly increased due to the generation of condensed water, but was insignificant under the heating condition. The power consumption of the pump was more affected by the water flow rate than the coiled turbulator. The equivalent hydraulic diameter of a tube by the turbulator was reduced and then the heat transfer performance was improved. Thus, the tube diameter was smaller, the heat flux was better.


Energies ◽  
2020 ◽  
Vol 13 (14) ◽  
pp. 3589
Author(s):  
Shaowu Yin ◽  
Feiyang Xue ◽  
Xu Wang ◽  
Lige Tong ◽  
Li Wang ◽  
...  

Experimental heat transfer equipment with a buried tube granular bed was set up for waste heat recovery of flue gas. The effects of flue gas inlet temperature (1096.65–1286.45 K) and cooling water flow rate (2.6–5.1 m3/h) were studied through experiment and computational fluid dynamics’ (CFD) method. On the basis of logarithmic mean temperature difference method, the total heat transfer coefficient of the granular bed was used to characterize its heat transfer performance. Experimental results showed that the waste heat recovery rate of the equipment exceeded 72%. An increase in the cooling water flow rate and inlet gas temperature was beneficial to recovering waste heat. The cooling water flow rate increases from 2.6 m3/h to 5.1 m3/h and the recovery rate of waste heat increases by 1.9%. Moreover, the heat transfer coefficient of the granular bed increased by 4.4% and the inlet gas temperature increased from 1096.65 K to 1286.45 K. The recovery rate of waste heat increased by 1.7% and the heat transfer coefficient of the granular bed rose by 26.6%. Therefore, experimental correlations between the total heat transfer coefficient of a granular bed and the cooling water flow rate and inlet temperature of dusty gas were proposed. The CFD method was used to simulate the heat transfer in the granular bed, and the effect of gas temperature on the heat transfer coefficient of granular bed was studied. Results showed that the relative error was less than 2%.


1982 ◽  
Vol 68 (8) ◽  
pp. 974-981 ◽  
Author(s):  
Natsuo HATTA ◽  
Jun-ichi KOKADO ◽  
Koichi HANASAKI ◽  
Hirohiko TAKUDA ◽  
Masaharu NAKAZAWA

2021 ◽  
Vol 35 (4) ◽  
pp. 24-32
Author(s):  
Jae Geun Jo ◽  
Chi Young Lee

In this study, the thermal radiation attenuation performance of water mist was investigated using twin-fluid atomizers. The water and air flow rates of Small atomizer were 36~105 g/min and 10~30 L/min, whereas those of Large atomizer were 37~300 g/min and 20~60 L/min, respectively. In the present experimental range, the thermal radiation attenuation of Small atomizer and Large atomizer were 6.1~11.9% and 5.2~14.6%, respectively. With the increase in water and air flow rates, the thermal radiation attenuation increased, and under similar water and air flow rate conditions, Small atomizer showed higher thermal radiation attenuation than Large atomizer. Based on the present experimental data, it was found that the air (gas) discharge area is a potentially important factor in determining the thermal radiation attenuation performance. Additionally, through the analysis of thermal radiation attenuation per unit water flow rate, it was confirmed that the twin-fluid atomizer can result in higher thermal radiation attenuation than the single-fluid atomizer under the same water flow rate condition.


2021 ◽  
pp. 263-263
Author(s):  
Chongju Hu ◽  
Dali Yu ◽  
Meisheng He ◽  
Taosheng Li ◽  
Jie Yu

Lithium heat pipe has broad applications in heat pipe cooled reactors and hypersonic vehicles due to its ultra-high working temperature which is around 1700 K. In this paper, a lithium heat pipe based experimental facility has been designed to test the heat transfer performance of the lithium heat pipe. A simplified mathematical model of heat pipe has been implemented into a CFD approach, which is used to verify the design of lithium heat pipe and its experimental facility. Results showed that the CFD approach is in good agreements with some well-known existing models and experimental data, and deviation between the results is within 5% range. The adjustment range of mixed gas thermal resistance and cooling water flow rate was obtained by analyzing the effects of different cooling conditions on the performance of the experimental facility. It is necessary to ensure the cooling water flow rate is above 0.11l/h to prevent water boiling when the heating power is10kW around, and the optimal proportion of helium is 70% -90%.The operation characteristics of the lithium heat pipe under unsteady state with varying heating power were simulated numerically. The results show that the proportion of helium must be less than 60% for normal operation of the lithium heat pipe. This work provides a reference and numerical verification for the design of lithium heat pipe based experimental facility, which can be used to reveal the heat transfer mechanisms of the lithium heat pipe during the experiment.


Author(s):  
Yi Pan ◽  
Jeffrey Thomas ◽  
Chris Propes

Abstract Metal matrix composites (MMCs) can be manufactured by infiltrating a melting matrix alloy into hard powders — such as silicon carbide and tungsten carbide — loaded in a graphite mold and quenched to achieve a specific quenching temperature profile for proper solidification. Water quench is a widely used quenching technique within the aluminum and steel industry. It is more common to apply numerical simulation to optimize process parameters and help improve product quality, which depends upon reliable boundary conditions (e.g., heat flux or heat transfer coefficient); however, heat transfer coefficient changes with surface temperature and water flow rate. Moreover, the heat transfer coefficient in the discussed manufacturing process was never quantified. A combined experimental and simulation method to investigate heat transfer coefficient of the external surface of the graphite mold associated with water quenching is proposed. Firstly, the heat flux from the graphite mold is measured, which varies with water flow rate, mold surface temperature, nozzle arrangement, and water flow pattern. Without modifying the hardware design, this study focuses on the effects of water flow rate and mold surface temperature on surface heat flux. Secondly, the temperature distribution within the mold is used to inversely determine the heat transfer coefficient by solving an inversed optimization problem.


Author(s):  
Yasuo Koizumi ◽  
Tomoyuki Suzuki ◽  
Hiroyasu Ohtake

The influence of particle introduction into a subcooled water flow on boiling heat transfer and critical heat flux (CHF) was examined. When the water velocity was low, the particles crowded on the bottom wall of the flow channel and flowed just like sliding on the wall. When the water velocity was high, the particles were well dispersed in the water flow. In the non-boiling region, the heat transfer was augmented by the introduction of the particles into the water flow. As the introduction of the particles were increased, the augmentation was also increased in the high water flow rate region. However, it was independent upon the particle introduction rate in the low water flow rate region. The onset of boiling was delayed by the particle inclusion. The boiling heat transfer was enhanced by the particles. However, it was rather decreased in the high heat flux fully-developed-boiling region. The CHF was decreased by the particle inclusion in the low water flow region and was not affected in the high water flow region.


Science ◽  
2019 ◽  
Vol 366 (6462) ◽  
pp. 226-231 ◽  
Author(s):  
Chuan Xia ◽  
Yang Xia ◽  
Peng Zhu ◽  
Lei Fan ◽  
Haotian Wang

Hydrogen peroxide (H2O2) synthesis generally requires substantial postreaction purification. Here, we report a direct electrosynthesis strategy that delivers separate hydrogen (H2) and oxygen (O2) streams to an anode and cathode separated by a porous solid electrolyte, wherein the electrochemically generated H+ and HO2– recombine to form pure aqueous H2O2 solutions. By optimizing a functionalized carbon black catalyst for two-electron oxygen reduction, we achieved >90% selectivity for pure H2O2 at current densities up to 200 milliamperes per square centimeter, which represents an H2O2 productivity of 3.4 millimoles per square centimeter per hour (3660 moles per kilogram of catalyst per hour). A wide range of concentrations of pure H2O2 solutions up to 20 weight % could be obtained by tuning the water flow rate through the solid electrolyte, and the catalyst retained activity and selectivity for 100 hours.