A slant removal technique for document page

2013 ◽  
Author(s):  
Ergina Kavallieratou
Author(s):  
K.A. Mohammad ◽  
L.J. Liu ◽  
S.F. Liew ◽  
S.F. Chong ◽  
D.G. Lee ◽  
...  

Abstract The paper focuses on the pad contamination defect removal technique. The defect is detected at the outgoing inspection step. The failure analysis results showed that the defect is Fluorine type contamination. The failure analysis indicated many source contributors mainly from Fluorine based processes. The focus is in the present work is in the rework method for the removal of this defect. The combination of wet and dry etch processing in the rework routine is utilized for the removal of the defect and preventive action plans for in-line were introduced and implemented to avoid this event in the future. The reliability of the wafer is verified using various tests including full map electrical, electrical sort, gate oxide breakdown (GOI) and wafer reliability level, passivation quick kill to ensure the integrity of the wafer after undergoing the rework routine. The wafer is monitored closely over a period of time to ensure it has no mushroom defect.


Author(s):  
M. Agnello ◽  
M. Vottero ◽  
P. Bertapelle

Abstract Background Up to 7.5% of tined-lead removals in patients having sacral neuromodulation (SNM) therapy are associated with a lead breakage. It is still unclear what adverse effects can be caused by unretrieved fragments. The aim of our study was to describe the lead removal technique we have been using for the last 2 years in our centre. Methods We retrospectively enrolled patients who had lead removal between January 2018 and January 2020 using our standardized technique. The novelty of the technique is in the use of the straight stylet, which is available in the quadripolar tined-lead kit. The stylet gives the electrode greater stiffness, reducing interactions with surrounding tissues and probability of damage or breakage during removal. Results In 59 patients (42 women, mean age 57.2 years [range 40–79 years]) the lead was removed using our standardized technique. In 44 of 59 patients, the tined-lead was removed within 2 months from the SNM-test, due to lack of beneficial effects. In 15 patients the electrode was removed because of failure of definitive implantation. Meantime from definitive implantable pulse generator (IPG) implantation to lead removal was 67.9 months. We recorded only 1 case of lead-breakage during removal: a female patient with a non-tined lead fixed on sacral bone, placed 18 years previously using an open technique. Conclusions Lead breakage during removal is not uncommon and adverse effects of retained fragments may occur. Our technique has been safely used for the last 2 years in our centre, with no episodes of lead breakage or retained fragments, except for one non-tined electrode.


Sensors ◽  
2021 ◽  
Vol 21 (11) ◽  
pp. 3926
Author(s):  
Juping Liu ◽  
Shiju Wang ◽  
Xin Wang ◽  
Mingye Ju ◽  
Dengyin Zhang

Remote sensing (RS) is one of the data collection technologies that help explore more earth surface information. However, RS data captured by satellite are susceptible to particles suspended during the imaging process, especially for data with visible light band. To make up for such deficiency, numerous dehazing work and efforts have been made recently, whose strategy is to directly restore single hazy data without the need for using any extra information. In this paper, we first classify the current available algorithm into three categories, i.e., image enhancement, physical dehazing, and data-driven. The advantages and disadvantages of each type of algorithm are then summarized in detail. Finally, the evaluation indicators used to rank the recovery performance and the application scenario of the RS data haze removal technique are discussed, respectively. In addition, some common deficiencies of current available methods and future research focus are elaborated.


2013 ◽  
Vol 24 (5) ◽  
pp. 482-486 ◽  
Author(s):  
Marili Doro Andrade Deonizio ◽  
Gilson Blitzkow Sydney ◽  
Antonio Batista ◽  
Roberto Pontarolo ◽  
Paulo Ricardo Bittencourt Guimarães ◽  
...  

This study evaluated the influence of apical patency, root filling removal technique and cleaning of the apical foramen, concerning the amount of debris extruded during root canal retreatment. Forty mandibular incisors were randomly assigned to 4 groups - GIM (n=10), GIIM (n=10), GIPT (n=10) and GIIPT (n=10), which were named according to leaving (I) or not (II) apical patency during canal preparation and filling removal technique (manual - M or ProTaper system - PT). After filling material removal, each specimen of each group had the apical foramen cleaned by sizes 15, 20 and 25 instruments, generating 12 subgroups: GIM15, GIM20, GIM25, GIIM15, GIIM20, GIIM25, GIPT15, GIPT20, GIPT25, GIIPT15, GIIPT20 and GIIPT25. Extruded filling debris was collected by a Milipore filtration system, an HV-durapore, 0.45 µm pore filter with a 25 mm diameter. The filters were weighed before and after the collection on an analytical scale (10–5 g), and the difference was calculated. The mean weight of extruded filling debris was analyzed statistically by Kruskal-Wallis and Friedman ANOVA tests (α=0.05). The mean values found in the groups (in mg) were: GIM (0.95±0.94), GIIM (0.47±0.62), GIPT (0.30±0.31) and GIIPT (0.32±0.44). There was no statistically significant difference among any of the groups or subgroups (p>0.05). ProTaper provided the smallest amount of extruded filling material, regardless of presence or absence of apical patency, followed by manual technique, without and with apical patency. Additional amounts of debris were collected during cleaning of the apical foramen, regardless of the instrument, presence/absence of patency or root filling removal technique.


2007 ◽  
Vol 40 (4) ◽  
pp. 675-683 ◽  
Author(s):  
Cristy L. Azanza Ricardo ◽  
Mirco D'Incau ◽  
Paolo Scardi

A new procedure is proposed to determine sub-surface residual stress gradients by laboratory X-ray diffraction measurements at different depths using a chemical layer-removal technique. The standard correction algorithm for stress relaxation due to layer removal is improved by including corrections for X-ray absorption, and by the addition of constraints imposed by the mechanical equilibrium conditions. Besides correcting the data,i.e.providing more reliable through-thickness residual stress trends, the proposed procedure also provides an elastically compatible and plausible estimate of the residual stress inside the component, well beyond the measured region. The application of the model is illustrated for a set of Al-alloy components shot-peened at different Almen intensities. Results are compared with those given by `blind hole drilling', which is an independent and partly destructive method.


Sign in / Sign up

Export Citation Format

Share Document