Model signal-to-noise comparison for CCD arrays versus film

1997 ◽  
Author(s):  
Rodney Shaw
2000 ◽  
Vol 6 (S2) ◽  
pp. 732-733
Author(s):  
S.A. Hiller ◽  
B. Kabius ◽  
W. Probst ◽  
H. Tröster ◽  
M. Trendelenburg ◽  
...  

Excellent linearity and high sensitivity have made SSCs the ideal image detector for almost every TEM application. Their ability to make high quality digital images available within fraction of seconds for further evaluation and processing in a PC, have made them a non-dispensable accessory for any modern TEM. However, despite their excellent characteristics, SSCs provide a restricted number of individual image points in respect to a negative, what is considered to be the main disadvantage of this detector. To compensate for this, CCDs with 2048x2048 pixel are available since some time. SSCs using these 2kx2k CCD arrays not only provide 4 times the pixel number but also offer a lot more options people have waiting for: e. g. highly resolved low-dose or ESI images with significantly improved signal to noise ratio, or higher resolved images for diffraction analysis and holographic reconstruction.


Author(s):  
Robert M. Glaeser

It is well known that a large flux of electrons must pass through a specimen in order to obtain a high resolution image while a smaller particle flux is satisfactory for a low resolution image. The minimum particle flux that is required depends upon the contrast in the image and the signal-to-noise (S/N) ratio at which the data are considered acceptable. For a given S/N associated with statistical fluxtuations, the relationship between contrast and “counting statistics” is s131_eqn1, where C = contrast; r2 is the area of a picture element corresponding to the resolution, r; N is the number of electrons incident per unit area of the specimen; f is the fraction of electrons that contribute to formation of the image, relative to the total number of electrons incident upon the object.


Author(s):  
David A. Grano ◽  
Kenneth H. Downing

The retrieval of high-resolution information from images of biological crystals depends, in part, on the use of the correct photographic emulsion. We have been investigating the information transfer properties of twelve emulsions with a view toward 1) characterizing the emulsions by a few, measurable quantities, and 2) identifying the “best” emulsion of those we have studied for use in any given experimental situation. Because our interests lie in the examination of crystalline specimens, we've chosen to evaluate an emulsion's signal-to-noise ratio (SNR) as a function of spatial frequency and use this as our critereon for determining the best emulsion.The signal-to-noise ratio in frequency space depends on several factors. First, the signal depends on the speed of the emulsion and its modulation transfer function (MTF). By procedures outlined in, MTF's have been found for all the emulsions tested and can be fit by an analytic expression 1/(1+(S/S0)2). Figure 1 shows the experimental data and fitted curve for an emulsion with a better than average MTF. A single parameter, the spatial frequency at which the transfer falls to 50% (S0), characterizes this curve.


Author(s):  
W. Kunath ◽  
K. Weiss ◽  
E. Zeitler

Bright-field images taken with axial illumination show spurious high contrast patterns which obscure details smaller than 15 ° Hollow-cone illumination (HCI), however, reduces this disturbing granulation by statistical superposition and thus improves the signal-to-noise ratio. In this presentation we report on experiments aimed at selecting the proper amount of tilt and defocus for improvement of the signal-to-noise ratio by means of direct observation of the electron images on a TV monitor.Hollow-cone illumination is implemented in our microscope (single field condenser objective, Cs = .5 mm) by an electronic system which rotates the tilted beam about the optic axis. At low rates of revolution (one turn per second or so) a circular motion of the usual granulation in the image of a carbon support film can be observed on the TV monitor. The size of the granular structures and the radius of their orbits depend on both the conical tilt and defocus.


Author(s):  
David L. Wetzel ◽  
John A. Reffner ◽  
Gwyn P. Williams

Synchrotron radiation is 100 to 1000 times brighter than a thermal source such as a globar. It is not accompanied with thermal noise and it is highly directional and nondivergent. For these reasons, it is well suited for ultra-spatially resolved FT-IR microspectroscopy. In efforts to attain good spatial resolution in FT-IR microspectroscopy with a thermal source, a considerable fraction of the infrared beam focused onto the specimen is lost when projected remote apertures are used to achieve a small spot size. This is the case because of divergence in the beam from that source. Also the brightness is limited and it is necessary to compromise on the signal-to-noise or to expect a long acquisition time from coadding many scans. A synchrotron powered FT-IR Microspectrometer does not suffer from this effect. Since most of the unaperatured beam’s energy makes it through even a 12 × 12 μm aperture, that is a starting place for aperture dimension reduction.


Author(s):  
M. Unser ◽  
B.L. Trus ◽  
A.C. Steven

Since the resolution-limiting factor in electron microscopy of biological macromolecules is not instrumental, but is rather the preservation of structure, operational definitions of resolution have to be based on the mutual consistency of a set of like images. The traditional measure of resolution for crystalline specimens in terms of the extent of periodic reflections in their diffraction patterns is such a criterion. With the advent of correlation averaging techniques for lattice rectification and the analysis of non-crystalline specimens, a more general - and desirably, closely compatible - resolution criterion is needed. Two measures of resolution for correlation-averaged images have been described, namely the differential phase residual (DPR) and the Fourier ring correlation (FRC). However, the values that they give for resolution often differ substantially. Furthermore, neither method relates in a straightforward way to the long-standing resolution criterion for crystalline specimens.


Author(s):  
W. Baumeister ◽  
R. Rachel ◽  
R. Guckenberger ◽  
R. Hegerl

IntroductionCorrelation averaging (CAV) is meanwhile an established technique in image processing of two-dimensional crystals /1,2/. The basic idea is to detect the real positions of unit cells in a crystalline array by means of correlation functions and to average them by real space superposition of the aligned motifs. The signal-to-noise ratio improves in proportion to the number of motifs included in the average. Unlike filtering in the Fourier domain, CAV corrects for lateral displacements of the unit cells; thus it avoids the loss of resolution entailed by these distortions in the conventional approach. Here we report on some variants of the method, aimed at retrieving a maximum of information from images with very low signal-to-noise ratios (low dose microscopy of unstained or lightly stained specimens) while keeping the procedure economical.


Author(s):  
James F. Hainfeld ◽  
Daniel Safer ◽  
Joseph S. Wall ◽  
Martha Simon ◽  
Beth Lin ◽  
...  

Uranyl and tungstate compounds have found favor as negative stains because of their high scattering power relative to biological molecules. However, other properties, such as specimen preservation, resistance to alterations or crystallization in the electron beam, and signal to noise (S/N) ratio, are also important. It may be that lower density materials may have advantages in these areas. A new negative stain, methylamine vanadate, CH3 NH2.VO3 ("NanoVan"), offers a near physiological pH of 8, similar to phosphotungstate (pH 7) with much smoother background. It is also very stable in the electron beam with minimal granulation at a dose of l04 el / nm2 . The resolution obtainable with vanadate appears to be comparable to uranyl at low dose, but superior at higher dose where uranyl forms coarse grains (see Fig. 1). Problems with uranyl such as unwanted positive staining and need for pH below 4 can be avoided. The lower contrast permits use of thicker stain embedment for better preservation and less flattening without excessive beam attenuation.


Author(s):  
G.A. Bertero ◽  
R. Sinclair

Pt/Co multilayers displaying perpendicular (out-of-plane) magnetic anisotropy and 100% perpendicular remanent magnetization are strong candidates as magnetic media for the next generation of magneto-optic recording devices. The magnetic coercivity, Hc, and uniaxial anisotropy energy, Ku, are two important materials parameters, among others, in the quest to achieving higher recording densities with acceptable signal to noise ratios (SNR). The relationship between Ku and Hc in these films is not a simple one since features such as grain boundaries, for example, can have a strong influence on Hc but affect Ku only in a secondary manner. In this regard grain boundary separation provides a way to minimize the grain-to-grain magnetic coupling which is known to result in larger coercivities and improved SNR as has been discussed extensively in the literature for conventional longitudinal recording media.We present here results from the deposition of two Pt/Co/Tb multilayers (A and B) which show significant differences in their coercive fields.


Author(s):  
D. C. Joy ◽  
R. D. Bunn

The information available from an SEM image is limited both by the inherent signal to noise ratio that characterizes the image and as a result of the transformations that it may undergo as it is passed through the amplifying circuits of the instrument. In applications such as Critical Dimension Metrology it is necessary to be able to quantify these limitations in order to be able to assess the likely precision of any measurement made with the microscope.The information capacity of an SEM signal, defined as the minimum number of bits needed to encode the output signal, depends on the signal to noise ratio of the image - which in turn depends on the probe size and source brightness and acquisition time per pixel - and on the efficiency of the specimen in producing the signal that is being observed. A detailed analysis of the secondary electron case shows that the information capacity C (bits/pixel) of the SEM signal channel could be written as :