scholarly journals Preexercise Cycling Protocol Alters Pacing Behavior in Competitive Time Trials

2020 ◽  
Vol 15 (9) ◽  
pp. 1303-1308
Author(s):  
Marco J. Konings ◽  
Florentina J. Hettinga

Purpose: The behavior of an opponent has been shown to alter pacing and performance. To advance our understanding of the impact of perceptual stimuli such as an opponent on pacing and performance, this study examined the effect of a preexercise cycling protocol on exercise regulation with and without an opponent. Methods: Twelve trained cyclists performed 4 experimental, self-paced 4-km time-trial conditions on an advanced cycle ergometer in a randomized, counterbalanced order. Participants started the time trial in rested state (RS) or performed a 10-min cycling protocol at 67% peak power output (CP) before the time trial. During the time trials, participants had to ride alone (NO) or against a virtual opponent (OP). The experimental conditions were (1) RS-NO, (2) RS-OP, (3) CP-NO, and (4) CP-OP. Repeated-measures analyses of variance (P < .05) were used to examine differences in pacing and performance in terms of power output. Results: A faster pace was adopted in the first kilometer during RS-OP (318 [72] W) compared with RS-NO (291 [81] W; P = .03), leading to an improved finishing time during RS-OP compared with RS-NO (P = .046). No differences in either pacing or performance were found between CP-NO and CP-OP. Conclusions: The evoked response by the opponent to adopt a faster initial pace in the 4-km time trial disappeared when cyclists had to perform a preceding cycling protocol. The outcomes of this study highlight that perceived exertion alters the responsiveness to perceptual stimuli of cyclists during competition.

2009 ◽  
Vol 4 (4) ◽  
pp. 517-523 ◽  
Author(s):  
Carl D. Paton

Purpose:Aerobic economy is an important factor that affects the performance of competitive cyclists. It has been suggested that placing the foot more anteriorly on the bicycle pedals may improve economy over the traditional foot position by improving pedaling efficiency. The current study examines the effects of changing the anterior-posterior pedal foot position on the physiology and performance of well-trained cyclists.Methods:In a crossover study, 10 competitive cyclists completed two maximal incremental and two submaximal tests in either their preferred (control) or a forward (arch) foot position. Maximum oxygen consumption and peak power output were determined from the incremental tests for both foot positions. On two further occasions, cyclists also completed a two-part 60-min submaximal test that required them to maintain a constant power output (equivalent to 60% of their incremental peak power) for 30 min, during which respiratory and blood lactate samples were taken at predetermined intervals. Thereafter, subjects completed a 30-min self-paced maximal effort time trial.Results:Relative to the control, the mean changes (±90% confidence limits) in the arch condition were as follows: maximum oxygen consumption, -0.5% (±2.0%); incremental peak power output, -0.8% (±1.3%); steady-state oxygen consumption at 60%, -2.4% (±1.1%); steady-state heart rate 60%, 0.4% (±1.7%); lactate concentration 60%, 8.7% (±14.4%); and mean time trial power, -1.5% (±2.9%).Conclusions:We conclude that there was no substantial physiological or performance advantage in this group using an arch-cleat shoe position in comparison with a cyclist’s normal preferred condition.


2018 ◽  
Vol 13 (3) ◽  
pp. 283-289 ◽  
Author(s):  
Marco J. Konings ◽  
Jordan Parkinson ◽  
Inge Zijdewind ◽  
Florentina J. Hettinga

Purpose: Performing against a virtual opponent has been shown to invite a change in pacing and improve time-trial (TT) performance. This study explored how this performance improvement is established by assessing changes in pacing, neuromuscular function, and perceived exertion. Methods: After a peak-power-output test and a familiarization TT, 12 trained cyclists completed two 4-km TTs in randomized order on a Velotron cycle ergometer. TT conditions were riding alone (NO) and riding against a virtual opponent (OP). Knee-extensor performance was quantified before and directly after the TT using maximal voluntary contraction force (MVC), voluntary activation (VA), and potentiated doublet-twitch force (PT). Differences between the experimental conditions were examined using repeated-measures ANOVAs. Linear-regression analyses were conducted to associate changes in pacing to changes in MVC, VA, and PT. Results: OP was completed faster than NO (mean power output OP 289.6 ± 56.1 vs NO 272.2 ± 61.6 W; P = .020), mainly due to a faster initial pace. This was accompanied by a greater decline in MVC (MVC pre vs post −17.5% ± 12.4% vs −11.4% ± 10.9%, P = .032) and PT (PT pre vs post −23.1% ± 14.0% vs −16.2% ±11.4%, P = .041) after OP than after NO. No difference between conditions was found for VA (VA pre vs post −4.9% ± 6.7% vs −3.4% ± 5.0%, P = .274). Rating of perceived exertion did not differ between OP and NO. Conclusion: The improved performance when racing against a virtual opponent was associated with a greater decline in voluntary and evoked muscle force than riding alone, without a change in perceived exertion, highlighting the importance of human–environment interactions in addition to one’s internal state for pacing regulation and performance.


Circulation ◽  
2021 ◽  
Vol 143 (Suppl_1) ◽  
Author(s):  
Colin Carriker ◽  
Phillip Armentrout ◽  
Sarah Levine ◽  
James Smoliga

Introduction: Previous studies have examined dietary nitrate supplementation and its effects on dry static apnea, and peak power. Dietary nitrate supplementation has been found to increase maximal apnea and peak power output. The purpose of this study was to determine the effects of beetroot juice on dry static apnea and Wingate performance. Hypothesis: Dietary nitrate will improve maximal breath hold time and peak power output. Dietary nitrate will improve tolerance to CO2, thereby improving maximal breath hold time and anaerobic capacity. Methods: In a randomized, double-blind, counterbalanced study, five healthy males (20.4±0.89 years) visited the lab on 3 separate occasions each separated by one week. Visit 1 served as a Wingate and breath hold familiarization visit. Prior to visits 2 and 3 participants were instructed to drink a beverage either a placebo (negligible nitrate content, PL) or dietary nitrate rich beverage (12.4 mmol nitrate, NIT) during the 4 days leading up to their next visit. Visits 2 and 3 consisted of two submaximal breath holds (80% of maximal determined during visit 1), with 2 minutes of rest between and three minutes of rest preceding the final breath hold for maximal duration. Finally, participants completed a standardized 10-minute warmup on the cycle ergometer before completing a 30-second maximal effort Wingate test. Results: A linear mixed effects model was used to determine whether treatment (NIT vs. PL) was associated with differences in VCO2 or PetCO2. Time (0, 10, 20, 30 min post-breath hold) and Treatment both served as repeated measures. Models were developed using multiple repeated measures covariance matrix structures, and the model with the lowest AIC was chosen as the final model. The interaction between time and treatment was included in the original models, and was removed if it was not statistically significant. Time was a statistically significant factor for VCO2 and PetCO2 (p < 0.001). Treatment, and the Time x Treatment interaction was not significant for either variable. No differences between NIT and PL were observed during the Wingate test for either time to peak power (5.02±2.45 and 6.2±2.43 sec, respectively) or maximal power (9.73±1.01 and 9.72±1.03 watts/kg, respectively) and fatigue index (49.42±14.98 and 47.30±6.99 watts/sec, respectively). Conclusion: Preliminary data indicates that in a general population four days of dietary nitrate supplementation may not improve breath hold time, tolerance to carbon dioxide in the lungs, or Wingate performance.


2020 ◽  
Vol 17 (8) ◽  
pp. 835-839
Author(s):  
Carley O’Neill ◽  
Shilpa Dogra

Background: Low- and moderate-intensity exercise training has been shown to be effective for reducing general anxiety and anxiety sensitivity among adults with asthma. Exercise frequency and intensity have been shown to play an integral role in reducing anxiety sensitivity; however, less is known about the impact of high-intensity interval training (HIIT) on anxiety in adults with asthma. Methods: A 6-week HIIT intervention was conducted with adults with asthma. Participants completed HIIT (10% peak power output for 1 min, 90% peak power output for 1 min, repeated 10 times) 3 times per week on a cycle ergometer. Preintervention and postintervention assessments included the Anxiety Sensitivity Index-3 and the Body Sensations Questionnaire. Results: Total Anxiety Sensitivity Index-3 (PRE: 17.9 [11.8]; POST 12.4 [13], P = .002, Cohen d = 0.4, n = 20) and Body Sensations Questionnaire (PRE: 2.4 [1.0]; POST: 2.0 [0.8], P = .007, Cohen d = 0.3) improved from preintervention to postintervention. Conclusion: A 6-week HIIT intervention leads to improved anxiety among adults with asthma. Future research should determine the impact of HIIT among adults with asthma with clinical anxiety.


2000 ◽  
Vol 89 (6) ◽  
pp. 2220-2226 ◽  
Author(s):  
Mark A. Febbraio ◽  
Alison Chiu ◽  
Damien J. Angus ◽  
Melissa J. Arkinstall ◽  
John A. Hawley

We investigated the effect of carbohydrate (CHO) ingestion before and during exercise and in combination on glucose kinetics, metabolism and performance in seven trained men, who cycled for 120 min (SS) at ∼63% of peak power output, followed by a 7 kJ/kg body wt time trial (TT). On four separate occasions, subjects received either a placebo beverage before and during SS (PP); placebo 30 min before and 2 g/kg body wt of CHO in a 6.4% CHO solution throughout SS (PC); 2 g/kg body wt of CHO in a 25.7% CHO beverage 30 min before and placebo throughout SS (CP); or 2 g/kg body wt of CHO in a 25.7% CHO beverage 30 min before and 2 g/kg of CHO in a 6.4% CHO solution throughout SS (CC). Ingestion of CC and CP markedly (>8 mM) increased plasma glucose concentration ([glucose]) compared with PP and PC (5 mM). However, plasma [glucose] fell rapidly at the onset of SS so that after 80 min it was similar (6 mM) between all treatments. After this time, plasma [glucose] declined in both PP and CP ( P < 0.05) but was well maintained in both CC and PC. Ingestion of CC and CP increased rates of glucose appearance (Ra) and disappearance (Rd) compared with PP and PC at the onset of, and early during, SS ( P < 0.05). However, late in SS, both glucose Ra and Rd were higher in CC and PC compared with other trials ( P < 0.05). Although calculated rates of glucose oxidation were different when comparing the four trials ( P < 0.05), total CHO oxidation and total fat oxidation were similar. Despite this, TT was improved in CC and PC compared with PP ( P < 0.05). We conclude that 1) preexercise ingestion of CHO improves performance only when CHO ingestion is maintained throughout exercise, and 2) ingestion of CHO during 120 min of cycling improves subsequent TT performance.


Author(s):  
Theresa Schörkmaier ◽  
Yvonne Wahl ◽  
Christian Brinkmann ◽  
Wilhelm Bloch ◽  
Patrick Wahl

AbstractRecent studies have shown that the oxygenated hemoglobin level can be enhanced during rest through the application of nonivamide-nicoboxil cream. However, the effect of nonivamide-nicoboxil cream on oxygenation and endurance performance under hypoxic conditions is unknown. Therefore, the purpose of this study was to investigate the effects of nonivamide-nicoboxil cream on local muscle oxygenation and endurance performance under normoxic and hypoxic conditions. In a cross-over design, 13 athletes (experienced cyclists or triathletes [age: 25.2±3.5 years; VO2max 62.1±7.3 mL·min−1·kg−1]) performed four incremental exercise tests on the cycle ergometer under normoxic or hypoxic conditions, either with nonivamide-nicoboxil or placebo cream. Muscle oxygenation was recorded with near-infrared spectroscopy. Capillary blood samples were taken after each step, and spirometric data were recorded continuously. The application of nonivamide-nicoboxil cream increased muscle oxygenation at rest and during different submaximal workloads as well as during physical exhaustion, irrespective of normoxic or hypoxic conditions. Overall, there were no significant effects of nonivamide-nicoboxil on peak power output, maximal oxygen uptake or lactate concentrations. Muscle oxygenation is significantly higher with the application of nonivamide-nicoboxil cream. However, its application does not increase endurance performance.


2009 ◽  
Vol 19 (4) ◽  
pp. 400-409 ◽  
Author(s):  
Milou Beelen ◽  
Jort Berghuis ◽  
Ben Bonaparte ◽  
Sam B. Ballak ◽  
Asker E. Jeukendrup ◽  
...  

It has been reported previously that mouth rinsing with a carbohydrate-containing solution can improve cycling performance. The purpose of the current study was to investigate the impact of such a carbohydrate mouth rinse on exercise performance during a simulated time trial in a more practical, postprandial setting. Fourteen male endurance-trained athletes were selected to perform 2 exercise tests in the morning after consuming a standardized breakfast. They performed an ~1-hr time trial on a cycle ergometer while rinsing their mouths with either a 6.4% maltodextrin solution (CHO) or water (PLA) after every 12.5% of the set amount of work. Borg’s rating of perceived exertion (RPE) was assessed after every 25% of the set amount of work, and power output and heart rate were recorded continuously throughout the test. Performance time did not differ between treatments and averaged 68.14 ± 1.14 and 67.52 ± 1.00 min in CHO and PLA, respectively (p = .57). In accordance, average power output (265 ± 5 vs. 266 ± 5 W, p = .58), heart rate (169 ± 2 vs. 168 ± 2 beats/min, p = .43), and RPE (16.4 ± 0.3 vs. 16.7 ± 0.3 W, p = .26) did not differ between treatments. Furthermore, after dividing the trial into 8s, no differences in power output, heart rate, or perceived exertion were observed over time between treatments. Carbohydrate mouth rinsing does not improve time-trial performance when exercise is performed in a practical, postprandial setting.


2017 ◽  
Vol 23 (4) ◽  
pp. 231-238 ◽  
Author(s):  
Cayque Brietzke ◽  
Ricardo Yukio Asano ◽  
Felipe De Russi de Lima ◽  
Fabiano Aparecido Pinheiro ◽  
Franco-Alvarenga ◽  
...  

Background: Ergogenic effects of caffeine (CAF) ingestion have been observed in different cycling exercise modes, and have been associated with alterations in ratings of perceived exertion (RPE). However, there has been little investigation of maximal oxygen uptake (VO2MAX) test outcomes. Aim: This study aimed to verify whether CAF may reduce RPE, thereby improving maximal incremental test (MIT) outcomes such as VO2MAX, time to exhaustion and peak power output (WPEAK). Methods: Nine healthy individuals performed three MITs (25 W/min until exhaustion) in a random, counterbalanced fashion after ingestion of CAF, placebo perceived as caffeine (PLA), and no supplementation (baseline control). VO2 was measured throughout the test, while RPE was rated according to overall and leg effort sensations. The power output corresponding to submaximal (RPE = 14 according to the 6–20 Borg scale) and maximal RPE was recorded for both overall (O-RPE14 and O-RPEMAX) and leg RPE (L-RPE14 and L-RPEMAX). Results: VO2MAX did not change significantly between MITs; however, CAF and PLA increased time to exhaustion (↑ ∼18.7% and ∼17.1%, respectively; p < .05) and WPEAK (↑ ∼13.0% and ∼11.8%, respectively; p < .05) when compared with control. When compared with control, CAF ingestion reduced submaximal and maximal overall and leg RPEs, the effect being greater in maximal (likely beneficial in O-RPEMAX and L-RPEMAX) than submaximal RPE (possibly beneficial in O-RPE14 and L-RPE14). Similar results were found when participants ingested PLA. Conclusions: Compared with control, CAF and PLA improved MIT performance outcomes such as time to exhaustion and WPEAK, without altering VO2MAX values. CAF effects were attributed to placebo.


2014 ◽  
Vol 9 (2) ◽  
pp. 309-315 ◽  
Author(s):  
Gregory T. Levin ◽  
Paul B. Laursen ◽  
Chris R. Abbiss

Purpose:To assess the reliability of a 5-min-stage graded exercise test (GXT) and determine the association between physiological attributes and performance over stochastic cycling trials of varying distance.Methods:Twenty-eight well-trained male cyclists performed 2 GXTs and either a 30-km (n = 17) or a 100-km stochastic cycling time trial (n = 9). Stochastic cycling trials included periods of high-intensity efforts for durations of 250 m, 1 km, or 4 km depending on the test being performing.Results:Maximal physiological attributes were found to be extremely reliable (maximal oxygen uptake [VO2max]: coefficient of variation [CV] 3.0%, intraclass correlation coefficient [ICC] .911; peak power output [PPO]: CV 3.0%, ICC .913), but a greater variability was found in ventilatory thresholds and economy. All physiological variables measured during the GXT, except economy at 200 W, were correlated with 30-km cycling performance. Power output during the 250-m and 1-km efforts of the 30-km trial were correlated with VO2max, PPO, and the power output at the second ventilatory threshold (r = .58–.82). PPO was the only physiological attributed measured during the GXT to be correlated with performance during the 100-km cycling trial (r = .64).Conclusions:Many physiological variables from a reliable GXT were associated with performance over shorter (30-km) but not longer (100-km) stochastic cycling trials.


2006 ◽  
Vol 1 (2) ◽  
pp. 122-136 ◽  
Author(s):  
Hans Luttikholt ◽  
Lars R. McNaughton ◽  
Adrian W. Midgley ◽  
David J. Bentley

Context:There is currently no model that predicts peak power output (PPO) thereby allowing comparison between different incremental exercise test (EXT) protocols. In this study we have used the critical power profile to develop a mathematical model for predicting PPO from the results of different EXTs.Purpose:The purpose of this study was to examine the level of agreement between actual PPO values and those predicted from the new model.Methods:Eleven male athletes (age 25 ± 5 years, VO2max 62 ± 8 mL · kg–1 · min–1) completed 3 laboratory tests on a cycle ergometer. Each test comprised an EXT consisting of 1-minute workload increments of 30 W (EXT30/1) and 3-minute (EXT25/3) and 5-minute workload increments (EXT25/5) of 25 W. The PPO determined from each test was used to predict the PPO from the remaining 2 EXTs.Results:The differences between actual and predicted PPO values were statistically insignificant (P > .05). The random error components of the limits of agreement of ≤30 W also indicated acceptable levels of agreement between actual and predicted PPO values.Conclusions:Further data collection is necessary to confirm whether the model is able to predict PPO over a wide range of EXT protocols in athletes of different aerobic and anaerobic capacities.


Sign in / Sign up

Export Citation Format

Share Document