Using Pedometers to Estimate Ambulatory Physical Activity in Vietnam

2011 ◽  
Vol 8 (1) ◽  
pp. 52-61 ◽  
Author(s):  
Au Bich Thuy ◽  
Leigh Blizzard ◽  
Michael Schmidt ◽  
Costan Magnussen ◽  
Emily Hansen ◽  
...  

Background:Pedometer measurement of physical activity (PA) has been shown to be reliable and valid in industrialized populations, but its applicability in economically developing Vietnam remains untested. This study assessed the feasibility, stability and validity of pedometer estimates of PA in Vietnam.Methods:250 adults from a population-based survey were randomly selected to wear Yamax pedometers and record activities for 7 consecutive days. Stability and concurrent validity were assessed using intraclass correlation coefficients (ICC) and Spearman correlation coefficients.Results:Overall, 97.6% of participants provided at least 1 day of usable recordings, and 76.2% wore pedometers for all 7 days. Only 5.2% of the sample participants were involved in work activities not measurable by pedometer. The number of steps increased with hours of wear. There was no significant difference between weekday and weekend in number of steps, and at least 3 days of recordings were required (ICC of the 3 days of recordings: men 0.96, women 0.97). Steps per hour were moderately correlated (men r = .42, women r = .26) with record estimates of total PA.Conclusions:It is feasible to use pedometers to estimate PA in Vietnam. The measure should involve at least 3 days of recording irrespective of day of the week.

Sensors ◽  
2021 ◽  
Vol 21 (9) ◽  
pp. 3065
Author(s):  
Ernest Kwesi Ofori ◽  
Shuaijie Wang ◽  
Tanvi Bhatt

Inertial sensors (IS) enable the kinematic analysis of human motion with fewer logistical limitations than the silver standard optoelectronic motion capture (MOCAP) system. However, there are no data on the validity of IS for perturbation training and during the performance of dance. The aim of this present study was to determine the concurrent validity of IS in the analysis of kinematic data during slip and trip-like perturbations and during the performance of dance. Seven IS and the MOCAP system were simultaneously used to capture the reactive response and dance movements of fifteen healthy young participants (Age: 18–35 years). Bland Altman (BA) plots, root mean square errors (RMSE), Pearson’s correlation coefficients (R), and intraclass correlation coefficients (ICC) were used to compare kinematic variables of interest between the two systems for absolute equivalency and accuracy. Limits of agreements (LOA) of the BA plots ranged from −0.23 to 0.56 and −0.21 to 0.43 for slip and trip stability variables, respectively. The RMSE for slip and trip stabilities were from 0.11 to 0.20 and 0.11 to 0.16, respectively. For the joint mobility in dance, LOA varied from −6.98–18.54, while RMSE ranged from 1.90 to 13.06. Comparison of IS and optoelectronic MOCAP system for reactive balance and body segmental kinematics revealed that R varied from 0.59 to 0.81 and from 0.47 to 0.85 while ICC was from 0.50 to 0.72 and 0.45 to 0.84 respectively for slip–trip perturbations and dance. Results of moderate to high concurrent validity of IS and MOCAP systems. These results were consistent with results from similar studies. This suggests that IS are valid tools to quantitatively analyze reactive balance and mobility kinematics during slip–trip perturbation and the performance of dance at any location outside, including the laboratory, clinical and home settings.


2017 ◽  
Vol 44 (8) ◽  
pp. 1249-1256 ◽  
Author(s):  
Wineke Armbrust ◽  
G.J.F. Joyce Bos ◽  
Jan H.B. Geertzen ◽  
Pieter J.J. Sauer ◽  
Pieter U. Dijkstra ◽  
...  

Objective.(1) To determine convergent validity of an activity diary (AD) and accelerometer (Actical brand/Phillips-Respironics) in measuring physical activity (PA) in children with juvenile idiopathic arthritis (JIA). (2) To determine how many days give reliable results. (3) To analyze effects of correcting accelerometer data for non-wear.Methods.Patients with JIA (8–13 yrs) were recruited from 3 Dutch pediatric rheumatology centers. PA was assessed for 7 days with an AD and accelerometer, and was expressed as mean min/day of rest, light PA (LPA), moderate to vigorous PA (MVPA), and PA level (PAL). To analyze convergent validity, intraclass correlation coefficients (ICC) were calculated and paired sample Student t tests were performed. The required number of days to achieve reliable results was calculated using the Spearman-Brown prophecy formula.Results.Convergent validity between AD and accelerometer was moderate for rest and PAL (ICC 0.41). ICC for LPA and MVPA were < 0.24. AD overestimated PAL and MVPA compared with the accelerometer. Wearing the accelerometer 7–19 days gave reliable PA estimates on group and individual levels. For the AD, 13–36 days were needed. Adjusting accelerometer data for non-wear resulted in a clinically relevant higher mean number of min/day spent in LPA (effect size 1.12), but not in MVPA (effect size 0.44).Conclusion.Convergent validity between AD and accelerometer is moderate to poor. In children with JIA, 1-week assessment with an accelerometer is sufficient to measure PA (all levels) reliably. On an individual level and for clinical use, 3 weeks are required. Additional use of AD enables correction for non-wear of accelerometer data.


2004 ◽  
Vol 84 (10) ◽  
pp. 906-918 ◽  
Author(s):  
Diane M Wrisley ◽  
Gregory F Marchetti ◽  
Diane K Kuharsky ◽  
Susan L Whitney

Background and Purpose. The Functional Gait Assessment (FGA) is a 10-item gait assessment based on the Dynamic Gait Index. The purpose of this study was to evaluate the reliability, internal consistency, and validity of data obtained with the FGA when used with people with vestibular disorders. Subjects. Seven physical therapists from various practice settings, 3 physical therapist students, and 6 patients with vestibular disorders volunteered to participate. Methods. All raters were given 10 minutes to review the instructions, the test items, and the grading criteria for the FGA. The 10 raters concurrently rated the performance of the 6 patients on the FGA. Patients completed the FGA twice, with an hour's rest between sessions. Reliability of total FGA scores was assessed using intraclass correlation coefficients (2,1). Internal consistency of the FGA was assessed using the Cronbach alpha and confirmatory factor analysis. Concurrent validity was assessed using the correlation of the FGA scores with balance and gait measurements. Results. Intraclass correlation coefficients of .86 and .74 were found for interrater and intrarater reliability of the total FGA scores. Internal consistency of the FGA scores was .79. Spearman rank order correlation coefficients of the FGA scores with balance measurements ranged from .11 to .67. Discussion and Conclusion. The FGA demonstrates what we believe is acceptable reliability, internal consistency, and concurrent validity with other balance measures used for patients with vestibular disorders.


2004 ◽  
Vol 21 (2) ◽  
pp. 167-179 ◽  
Author(s):  
Heidi I. Stanish

Walking is a common physical activity reported by individuals with mental retardation (MR). This study examined the accuracy and feasibility of pedometers for monitoring walking in 20 adults with MR. Also, step counts and distance walked were recorded for one week. Pedometer counts were highly consistent with actual step counts during normal and fast paced walking on two ground surfaces. Intraclass correlation coefficients were above .95. A t-test revealed no gender differences in walking activity. A 2 × 2 ANOVA indicated that participants with Down Syndrome (DS) accumulated significantly fewer step counts than those without DS and participants walked more on weekdays than weekends.


2020 ◽  
Vol 43 (4) ◽  
pp. 235-254
Author(s):  
Angela Patricia Bacelis-Rivero ◽  
Anabel Vázquez-Rodríguez ◽  
Claudia E. Carrasco-Legleu ◽  
Lidia G. De León ◽  
Sandra Alicia Reza-López

Physical activity (PA) is a component of total energy expenditure. PA and PA energy expenditure (PAEE) can be estimated by objective techniques (OTs). However, the use of questionnaires is frequent in clinical settings and epidemiological studies. We conducted a search on PubMed, Scopus, and Google Scholar databases to perform a review of studies reporting the reliability and validity of PA questionnaires validated against OTs—doubly labeled water (DLW) or accelerometers—in free-living adults. We selected original articles published between 2009 and 2019 that reported validation studies of PA questionnaires. We identified 53 studies that fulfilled the eligibility criteria. Four PA questionnaires were validated against DLW and the remaining against accelerometers. Three questionnaires were compared with both DLW and accelerometer results. The correlation between questionnaire-estimated PAEE and DLW results ranged from r = .22 to r = .46, while that between questionnaire-estimated total PA (TPA) and accelerometer results ranged from r = .11 to r = .54 The intraclass correlation coefficients were between .56 and .84. Despite having good reliability, most of the questionnaires included in this review have shown limited validity for estimating TPA in adults. OTs should be considered as a first option, when possible. Further research is warranted on techniques to obtain more accurate PA and PAEE estimates.


1998 ◽  
Vol 7 (4) ◽  
pp. 300-306 ◽  
Author(s):  
Gary L. Harrelson ◽  
Deidre Leaver-Dunn ◽  
A. Louise Fincher ◽  
James D. Leeper

The purpose of this study was to examine the inter- and intratester reliability of lower extremity circumference measurements obtained by two testers using the same tape measure and two different tape measures. Twenty-one male high school student-athletes participated in this study. Two testers measured lower extremity circumference at three sites using a standard flexible tape measure and a Lufkin tape measure with a Gulick spring-loaded handle attachment. Measurement sites were medial joint line, 20 cm above medial joint line, and 15 cm below medial joint line. Intraclass correlation coefficients were computed for inter- and intratester comparisons for each measuring device and each measurement site. Results indicated high reliability but a significant difference between the two tape measures. These findings indicate that the reliability of lower extremity circumference measurements is not influenced by tester experience and that the Lufkin tape measure with the Gulick handle attachment is the more accurate of the two tape measures.


2014 ◽  
Vol 114 (1) ◽  
pp. 93-103 ◽  
Author(s):  
Tomas Larson ◽  
Eva Norén Selinus ◽  
Clara Hellner Gumpert ◽  
Thomas Nilsson ◽  
Nóra Kerekes ◽  
...  

The Autism-Tics, AD/HD, and other Comorbidities (A–TAC) inventory is used in epidemiological research to assess neurodevelopmental problems and coexisting conditions. Although the A–TAC has been applied in various populations, data on retest reliability are limited. The objective of the present study was to present additional reliability data. The A–TAC was administered by lay assessors and was completed on two occasions by parents of 400 individual twins, with an average interval of 70 days between test sessions. Intra- and inter-rater reliability were analysed with intraclass correlations and Cohen's κ. A–TAC showed excellent test-retest intraclass correlations for both autism spectrum disorder and attention deficit hyperactivity disorder (each at .84). Most modules in the A–TAC had intra- and inter-rater reliability intraclass correlation coefficients of ≥ .60. Cohen's κ indicated acceptable reliability. The current study provides statistical evidence that the A–TAC yields good test-retest reliability in a population-based cohort of children.


2020 ◽  
Vol 44 (6) ◽  
pp. 502-509
Author(s):  
Min-Yong Lee ◽  
Kwan-Sik Sung ◽  
Hyungsuk Ham ◽  
You Gyoung Yi ◽  
Hyung-Ik Shin

Objective To investigate the reliability of knee extensor strength measurements using a supine hand-held dynamometer (HHD) anchoring frame in patients with limited physical activity. Although an HHD is suitable for bedside use, its inter-rater reliability is low because measurements can be influenced by tester strength.Methods Maximal knee extensor isometric strength was measured using an HHD anchored to the supine frame. Three trials of three maximal contractions were assessed by two raters.Results A total of 33 inpatients who were non-ambulatory due to acute illness participated in the study. The intraclass correlation coefficients were 0.974 (inter-rater) and 0.959 (intra-rater). The minimal detectable changes in intra- and inter-observer measurements were 29.46 N (24.10%) and 36.73 N (29.26%), respectively. The limits of agreement ranged from -19.79% to 24.81% for intra-rater agreement and from -21.45% to 37.07% for inter-rater agreement.Conclusion The portable dynamometer anchoring system can measure the isometric strength of the knee extensor reliably in the supine position, and could be used for measurements in patients who have difficulty visiting the laboratory and maintaining a seated posture.


2014 ◽  
Vol 28 (1) ◽  
pp. 16-20 ◽  
Author(s):  
Dominic A. Giuliano ◽  
Marion McGregor

Objective This study combined a learning outcomes-based checklist and salient characteristics derived from wisdom-of-crowds theory to test whether differing groups of judges (diversity maximized versus expertise maximized) would be able to appropriately assess videotaped, manikin-based simulation scenarios. Methods Two groups of 3 judges scored 9 videos of interns managing a simulated cardiac event. The first group had a diverse range of knowledge of simulation procedures, while the second group was more homogeneous in their knowledge and had greater simulation expertise. All judges viewed 3 types of videos (predebriefing, postdebriefing, and 6 month follow-up) in a blinded fashion and provided their scores independently. Intraclass correlation coefficients (ICCs) were used to assess the reliability of judges as related to group membership. Scores from each group of judges were averaged to determine the impact of group on scores. Results Results revealed strong ICCs for both groups of judges (diverse, 0.89; expert, 0.97), with the diverse group of judges having a much wider 95% confidence interval for the ICC. Analysis of variance of the average checklist scores indicated no significant difference between the 2 groups of judges for any of the types of videotapes assessed (F = 0.72, p = .4094). There was, however, a statistically significant difference between the types of videos (F = 14.39, p = .0004), with higher scores at the postdebrief and 6-month follow-up time periods. Conclusions Results obtained in this study provide optimism for assessment procedures in simulation using learning outcomes-based checklists and a small panel of judges.


2019 ◽  
Vol 16 (10) ◽  
pp. 818-829
Author(s):  
Christina M. Patch ◽  
Caterina G. Roman ◽  
Terry L. Conway ◽  
Ralph B. Taylor ◽  
Kavita A. Gavand ◽  
...  

Background: A common hypothesis is that crime is a major barrier to physical activity, but research does not consistently support this assumption. This article advances research on crime-related safety and physical activity by developing a multilevel conceptual framework and reliable measures applicable across age groups. Methods: Criminologists and physical activity researchers collaborated to develop a conceptual framework. Survey development involved qualitative data collection and resulted in 155 items and 26 scales. Intraclass correlation coefficients (ICCs) were computed to assess test–retest reliability in a subsample of participants (N = 176). Analyses were conducted separately by age groups. Results: Test–retest reliability for most scales (63 of 104 ICCs across 4 age groups) was “excellent” or “good” (ICC ≥ .60) and only 18 ICCs were “poor” (ICC < .40). Reliability varied by age group. Adolescents (aged 12–17 y) had ICCs above the .40 threshold for 21 of 26 scales (81%). Young adults (aged 18–39 y) and middle-aged adults (aged 40–65 y) had ICCs above .40 for 24 (92%) and 23 (88%) scales, respectively. Older adults (aged 66 y and older) had ICCs above .40 for 18 of 26 scales (69%). Conclusions: The conceptual framework and reliable measures can be used to clarify the inconclusive relationships between crime-related safety and physical activity.


Sign in / Sign up

Export Citation Format

Share Document