scholarly journals Knee Extensor Strength Measurement in Patients With Limited Physical Activity Using a Supine Dynamometer Anchoring Frame

2020 ◽  
Vol 44 (6) ◽  
pp. 502-509
Author(s):  
Min-Yong Lee ◽  
Kwan-Sik Sung ◽  
Hyungsuk Ham ◽  
You Gyoung Yi ◽  
Hyung-Ik Shin

Objective To investigate the reliability of knee extensor strength measurements using a supine hand-held dynamometer (HHD) anchoring frame in patients with limited physical activity. Although an HHD is suitable for bedside use, its inter-rater reliability is low because measurements can be influenced by tester strength.Methods Maximal knee extensor isometric strength was measured using an HHD anchored to the supine frame. Three trials of three maximal contractions were assessed by two raters.Results A total of 33 inpatients who were non-ambulatory due to acute illness participated in the study. The intraclass correlation coefficients were 0.974 (inter-rater) and 0.959 (intra-rater). The minimal detectable changes in intra- and inter-observer measurements were 29.46 N (24.10%) and 36.73 N (29.26%), respectively. The limits of agreement ranged from -19.79% to 24.81% for intra-rater agreement and from -21.45% to 37.07% for inter-rater agreement.Conclusion The portable dynamometer anchoring system can measure the isometric strength of the knee extensor reliably in the supine position, and could be used for measurements in patients who have difficulty visiting the laboratory and maintaining a seated posture.

2011 ◽  
Vol 8 (1) ◽  
pp. 52-61 ◽  
Author(s):  
Au Bich Thuy ◽  
Leigh Blizzard ◽  
Michael Schmidt ◽  
Costan Magnussen ◽  
Emily Hansen ◽  
...  

Background:Pedometer measurement of physical activity (PA) has been shown to be reliable and valid in industrialized populations, but its applicability in economically developing Vietnam remains untested. This study assessed the feasibility, stability and validity of pedometer estimates of PA in Vietnam.Methods:250 adults from a population-based survey were randomly selected to wear Yamax pedometers and record activities for 7 consecutive days. Stability and concurrent validity were assessed using intraclass correlation coefficients (ICC) and Spearman correlation coefficients.Results:Overall, 97.6% of participants provided at least 1 day of usable recordings, and 76.2% wore pedometers for all 7 days. Only 5.2% of the sample participants were involved in work activities not measurable by pedometer. The number of steps increased with hours of wear. There was no significant difference between weekday and weekend in number of steps, and at least 3 days of recordings were required (ICC of the 3 days of recordings: men 0.96, women 0.97). Steps per hour were moderately correlated (men r = .42, women r = .26) with record estimates of total PA.Conclusions:It is feasible to use pedometers to estimate PA in Vietnam. The measure should involve at least 3 days of recording irrespective of day of the week.


2017 ◽  
Vol 44 (8) ◽  
pp. 1249-1256 ◽  
Author(s):  
Wineke Armbrust ◽  
G.J.F. Joyce Bos ◽  
Jan H.B. Geertzen ◽  
Pieter J.J. Sauer ◽  
Pieter U. Dijkstra ◽  
...  

Objective.(1) To determine convergent validity of an activity diary (AD) and accelerometer (Actical brand/Phillips-Respironics) in measuring physical activity (PA) in children with juvenile idiopathic arthritis (JIA). (2) To determine how many days give reliable results. (3) To analyze effects of correcting accelerometer data for non-wear.Methods.Patients with JIA (8–13 yrs) were recruited from 3 Dutch pediatric rheumatology centers. PA was assessed for 7 days with an AD and accelerometer, and was expressed as mean min/day of rest, light PA (LPA), moderate to vigorous PA (MVPA), and PA level (PAL). To analyze convergent validity, intraclass correlation coefficients (ICC) were calculated and paired sample Student t tests were performed. The required number of days to achieve reliable results was calculated using the Spearman-Brown prophecy formula.Results.Convergent validity between AD and accelerometer was moderate for rest and PAL (ICC 0.41). ICC for LPA and MVPA were < 0.24. AD overestimated PAL and MVPA compared with the accelerometer. Wearing the accelerometer 7–19 days gave reliable PA estimates on group and individual levels. For the AD, 13–36 days were needed. Adjusting accelerometer data for non-wear resulted in a clinically relevant higher mean number of min/day spent in LPA (effect size 1.12), but not in MVPA (effect size 0.44).Conclusion.Convergent validity between AD and accelerometer is moderate to poor. In children with JIA, 1-week assessment with an accelerometer is sufficient to measure PA (all levels) reliably. On an individual level and for clinical use, 3 weeks are required. Additional use of AD enables correction for non-wear of accelerometer data.


2004 ◽  
Vol 21 (2) ◽  
pp. 167-179 ◽  
Author(s):  
Heidi I. Stanish

Walking is a common physical activity reported by individuals with mental retardation (MR). This study examined the accuracy and feasibility of pedometers for monitoring walking in 20 adults with MR. Also, step counts and distance walked were recorded for one week. Pedometer counts were highly consistent with actual step counts during normal and fast paced walking on two ground surfaces. Intraclass correlation coefficients were above .95. A t-test revealed no gender differences in walking activity. A 2 × 2 ANOVA indicated that participants with Down Syndrome (DS) accumulated significantly fewer step counts than those without DS and participants walked more on weekdays than weekends.


2020 ◽  
Vol 43 (4) ◽  
pp. 235-254
Author(s):  
Angela Patricia Bacelis-Rivero ◽  
Anabel Vázquez-Rodríguez ◽  
Claudia E. Carrasco-Legleu ◽  
Lidia G. De León ◽  
Sandra Alicia Reza-López

Physical activity (PA) is a component of total energy expenditure. PA and PA energy expenditure (PAEE) can be estimated by objective techniques (OTs). However, the use of questionnaires is frequent in clinical settings and epidemiological studies. We conducted a search on PubMed, Scopus, and Google Scholar databases to perform a review of studies reporting the reliability and validity of PA questionnaires validated against OTs—doubly labeled water (DLW) or accelerometers—in free-living adults. We selected original articles published between 2009 and 2019 that reported validation studies of PA questionnaires. We identified 53 studies that fulfilled the eligibility criteria. Four PA questionnaires were validated against DLW and the remaining against accelerometers. Three questionnaires were compared with both DLW and accelerometer results. The correlation between questionnaire-estimated PAEE and DLW results ranged from r = .22 to r = .46, while that between questionnaire-estimated total PA (TPA) and accelerometer results ranged from r = .11 to r = .54 The intraclass correlation coefficients were between .56 and .84. Despite having good reliability, most of the questionnaires included in this review have shown limited validity for estimating TPA in adults. OTs should be considered as a first option, when possible. Further research is warranted on techniques to obtain more accurate PA and PAEE estimates.


2019 ◽  
Vol 16 (10) ◽  
pp. 818-829
Author(s):  
Christina M. Patch ◽  
Caterina G. Roman ◽  
Terry L. Conway ◽  
Ralph B. Taylor ◽  
Kavita A. Gavand ◽  
...  

Background: A common hypothesis is that crime is a major barrier to physical activity, but research does not consistently support this assumption. This article advances research on crime-related safety and physical activity by developing a multilevel conceptual framework and reliable measures applicable across age groups. Methods: Criminologists and physical activity researchers collaborated to develop a conceptual framework. Survey development involved qualitative data collection and resulted in 155 items and 26 scales. Intraclass correlation coefficients (ICCs) were computed to assess test–retest reliability in a subsample of participants (N = 176). Analyses were conducted separately by age groups. Results: Test–retest reliability for most scales (63 of 104 ICCs across 4 age groups) was “excellent” or “good” (ICC ≥ .60) and only 18 ICCs were “poor” (ICC < .40). Reliability varied by age group. Adolescents (aged 12–17 y) had ICCs above the .40 threshold for 21 of 26 scales (81%). Young adults (aged 18–39 y) and middle-aged adults (aged 40–65 y) had ICCs above .40 for 24 (92%) and 23 (88%) scales, respectively. Older adults (aged 66 y and older) had ICCs above .40 for 18 of 26 scales (69%). Conclusions: The conceptual framework and reliable measures can be used to clarify the inconclusive relationships between crime-related safety and physical activity.


2010 ◽  
Vol 45 (4) ◽  
pp. 349-356 ◽  
Author(s):  
Roger O. Kollock ◽  
James A. Onate ◽  
Bonnie Van Lunen

Abstract Context: Insufficient lower extremity strength may be a risk factor for lower extremity injuries such as noncontact anterior cruciate ligament tears. Therefore, clinicians need reliable instruments to assess strength deficiencies. Objective: To assess the intrarater, interrater, intrasession, and intersession reliability of a portable fixed dynamometer in measuring the strength of the hip and knee musculature. Design: Crossover study. Setting: Sports medicine research laboratory. Patients or Other Participants: Three raters (A, B, C) participated in this 2-phase study. Raters A and B tested 11 healthy college graduate students (2 men, 9 women) in phase 1. Raters A and C tested 26 healthy college undergraduate students (7 men, 19 women) in phase 2. Main Outcome Measure(s): The dependent variables for the study were hip adductor, hip abductor, hip flexor, hip extensor, hip internal rotator, hip external rotator, knee flexor, and knee extensor peak force. Results: The phase 1 intrasession intraclass correlation coefficients for sessions 1, 2, and 3 ranged from 0.88 to 0.99 (SEM  =  0.08–3.02 N), 0.85 to 0.99 (SEM  =  0.26–3.88 N), and 0.92 to 0.96 (SEM  =  0.52–2.76 N), respectively. Intraclass correlation coefficients ranged from 0.57 to 0.95 (SEM  =  1.72–13.15 N) for phase 1 intersession values, 0.70 to 0.94 (SEM  =  1.42–9.20 N) for phase 2 intrarater reliability values, and 0.69 to 0.88 (SEM  =  1.20–8.50 N) for phase 2 interrater values. Conclusions: The portable fixed dynamometer showed good to high intrasession and intersession reliability values for hip and knee strength. Intrarater and interrater reliability were fair to high, except for hip internal rotation, which showed poor reliability.


2015 ◽  
Vol 23 (2) ◽  
pp. 271-286 ◽  
Author(s):  
Jiying Ling ◽  
Kristi M. King

Background and Purpose: Evidence of compliance, reliability, and reactivity of using pedometers in children remains inconsistent. This study aimed to examine these aspects of unsealed pedometers. Methods: There were 133 children who wore pedometers for 7 days. A subsample of 50 children completed surveys measuring self-efficacy, enjoyment, parental influence, and environment on Day 1 and 8. Investigator presence and incentives were used to increase compliance. Results: About 87% of children returned pedometers, with 62% wearing pedometers for 4 days or longer. The intraclass correlation coefficients ranged from .70 to .87, with ICC for 4-day pedometer steps exceeding .80. Wearing pedometers did not change pedometer steps nor alter children’s perceptions of self-efficacy, enjoyment, parental influence, and environment significantly. Conclusions: Children were compliant wearing pedometers, and there was no reactivity from wearing them.


2006 ◽  
Vol 3 (4) ◽  
pp. 423-438 ◽  
Author(s):  
Leslie A. Pruitt ◽  
Abby C. King ◽  
Eva Obarzanek ◽  
Michael Miller ◽  
Mary O’Toole ◽  
...  

Background:Physical activity recall (PAR) reliability was estimated in a three-site sample of African American and white adults. The sample was sedentary at baseline and more varied in physical activity 24 months later. Intraclass correlation coefficients (ICCs) were used to estimate the number of PAR assessments necessary to obtain a reliability of 0.70 at both timepoints.Methods:The PAR was administered ≤ 30 d apart at baseline (n = 547) and 24 months (n = 648). Energy expenditure ICC was calculated by race, gender, and age.Results:Baseline reliability was low for all groups with 4–16 PARs estimated to attain reliable data. ICCs at 24 months were similar (ICC = 0.54–0.55) for race and age group, with 2–3 PARs estimated to reach acceptable reliability. At 24 months, women were more reliable reporters than men.Conclusion:Low sample variability in activity reduced reliability, highlighting the importance of evaluating diverse groups. Despite evaluating a sample with greater physical activity variability, an estimated 2–3 PARs were necessary to obtain acceptable reliability.


1991 ◽  
Vol 34 (5) ◽  
pp. 989-999 ◽  
Author(s):  
Stephanie Shaw ◽  
Truman E. Coggins

This study examines whether observers reliably categorize selected speech production behaviors in hearing-impaired children. A group of experienced speech-language pathologists was trained to score the elicited imitations of 5 profoundly and 5 severely hearing-impaired subjects using the Phonetic Level Evaluation (Ling, 1976). Interrater reliability was calculated using intraclass correlation coefficients. Overall, the magnitude of the coefficients was found to be considerably below what would be accepted in published behavioral research. Failure to obtain acceptably high levels of reliability suggests that the Phonetic Level Evaluation may not yet be an accurate and objective speech assessment measure for hearing-impaired children.


Author(s):  
Marcos A Soriano ◽  
G Gregory Haff ◽  
Paul Comfort ◽  
Francisco J Amaro-Gahete ◽  
Antonio Torres-González ◽  
...  

The aims of this study were to (I) determine the differences and relationship between the overhead press and split jerk performance in athletes involved in weightlifting training, and (II) explore the magnitude of these differences in one-repetition maximum (1RM) performances between sexes. Sixty-one men (age: 30.4 ± 6.7 years; height: 1.8 ± 0.5 m; body mass 82.5 ± 8.5 kg; weightlifting training experience: 3.7 ± 3.5 yrs) and 21 women (age: 29.5 ± 5.2 yrs; height: 1.7 ± 0.5 m; body mass: 62.6 ± 5.7 kg; weightlifting training experience: 3.0 ± 1.5 yrs) participated. The 1RM performance of the overhead press and split jerk were assessed for all participants, with the overhead press assessed on two occasions to determine between-session reliability. The intraclass correlation coefficients (ICC) and 95% confidence intervals showed a high reliability for the overhead press ICC = 0.98 (0.97 – 0.99). A very strong correlation and significant differences were found between the overhead press and split jerk 1RM performances for all participants (r = 0.90 [0.93 – 0.85], 60.2 ± 18.3 kg, 95.7 ± 29.3 kg, p ≤ 0.001). Men demonstrated stronger correlations between the overhead press and split jerk 1RM performances (r = 0.83 [0.73-0.90], p ≤ 0.001) compared with women (r = 0.56 [0.17-0.80], p = 0.008). These results provide evidence that 1RM performance of the overhead press and split jerk performance are highly related, highlighting the importance of upper-limb strength in the split jerk maximum performance.


Sign in / Sign up

Export Citation Format

Share Document