Nonlethal estimation of proximate composition in fish

2005 ◽  
Vol 62 (2) ◽  
pp. 269-275 ◽  
Author(s):  
M Keith Cox ◽  
Kyle J Hartman

The need to precisely measure growth is a common denominator in many fisheries studies, but growth measures other than total masses or lengths are nearly nonexistent because more precise measurements such as body composition analysis are often too difficult and time consuming. Here, we present a means of estimating body composition in fish quickly, and after validation, without the need to sacrifice the animal. Models built with brook trout (Salvelinus fontinalis) were linear with strong validation group relationships (R2 > 0.96) for composition parameters including water, protein, fat, fat-free, and dry masses. Subject responses to bioelectrical impedance analysis were minimal, with only slight bruising (p < 0.001) with no effect on swimming, color, bleeding, or feeding. The model was also tested on the water and dry masses of 10 warmwater fish species and found to have strong correlations (R2 > 0.86), suggesting that more general relationships may exist. Nonlethal estimation of body composition using bioelectrical impedance analysis will permit increased precision in bioenergetics energy flow and compositional studies as well as permit study of community energetics and condition on spatial and temporal scales not previously possible.

2018 ◽  
Author(s):  
Carla M Prado ◽  
Camila LP Oliveira ◽  
M Cristina Gonzalez ◽  
Steven B Heymsfield

Body composition assessment is an important tool in both clinical and research settings able to characterize the nutritional status of individuals in various physiologic and pathologic conditions. Health care professionals can use the information acquired by body composition analysis for the prevention and treatment of diseases, ultimately improving health status. Here we describe commonly used techniques to assess body composition in healthy individuals, including dual-energy x-ray absorptiometry, bioelectrical impedance analysis, air displacement plethysmography, and ultrasonography. Understanding the key underlying concept(s) of each assessment method, as well as its advantages and limitations, facilitates selection of the method of choice and the method of the compartment of interest. This review contains 5 figures, 3 tables and 52 references Key words: air displacement plethysmography, bioelectrical impedance analysis, body composition, disease, dual-energy x-ray absorptiometry, health, muscle mass, nutritional status, obesity, sarcopenia, ultrasound fat mass


Author(s):  
Jasmina Pluncević Gligoroska ◽  
Sanja Mančevska ◽  
Niki Matveeva ◽  
Elizabeta Sivevska ◽  
Žarko Kostovski

The aim of the paper was to asses changes in body composition using bioelectrical impedance analysis (BIA) methodology in members of national karate team after teen week preparatory training period. The investigation was carried out on 11 male karate contestants, aged 18 to 28 years mean age (21.82± 3.58). The body composition was analyzed with In Body 720. The BIA outcomes were divided in 3 group of variables: body fluid and body composition variables, obesity diagnose variables and segmental analysis variables. All BIA variables were insignificantly higher at second measuring (p>005). Only Body mass index (BMI=24.1 vs 24.55); mineral (4.69 kg vs 4.77 kg) and osseous (3.85 kg vs 3.92 kg), were significantly higher (p≤0.05) after preparatory period. Body fat mass (BFM=10.34 kg vs 10.75 kg, p=0.329) and body fat percent (BF%= 12.73 vs13.22%) insignificantly increased after preparatory period. The skeletal mass has changed from 40.03kg to 40.55kg (p=0.276). Body composition analysis, changes in weight, BMI and body fluids are essential for weight categories dependent sports such as karate. Positive changes in body components and in body fluids suggest that the training process during the preparatory period did not show negative effects on body components and the hydration of the karate athletes.


2014 ◽  
pp. 1-5
Author(s):  
T. KAMO ◽  
H. ISHII ◽  
D. TAKAHASHI ◽  
K. IWAGAYA ◽  
T. ISHIDA ◽  
...  

Background: Body composition is an important component of health related fitness. Near-infrared spectroscopy (NIRS) is a non-invasive, simple and rapid method of assessing body fat percentage. However, it is unknown whether NIRS can accurately estimate FFM in community-dwelling frail elderly. Objectives: This study aimed to compare NIRS with bioelectrical impedance analysis (BIA) in FFM measurement. Design: Cross-sectional study. Setting: Shizuoka, Japan. Participants: The study population comprised 53 community-dwelling frail elderly (15 men, 38 women; mean age 84.8±6.4 years; body mass index 19.7±3.5 kg/m2). Measurement: FFM and percentage fat mass (%FM) were estimated using a NIRS device at two sites (biceps and calf) and compared to body composition measured by BIA. Simple linear regression and Bland–Altman analyses were used to determine agreement between the methods. Results: FFM determined by BIA highly correlated with that determined by NIRS at both the biceps and calf (r=0.92 for both; p<0.001). The correlation coefficients for %FM estimated by NIRS were slightly lower (r=0.70 for biceps; r=0.66 for calf). In NIRS assessments, systematic biases were found for %FM but not for FFM. Conclusion: NIRS has significant potential for body composition analysis. Further comparative and longitudinal studies need to be conducted using an agreed reference analysis method to find a simple and more suitable method that can be applied among the community-dwelling frail elderly.


2020 ◽  
Vol 2020 ◽  
pp. 1-12
Author(s):  
Michelle Bai ◽  
Daniella Susic ◽  
Anthony J. O’Sullivan ◽  
Amanda Henry

Introduction. Bioelectrical impedance analysis (BIA) is a rapid and noninvasive method of body composition analysis; however, reproducibility between BIA instruments in pregnancy is uncertain. Adverse maternal body composition has been linked to pregnancy complications including gestational diabetes mellitus (GDM). This study aimed to evaluate the reproducibility of three BIA instruments in pregnancy and analyse the relationship between the body composition and the GDM risk. Methods. A prospective cohort (n = 117) of women with singleton pregnancies participating in the Microbiome Understanding in Maternity Study (MUMS) at St. George Hospital, Sydney, Australia. Anthropometric measurements and BIA body composition were measured at ≤13 weeks (T1), 20–24 weeks (T2), and 32–36 weeks (T3) of gestation. Body fat percentage (BFP), total body water (TBW), and impedance were estimated by three BIA instruments: Bodystat 1500, RJL Quantum III, and Tanita BC-587. GDM status was recorded after 75 g oral glucose tolerance test was performed at 28 weeks or earlier. Agreement between BIA instruments was assessed using Bland–Altman analysis. Logistic regression modelling explored associations of BFP with GDM. Results. Method comparison reproducibility between Bodystat and RJL was stronger than between Bodystat and Tanita for both BFP and TBW% at all three time points. RJL overestimated BFP on average by 3.3% (p<0.001), with limits of agreement within ±5% for all trimesters. Average BFP was not significantly different between Tanita and Bodystat although limits of agreement exceeded ±5%. GDM diagnosis was independently associated with increased BFP in T1 (adjusted OR 1.117 per 1% increase; 95% CI 1.020–1.224; p=0.017) and in T2 (adjusted OR 1.113 per 1% increase; 95% CI 1.010–1.226; p=0.031) and with Asian ethnicity in all models (OR 7.4–8.1). Conclusion. Reproducibility amongst instruments was moderate; therefore, interchangeability between instruments, particularly for research purposes, cannot be assumed. In this cohort, GDM risk was modestly associated with increasing BFP and strongly associated with Asian ethnicity.


2021 ◽  
Vol 6 (4) ◽  
pp. S52
Author(s):  
D. BASNAYAKE ◽  
A. Nayanamali ◽  
H. Amarathunga ◽  
N. Erandika ◽  
J. Pathiraja ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document