Validation of seismic design parameters for wood-frame shearwall systems

2002 ◽  
Vol 29 (3) ◽  
pp. 484-498 ◽  
Author(s):  
Ario Ceccotti ◽  
Erol Karacabeyli

A methodology for assessment of seismic design parameters for a wood-frame shearwall system is developed, consisting of a test program of shearwalls and the application of nonlinear time history analyses to a four-storey wood-frame building that was designed to resist the seismic requirements for Vancouver, British Columbia. Analyses employed 22 selected earthquake accelerograms that were scaled upwards until an ultimate peak ground acceleration (Au) was reached where the shearwall reached a "near-collapse" state. The 22 values of Au were found to be greater than the "design" peak ground acceleration, indicating the adequacy of the current design procedures for the particular shearwalls investigated. The influence of gypsum wallboard on the behaviour of the shearwalls was also evaluated, and a new force modification factor "R" for walls composed of a mixture of wood-based and gypsum panels was proposed. The effect of flexibility of floor diaphragms was considered separately for a symmetric building and was found to have 5-30% reduction on the Au values obtained for the rigid diaphragm case.Key words: seismic design, earthquake loads, timber structures, wood shearwalls.

2021 ◽  
Author(s):  
Mohammad Zaman ◽  
Mohammad Reza Ghayamghamian

Abstract In most buildings’ seismic design codes design basis peak ground acceleration (PGADBE) is provided by employing a uniform-hazard approach. However, a new trend in updating seismic codes is to adopt a risk-informed method to estimate the PGADBE so-called risk-adjusted design basis peak ground acceleration (PGARDBE). An attempt is made here to examine the adequacy of the PGARDBE to fulfill the assumptions made in seismic codes for converting the maximum considered earthquake’s (MCE) intensity to PGADBE. To this end, the performance of regular intermediate steel moment frames (IMF) is assessed in terms of collapse margin (CMR) and residual drift ratios in the event of MCE and design basis earthquake (DBE), respectively. The PGARDBEs are computed for Karaj County, Iran. A set of 96 index archetypes of regular IMF are designed considering four design parameters, which include the number of stories (2, 3, 6, 9, 12, and 15), span lengths (4 and 8 meters), occupancies (residential and commercial), and seismic demands (0.15, 0.25, 0.35 and 0.45g). The PGADBE prescribed by Standard No. 2800 for Karaj neither meets the assumed acceptance criteria nor stands on the safe side. Meanwhile, PGARDBE fulfills the acceptance criteria but does not necessarily satisfy the implicit assumption made in codes that the code-conforming buildings have at least a CMR of 1.5 if the MCE occurs. This emphasizes that the PGARDBE should not be used without examining the CMR fulfillment. The results recommend that a lower limit need to be set on PGARDBEs, which is found to be 0.35g for Karaj. Outcomes also reveal that the code-conforming buildings designed with the proposed PGARDBE can fulfill both repairability and life safety performances at the DBE and MCE, respectively. These buildings also have a high chance to be even considered as repairable ones at the seismic demand of MCE. Furthermore, regardless of the employed method for estimating PGADBE, various relationships between design parameters with different performance indicators such as CMR, residual drift ratio, ductility demand, imposed drift ratio, and building’s normalized weight are presented. These relationships can be used to evaluate the buildings’ safety factor against collapse and repairability, justification of using IMF in regions with high seismicity, level of structural and nonstructural damage as well as the economic consequence of changes in PGADBE. The presented relationships provide a multi-criteria decision-making tool to decide on the optimum PGADBE leading to an affordable alternative and tolerable damage.


2018 ◽  
Vol 20 (1) ◽  
pp. 35
Author(s):  
Pamuda Pudjisuryadi ◽  
Benjamin Lumantarna ◽  
Ryan Setiawan ◽  
Christian Handoko

The recent seismic code SNI 1726-2012 is significantly different compared to the older code SNI 1726-2002. The seismic hazard map was significantly changed and the level of maximum considered earthquake was significantly increased. Therefore, buildings designed according to outdated code may not resist the higher demand required by newer code. In this study, seismic performance of Hotel X in Kupang, Indonesia which was designed based on SNI-1726-2002 is investigated. The structure was analyzed using Nonlinear Time History Analysis. The seismic load used was a spectrum consistent ground acceleration generated from El-Centro 18 May 1940 North-South component in accordance to SNI 1726-2012. The results show that Hotel X can resist maximum considered earthquake required by SNI 1726-2012. The maximum drift ratio is 0.81% which is lower than the limit set by FEMA 356-2000 (2%). Plastic hinge damage level is also lower than the allowance in ACMC 2001.


2021 ◽  
Vol 11 (22) ◽  
pp. 10745
Author(s):  
Sajib Sarker ◽  
Dookie Kim ◽  
Md Samdani Azad ◽  
Chana Sinsabvarodom ◽  
Seongoh Guk

This research identifies the significant optimal intensity measures (IM) for seismic performance assessments of the fixed offshore jacket platforms. A four-legged jacket platform for the oil and gas operation is deployed to investigate the seismic performance. The jacket platform is applied with nonlinearly modeled using finite element (FE) software OpenSees. A total of 80 ground motions and 21 different IMs are incorporated for numerical analyses. Nonlinear time-history analyses are performed to obtain the jacket structure’s engineering demand parameters (EDP): peak acceleration and displacement at the top of the structure. Four important statistical parameters: practicality, efficiency, proficiency, and coefficient of determination, are then calculated to find the significant IMs for seismic performance of the jacket structure. The results show that acceleration-related IMs: effective design acceleration (EDA), A95 parameter, and peak ground acceleration (PGA) are optimal IMs, and the acceleration-related IMs have good agreements with the acceleration-related EDP.


2021 ◽  
Vol 2021 ◽  
pp. 1-7
Author(s):  
Hongxian Chu ◽  
Yongcai Feng ◽  
Huijie Shi ◽  
Liancheng Hao ◽  
Yiqi Gao ◽  
...  

The Newmark seismic time-history analysis method can take into account the effects of natural seismic peak ground acceleration (PGA), duration, and seismic frequency; seismic wave can be input into the method for simulation. This study calculates the dynamic response of the typical seabed slope of Caofeidian in the event of a similar Tangshan earthquake, and the displacement value can be used to quantitatively reflect the influence of the earthquake on the slope of the site. The allowable displacement value of the top of buildings or submarine slope can be used as a marker of security and stability analysis, which can further provide important reference for similar slope stability evaluation and offshore engineering construction.


2009 ◽  
Vol 25 (3) ◽  
pp. 583-605 ◽  
Author(s):  
Wei Chiang Pang ◽  
David V. Rosowsky

This paper presents a direct displacement design (DDD) procedure that can be used for seismic design of multistory wood-framed structures. The proposed procedure is applicable to any pure shear deforming system. The design procedure is a promising design tool for performance-based seismic design since it allows consideration of multiple performance objectives (e.g., damage limitation, safety requirements) without requiring the engineer to perform a complex finite element or nonlinear time-history analysis of the complete structure. A simple procedure based on normalized modal analysis is used to convert the code-specified acceleration response spectrum into a set of interstory drift spectra. These spectra can be used to determine the minimum stiffness required for each floor based on the drift limit requirements. Specific shear walls can then be directly selected from a database of backbone curves. The procedure is illustrated on the design of two three-story ATC-63 archetype buildings, and the results are validated using nonlinear time-history analysis.


2019 ◽  
Vol 10 (1) ◽  
pp. 30-42
Author(s):  
Abu Bakar Nabilah ◽  
Chan Ghee Koh ◽  
Nor Azizi Safiee ◽  
Nik Norsyahariati Nik Daud

Kuala Lumpur, Malaysia, is considered to be safe against an earthquake threat. However, tremors felt by occupants due to long distance earthquakes from Sumatra has raised concern on building safety in this region. Consequently, Malaysia will adopt the Eurocode 8 for seismic design. The suitability of this code must be studied especially on the threat from far field earthquakes. Thus, site specific hazard assessment has been conducted on seven flexible soil sites in Kuala Lumpur, based on modified time history. The peak ground acceleration (PGA) falls in the category of very low seismicity, however, the amplifications are much higher than recommended by Eurocode 8. The period limits for maximum accelerations are also much higher compared to the value in the code, especially for flexible soils. Adoption of Eurocode 8 for seismic design in this region should be studied to include the effects of high period motions in flexible soils, especially on the amplification factors and its corner periods.


2014 ◽  
Vol 30 (4) ◽  
pp. 1683-1709 ◽  
Author(s):  
Edgar Tapia-Hernández ◽  
Arturo Tena-Colunga

In order to help improve the seismic design of regular steel buildings structured with ductile moment-resisting concentrically braced frames (MRCBFs) using the general design methodology of Mexico's Federal District Code (MFDC-04), suitable design parameters were first assessed using the results of pushover analyses of 13 regular MRCBFs. In order to insure collapse mechanisms consistent with the assumptions implicit in a code-based design (strong-column/weak-beam/weaker-brace), it is proposed to relate the minimum strength ratio for the resisting columns of the moment frames and the bracing system. Improved equations are proposed for a more realistic assessment of ductility and overstrength factors. In a second stage, the effectiveness of the improved methodology was assessed with the design of six regular steel buildings with MRCBFs. Buildings were evaluated by performing both pushover and nonlinear time-history analyses under ten selected artificial ground motions related to the corresponding design spectrum.


1995 ◽  
Vol 22 (2) ◽  
pp. 361-377 ◽  
Author(s):  
Denis Mitchell ◽  
Ronald H. DeVall ◽  
Murat Saatcioglu ◽  
Robert Simpson ◽  
René Tinawi ◽  
...  

Observations on damage to concrete structures, due to the 1994 Northridge earthquake, are reported from a Canadian code perspective. Most of the damaged structures were older, nonductile, structures that do not conform to current design and detailing requirements. Concern is expressed about the seismic hazard of older Canadian structures having similar deficiencies. A significant number of parking structures suffered extensive damage and a number of precast concrete parking structures collapsed. Deficiencies in these structures include lack of proper diaphragm connections, a mix of gravity load columns with ductile framing, inappropriate number and distribution of shear walls, torsional effects caused by ramps, and the creation of short columns due to geometric features. This earthquake also demonstrated the deficiencies in connections of pre-1973 tilt-up structures. Key words: seismic design, earthquake, Northridge, structures, codes, concrete, precast concrete.


2012 ◽  
Vol 28 (1) ◽  
pp. 77-103 ◽  
Author(s):  
Sudhir K. Jain ◽  
A. D. Roshan ◽  
Siddharth Yadav ◽  
Sonam Srivastava ◽  
Prabir C. Basu

In the 1960s several hundred structural response recorders (SRR) were installed all over India. An SRR is a simple instrument consisting of six seismoscopes that provide “maximum response” during an earthquake, without providing the time history. In the past earthquakes, these SRRs have provided several hundred records but they have not been effectively utilized for hazard studies because the measurements from these instruments are considered crude. This paper compares the data obtained from SRRs with that from more modern strong-motion accelerographs (SMAs) for four earthquakes in India. It is shown through statistical analysis that the response obtained from the SRRs is comparable to that from the SMAs. A method has been presented for estimating peak ground acceleration (PGA) from SRR data. Thus, it is shown that SRRs can provide a substantial amount of PGA data for attenuation studies. Many countries may find SRRs useful because of the low costs associated with their manufacture and maintenance.


2011 ◽  
Vol 255-260 ◽  
pp. 2330-2334 ◽  
Author(s):  
Yu Zhang ◽  
Quan Wang Li ◽  
Jian Sheng Fan

The earthquake may attack the structural building from any angle, but in current seismic design codes, this type of uncertainty is seldom accounted. The uncertainty associated with the direction of earthquake excitation was considered in this paper, and its effect on structural responses was investigated. For this purpose, a simple 3-dimensional model with symmetric plan was established, which had fundamental periods ranged from 0.1s to 5.0s, and was subjected to a set of 30 ground motion pairs for which both linear and nonlinear time history analyses were performed. Analyzing results showed that, on average, the elastic roof acceleration is 32% underestimated, and the inelastic roof displacement is 18% underestimated if the variation of earthquake excitation direction is not consider. Recognizing this, a modification factor for the seismic demand was proposed thorough a statistical analysis, which guarantees a probability of 95% design safety


Sign in / Sign up

Export Citation Format

Share Document