Capacitive Deionization Systems for Water Desalination Applications: Role of the Electrosorption Resistance and Non-Electrostatic Binding in the Porous Electrodes

Author(s):  
Yasamin Salamat ◽  
Carlos A. Rios Perez ◽  
Carlos Hidrovo

Due to the increasing demand for clean and potable water stemming from population growth and exacerbated by the scarcity of fresh water resources, more attention has been drawn to different and innovative methods for water desalination. Capacitive deionization (CDI) is a relatively new, low maintenance, and energy efficient technique for desalinating brackish water. In this technique, an electrical field is employed to adsorb ions into a high-porous media. After the saturation of the porous electrodes, their adsorption capacity can be restored through a regeneration process. Various parameters affect the overall performance of CDI. The flow rate at which water is purified in CDI plays an essential role in its ultimate performance. Many studies have shown that desalination percentage decreases as flow rate increases in CDI, since the advection of ions in the flow becomes more dominant than their diffusion toward the electrodes. However, herein, based on a physical model previously developed, we conjecture that for a given amount of time and volume of water, multiple desalination cycles in a high flow rate regime will outperform desalinating in a single cycle at a low flow rate. Moreover, splitting a CDI unit into two sub-units, with the same total length, will lead to higher desalination. Based on these premises, we introduce a new approach aimed at enhancing the overall performance of CDI. An array of CDI cells are sequentially connected to each other with intermediate solutions placed in between them. These intermediate solutions act as buffers to homogenize the outlet concentration of the preceding cell and maintain a constant inlet concentration for the following cell. Desalination tests were conducted to compare the performance of the proposed system, consisting of two CDI units and one intermediate solution buffer, with a two-cascaded-CDI unit system with no intermediate solution. Desalination tests were performed in a high flow rate regime with a low salinity initial solution of NaCl in water. In the buffered arrangement, the concentration of the solution buffer was set at the minimum average outlet concentration of the first CDI test. Experimental data demonstrated the improved performance of the buffered system over the non-buffered system, in terms of desalination percentage and energy consumption. Increasing the number of CDI units and solution buffers in a buffered system, the new proposed method will lead to lower amount of energy consumed per unit volume of the desalinated water.


Materials ◽  
2020 ◽  
Vol 13 (22) ◽  
pp. 5185
Author(s):  
Gbenro Folaranmi ◽  
Mikhael Bechelany ◽  
Philippe Sistat ◽  
Marc Cretin ◽  
Francois Zaviska

Capacitive deionization is an emerging brackish water desalination technology whose principle lies in the utilization of porous electrodes (activated carbon materials) to temporarily store ions. Improving the properties of carbon material used as electrodes have been the focus of recent research, as this is beneficial for overall efficiency of this technology. Herein, we have synthesized a composite of activated carbon/graphene oxide electrodes by using a simple blending process in order to improve the hydrophilic property of activated carbon. Graphene oxide (GO) of different weight ratios was blended with commercial Activated carbon (AC) and out of all the composites, AC/GO-15 (15 wt.% of GO) exhibited the best electrochemical and salt adsorption performance in all operating conditions. The as prepared AC and AC/GO-x (x = 5, 10, 15 and 20 wt.% of GO) were characterized by cyclic voltammetry and their physical properties were also studied. The salt adsorption capacity (SAC) of AC/GO-15 at an operating window of 1.0 V is 5.70 mg/g with an average salt adsorption rate (ASAR) of 0.34 mg/g/min at a 400 mg/L salt initial concentration and has a capacitance of 75 F/g in comparison to AC with 3.74 mg/g of SAC, ASAR of 0.23 mg/g/min and a capacitance of 56 F/g at the same condition. This approach could pave a new way to produce a highly hydrophilic carbon based electrode material in CDI.


Nanomaterials ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 1090
Author(s):  
Gbenro Folaranmi ◽  
Mikhael Bechelany ◽  
Philippe Sistat ◽  
Marc Cretin ◽  
Francois Zaviska

Capacitive deionization is a second-generation water desalination technology in which porous electrodes (activated carbon materials) are used to temporarily store ions. In this technology, porous carbon used as electrodes have inherent limitations, such as low electrical conductivity, low capacitance, etc., and, as such, optimization of electrode materials by rational design to obtain hybrid electrodes is key towards improvement in desalination performance. In this work, different compositions of mixture of reduced graphene oxide (RGO) and activated carbon (from 5 to 20 wt% RGO) have been prepared and tested as electrodes for brackish water desalination. The physico-chemical and electrochemical properties of the activated carbon (AC), reduced graphene oxide (RGO), and as-prepared electrodes (AC/RGO-x) were characterized by low-temperature nitrogen adsorption measurement, scanning electron microscope (SEM), X-ray diffraction (XRD), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), Fourier transform infra-red (FT-IR), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). Among all the composite electrodes, AC/RGO-5 (RGO at 5 wt%) possessed the highest specific capacitance (74 F g−1) and the highest maximum salt adsorption capacity (mSAC) of 8.10 mg g−1 at an operating voltage ∆E = 1.4 V. This shows that this simple approach could offer a potential way of fabricating electrodes of accentuated carbon network of an improved electronic conductivity that’s much coveted in CDI technology.


2016 ◽  
Vol 868 ◽  
pp. 43-49 ◽  
Author(s):  
Hai Bo Li ◽  
Sen Liang ◽  
Mang Mang Gao ◽  
Chang Yeoul Kim

Capacitive deionization (CDI) is a water desalination technique in which salt ions are removed from brackish water by flowing through a spacer channel with porous electrodes on each side. Upon applying a small voltage difference between the two electrodes, cations move to and are accumulated in electrostatic double layers inside the negatively charged cathode and the anions are removed by the positively charged anode. Therefore, one of the advanced merits of CDI is the low driven energy by compared to other desalination technologies. Inspired this, we have performed the calculation on energy consumption of activated carbon based CDI in different operation conditions. The results show that the energy consumptions are significantly related to cell voltage as well as solution concentration. Furthermore, the round trip efficiency as a vital indication in terms of energy consumption have been introduced and discussed as well.


2016 ◽  
Vol 139 (3) ◽  
Author(s):  
Yasamin Salamat ◽  
Carlos A. Rios Perez ◽  
Carlos Hidrovo

Due to the increasing demand for clean and potable water stemming from population growth and exacerbated by the scarcity of fresh water resources, more attention has been drawn to innovative methods for water desalination. Capacitive deionization (CDI) is a low maintenance and energy efficient technique for desalinating brackish water, which employs an electrical field to adsorb ions into a high-porous media. After the saturation of the porous electrodes, their adsorption capacity can be restored through a regeneration process. Herein, based on a physical model previously developed, we conjecture that for a given amount of time and volume of water, multiple desalination cycles in a high flow rate regime will outperform desalinating in a single cycle at a low flow rate. Moreover, splitting a CDI unit into two subunits, with the same total length, will lead to higher desalination. Based on these premises, we introduce a new approach aimed at enhancing the overall performance of CDI. An array of CDI cells are sequentially connected to each other with intermediate solutions placed in between them. Desalination tests were conducted to compare the performance of the proposed system, consisting of two CDI units and one intermediate solution buffer, with a two-cascaded-CDI unit system with no intermediate solution. Experimental data demonstrated the improved performance of the buffered system over the nonbuffered system, in terms of desalination percentage and energy consumption. The new proposed method can lead to lower amount of energy consumed per unit volume of the desalinated water.


2021 ◽  
Vol 223 ◽  
pp. 34-53
Author(s):  
Khadijeh Dehghan ◽  
Seyed Ahmad Mirbagheri ◽  
Mahdi Alam

Fibers ◽  
2018 ◽  
Vol 7 (1) ◽  
pp. 1 ◽  
Author(s):  
Marek Gryta

Only nonwetted porous membranes can be used in membrane distillation. The possibility of application in this process the capillary polypropylene membranes manufactured by thermally-induced phase separation was studied. The performance of a few types of membranes available commercially was presented. The resistance of the membranes to wetting was tested in the continuous process of water desalination. These studies were carried out for 1000 h without module cleaning. The presence of scaling layer on the membranes surface was confirmed by Scanning Electron Microscope observations. Both the permeate flux and distillate conductivity were almost not varied after the studied period of time, what indicates that the used membranes maintained their nonwettability, and the negative influence of scaling was limited. The role of surface porosity on the pore wetting and influence of membrane wettability on the quality of the distillate obtained were discussed.


Energies ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 7641
Author(s):  
Sadam-Hussain Soomro ◽  
Yusufu Abeid Chande Jande ◽  
Salman Memon ◽  
Woo-Seung Kim ◽  
Young-Deuk Kim

A hybrid capacitive deionization and humidification-dehumidification (CDI–HDH) desalination system is theoretically investigated for the desalination of brackish water. The CDI system works with two basic operations: adsorption and regeneration. During adsorption, water is desalted, and during the regeneration process the ions from electrodes are detached and flow out as wastewater, which is higher in salt concentration. This wastewater still contains water but cannot be treated again via the CDI unit because CDI cannot treat higher-salinity waters. The discarding of wastewater from CDI is not a good option, since every drop of water is precious. Therefore, CDI wastewater is treated using waste heat in a process that is less sensitive to high salt concentrations, such as humidification-dehumidification (HDH) desalination. Therefore, in this study, CDI wastewater was treated using the HDH system. Using the combined system (CDI–HDH), this study theoretically investigated brackish water of various salt concentrations and flow rates at the CDI inlet. A maximum distillate of 1079 L/day was achieved from the combined system and the highest recovery rate achieved was 24.90% from the HDH unit. Additionally, two renewable energy sources with novel ideas are recommended to power the CDI–HDH system.


Sign in / Sign up

Export Citation Format

Share Document