scholarly journals Modelling and Quasilinear Control of Compressor Surge and Rotating Stall Vibrations

2010 ◽  
Vol 2010 ◽  
pp. 1-21 ◽  
Author(s):  
Ranjan Vepa

An unsteady nonlinear and extended version of the Moore-Greitzer model is developed to facilitate the synthesis of a quasilinear stall vibration controller. The controller is synthesised in two steps. The first step defines the equilibrium point and ensures that the desired equilibrium point is stable. In the second step, the margin of stability at the equilibrium point is tuned or increased by an appropriate feedback of change in the mass flow rate about the steady mass flow rate at the compressor exit. The relatively simple and systematic non-linear modelling and linear controller synthesis approach adopted in this paper clearly highlights the main features on the controller that is capable of inhibiting compressor surge and rotating stall vibrations. Moreover, the method can be adopted for any axial compressor provided its steady-state compressor and throttle maps are known.

Author(s):  
Byeung Jun Lim ◽  
Tae Choon Park ◽  
Young Seok Kang

In this study, characteristics of stall inception in a single-stage transonic axial compressor with circumferential grooves casing treatment were investigated experimentally. Additionally, the characteristic of increasing irregularity in the pressure inside circumferential grooves as the compressor approaches the stall limit was applied to the stall warning method. Spike-type rotating stall was observed in the single-stage transonic axial compressor with smooth casing. When circumferential grooves were applied, the stall inception was suppressed and the operating point of the compressor moved to lower flow rate than the stall limit. A spike-like disturbance was developed into a rotating stall cell and then the Helmholtz perturbation was overlapped on it at N = 80%. At N = 70 %, the Helmholtz perturbation was observed first and the amplitude of the wave gradually increased as mass flow rate decreased. At N = 60%, spike type stall inceptions were observed intermittently and then developed into continuous rotating stall at lower mass flow rate. Pressure measured at the bottom of circumferential grooves showed that the level of irregularity of pressure increased as flow rate decreased. Based on the characteristic of increasing irregularity of the pressure signals inside the circumferential grooves as stall approaches, an autocorrelation technique was applied to the stall warning. This technique could be used to provide warning against stall and estimate real-time stall margins in compressors with casing treatments.


Author(s):  
Jinlan Gou ◽  
Wei Wang ◽  
Can Ma ◽  
Yong Li ◽  
Yuansheng Lin ◽  
...  

Using supercritical carbon dioxide (SCO2) as the working fluid of a closed Brayton cycle gas turbine is widely recognized nowadays, because of its compact layout and high efficiency for modest turbine inlet temperature. It is an attractive option for geothermal, nuclear and solar energy conversion. Compressor is one of the key components for the supercritical carbon dioxide Brayton cycle. With established or developing small power supercritical carbon dioxide test loop, centrifugal compressor with small mass flow rate is mainly investigated and manufactured in the literature; however, nuclear energy conversion contains more power, and axial compressor is preferred to provide SCO2 compression with larger mass flow rate which is less studied in the literature. The performance of the axial supercritical carbon dioxide compressor is investigated in the current work. An axial supercritical carbon dioxide compressor with mass flow rate of 1000kg/s is designed. The thermodynamic region of the carbon dioxide is slightly above the vapor-liquid critical point with inlet total temperature 310K and total pressure 9MPa. Numerical simulation is then conducted to assess this axial compressor with look-up table adopted to handle the nonlinear variation property of supercritical carbon dioxide near the critical point. The results show that the performance of the design point of the designed axial compressor matches the primary target. Small corner separation occurs near the hub, and the flow motion of the tip leakage fluid is similar with the well-studied air compressor. Violent property variation near the critical point creates troubles for convergence near the stall condition, and the stall mechanism predictions are more difficult for the axial supercritical carbon dioxide compressor.


1976 ◽  
Vol 18 (5) ◽  
pp. 234-238 ◽  
Author(s):  
D. H. McQueen

The one-dimensional equations of surge in centrifugal compressors are solved graphically for the pressure head and mass flow rate as functions of time for a variety of situations, and the results are discussed in terms of the acoustical properties of the external piping. Two important parameters affecting the nature of the surge limit cycle are found to be simply related to the acoustic capacitance and acoustic inductance of the system.


Author(s):  
Dominik Schlüter ◽  
Robert P. Grewe ◽  
Fabian Wartzek ◽  
Alexander Liefke ◽  
Jan Werner ◽  
...  

Abstract Rotating stall is a non-axisymmetric disturbance in axial compressors arising at operating conditions beyond the stability limit of a stage. Although well-known, its driving mechanisms determining the number of stall cells and their rotational speed are still marginally understood. Numerical studies applying full-wheel 3D unsteady RANS calculations require weeks per operating point. This paper quantifies the capability of a more feasible quasi-2D approach to reproduce 3D rotating stall and related sensitivities. The first part of the paper deals with the validation of a numerical baseline the simplified model is compared to in detail. Therefore, 3D computations of a state-of-the-art transonic compressor are conducted. At steady conditions the single-passage RANS CFD matches the experimental results within an error of 1% in total pressure ratio and mass flow rate. At stalled conditions, the full-wheel URANS computation shows the same spiketype disturbance as the experiment. However, the CFD underpredicts the stalling point by approximately 7% in mass flow rate. In deep stall, the computational model correctly forecasts a single-cell rotating stall. The stall cell differs by approximately 21% in rotational speed and 18% in circumferential size from the experimental findings. As the 3D model reflects the compressor behaviour sufficiently accurate, it is considered valid for physical investigations. In the second part of the paper, the validated baseline is reduced in radial direction to a quasi-2D domain only resembling the compressor tip area. Four model variations regarding span-wise location and extent are numerically investigated. As the most promising model matches the 3D flow conditions in the rotor tip region, it correctly yields a single-cell rotating stall. The cell differs by only 7% in circumferential size from the 3D results. Due to the impeded radial migration in the quasi-2D slice, however, the cell exhibits an increased axial extent. It is assumed, that the axial expansion into the adjacent rows causes the difference in cell speed by approximately 24%. Further validation of the reduced model against experimental findings reveals, that it correctly reflects the sensitivity of circumferential cell size to flow coefficient and individual cell speed to compressor shaft speed. As the approach reduced the wall clock time by 92%, it can be used to increase the physical understanding of rotating stall at much lower costs.


Author(s):  
Saad A. Ahmed

Centrifugal compressors or blowers are widely used in many industrial applications. However, the operation of such systems is limited at low-mass flow rates by self-excited flow instabilities which could result in rotating stall or surge of the compressor. These instabilities will limit the flow range in which the compressor or the blower can operate, and will also lower their performance and efficiency. Experimental techniques were used to investigate a model of radial vaneless diffuser at stall and stall-free operating conditions. The speed of the impeller was kept constant, while the mass flow rate was reduced gradually to study the steady and unsteady operating conditions of the compressor. Additional experiments were made to investigate the effects of reducing the exit flow area on the inception of stall. The results indicate that the instability in the diffuser was successfully delayed to a lower flow coefficient when throttle rings were attached to either one or both of the diffuser walls (i.e., to reduce the diffuser exit flow area). The results also showed that an increase of the blockage ratio improves the stability of the system (i.e., the critical mass flow rate could be reduced to 50% of its value without blockage). The results indicate that the throttle rings could be an effective method to control stall in radial diffusers.


2014 ◽  
Vol 30 (3) ◽  
pp. 307-313 ◽  
Author(s):  
R. Taghavi-Zenou ◽  
S. Abbasi ◽  
S. Eslami

ABSTRACTThis paper deals with tip leakage flow structure in subsonic axial compressor rotor blades row under different operating conditions. Analyses are based on flow simulation utilizing computational fluid dynamic technique. Three different circumstances at near stall condition are considered in this respect. Tip leakage flow frequency spectrum was studied through surveying instantaneous static pressure signals imposed on blades surfaces. Results at the highest flow rate, close to the stall condition, showed that the tip vortex flow fluctuates with a frequency close to the blade passing frequency. In addition, pressure signals remained unchanged with time. Moreover, equal pressure fluctuations at different passages guaranteed no peripheral disturbances. Tip leakage flow frequency decreased with reduction of the mass flow rate and its structure was changing with time. Spillage of the tip leakage flow from the blade leading edge occurred without any backflow in the trailing edge region. Consequently, various flow structures were observed within every passage between two adjacent blades. Further decrease in the mass flow rate provided conditions where the spilled flow ahead of the blade leading edge together with trailing edge backflow caused spike stall to occur. This latter phenomenon was accompanied by lower frequencies and higher amplitudes of the pressure signals. Further revolution of the rotor blade row caused the spike stall to eventuate to larger stall cells, which may be led to fully developed rotating stall.


Author(s):  
Chihiro Myoren ◽  
Yasuo Takahashi ◽  
Manabu Yagi ◽  
Takanori Shibata ◽  
Tadaharu Kishibe

An axial compressor was developed for an industrial gas turbine equipped with a water atomization cooling (WAC) system, which is a kind of inlet fogging technique with overspray. The compressor performance was evaluated using a 40MW-class test facility for the advanced humid air turbine system. A prediction method to estimate the effect of WAC was developed for the design of the compressor. The method was based on a streamline curvature (SLC) method implementing a droplet evaporation model. Four test runs with WAC have been conducted since February 2012. The maximum water mass flow rate was 1.2% of the inlet mass flow rate at the 4th test run, while the design value was 2.0%. The results showed that the WAC decreased the inlet and outlet temperatures compared with the DRY (no fogging) case. These decreases changed the matching point of the gas turbine, and increased the mass flow rate and the pressure ratio by 1.8% and 1.1%, respectively. Since prediction results agreed with the results of the test run qualitatively, the compressor performance improvement by WAC was confirmed both experimentally and analytically. The test run with the design water mass flow rate is going to be conducted in the near future.


1988 ◽  
Author(s):  
M. V. Otugen ◽  
R. M. C. So ◽  
B. C. Hwang

Experiments were carried out in a model vaneless diffuser rig to investigate the rotating stall phenomenon and its relation to diffuser geometry. The experimental rig consisted of an actual impeller which was used to deliver the flow to the vaneless diffuser. Mass flow rate through the system could be adjusted by varying the rotational speed of the impeller at a fixed inlet opening or by changing the inlet opening at a fixed impeller speed. The flow exited to room condition. As such, the rig was designed to investigate the fluid mechanics of vaneless diffuser rotating stall only. Attention was focused on the effects of diffuser width and radius on rotating stall. Three diffuser widths and three outlet radii were examined. The width-to-inlet radius ratio varied between 0.09 and 0.142 while the outlet-to-inlet radius ratio varied between 1.5 and 2. Results showed that the critical mass flow rate for the onset of rotating stall decreases with decreasing diffuser width. The critical mass flow rate is affected also by the diffuser radius ratio; larger radius ratios resulted in smaller critical mass flow rates. The ratio of the speed of rotation of the stall cell to impeller speed is found to decrease with increasing number of stall cells. This relative speed also decreases with increasing diffuser radius ratio, but it is largely independent of the diffuser width.


2019 ◽  
Vol 9 (23) ◽  
pp. 5134
Author(s):  
Baojie Liu ◽  
Ying Qiu ◽  
Guangfeng An ◽  
Xianjun Yu

Three-dimensional corner separation is common in axial compressors, which can lead to large flow loss and blockage especially when it evolves into the corner stall (open separation). In this paper, the evolution of the three-dimensional flow structures inside a cantilevered stator of a 1.5 stage low-speed highly loaded axial compressor as the stator hub clearance varies, and its effect on the whole compressor performance are investigated experimentally. Firstly, when the stator hub is sealed, the hub corner stall will occur at small mass flow rate conditions. Then, when a very small stator hub clearance is introduced, the leakage flow tends to strengthen the hub corner separation at large mass flow rate conditions and prompts the occurrence of hub corner stall as the mass flow rate decreases. This is mainly caused by the fact that the leakage flow has relatively low energy due to the viscosity effect in the clearance and large flow loss generation as the clearance flow comes across and mixes with the transverse secondary flow. Finally, when the stator hub clearance increases, the effect of the flow viscosity becomes very weak and could be ignored, so the enhanced leakage flow can suppress the transverse migration of the low energy flow near the hub, and the hub corner separation at large mass flow rate conditions could be weakened and the hub corner stall at small mass flow rate conditions could be removed or delayed. As the stator hub clearance varies, the flow structures inside the stator passage could be summarized into five typical flow structures, and this is closely associated with the performance of the compressor.


Author(s):  
Pascal Nucara ◽  
Abdulnaser Sayma

Current gas turbine technology for power generation is generally optimised for natural gas. Recently the use of Low Calorific Value (LCV) fuels gained interest, particularly, Hydrogen rich syngas resulting from coal and solid waste gasification. When LCV fuels are used the performance and behaviour of the engines could significantly change and modifications may be needed. For instance, due to the relatively low heating value of the syngas, higher fuel mass flow rate is required compared to the natural gas combustion case. This leads to a decrease of demand for air from the compressor, which results in increased back pressure, reduction of stall margin and possible compressor instability. In a previous work an exploration of some compressor geometry modifications to allow for high fuel flexibility was conducted on a single axial compressor rotor. The investigation provided insights into the effect of blade shape modifications, such as stagger, lean and sweep on rotor performance. With the same purpose of identifying trends rather than producing optimum design, in this study the analysis is extended to a multistage axial compressor. Two different investigations have been performed, both having, as objective, the shifting of the original mass flow rate towards a lower value while maintaining high performance. In the first study the effect of IGV and stator vanes stagger variations only was considered while in a second approach the re-design of the original machine included modifies to rotor’s stagger angles. In order to understand the change in each single blade performance when modifying the original geometry, the variation of critical parameters such as blade loading and diffusion factor has been here considered in first analysis.


Sign in / Sign up

Export Citation Format

Share Document