scholarly journals Development and Validation of an Affinity Chromatography-Protein G Method for IgG Quantification

2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Lesly Paradina Fernández ◽  
Loany Calvo ◽  
Lisel Viña

Nimotuzumab, an IgG that recognizes the epidermal growth factor receptor (EGF-R) overexpressed in some tumors, is used in the treatment of advanced head and neck cancer. For the quantification of this protein in cell culture supernatants, protein G-HPLC affinity chromatography is used due to its high affinity and specificity for antibodies of this class. The technique relies on the comparison of the area under the curve of the elution peak of the samples to be evaluated versus to a calibration curve of well-known concentrations and was validated by assessment of its robustness, specificity, repeatability, intermediate precision, accuracy, linearity, limit of detection, limit of quantification, and range. According to results of the study all validation parameters fulfilled the preestablished acceptance criteria and demonstrated the feasibility of the assay for the analysis of samples of cell culture supernatant as well as drug product.

2021 ◽  
Vol 09 ◽  
Author(s):  
Ali Al-Kulabi ◽  
Louis Gooden ◽  
Ijeoma F. Uchegbu

Background: Mycophenolic acid (MPA), an immunosuppressive agent, is used orally to reduce corneal graft rejection. However its oral use is associated with gastrointestinal side effects. Objectives: To prepare MPA nanoparticle eye drops and a validated analytical method. Methods: Aqueous MPA eye drops were prepared by nanoencapsulation of MPA using Nanomerics MET (N-palamitoylN-monomethyl-N,N-dimethyl-N,N,N-trimethyl-6-O-glycolchitosan) at a MET, MPA ratio of 7.5: 1 g g-1 in the presence of glycerol (2.75% w/w). A validated MPA in-formulation drug substance assay was then developed. Results: MET-MPA formulations were prepared as well as a validated assay. Assay validation parameters for the analysis of MPA in the formulation were satisfactory [Plate count = 16458, Capacity Factor = 2.4, Tailing Factor = 1.02, linearity = 0.999 (0.016 – 0.5 mg mL-1 ), limit of detection = 0.056 mg mL-1 , limit of quantification = 0.17 mg mL-1 , accuracy = 98%, intraday and interday relative standard deviation = 0.45% and 4% respectively]. The candidate formulation (z - average mean = 66 ± 0.4 nm, polydispersity index = 0.12 ± 0.012, drug content = 1.14 ± 0.003 mg mL-1 , zeta potential = +8.5 ± 1.4 mV, pH = 7.4 ± 0.02, osmolarity = 309 ± 1.5 mOSm L-1 , viscosity = 1.04 ± 0.001 mPa.s) was then found to be stable for 14 days with respect to drug content at refrigeration, room and accelerated (40C )temperature and. All other formulation parameters were within the ocular comfort range. Conclusions: A validated assay (ICH and US FDA guidelines) for new MPA nanoparticle eye drops has been developed.


2009 ◽  
Vol 92 (3) ◽  
pp. 757-764 ◽  
Author(s):  
Ellen Figueiredo Freire ◽  
Keyller Bastos Borges ◽  
Hélio Tanimoto ◽  
Raquel Tassara Nogueira ◽  
Lucimara Cristiane Toso Bertolini ◽  
...  

Abstract A simple method was optimized and validated for determination of ractopamine hydrochloride (RAC) in raw material and feed additives by HPLC for use in quality control in veterinary industries. The best-optimized conditions were a C8 column (250 4.6 mm id, 5.0 m particle size) at room temperature with acetonitrile100 mM sodium acetate buffer (pH 5.0; 75 + 25, v/v) mobile phase at a flow rate of 1.0 mL/min and UV detection at 275 nm. With these conditions, the retention time of RAC was around 5.2 min, and standard curves were linear in the concentration range of 160240 g/mL (correlation coefficient 0.999). Validation parameters, such as selectivity, linearity, limit of detection (ranged from 1.60 to 2.05 g/mL), limit of quantification (ranged from 4.26 to 6.84 g/mL), precision (relative standard deviation 1.87), accuracy (ranged from 96.97 to 100.54), and robustness, gave results within acceptable ranges. Therefore, the developed method can be successfully applied for the routine quality control analysis of raw material and feed additives.


Author(s):  
Heena Ar Shaikh ◽  
Vandana Jain

Objective: A simple, accurate, precise, robust reverse phase high performance liquid chromatography (RP-HPLC) method was developed for the estimation of telmisartan and nebivolol hydrochloride (HCl) simultaneously in its combined dosage form.Methods: The compounds were well resolved in an isocratic method using the mobile phase composition of acetonitrile: Buffer (potassium dihydrogen orthophosphate pH adjusted 3.1 with orthophosphoric acid) in a ratio of 40:60 v/v at a flow rate of 1.2 ml/min using C18 Shim-pack (150 mm × 4.6 mm, 5 μ) column. The detection was carried out at 280 nm.Results: The retention time of telmisartan and nebivolol HCl was 4.8 min and 6.5 min, respectively. The developed method was validated by evaluating various validation parameters such as linearity, precision, accuracy, robustness, specificity, limit of detection, and limit of quantification according to the international council for harmonization guidelines. The standard calibration curve was obtained in the concentration range of 24–56 μg/ml for telmisartan and 3–7 μg/ml for nebivolol HCl. The overall average % recovery was found out to be 100.35 for telmisartan and 98.84 for nebivolol HCl.Conclusion: Statistical analysis of the data showed that the method is reproducible and selective for the estimation of telmisartan and nebivolol HCl. The proposed method could be used for analysis of telmisartan and nebivolol HCl in their dosage form.


2019 ◽  
Vol 57 (7) ◽  
pp. 625-635 ◽  
Author(s):  
NVVSS Narayana Murty Nagulakonda ◽  
Ravi Shekar Ananthula ◽  
T Krishnamurthy ◽  
Muguda Ravi Prasada Rao ◽  
Gollapalli Nageswara Rao

Abstract Tazarotene is internationally accepted common name for ethyl 6-[(4,4-dimethylthiochroman-6-yl)ethynyl]nicotinate. It is a synthetic retinoid used for the topical treatment of mild to moderate plaque psoriasis, acne vulgaris and photo aging. To ensure the quality of drug product and drug substance, a LC–MS compatible UHPLC method was developed for quantification of drug and its related substances. Stationary phase with fused core particle technology is used for the separation of impurities. Limit of quantification and limit of detection of the method are 0.1 and 0.03%, respectively. Precision of the method for Tazarotene and all its related substances is less than 2.2% RSD. The correlation coefficient is >0.999. Accuracy of method is ranged from 95.3% to 107.0%. Application of this method in stability analysis has been demonstrated by analyzing stressed samples. Experimental design is used for the verification of robustness of the method. To ensure the safety, an in silico toxicity of the drug and its related substances were determined using TOPKAT and DEREK toxicity predictions Both UHPLC and in silico methods were validated as per the ICH Q2 and ICH M7 guidelines, which will enable a rapid product development of Tazarotene topical formulations while ensuring the safety and quality of product.


Author(s):  
Kanan G Gamit ◽  
Niraj Y Vyas ◽  
Nishit D Patel ◽  
Manan A Raval

Objective: A study was aimed to estimate guggulsterone-Z (GZ) in Gokshuradi Guggulu (GG).Methods: An analytical method was developed and validated using Waters Alliance high-performance liquid chromatography system (Empower software), equipped with photodiode array detector. Separation was achieved using Phenomenex, C-18 (250 mm×4.6 mm, 5 μ) column. Mobile phase consisted of acetonitrile:water (70:30,v/v). Flow rate was set to 1 ml/min and detection was performed at 251 nm.Results and Discussion: Validation parameters such as linearity, precision, accuracy, limit of detection, limit of quantification, and robustness were performed. Amount of GZ was estimated using linearity equation.Conclusion: GG was found to contain 0.815±0.03 g% w/w GZ. Validated method may be used as one of the parameters to standardize the formulation.


Author(s):  
ILMA NUGRAHANI ◽  
STEPHANIE SULISTIANA ◽  
SLAMET IBRAHIM

Objective: This study was aimed to develop a rapid analysis using FTIR (Fourier Transform Infra-Red) for papaverine hydrochloride (HCl) determination in the hair sample, supported by a mathematically manipulation; which never been reported before in toxicology and forensic analysis. Methods: Firstly, the method was checked its validity to ensure the feasibility for the quantitative purpose. The absorbance spectrums were collected by measure the drug, matrix, and its mixture. A spectra which showed the best specificity and linearity then was selected and derived. Afterwards, the area under the curve (AUC) was measured. A series of concentration was used for compose the calibration curve. Based on the result, some validation parameters were checked thoroughly. Further, for sample preparation, hair was collected non-invasively, then was decontaminated using soap. Next, it was immersed into a papaverine HCl solution at a concentration of 25 mg/ml along days. Finally, the amount of drugs absorbed were measured by the developed method using FTIR. Results: Experimental data showed that all validation parameters could be fulfilled by the developed method. The selected spectra for the content determination was 1320-1230 cm-1. Its linearity was represented by a correlation coefficient value (r) ≥ 0.9999, variation coefficient (Vxo) ≤ 2.0%. The limit of detection (LOD) was 0.00618% w/w, meanwhile, the limit of quantitation (LOQ) was 0.02060% w/w, respectively. The percent recovery was in the range 97-103% with the relative standard deviation (RSD) was ≤ 2.0%. The drug has detected after 72 h immersion, moreover, after 192 h the concentration gained was 0.1594±0.0011% w/w. Conclusion: As the conclusion, FTIR absorbance-derivative method is adequate as a rapid procedure for determine papaverine HCl in the hair sample. This method shows the appropriate of specificity, accuracy and precise. In addition, it shows the advantages of simplicity, green/eco-friendlier, and cost-efficiency.


2020 ◽  
Vol 10 (6) ◽  
pp. 49-56
Author(s):  
Sneha Jagnade ◽  
Pushpendra Soni ◽  
Lavakesh Kumar Omray

The aim of present study was to investigate the development and validation of a green analytical method for the determination of aspirin and domperidone. Method Development and Validation for Estimation of Domperidone and Aspirin in bulk or formulation by using RP-HPLC. The RP-HPLC method was developed for estimation of Aspirin and Domperidone in synthetic mixture by isocratically using 10 mM KH2PO4: Acetonitrile (20:80) as mobile phase, Prontosil C-18 column (4.6 x 250 mm, 5μparticle size) column as stationary phase and chromatogram was recorded at 231 nm. Then developed method was validated by using various parameters such as, linearity, Range accuracy, precision repeatability, intermediate precision, robustness, limit of detection, limit of quantification. The proposed methods were found to be linear with correlation coefficient close to one. Precision was determined by repeatability, Intermediate precision and reproducibility of the drugs. The robustness of developed method was checked by changing in the deliberate variation in solvent. The result obtained shows the developed methods to be Cost effective, Rapid (Short retention time), Simple, Accurate (the value of SD and % RSD less than 2), Precise and can be successfully employed in the routine analysis of these drugs in bulk drug as well as in tablet dosage form. The Simplicity, Rapidly and Reproducibility of the proposed method completely fulfill the objective of this research work. Keywords: Asprin; Domperidone; HPLC; Ultra Violet; Validation


2017 ◽  
Vol 60 (4) ◽  
Author(s):  
Guadalupe Pérez-Caballero ◽  
Nancy Muro-Hidalgo ◽  
Elvia Adriana Morales-Hipólito ◽  
Alma Villaseñor ◽  
Raquel López-Arellano

A reversed phase high-performance liquid chromatography (RP-HPLC) method for determination of Thimerosal (TMS) in topical creams was optimized and validated according to the ICH guidelines which include accuracy, precision, selectivity, robustness, limit of detection (LOD), limit of quantification (LOQ), linearity and range. For topical creams, sample treatment is often an overwhelming step essentially due to its oily nature. For the first time a simple and robust extraction procedure for TMS using phosphate buffer (pH 5.5, 0.2M) was successfully developed. This method describes the TMS quantitation by HPLC in a topical product containing 0.01% fluocinolone acetonide (FLA) as the active molecule. The HPLC separation was achieved on a Column Symmetry® and a methanol: phosphate buffer (pH 2.5, 0.05M) 70:30 v/v mobile phase and wavelength 218 nm. Results from both standards and samples showed adequate validation parameters. Noteworthy, linearity was within the range 1.2 - 2.8 μg/mL. Additionally, robustness and TMS stability were established after sample extraction. The method provides an efficient and safe quality control tool for determination of TMS in topical creams.


Author(s):  
Gudipally. Mounika ◽  
K. Bhavya Sri ◽  
R. Swethasri ◽  
M. Sumakanth

To develop an accurate, precise, specific high performance liquid chromatography method for quantification of Canagliflozin in bulk and dosage forms. A C18 column (250mm X 4.6mm; 5μm phenomenex) was used with mobile phase containing Acetonitrile-0.1% sodium acetate buffer (pH-4.6), (20:80) in isocratic mode. The flow rate maintained was 1.0ml/min and the U.V detector was operated at 291nm. The retention time of Canagliflozin was 3.307min and showed a good linearity in concentration range of 2-14μg/ml with correlation coefficient of 0.999. The average percent recovery was found to be 99.98%. The developed method follows validation parameters such as system suitability, linearity, precision, accuracy, limit of detection and limit of quantification and robustness as per ICH guidelinesQ2(R1). The proposed method was found to provide faster retention time with sharp resolution with linearity at a lowest concentration as compared to previous methods and this method is validated as per International conference on harmonization guidelines and successfully applied for bulk and pharmaceutical dosage form.


2020 ◽  
Vol 11 (2) ◽  
pp. 2070-2082
Author(s):  
Narasimha Reddy G P ◽  
Sreenivasulu Reddy T ◽  
Sidda Reddy K ◽  
Shashi Kumar K N

This work is intended to thrive a stability indicating Ultra performance liquid method for the estimation of (TLM) and (HCTZ) and degradation products pharmaceutical dosage forms. Separation was carried out on Zorbax Eclipse XDB C-18(50 x 2.1 mm, 1.7 ) column using a gradient method. Mobile phase A is 10mM KH2PO4 having 1% (v/v) of and mobile phase B is used in this work. 0.5 / minute is the flow of rate and at 271nm noticed wave length is monitored. Method development trails were carried out on six different columns. For specificity, limit of quantification, limit of detection, linearity, accuracy, method precision, robustness and stability this method is validated. Correlation coefficient of the impurities is more than 0.99. Stability indicating method confirmed that there were no interference of all impurities of TLM and HCTZ. Hence, developed LC method was stability indicating and well applied for drug product stability study as well as to quality monitoring.


Sign in / Sign up

Export Citation Format

Share Document