scholarly journals Development and Validation of a Simple Method for Routine Analysis of Ractopamine Hydrochloride in Raw Material and Feed Additives by HPLC

2009 ◽  
Vol 92 (3) ◽  
pp. 757-764 ◽  
Author(s):  
Ellen Figueiredo Freire ◽  
Keyller Bastos Borges ◽  
Hélio Tanimoto ◽  
Raquel Tassara Nogueira ◽  
Lucimara Cristiane Toso Bertolini ◽  
...  

Abstract A simple method was optimized and validated for determination of ractopamine hydrochloride (RAC) in raw material and feed additives by HPLC for use in quality control in veterinary industries. The best-optimized conditions were a C8 column (250 4.6 mm id, 5.0 m particle size) at room temperature with acetonitrile100 mM sodium acetate buffer (pH 5.0; 75 + 25, v/v) mobile phase at a flow rate of 1.0 mL/min and UV detection at 275 nm. With these conditions, the retention time of RAC was around 5.2 min, and standard curves were linear in the concentration range of 160240 g/mL (correlation coefficient 0.999). Validation parameters, such as selectivity, linearity, limit of detection (ranged from 1.60 to 2.05 g/mL), limit of quantification (ranged from 4.26 to 6.84 g/mL), precision (relative standard deviation 1.87), accuracy (ranged from 96.97 to 100.54), and robustness, gave results within acceptable ranges. Therefore, the developed method can be successfully applied for the routine quality control analysis of raw material and feed additives.

2021 ◽  
Vol 08 ◽  
Author(s):  
Kumar Janakiraman ◽  
Venkateshwaran Krishnaswami ◽  
Vaidevi Sethuraman ◽  
Vijaya Rajendran ◽  
Ruckmani Kandasamy

Aim: To develop an RP-HPLC method for the simultaneous estimation of methotrexate (MTX) and minocycline (MNC). Background: Different HPLC methods were reported for the estimation of MTX/MNC individually, but there is no report for the simultaneous estimation of both MTX and MNC in a simple method. Objective: The objective of the developed method is to utilize the method for the estimation of MTX/MNC in different pharmaceutical formulations and in biological fluids. Methods: An HPLC method for the estimation of methotrexate (MTX) and minocycline (MNC) relevance to the evaluation of nanoparticulate formulations has been developed and validated. Chromatographic estimation was achieved using the mobile phase composition of sodium acetate buffer and acetonitrile (70:30% v/v) at pH 4.0 at a flow rate of 0.2 mL/min at 307 nm. Results: The calibration curve for MTX and MNC was found to be linear at nanogram (5 to 25 ng.mL-1) and microgram (5 to 25 μg.mL-1) levels at a correlation coefficient range of 0.98 to 0.99 for both MTX/MNC. The lower limit of detection and limit of quantification were found to be 0.026 ng.mL-1 and 0.079 ng.mL-1 for MTX and MNC, respectively. The percentage relative standard deviation for validation parameters of both drugs was found to be less than 6.5%. The amount of MTX and MNC present within the nanoparticles was found to be MTX (0.84 mg/mL) and MNC (0.61 mg/mL). The in vitro release showed an immediate release pattern for MTX (64.95±2.08%) and MNC (90.90±1.78%) within 12 h. Conclusion: The developed analytical method for the simultaneous estimation of MTX and MNC was found to be simple, affordable, dynamic, low cost, rapid and easy to perform with good repeatability. This method is also time consuming, since the peaks were obtained within a moderate analysis time.


2021 ◽  
Vol 09 ◽  
Author(s):  
Ali Al-Kulabi ◽  
Louis Gooden ◽  
Ijeoma F. Uchegbu

Background: Mycophenolic acid (MPA), an immunosuppressive agent, is used orally to reduce corneal graft rejection. However its oral use is associated with gastrointestinal side effects. Objectives: To prepare MPA nanoparticle eye drops and a validated analytical method. Methods: Aqueous MPA eye drops were prepared by nanoencapsulation of MPA using Nanomerics MET (N-palamitoylN-monomethyl-N,N-dimethyl-N,N,N-trimethyl-6-O-glycolchitosan) at a MET, MPA ratio of 7.5: 1 g g-1 in the presence of glycerol (2.75% w/w). A validated MPA in-formulation drug substance assay was then developed. Results: MET-MPA formulations were prepared as well as a validated assay. Assay validation parameters for the analysis of MPA in the formulation were satisfactory [Plate count = 16458, Capacity Factor = 2.4, Tailing Factor = 1.02, linearity = 0.999 (0.016 – 0.5 mg mL-1 ), limit of detection = 0.056 mg mL-1 , limit of quantification = 0.17 mg mL-1 , accuracy = 98%, intraday and interday relative standard deviation = 0.45% and 4% respectively]. The candidate formulation (z - average mean = 66 ± 0.4 nm, polydispersity index = 0.12 ± 0.012, drug content = 1.14 ± 0.003 mg mL-1 , zeta potential = +8.5 ± 1.4 mV, pH = 7.4 ± 0.02, osmolarity = 309 ± 1.5 mOSm L-1 , viscosity = 1.04 ± 0.001 mPa.s) was then found to be stable for 14 days with respect to drug content at refrigeration, room and accelerated (40C )temperature and. All other formulation parameters were within the ocular comfort range. Conclusions: A validated assay (ICH and US FDA guidelines) for new MPA nanoparticle eye drops has been developed.


Author(s):  
DAVID ALEXANDER ◽  
Abdul Rohman

Objective: The aim of this research was to validate inductively coupled plasma-atomic emission spectroscopy (ICP-AES) for quantitative analysis of cadmium (Cd), chromium (Cr), cuprum (Cu), mangan (Mn) and nickel (Ni) in milk products. Methods: The heavy metals in milk were determined using ICP-AES at optimized wavelength. The method was validated by assessing several validation parameters which included linearity and range, accuracy, precision and sensitivity expressed by the limit of detection and limit of quantification. The validated method was then used for the analysis of milks commercially available. Results: ICP-AES for determination of Cd, Cr, Cu, Mn, and Ni was linear over a certain concentration range with a coefficient correlation value of>0.997. The limit of quantification values of Cd, Cr, Cu, Mn, and Ni were 0.0047; 0.0050; 0.0066; 0.0061; and 0.0169 µg/ml, respectively. The precision of analytical method exhibited relative standard deviation (RSD) values of 3.18%; 4.17%; 3.05%; 2.93%; and 4.47% during repeatability test and 5.28%; 5.06%; 3.67%; 3.67%; and 11.17% during intermediate precision of Cd, Cr, Cu, Mn, and Ni respectively. The recoveries of these metals assessed using standard addition method were 92.25; 90.88; 102.87; 94.50; and 86.85%, respectively. Conclusion: ICP-AES offered a reliable and fast method for the determination of heavy metals in milk products. The developed method could be proposed as an official method for determination of heavy metals in milk products.


Author(s):  
Ayya Rajendra Prasad ◽  
Jayanthi Vijaya Ratna

 Objective: The objective of this study was developed and validated a novel, specific, precise, and simple ultraviolet (UV)-spectrophotometric method for the estimation of norfloxacin present in taste masked drug-resin complex.Methods: UV-spectrophotometric determination was performed with ELICO SL 1500 UV-visible spectrophotometer using 0.1 N HCl as a medium. The spectrum of the standard solution was run from 200 to 400 nm range for the determination of absorption maximum (λ max). λ max of norfloxacin was found at 278 nm. The absorbance of standard solutions of 1, 2, 3, 4, and 5 μg/ml of drug solution was measured at an absorption maximum at 278 nm against the blank. Then, a graph was plotted by taking concentration on X-axis and absorbance on Y-axis which gave a straight line. Validation parameters such as linearity and range, selectivity and specificity, limit of detection (LOD) and limit of quantification (LOQ), accuracy, precision, and robustness were evaluated as per the International Conference on Harmonization (ICH) guidelines.Results: Linearity for the UV-spectrophotometric method was noted over a concentration range of 1–5 μg/ml with a correlation coefficient of 0.9995. The LOD and LOQ for norfloxacin were found at 0.39 μg/ml and 1.19 μg/ml, respectively. Accuracy was in between 99.00% and 99.17%. % relative standard deviation for repeatability, intraday precision, and interday precision was found to be 0.600, in between 0.291 and 0.410, and in between 0.682 and 1.439, respectively. The proposed UV spectrophotometric method is found to be robust.Conclusion: The proposed UV-spectrophotometric method was validated according to the ICH guidelines, and results and statistical parameters demonstrated that the developed method is sensitive, precise, reliable, and simple for the estimation of norfloxacin present in taste masked drug-resin complex.


Author(s):  
Alok Pratap Singh ◽  
Iti Chauhan ◽  
Snigdha Bhardwaj ◽  
Praveen Gaur ◽  
S Sadish Kumar ◽  
...  

Introduction: Azithro-mycin a semi-synthetic, azalide congener of erythro-mycin indicated in the treatment of respiratory tract infections. Various methods available for determination of Azithro-mycin, but HPLC are most versatile one. Objective: The present study is based on the development and validation of a rapid, simple high performance liquid chromatography (HPLC) method equipped with UV detector for quantitative analysis of Azithro-mycin (AZN) in suspension. Material and methods: The Method was performed by using Hypersil BDS-C18 (250 mm × 4.6 mm i.d.) column MS-II, with an isocratic mobile phase of methanol, acetonitrile and phosphate buffer pH 8 (60:30:10; v/v) with run time 15 minutes. The determinations were performed at a flow rate of 1.0ml/min, and UV detector set at 212 nm. Result and Discussion: The method was found to be specific with relative standard deviation (RSD) less than 2.09%. The method showed accuracy with RSD less than 1.34% and precision in repeatability with RSD less than 1.42%. The method was found to be linear over a wide range of concentration from 1.0 to 50.0 μg/mL (R2 = .995). Limit of detection and limit of quantification were found to be 14.40 ng/mL and 43.66 ng/mL respectively. Conclusion: It was advantageous to use UV detector over other methods employing electrochemical, photodiode array etc. as the detector, because of cheap and easy availability. The developed method fulfilled all validation parameters as per ICH and can be successfully applied to quantify percent drug content in marketed oral Azithro-mycin suspension.


Author(s):  
SAI PRUDHVI N. ◽  
VENKATESWARLU B. S. ◽  
KUMUDHAVALLI M. V. ◽  
MURUGANANTHAM V.

Objective: The present work aimed to develop a novel, reliable and accurate Liquid Chromatography-Mass Spectrometry/Mass spectrometry (LC-MS/MS) method for the simultaneous quantification of Decitabine and Cedazuridine a combined medication used for the treatment of chronic myelomonocytic leukemia in human plasma. Methods: Talazoparib drug is used as an internal standard in the study. Both the analytes and internal standard were isolated from 100 ml plasma samples by liquid-liquid extraction and then chromatographed on Zorbax SB-CN (4.6 mm×75 mm, 3.5 µm) column with a mobile phase consisting of 0.1 % ammonium formate and methanol in the ratio of 65:45 (v/v) pumped at 0.5 ml/min. The method had a chromatographic total run time of 5 min. Results: The developed method gave a symmetric peak at a retention time of 1.7 min for Decitabine, 2.2 min for Cedazuridine, 3.5 min for Talazoparib and satisfied all the peak properties as per USP guidelines. The mass spectral characterization of separated analytes in the LC method was performed using a mass detector operated at Multiple Reaction Monitoring mode with precursor-to-product ion transitions at m/z of 229 to m/z of 114 as MH+ion for Decitabine, m/z of 269 to m/z of 118 as MH+ion for Cedazuridine. A very sensitive limit of detection of 0.3 ng/ml was observed and showed a calibration curve linear over the concentration range of LLOQ (lower limit of quantification) to 500 ng/ml. The other validation parameters were found to have acceptable accuracy, precision, linearity, and selectivity. The mean extraction concentration was acceptable and very high for both the analytes in HQC (high-quality control concentration), MQC (medium quality control concentration) and LLOQ levels. The peak area response ratio of Decitabine and Cedazuridine with the internal standard in freeze-thaw, short term and long term stability studies was found to be acceptable confirms that the method is stable. Conclusion: It can be concluded that the proposed method is specific, accurate, and precise and could be used for the simultaneous estimation of Decitabine and Cedazuridine in human plasma.


Author(s):  
Ankita Panchal ◽  
Gaurav Sanghvi ◽  
Ashish Vachhani ◽  
Navin Sheth ◽  
Devendra Vaishnav

A simple, sensitive, specific, and cost effective method for simultaneous determination of Aspirin and Rosuvastatin calcium was developed and validated in single dosage formulation. The sample solution of ASP and RSTC was prepared using methanol as a solvent. Separation of ASP and RSTC was achieved with a mobile phase consisting of 20 mM KH2PO4 : Methanol (30:70 v/v) at a flow rate of 1.0 ml/min. Separations were performed on Merck hibar 250-4.6 RP18 (5 µm) column (150 mm X 3.0 mm), using a Shimadzu Prominence HPLC system equipped with a Shimadzu SPD-20A detector, Rhenodyne 7725i injector with 20 μL loop, LC-20 AD pump, CBM-20 Alite controller and LC Solution software. Retention times of ASP and RSTC were 3.747 and 5.969 minutes respectively. Absolute recovery of ASP and RSTC was 100.3 and 100.03 % respectively. The lower limit of quantification (LLOQ) of ASP and RSTC was 0.3097 and 0.1063 ppm and lower limit of detection (LLOD) of ASP and RSTC was 0.01535 and 0.01358 ppm respectively. Linearity was established for the range of concentrations 15.00-90.0 μg/ml and 2.0-12.0 μg/ml for ASP and RSTC respectively with the coefficient of determination (R2) of 0.994 and 0.999 for both the compounds. The inter- and intra-day precision in the measurement of ASP quality control (QC) sample 75 μg/ml, were in the range 0.1-0.2 % relative standard deviation (R.S.D.) and 0.2-0.3 % R.S.D., respectively. The inter- and intra-day precision in the measurement of RST quality control (QC) sample 10 μg/ml, were in the range 0.1-0.2 % R.S.D., and 0.0-0.3 % R.S.D., respectively. The developed method would be applicable for routine quality control of ASP And RSTC in bulk as well as in pharmaceutical formulations


Foods ◽  
2021 ◽  
Vol 11 (1) ◽  
pp. 41
Author(s):  
Se-Eun Park ◽  
Hyo-Yeon Yu ◽  
Sangdoo Ahn

This study focuses on developing a quantification method for phosphatidylcholine (PC) and total phospholipid (PL) in krill oil using Fourier-transform infrared (FT-IR) spectroscopy. Signals derived from the choline and phosphate groups were selected as indicator variables for determining PC and total PL content; calibration curves with a correlation coefficient of >0.988 were constructed with calibration samples prepared by mixing krill oil raw material and fish oil in different ratios. The limit of detection (LOD, 0.35–3.29%) of the method was suitable for the designed assay with good accuracy (97.90–100.33%). The relative standard deviations for repeatability (0.90–2.31%) were acceptable. Therefore, both the methods using absorbance and that using second-derivative were confirmed to be suitable for quantitative analysis. When applying this method to test samples, including supplements, the PC content and total PL content were in good agreement with an average difference of 2–3% compared to the 31P NMR method. These results confirmed that the FT-IR method can be used as a convenient and rapid alternative to the 31P NMR method for quantifying PLs in krill oil.


BMC Chemistry ◽  
2021 ◽  
Vol 15 (1) ◽  
Author(s):  
Yalda Pasandideh ◽  
Habib Razmi

Abstract Background Solid-phase microextraction (SPME) is a versatile sampling and sample preparation technology that possess a significant application in the extraction and pre-concentration of a broad range of micro-pollutants from different kind of matrices. Selection and preparation of an appropriate fiber substrate and coating materials have always been the main challenges of the SPME procedure. This paper introduces a high-efficiency metal-based SPME fiber with a new chemical coating of nickel/graphene oxide/nickel tetraazamacrocyclic complex (Ni/GO/NiTAM). Result The Ni/GO/NiTAM sorbent was electroless deposited onto the surface of an aluchrom (Alu) wire, and then the prepared fiber was employed for the extraction and pre-concentration of some PAHs before their HPLC–UV analysis. The prepared fiber characterization data were assessed using FE-SEM, EDX, XRD, FT-IR, and BET techniques. The method validation parameters, including the linearity range (LRs: 0.10 to 200.0 µg L−1), the limit of detection (LODs: 0.03‒0.30 µg L−1), and the limit of quantification (LOQs: 0.10–1.00 µg L−1), under optimal conditions. The relative standard deviations (RSDs) of intra-day, inter-day, and single fiber repeatability (for the samples spiked at 25 µg L‒1) were in the range of 0.32–2.94, 1.20–4.09, and 1.42‒4.39%, respectively. In addition, the technique recoveries (RR %) and enrichment factors (EF) were in the range of 83.10‒107.80% and 83–164, respectively. Conclusion The fiber fabrication was simple, and the applied materials were also economical and easily accessible. Alu metal has high physicochemical and mechanical stability and thus can be a good alternative for the substrate of the fragile commercial SPME fibers. High rigidity and durability, long service life, and high extraction capability are some of the other advantages of the offered fiber.


Author(s):  
Antonello Cicero ◽  
Francesco Giuseppe Galluzzo ◽  
Gaetano Cammilleri ◽  
Andrea Pulvirenti ◽  
Giuseppe Giangrosso ◽  
...  

We developed, validated, and confirmed with proficiency tests a fast ultra-high-performance liquid chromatography with diode array detector (UHPLC-DAD) method to determine histamine in fish and fishery products. The proposed method consists of two successive solid–liquid extractions: one with a dilute solution of perchloric acid (6%) and the second only with water. The instrumental analysis with UHPLC provides a very fast run time (only 6 min) with a retention time of approximately 4 min, a limit of quantification (LOQ) of 7.2 mg kg−1, a limit of detection (LOD) of 2.2 mg kg−1, a recovery around 100%, a relative standard deviation (RSD%) between 0.5 and 1.4, and an r2 of calibration curve equal to 0.9995. The method detected optimal values of the validation parameters and required a limited number of reagents in comparison to other methods reported in the literature. Furthermore, the method could detect histamine in a very short time compared with other methods. This method, in addition to being validated, precise, specific, and accurate, avoids wasting time, money, and resources, and limits the use of organic solvents.