scholarly journals Removal of Total Coliforms, Thermotolerant Coliforms, and Helminth Eggs in Swine Production Wastewater Treated in Anaerobic and Aerobic Reactors

2014 ◽  
Vol 2014 ◽  
pp. 1-11 ◽  
Author(s):  
Silvia Helena Zacarias Sylvestre ◽  
Estevam Guilherme Lux Hoppe ◽  
Roberto Alves de Oliveira

The present work evaluated the performance of two treatment systems in reducing indicators of biological contamination in swine production wastewater. System I consisted of two upflow anaerobic sludge blanket (UASB) reactors, with 510 and 209 L in volume, being serially arranged. System II consisted of a UASB reactor, anaerobic filter, trickling filter, and decanter, being also organized in series, with volumes of 300, 190, 250, and 150 L, respectively. Hydraulic retention times (HRT) applied in the first UASB reactors were 40, 30, 20, and 11 h in systems I and II. The average removal efficiencies of total and thermotolerant coliforms in system I were 92.92% to 99.50% and 94.29% to 99.56%, respectively, and increased in system II to 99.45% to 99.91% and 99.52% to 99.93%, respectively. Average removal rates of helminth eggs in system I were 96.44% to 99.11%, reaching 100% as in system II. In reactor sludge, the counts of total and thermotolerant coliforms ranged between 105and 109 MPN (100 mL)−1, while helminth eggs ranged from 0.86 to 9.27 eggs g−1 TS.

2005 ◽  
Vol 51 (12) ◽  
pp. 91-97 ◽  
Author(s):  
M. von Sperling ◽  
R.K.X. Bastos ◽  
M.T. Kato

Ponds following anaerobic reactors, such as Upflow Anaerobic Sludge Blanket (UASB) reactors, have been termed polishing ponds in the literature. The present paper analyses the removal of E. coli and helminth eggs in five UASB–polishing pond systems in Brazil. Since there were ponds in series, the total number of ponds was 10. The ponds had average retention times varying from 2 to 21 days, and depths ranging from 0.40 to 2.00 m. The shallow ponds in series, even with low retention times, were able to produce effluents complying with the coliform WHO guidelines for unrestricted irrigation (≤1000 MPN/100 ml). An equation for the coliform decay coefficient was proposed: Kb (dispersed flow)=0.710 H−0.955 (20 °C). The equation highlights the inverse relationship between the pond depth and the decay coefficient. All polishing pond systems were able to produce effluents with helminth eggs concentrations predominantly equal to zero, and satisfying the WHO guidelines for unrestricted and restricted irrigation (≤1 egg/L, arithmetic mean). The approximate range of helminth eggs removal efficiency was predicted satisfactorily.


2001 ◽  
Vol 44 (4) ◽  
pp. 79-82 ◽  
Author(s):  
L. F. Lopes ◽  
P. R. Koetz ◽  
M. S. Santos

Parboiled rice industry is one of main food industries in the south of Brazil. The main parts of the processing are the humidification and gelatinization of the grain. This procedure increases the productivity and nutritive and cooking values of the product. Some of these industries in the region utilize upflow anaerobic sludge blanket (UASB) reactors as a biological treatment for carbon removal. For nitrogen removal, the proposed system aims to eliminate an extra denitrification reactor, making this step in the top of the UASB, an anoxic zone of the reactor. Nitrification was performed in aerated mixed reactor of 3,6 L. A fraction of the NR was recycled in the top of UASB reactor above the sludge blanket. Recycled ratio varied from 0; 1:0.5; 1:1.0; to 1:1.5. The maximum removal efficiency of NTK was 80%. The results confirm the viability of the proposed system for denitrification.


2012 ◽  
Vol 66 (6) ◽  
pp. 1239-1246 ◽  
Author(s):  
Fernando Augusto Lopes de Assunção ◽  
Marcos von Sperling

This study aimed at determining the influence of ammonia volatilization on nitrogen removal in polishing (maturation) ponds treating sanitary effluent from upflow anaerobic sludge blanket (UASB) reactors in the city of Belo Horizonte, Brazil. An apparatus for the capture and absorption of volatilized ammonia in three polishing ponds in series was installed. Volatilized ammonia was captured by a chamber on the surface of the ponds and dissolved in boric acid solution, in order to estimate the amount of ammonia per unit surface area of each pond. Low rates of volatilization, below 0.2 kg/ha.d, in about 75% of samples from all the ponds, were observed. The mass balance of ammonia nitrogen of the ponds showed that the volatilization represented only about 2% of the total removal of nitrogen from the polishing ponds. The results obtained suggest that ammonia volatilization was a mechanism of little importance in nitrogen removal in the investigated polishing ponds.


1995 ◽  
Vol 31 (1) ◽  
pp. 249-259 ◽  
Author(s):  
Nina Christiansen ◽  
Hanne V. Hendriksen ◽  
Kimmo T. Järvinen ◽  
Birgitte K. Ahring

Data on anaerobic degradation of chloroaromatic compounds in Upflow Anaerobic Sludge Blanket Reactors (UASB-reactor) are presented and compared. Special attention is given to the metabolic pathways for degradation of chlorinated phenols by granular sludge. Results indicate that PCP can be degraded in UASB-reactors via stepwise dechlorination to phenol. Phenol will subsequently be converted to benzoate before ring cleavage. Dechlorination proceeds via different pathways dependent upon the inocula used. Results are further presented on the design of special metabolic pathways in granules which do not possess this activity using the dechlorinating organism, Desulfomonile tiedjei. Additionally, it is shown that it is possible to immobilize Dechlorosporium hafniense, a newly isolated dechlorinating anaerobe, into granular sludge, thereby introducing an ability not previously present in the granules.


2013 ◽  
Vol 33 (2) ◽  
pp. 367-378 ◽  
Author(s):  
Estevão Urbinati ◽  
Rose M. Duda ◽  
Roberto A. de Oliveira

In this study it was evaluated the effects of hydraulic retention time (HRT) and Organic Loading Rate (OLR) on the performance of UASB (Upflow Anaerobic Sludge Blanket) reactors in two stages treating residual waters of swine farming. The system consisted of two UASB reactors in pilot scale, installed in series, with volumes of 908 and 188 L, for the first and second stages (R1 and R2), respectively. The HRT applied in the system of anaerobic treatment in two stages (R1 + R2) was of 19.3, 29.0 and 57.9 h. The OLR applied in the R1 ranged from 5.5 to 40.1 kg CODtotal (m³ d)-1. The average removal efficiencies of chemical oxygen demand (COD) and total suspended solids (TSS) ranged, respectively, from 66.3 to 88.2% and 62.5 to 89.3% in the R1, and from 85.5 to 95.5% and 76.4 to 96.1% in the system (R1 + R2). The volumetric production of methane in the system (R1 + R2) ranged from 0.295 to 0.721 m³CH4 (m³ reactor d)-1. It was found that the OLR applied were not limiting to obtain high efficiencies of CODtotal and TSS removal and methane production. The inclusion of the UASB reactor in the second stage contributed to increase the efficiencies of CODtotal and TSS removal, especially, when the treatment system was submitted to the lowest HRT and the highest OLR.


2011 ◽  
Vol 64 (3) ◽  
pp. 610-617 ◽  
Author(s):  
Tarek Elmitwalli ◽  
Ralf Otterpohl

The treatment of grey water in two upflow anaerobic sludge blanket (UASB) reactors, operated at different hydraulic retention times (HRTs) and temperatures, was investigated. The first reactor (UASB-A) was operated at ambient temperature (14–25 °C) and HRT of 20, 12 and 8 h, while the second reactor (UASB-30) was operated at controlled temperature of 30 °C and HRT of 16, 10 and 6 h. The two reactors were fed with grey water from ‘Flintenbreite’ settlement in Luebeck, Germany. When the grey water was treated in the UASB reactor at 30 °C, total chemical oxygen demand (CODt) removal of 52–64% was achieved at HRT between 6 and 16 h, while at lower temperature lower removal (31–41%) was obtained at HRT between 8 and 20 h. Total nitrogen and phosphorous removal in the UASB reactors were limited (22–36 and 10–24%, respectively) at all operational conditions. The results showed that at increasing temperature or decreasing HRT of the reactors, maximum specific methanogenic activity of the sludge in the reactors improved. As the UASB reactor showed a significantly higher COD removal (31–64%) than the septic tank (11–14%) even at low temperature, it is recommended to use UASB reactor instead of septic tank (the most common system) for grey water pre-treatment. Based on the achieved results and due to high peak flow factor, a HRT between 8 and 12 h can be considered the suitable HRT for the UASB reactor treating grey water at temperature 20–30 °C, while a HRT of 12–24 h can be applied at temperature lower than 20 °C.


1986 ◽  
Vol 18 (12) ◽  
pp. 55-69 ◽  
Author(s):  
M. E. Souza

This paper describes and discusses the principal ideas and parameters related to the application, design and operation of wastewater treatment systems using the upflow anaerobic sludge blanket reactor (UASB). The differences in the process brought about by the high or low concentration of organic material in the wastewater to be treated are pointed out in each consideration. The purpose of this paper is to make the development of simple, but safe and efficient UASB reactor treatment units, by technicians not necessarily highly specialized in the subject, possible. It also attempts to point out problems which are not yet completely solved in order to help in the preparation of future research and development plans. A number of possible questions that deal with the following subjects are discussed:–types of waste which can be treated by the UASB reactor–concentrated wastes (for example, stillage from sugar-cane) and diluted wastes (for example, domestic sewage)–necessity of pre- and post-treatment–temperature–shape and dimensions of the reactor–criteria and details for design–start-up, operation and control of the unit–forecasts of efficiency, costs, etc.


2002 ◽  
Vol 45 (10) ◽  
pp. 207-212 ◽  
Author(s):  
A. Palenzuela-Rollon ◽  
G. Zeeman ◽  
H.J. Lubberding ◽  
G. Lettinga ◽  
G.J. Alaerts

The performance of one-step UASB reactors treating fish processing wastewater of different lipid levels was determined using artificially generated influent simulating that of the canning of sardines and tuna. The organic loading rates (OLR) and the hydraulic retention times (HRT) were 5–8 g COD.L−1.d−1 and 11–12 hours, respectively. In treating a wastewater that contains 3–4 g.L−1 total COD of which 5–9% was lipids, the COD removal and conversion to methane were ca.78% and 61%, respectively. In treating a wastewater with a higher lipid content (ca. 47% of the total COD), the total COD removed and converted to methane were 92% and 47%, respectively. A considerable part of the influent total COD was removed via adsorption on reactor surfaces and sludge particles. The adsorption of lipids on sludge particles threatens the stability of the UASB operation. Thus, the performance of a first-step UASB reactor in removing suspended solids (SS) from a “high-lipid” wastewater was also determined in this study.


2013 ◽  
Vol 33 (4) ◽  
pp. 808-819 ◽  
Author(s):  
Marcelo Bruno ◽  
Roberto A. de Oliveira

In this study it was evaluated the efficiency of the treatment of wet-processed coffee wastewater in upflow anaerobic sludge blanket (UASB) reactors in two stages, in bench scale, followed by post-treatment with activated sludge in batch. The first UASB reactor was submitted to an hydraulic retention time (HRT) of 6.2 d and organic loading rates (OLR) of 2.3 and 4.5g CODtotal (L d)-1, and the second UASB reactor to HRT of 3.1 d with OLR of 0.4 and 1.4g CODtotal (L d)-1. The average values of the affluent CODtotal increased from 13,891 to 27,926mg L-1 and the average efficiencies of removal of the CODtotal decreased from 95 to 91%, respectively, in the UASB reactors in two stages. The volumetric methane production increased from 0.274 to 0.323L CH4 (L reactor d)-1 with increment in the OLR. The average concentrations of total phenols in the affluent were of 48 and 163mg L-1, and the removal efficiencies in the UASB reactors in two stages of 92 and 90%, respectively, and increased to 97% with post-treatment. The average values of the removal efficiencies of total nitrogen and phosphorus were of 57 to 80% and 44 to 60%, respectively, in the UASB reactors in two stages and increased to 91 and 84% with the post-treatment.


Water ◽  
2019 ◽  
Vol 11 (4) ◽  
pp. 806 ◽  
Author(s):  
Mohammed Ali Musa ◽  
Syazwani Idrus ◽  
Hasfalina Che Man ◽  
Nik Norsyahariati Nik Daud

Cattle slaughterhouse wastewater (CSWW) with an average chemical oxygen demand (COD) and biochemical oxygen demand of 32,000 mg/L and 17,000 mg/L, respectively, can cause a severe environmental hazard if discharged untreated. Conventional upflow anaerobic sludge blanket (UASB) reactor is used in the treatment of slaughterhouse wastewater to meet the discharge standard limit of wastewater discharge set by the Department of Environment Malaysia (DOE). However, at higher loading rates the conventional systems are characterized by slow-growing microorganism resulting in long startup period, surface scum formation, and sludge washout. In this work, the performance of two laboratory scale (12 L) conventional (R1) and modified (R2) UASB reactors treating CSWW at mesophilic (36 ± 1 °C) condition were investigated. Both reactors were subjected to increasing organic loading rate (OLR) from 1.75 to 32 g L−1 day−1. The average COD, BOD5, and TSS removal efficiencies were ˃90%, at an OLR between 1.75 to 5 g L−1 day−1. The study revealed that R1 drastically reduced to 50, 53, and 43% with increasing OLR until 16 g L−1 day−1, whereas R2 maintained 76, 77, and 88% respectively, under the same OLR. Sign of reactor instability was very much pronounced in R1, showing poorly active Methanosaeta spp., whereas R2 showed a predominantly active Methanosarcina spp.


Sign in / Sign up

Export Citation Format

Share Document