scholarly journals Experimental Study of Hysteretic Steel Damper for Energy Dissipation Capacity

2015 ◽  
Vol 2015 ◽  
pp. 1-12 ◽  
Author(s):  
Daniel R. Teruna ◽  
Taksiah A. Majid ◽  
Bambang Budiono

This study aims to evaluate energy absorption capacity of hysteretic steel damper for earthquake protection of structures. These types of steel dampers are fabricated from mild steel plate with different geometrical shapes on the side part, namely, straight, concave, and convex shapes. The performance of the proposed device was verified experimentally by a series of tests under increasing in-plane cyclic load. The overall test results indicated that the proposed steel dampers have similar hysteretic curves, but the specimen with convex-shaped side not only showed stable hysteretic behavior but also showed excellent energy dissipation capabilities and ductility factor. Furthermore, the load-deformation relation of these steel dampers can be decomposed into three parts, namely, skeleton curve, Bauschinger part, and elastic unloading part. The skeleton curve is commonly used to obtain the main parameters, which describe the behavior of steel damper, namely, yield strength, elastic stiffness, and postyield stiffness ratio. Moreover, the effective stiffness, effective damping ratio, cumulative plastic strain energy, and cumulative ductility factor were also derived from the results. Finally, an approximation trilinear hysteretic model was developed based on skeleton curve obtained from experimental results.

2011 ◽  
Vol 261-263 ◽  
pp. 576-580
Author(s):  
Xiao Jing Yuan ◽  
Fan Liu

Flexible piers have been widely used in bridge engineering due to its superior ductility. The stirrup ratio and slenderness ratio were deemed to have a most important impact on hysteretic behavior of them. Five flexible piers were made under static vertical loads and low cyclic horizontal reversed loads. The process of test was introduced and failure mechanism, hysteretic behavior, skeleton curve, ductility, energy dissipation capacity, and stiffness degeneration of flexible piers were analyzed. Experimental studies show that (1) Failure mode of specimen is bending failure and their ductility factor falls between 4.15 and 6.30; (2) displacement ductility factor improves with increasing of the stirrup ratio. Stirrup could greatly improve the capacity on ductility and energy dissipation, while it has little impact on the bearing capacity; (3) ultimate bearing capacity decline with the increase of slenderness ratio, however, when the slenderness ratio member is larger, the hysteresis curve is fuller and energy-dissipation is better.


2018 ◽  
Vol 12 (1) ◽  
pp. 47-61
Author(s):  
Wenjuan Lv ◽  
Baodong Liu ◽  
Ming Li ◽  
Lin Li ◽  
Pengyuan Zhang

Background: For reinforced concrete structures under different humid conditions, the mechanical properties of concrete are significantly affected by the moisture content, which may result in a great change of the functional performance and bearing capacity. Objective: This paper presents an experiment to investigate the influence of the moisture content on the dynamic characteristics and hysteretic behavior of reinforced concrete column. Results: The results show that the natural frequency of reinforced concrete columns increases quickly at an early stage of immersion, but there is little change when the columns are close to saturation; the difference between the natural frequencies before and after cyclic test grows as the moisture content rises. The damping ratio slightly decreases first and then increases with the increase of moisture content; the damping ratio after the cyclic test is larger than before the test due to the development of the micro-cracks. Conclusion: The trend of energy dissipation is on the rise with increasing moisture content, although at an early stage, it decreases slightly. According to the experimental result, a formula for the moisture content on the average energy dissipation of reinforced concrete columns is proposed.


2020 ◽  
Vol 2020 ◽  
pp. 1-18
Author(s):  
Yanhua Wang ◽  
Yan Feng ◽  
Dongsheng Huang ◽  
Zirui Huang ◽  
Zhongfan Chen

In this paper, a restoring force model, composed of a trilinear skeleton curve and hysteretic rules, is proposed based on nine pseudostatic tests of the energy-dissipation joint under horizontal low cyclic loading. The critical points of the simplified skeleton curve are obtained via theoretical derivation and FE simulation. The hysteretic rules for the joints are simplified as a concave hexagon, where the parameters of the critical points are optimized by the genetic algorithm (GA). Using the established trilinear skeleton curve, three different working stages, i.e., elastic, hardening, and softening, were divided by the critical points and the moment stiffness of three stages can be calculated. The proposed hysteretic rules of each stage can reveal and explain the “pinching” in the cyclic loading, which make it easier to understand the mechanism of the energy-dissipation joint. The comparison between the restoring force model and the tests shows that the simplified skeleton curves, the established hysteretic rules, and the ductility and the damping ratio are consistent with the experimental results. Finally, the effectiveness of the established restoring force model is verified.


Author(s):  
E. Satria ◽  
L. Son ◽  
M. Bur ◽  
M. Dzul Akbar

In seismic areas, the application of structural dampers becomes compulsory in the design of buildings. There are various types of dampers, such as viscous elastic dampers, viscous fluid dampers, friction dampers, tune mass dampers, yielding/ metallic dampers, and magnetic dampers. All damper systems are designed to protect structural integrities, control damages, prevent injuries by absorbing earthquake energy, and reduce deformation. This paper is a part of research investigating the behaviour of the U-shaped steel damper (as one type of metallic damper) that can be applied to the buildings in seismic areas. The dampers are used as connections between the roof and supporting structure, with the two general purposes. The first is to control the displacement of roof under an earthquake, and the second is to absorb seismic energy through the plasticity of some parts in dampers. If a strong earthquake occurs, the plasticity will absorb the seismic energy; therefore, heavy damage could be avoided from the roof’s mainframes. In this paper, several models of U-shaped steel dampers are introduced. Several parameters, such as elastic stiffness, maximum strength, and energy dissipation, are determined under two conditions. Firstly, static analysis of the proposed damper under variation of U-steel plate configurations, searching the model with more significant energy dissipation. Secondly, static analysis of the unsymmetrical and symmetrical damper under different loading directions. An in-house finite element program that involves both geometrical and material nonlinearities is developed as a problem solver. A quasi-static lateral loading is given to each model until one cycle of the hysteresis curve is reached (in the displacement range between -20 mm to +20 mm). The above parameters are calculated from the hysteresis curve. From the results, the behaviour of the U-steel damper can be described as follows. Firstly, increasing the energy dissipation in the lateral direction can be done by increasing the lateral stiffness of the damper. However, it can reduce the maximum elastic deformation of the damper. Secondly, under the random direction of loading, a symmetrical shape can increase the energy dissipation of the damper.


2021 ◽  
Vol 2021 ◽  
pp. 1-16
Author(s):  
Jing Zhang ◽  
Zhi-Fang Liu ◽  
Yong Xu ◽  
Mai-Li Zhang ◽  
Liu-Cheng Mo

Under varying humidity and temperature conditions, with the constraint of metal fasteners to wood shrinkage, cracks along the bolt lines are generally observed in bolted glulam joints. A three-dimensional (3D) numerical model was established in software package ANSYS to investigate the cyclic behavior of bolted glulam joints with local cracks. A reversed cyclic loading was applied in the parallel-to-grain direction. The accuracy of numerical simulation was proved by comparison with full-scale experimental results. Typical failure modes were reproduced in the numerical analysis with the application of wood foundation zone material model and cohesive zone material model. The effect of crack number and length on the hysteretic behavior of bolted glulam joints was quantified by a parametric study. It was found that initial cracks impair the peak capacity and elastic stiffness of bolted glulam joints significantly. More decrease in capacity was observed in joints with more cracks, and longer cracks affect elastic stiffness more dramatically. Moreover, with the existence of initial cracks, the energy dissipated and equivalent viscous damping ratio of bolted joints are reduced by 24% and 13.3%, respectively.


2018 ◽  
Vol 2018 ◽  
pp. 1-15
Author(s):  
Qin Zhang ◽  
Zong-yan Wei ◽  
Jin-xin Gong ◽  
Ping Yu ◽  
Yan-qing Zhang

In order to determine the energy dissipation capacity of flexure critical reinforced concrete (RC) columns reasonably, an expression for describing the hysteretic behavior including loading and unloading characteristics of flexure critical RC columns is presented, and then, a new equivalent viscous damping (EVD) ratio model including its simplified format, which is interpreted as a function of a displacement ductility factor and a ratio of secant stiffness to yield stiffness of columns, is developed based on the proposed hysteretic loop expression and experimental data from the PEER column database. To illustrate the application of the proposed equivalent damping ratio model, a case study of pushover analysis on a flexure critical RC bridge with a single-column pier is provided. The analytical results are also compared with the results obtained by other models, which indicate that the proposed model is more general and rational in predicting energy dissipation capacity of flexure critical RC structures subjected to earthquake excitations.


2011 ◽  
Vol 211-212 ◽  
pp. 186-189
Author(s):  
Hai Jun He ◽  
Ji Ping Hao ◽  
Xian Lei Cao

The seismic performance of K-shape eccentrically frames were researched by cyclic loading test method, in order to understand earthquake performance, stiffness degradation and dissipation mechanism of energy. It can be concluded that K-shape eccentrically frames provide high elastic stiffness and demonstrate excellent energy dissipation capacity in the plastic stage, the different length of the link beam of different layers has great influence on the energy dissipation capacity of the structure, when shear yielding of link beam occurs, stiffness degradation become apparent, the hysteretic curves were plump in shapes. Therefore, K-shape eccentrically frames have better hysteretic behavior and energy dissipation capacity, the results can provide a reference for the engineering design and related research.


2019 ◽  
Vol 2019 ◽  
pp. 1-14
Author(s):  
Xiuyan Hu ◽  
Qingjun Chen ◽  
Dagen Weng ◽  
Ruifu Zhang ◽  
Xiaosong Ren

In the design of damped structures, the additional equivalent damping ratio (EDR) is an important factor in the evaluation of the energy dissipation effect. However, previous additional EDR estimation methods are complicated and not easy to be applied in practical engineering. Therefore, in this study, a method based on energy dissipation is developed to simplify the estimation of the additional EDR. First, an energy governing equation is established to calculate the structural energy dissipation. By means of dynamic analysis, the ratio of the energy consumed by dampers to that consumed by structural inherent damping is obtained under external excitation. Because the energy dissipation capacity of the installed dampers is reflected by the additional EDR, the abovementioned ratio can be used to estimate the additional EDR of the damped structure. Energy dissipation varies with time, which indicates that the ratio is related to the duration of ground motion. Hence, the energy dissipation during the most intensive period in the entire seismic motion duration is used to calculate the additional EDR. Accordingly, the procedure of the proposed method is presented. The feasibility of this method is verified by using a single-degree-of-freedom system. Then, a benchmark structure with dampers is adopted to illustrate the usefulness of this method in practical engineering applications. In conclusion, the proposed method is not only explicit in the theoretical concept and convenient in application but also reflects the time-varying characteristic of additional EDR, which possesses the value in practical engineering.


2003 ◽  
Vol 9 (3-4) ◽  
pp. 361-386 ◽  
Author(s):  
V. J. Modi ◽  
A. Akinturk ◽  
W. Tse

Bluff structures in the form of tall buildings, smokestacks, control towers, bridges, etc., are susceptible to vortex resonance and galloping type of instabilities. One approach to vibration control of such systems is through energy dissipation using sloshing liquid dampers. In this paper we focus on enhancing the energy dissipation efficiency of a rectangular liquid damper through the introduction of two-dimensional obstacles as well as floating particles. The investigation has two phases. To begin with, a parametric free vibration study aimed at the optimization of the obstacle geometry is undertaken to arrive at configurations promising increased damping ratio and hence higher energy dissipation. The study is complemented by an extensive wind tunnel test program, which substantiates the effectiveness of this class of damper in suppressing both vortex resonance and galloping type of instabilities. Simplicity of design, ease of implementation, minimal maintenance, reliability as well as high efficiency make such liquid dampers quite attractive for real-life applications.


Author(s):  
Michael CH Yam ◽  
Ke Ke ◽  
Ping Zhang ◽  
Qingyang Zhao

A novel beam-to-column connection equipped with shape memory alloy (SMA) plates has been proposed to realize resilient performance under low-to-medium seismic actions. In this conference paper, the detailed 3D numerical technique calibrated by the previous paper is adopted to examine the hysteretic behavior of the novel connection. A parametric study covering a reasonable range of parameters including the thickness of the SMA plate, friction coefficient between SMA plate and beam flange and pre-load of the bolt was carried out and the influence of the parameters was characterized. In addition, the effect of the SMA Belleville washer on the connection performance was also studied. The results of the numerical study showed that the initial connection stiffness and the energy-dissipation capacity of the novel connection can be enhanced with the increase of the thickness of the SMA plate. In addition, the initial connection stiffness and energy-dissipation behavior of the novel connection can be improved by increasing the friction coefficient or pre-load of bolts, whereas the increased friction level could compromise the self-centering behavior of the connection. The hysteretic curves of the numerical models of the connection also implied that the SMA washers may contribute to optimizing the connection behavior by increasing the connection stiffness and energy-dissipation capacity without sacrificing the self-centering behavior.


Sign in / Sign up

Export Citation Format

Share Document