scholarly journals Contrast-Enhanced Ultrasound Evaluation of Mifepristone for Treatment of Low-Risk Cesarean Scar Pregnancy

2020 ◽  
Vol 2020 ◽  
pp. 1-6
Author(s):  
Xi Xiong ◽  
Chun-yan Gao ◽  
De-mei Ying ◽  
Ping Yan ◽  
Zhi-jia Zhang ◽  
...  

Purpose. The effect of mifepristone for treatment of low-risk cesarean scar pregnancy (CSP) was monitored by contrast-enhanced ultrasound (CEUS). Methods. Data were collected from 23 CSP patients with a 10-point risk score <5 (low-risk CSP) and from 23 intrauterine pregnancy (IUP) patients with a scar from a previous cesarean delivery. All patients were prescribed 75 mg mifepristone daily for 2 days and underwent transvaginal CEUS before and after administration of mifepristone. On the third day, uterine curettage was performed after transvaginal CEUS. Arrival time (AT), peak intensity (PI), and area under the curve (AUC) around the gestational sac were monitored by CEUS before and after application of mifepristone, and the rate of effective treatment was compared between the two patient groups. Results. No patients experienced side effects from either the CEUS procedure or the mifepristone treatment. Changes in AT, PI, and AUC index from before vs. after mifepristone treatment did not differ significantly between the two groups (all p values >0.05). There was also no significant difference in the rate of effective treatment between the two groups (95.65% in the CSP group vs. 100% in the IUP group; p > 0.05 ). Conclusions. Based on monitoring by CEUS, the effect of mifepristone in low-risk CSP was comparable to that in IUP.

2016 ◽  
Vol 2016 ◽  
pp. 1-5 ◽  
Author(s):  
Xi Xiong ◽  
Ping Yan ◽  
Chunyan Gao ◽  
Qiulei Sun ◽  
Fenglian Xu

Objective. To evaluate the value of contrast-enhanced ultrasound (CEUS) in the cesarean scar pregnancy (CSP).Methods. Clinical data from 92 patients with lower uterine segment pregnancy, who underwent conventional ultrasound and CEUS examination in the Department of Obstetrics and Gynecology, were collected by Xinqiao Hospital Third Military Medical University from March 2014 to March 2015. The parameters of ultrasound contrast time-intensity curve (TIC), including arrival time, time to peak, time from peak to one half, basic intensity, peak intensity, and wash-in slope, were analyzed.Results. Of the 92 cases of patients with pregnancy in the lower uterine segment, 52 cases were CSP, and 40 cases were intrauterine pregnancy. CEUS was significantly better than conventional ultrasound in terms of sensitivity, negative predictive value, Youden index, and diagnostic accuracy (P<0.05). There was no significant difference in specificity and positive predictive value (P>0.05).Conclusion. CEUS has a higher accuracy than conventional ultrasound in diagnosis of CSP.


Medicine ◽  
2019 ◽  
Vol 98 (44) ◽  
pp. e17741 ◽  
Author(s):  
Yun Wu ◽  
Liuying Zhou ◽  
Lin Chen ◽  
Qian Zhou ◽  
Tao Zeng

2020 ◽  
Vol 48 (12) ◽  
pp. 030006052098021
Author(s):  
Dongmei Liu ◽  
Xiaoning Gu ◽  
Fang Liu ◽  
Fuwen Shi ◽  
Min Yang

Objective The current study aimed to investigate the application of contrast-enhanced ultrasound (CEUS) in diagnosis and treatment of cesarean scar pregnancy (CSP). Methods A retrospective study was performed in 35 patients with clinically suspected CSP who requested termination of pregnancy and underwent contrast-enhanced ultrasound (CEUS). The patients were classified into two groups on the basis of whether they received uterine artery embolization (UAE). The CEUS characteristics of the two groups were reviewed. Results CEUS features of CSP were early enhancement of the cesarean scar and continuous infusion of contrast agent between the gestational sac and cesarean scar. Myometrial thickness in the cesarean scar was thinner in the UAE group than in the non-UAE group by CEUS and transvaginal ultrasound. Myometrial thickness measured by CEUS was thinner than that measured by transvaginal ultrasound in both groups. The parameters of the time-intensity curve in the UAE group were characterized by a faster arrival time, shorter time to peak, higher peak intensity, and greater enhancement rate compared with the non-UAE group. Conclusions CEUS may be a novel supplementary method to diagnose and assess CSP, and to help evaluate whether UAE is required.


Author(s):  
Dian Yuan Lu ◽  
Lan Liu ◽  
Li Shen ◽  
Jian Rong Cai ◽  
Li Xu ◽  
...  

OBJECTIVE: To investigate prostate cancer detection rate of different biopsy protocols in different PSA value groups in rural China. METHODS: A total of 186 patients underwent contrast-enhanced ultrasound (CEUS) in order to determine the puncture target prior to biopsy were enrolled in this retrospective study. All patients underwent 12-core SB combined with CEUS-TB. The biopsy results of different biopsy protocols were compared in patients with stratification by PSA value. RESULTS: Among the 186 patients underwent prostate biopsy, the histopathologic results revealed prostate cancer (PCa) in 117 cases (62.9%) and benign lesions in 69 cases (37.1%). The PCa detection rate between 8-core SB and 12-core SB showed no significant difference in PSA 4–10 ng/ml group, while the 12-core SB was significantly higher than CEUS-TB (44.9% versus 32.7% , P = 0.01). In PSA 10–20 ng/ml group, the significant difference was not seen between SB and CEUS-TB (50.0% versus 45.7% , P = 0.15). As for PSA greater than 20 ng/ml group, the PCa detection rate by SB was higher than CEUS-TB, but showed no statistically significance (79.1% versus 76.9% , P = 0.15). In the overall patients, the biopsy core positive rate of CEUS-TB was significantly higher than SB (97% versus 55.5% and 28.5% , P = 0.0001). CONCLUSION: The flexible use of SB combined with CEUS-TB can reduce the number of biopsy cores in higher PSA groups. It has clinical importance in the detection of PCa in different PSA value groups in rural China.


Author(s):  
Pēteris Priedītis ◽  
Maija Radziņa ◽  
Ilze Štrumfa ◽  
Zenons Narbuts ◽  
Arturs Ozoliņs ◽  
...  

Abstract The aim of the study was to investigate the diagnostic value of contrast-enhanced ultrasound (CEUS) in differentiating benign and malignant thyroid nodules. Thirty-five patients with morphologically proved thyroid nodules (17 malignant; 18 benign), underwent CEUS examination. Five enhancement patterns were evaluated: vascularisation, homogeneity, presence of peripheral rim type enhancement, wash-out rate of the contrast medium, and enhancement using microvascular imaging application. Time-intensity curves (TIC) were analysed in post-processing and defined as three types: slow versus rapid and stable versus rapid biphasic wash-out. Diagnostic value of the listed CEUS parameters was calculated. The results showed medium strength correlation between morphology (benign versus malignant nodule) and type of TIC curve rs = 0.38 (p = 0.021), as well as between mode of contrast enhancement rs = 0.39 (p = 0.022) and wash-out pattern rs =0.39 (p = 0.024). The overall pooled sensitivity of selected diagnostic parameters was 82%, specificity 57%, and accuracy 70%. Malignant nodules were characterised by iso- or hypovascular contrast enhancement and slow wash-out, while benign nodules showed hypervascular enhancement with rapid wash-out TIC curve and rim-like pattern. The CEUS patterns significantly differed between malignant and benign thyroid nodules with high diagnostic accuracy. Thus, CEUS has important clinical value as an additional tool to ultrasound and fine needle biopsy.


Author(s):  
Hui Huang ◽  
Si-min Ruan ◽  
Meng-fei Xian ◽  
Ming-de Li ◽  
Mei-qing Cheng ◽  
...  

Objectives: This study aimed to construct a prediction model based on contrast-enhanced ultrasound (CEUS) ultrasomics features and investigate its efficacy in predicting early recurrence (ER) of primary hepatocellular carcinoma (HCC) after resection or ablation. Methods: This study retrospectively included 215 patients with primary HCC, who were divided into a developmental cohort (n = 139) and a test cohort (n = 76). Four representative images—grayscale ultrasound, arterial phase, portal venous phase and delayed phase —were extracted from each CEUS video. Ultrasomics features were extracted from tumoral and peritumoral area inside the region of interest. Logistic-regression was used to establish models, including a tumoral model, a peritumoral model and a combined model with additional clinical risk factors. The performance of the three models in predicting recurrence within 2 years was verified. Results: The combined model performed best in predicting recurrence within 2 years, with an area under the curve (AUC) of 0.845, while the tumoral model had an AUC of 0.810 and the peritumoral model one of 0.808. For prediction of recurrence-free survival, the 2 year cumulative recurrence rate was significant higher in the high-risk group (76.5%) than in the low-risk group (9.5%; p < 0.0001). Conclusion: These CEUS ultrasomics models, especially the combined model, had good efficacy in predicting early recurrence of HCC. The combined model has potential for individual survival assessment for HCC patients undergoing resection or ablation. Advances in knowledge: CEUS ultrasomics had high sensitivity, specificity and PPV in diagnosing early recurrence of HCC, and high efficacy in predicting early recurrence of HCC (AUC > 0.8). The combined model performed better than the tumoral ultrasomics model and peritumoral ultrasomics model in predicting recurrence within 2 years. Recurrence was more likely to occur in the high-risk group than in the low-risk group, with 2-year cumulative recurrence rates respectively 76.5% and 9.5% (p < 0.0001).


2021 ◽  
Vol 11 ◽  
Author(s):  
Shi Yan Guo ◽  
Ping Zhou ◽  
Yan Zhang ◽  
Li Qing Jiang ◽  
Yong Feng Zhao

BackgroundWith the improvement of ultrasound imaging resolution and the application of various new technologies, the detection rate of thyroid nodules has increased greatly in recent years. However, there are still challenges in accurately diagnosing the nature of thyroid nodules. This study aimed to evaluate the clinical application value of the radiomics features extracted from B-mode ultrasound (B-US) images combined with contrast-enhanced ultrasound (CEUS) images in the differentiation of benign and malignant thyroid nodules by comparing the diagnostic performance of four logistic models.MethodsWe retrospectively collected and ultimately included B-US images and CEUS images of 123 nodules from 123 patients, and then extracted the corresponding radiomics features from these images respectively. Meanwhile, a senior radiologist combined the thyroid imaging reporting and data system (TI-RADS) and the enhancement pattern of the ultrasonography to make a graded diagnosis of the malignancy of these nodules. Next, based on these radiomics features and grades, logistic regression was used to help build the models (B-US radiomics model, CEUS radiomics model, B-US+CEUS radiomics model, and TI-RADS+CEUS model). Finally, the study assessed the diagnostic performance of these radiomics features with a comparison of the area under the curve (AUC) of the receiver operating characteristic curve of four logistic models for predicting the benignity or malignancy of thyroid nodules.ResultsThe AUC in the differential diagnosis of the nature of thyroid nodules was 0.791 for the B-US radiomics model, 0.766 for the CEUS radiomics model, 0.861 for the B-US+CEUS radiomics model, and 0.785 for the TI-RADS+CEUS model. Compared to the TI-RADS+CEUS model, there was no statistical significance observed in AUC between the B-US radiomics model, CEUS radiomics model, B-US+CEUS radiomics model, and TI-RADS+CEUS model (P&gt;0.05). However, a significant difference was observed between the single B-US radiomics model or CEUS radiomics model and B-US+CEUS radiomics model (P&lt;0.05).ConclusionIn our study, the B-US radiomics model, CEUS radiomics model, and B-US+CEUS radiomics model demonstrated similar performance with the TI-RADS+CEUS model of senior radiologists in diagnosing the benignity or malignancy of thyroid nodules, while the B-US+CEUS radiomics model showed better diagnostic performance than single B-US radiomics model or CEUS radiomics model. It was proved that B-US radiomics features and CEUS radiomics features are of high clinical value as the combination of the two had better diagnostic performance.


2014 ◽  
Vol 2014 ◽  
pp. 1-8 ◽  
Author(s):  
Claudio Bonifati ◽  
Fulvia Elia ◽  
Dario Graceffa ◽  
Fabrizio Ceralli ◽  
Elisa Maiani ◽  
...  

Background. We wanted to verify retrospectively the proportion of patients with psoriatic arthritis who were in remission after 1 year of continuous therapy with either etanercept or adalimumab. Remission was defined as the absence of both clinical and contrast-enhanced ultrasound (CEUS) findings suggestive of joint inflammation. Patients and Methods. The data of twenty-five patients with psoriatic arthritis were available for the clinical and CEUS evaluations before and after 1 year of continuous therapy with etanercept or adalimumab. The count of swollen (ACR66), tender (ACR68), and active inflamed joints (AJC) was used to measure the severity of joint involvement. PASI was used to score the severity of psoriasis. HAQ, DLQI, VAS pain, and VAS itching were administered to each patient before starting therapy and every 3 months, up to 1 year. Results. Eight (32%) out of twenty-five patients were in remission after 1 year of therapy with etanercept or adalimumab. A significant reduction of all clinical variables analysed was seen during the course of therapy. Conclusion. Although a significant proportion of patients achieved remission of arthritis after 1 year of effective anti-TNF therapy, the majority of them continued to have either clinical or CEUS findings suggestive of persistence of joint inflammation.


Sign in / Sign up

Export Citation Format

Share Document