scholarly journals The Effect of Translucency and Surface Treatment on the Flexural Strength of Aged Monolithic Zirconia

2021 ◽  
Vol 2021 ◽  
pp. 1-7
Author(s):  
Rashin Giti ◽  
Benika Abbasi

Aims. This in vitro study aimed to evaluate the effect of the degrees of translucency in different types of monolithic zirconia as well as the aging and surface treatment with airborne particle abrasion on the flexural strength of monolithic zirconia. Materials and Methods. Sixty bar-shaped specimens were fabricated from three different types of presintered monolithic zirconia (n = 20 per group) including low translucent (LT) (DD Bio ZW iso, high strength zirconia, Dental Direkt, Germany), high translucent (HT) (DD Bio ZX2 98, high translucent zirconia, Dental Direkt, Germany), and multilayered system (ML) (DD cubeX2®ML, multilayer, cubic zirconia system, Dental Direkt, Germany). Each monolithic zirconia group was equally subdivided according to be either air-abraded with 110 µm aluminium oxide particles or left untreated (control). After thermocycling, the flexural strength was measured by using a universal testing machine. Two-way ANOVA followed by Tukey’s post hoc and independent samples t-test were used for the statistical analyses (P < 0.05). Results. Surface treatment and types of zirconia were found to have a significant interaction (P = 0.010). Having controlled the effect of surface treatment, the flexural strength of HT and LT zirconia was found to be significantly higher than the ML zirconia system (P ≤ 0.001). Airborne particle abrasion could significantly decrease the flexural strength of monolithic zirconia only in ML zirconia (P = 0.002). Conclusions. Multilayered zirconia system had the lowest flexural strength among all groups. Moreover, the flexural strength of this system was attenuated by surface treatment with airborne particles abrasion.

2020 ◽  
pp. 67-70
Author(s):  
Garima Gothwal ◽  
Hemant Kumar Sharma ◽  
Kusum Singh ◽  
Richa Sengar

Aim: The tear strength of three different types of elastomeric impression materials was measured after disinfection and sterilization. Material and Method: Dumb-bell shaped Tear strength specimens were prepared according to ISO 34-1 standardization. Ninety samples were prepared followed by disinfection and sterilization and tested with trouser piece method on Instron universal testing machine at a speed of 10 mm/min. One-way ANOVA, followed by Tukey post hoc test was used for statistical analysis. Results: No signicant difference was found when AFFINIS, SPEEDEX and AQUASIL were compared individually. When materials were compared with each other signicant difference was present, highest AQUASIL while SPEEDEX and AFFINIS almost alike. Conclusion: It was concluded that tear strength of AQUASIL was the highest. Disinfection and autoclaving had no signicant inuence on the three materials and showed adequate tear strength.


2019 ◽  
Vol 22 (1) ◽  
pp. Process
Author(s):  
Shereen Ahmed Nossair ◽  
Tarek Salah ◽  
Kamal Khaled Ebeid

Objective: This study was designed to evaluate the biaxial flexural strength (BFS) of different types of unshaded and shaded monolithic zirconia. Material and Methods: 120 monolithic zirconia ceramic discs were fabricated. They were divided into twelve groups (n=10), Group 1; Bruxzir unshaded, Group 2; Bruxzir shaded A2, Group 3; Bruxzir anterior white, Group 4; Bruxzir anterior shade A2, Group 5; Prettau unshaded, Group 6; Prettau shaded with A2 coloring liquid, Group 7; Prettau anterior white, Group 8; Prettau anterior shaded with A2 coloring liquid, Group 9; Katana HT white, Group 10; Katana HT shade A2, Group 11; Katana ST white, Group 12; Katana ST shade A2. All discs were milled using a dental milling machine, and had final dimensions after sintering of 15 mm diameter and 1 mm thickness. BFS was tested using piston on three ball technique. Results:  One-way ANOVA revealed significant differences among the 12 groups. Tukey post-hoc tests revealed no significant differences between the groups 3, 4, ,7 ,8 11, and 12. However, they all had BFS values that are significantly lower than all other groups. Group 2 showed statistically significant higher BFS values when compared to group 3,4, 7, 8, 11, and 12 while it showed statistically significant lower values when compared to groups 1, 5, 6, 9, and 10. Conclusion: Increase in the yttria content in zirconia led to a decrease in its BFS. Shading of zirconia did not have a significant effect on the final strength of zirconia. KeywordsDental ceramics; Dental esthetics; Flexural strength; Shaded zirconia. 


Author(s):  
CHARANTEJA VEMAGIRI ◽  
Uloopi KS ◽  
Vinay Chandrappa ◽  
Anusha Ch

Background: A successful restorative material forms a better adhesion, resist the microleakage and releases fluoride. However, existing glass ionomer cements cannot be used as a posterior restorative material in stress bearing areas. A new ionomer called Zirconomer, zirconia reinforced glass ionomer claims to exhibit high physical and biological properties. Aim: To assess and compare the microleakage, compressive strength, flexural strength and fluoride release from zirconomer with ketac silver. Materials & Methods: On twenty caries free premolar teeth (10 per each group), a class v cavity was restored with zirconomer and ketac silver. The microleakage was assessed using dye penetration test and stereomicroscope. The compressive and flexural strengths of these materials were measured using Instron Universal testing machine. The amount of fluoride released from the modified ionomers at pH 5 and pH 7 was estimated using Orion fluoride specific electrode. The obtained data was then subjected to statistical analysis. Results: Data was analysed using paired t-test for intergroup comparisons and unpaired t-test for intragroup comparisons. The overall microleakage (0.5±0.48) of zirconomer was significantly less (p=0.000) compared to ketac silver (1.9±0.83). Zirconomer demonstrated a significant higher compressive strength (330.25±60.14), flexural strength (33.058±2.36) than ketac silver (p= 0.000). Zirconomer demonstrated high fluoride release from day 1 to day 7 at both pH 5 and pH 7. Conclusion: Zirconomer demonstrated better physical and biological properties compared with ketac silver.


Medicina ◽  
2019 ◽  
Vol 55 (11) ◽  
pp. 749 ◽  
Author(s):  
Satheesh B. Haralur ◽  
Noura Raqe S. Alqahtani ◽  
Fatimah Alhassan Mujayri

Background and aim: All-ceramic prosthesis is widely used in modern dental practice because of its improved physico-mechanical and optical properties. These restorations are exposed to coloring agents from various nutrition and beverages in the oral cavity. Long-term color stability is critical for the success of these restorative materials. The purpose of this in vitro study was to assess the effect of common beverages and mouthwash on the color stability of lithium disilicate (LD), monolithic zirconia (MZ) and bilayer zirconia (BZ) surfaces. Material and methods: Thirty disc-shaped specimens from each material were fabricated; each group was subdivided (n = 10) according to coffee, green tea and chlorhexidine immersion solutions. The baseline color of ceramic discs was recorded according to the CIE L*a*b* system with a portable spectrophotometer. The second measurement was recorded after 3000 thermocycling and immersion in coloring agents for 7 days. The mean color difference was calculated and data were compared with Kruskal-Wallis and Mann-Whitney post hoc tests (0.05). Results: ΔE values for LD with the immersion of coffee, tea, and Chlorhexidine gluconate (CHG) were 1.78, 2.241 and 1.58, respectively. Corresponding ΔE values for MZ were 5.60, 5.19, and 4.86; marginally higher than the clinically acceptable level of 3.5. Meanwhile, BZ showed better color stability compared to MZ with ΔE values of 4.22, 2.11 and 1.43. Conclusion: Among the ceramics evaluated, LD ceramic was found to be more color stable, while MZ ceramics displayed a higher susceptibility to discoloration. MZ and BZ ceramic colors were significantly altered with coffee immersion, while LD ceramics were more affected by green tea.


2015 ◽  
Vol 1 (3) ◽  
pp. 143
Author(s):  
Diatri Nari Ratih

Calcium hydroxide has been used extensively in endodontic treatments, for instance as an intra-canal dressing; however, the exposure of root canal dentin to calcium hydroxide may affect its flexural strength and could have important clinical implications for endodontic treatment. The purpose of this in vitro study was to investigate the influence of calcium hydroxide on the flexural strength of root canal dentin.Seventy-two extracted single-rooted human mandibular premolars were used in this study. Each tooth was instrumented using crown-down technique and was irrigated using sterile saline. The teeth were assigned into three groups of 24 each. The prepared root canal system of each tooth was filled with calcium hydroxide mixed with sterile saline (group 1), a calcium hydroxide commercially available product (UltraCal®) (group 2) or saline solution (group 3, as control). The apices and access opening were sealed using composite resin, and the teeth were immersed in artificial saliva. After 7, 14 and 30 days of immersion, the inner root canal dentin of 8 teeth respectively from each group were sectioned to create dentin bars (1 X 1 mm, with 7 mm in length). Each dentin bar then was subjected to a three-point bending flexural test using MTS (Universal Testing Machine). Data gathered were then analyzed using two-way ANOVA, followed by Tukey’s test with the level of significance of 95%. The results showed that exposure to calcium hydroxide either using calcium hydroxide mixed with sterile saline or UltraCal® for 14 and 30 days can reduce flexural strength of root canal dentin compared to control group (p<0.05). In contrast, after 7 days exposure, there was no significantly different of flexural strength between three groups (p>0.05).   It can be concluded that calcium hydroxide reduced the flexural strength of root canal dentin. The longer the exposure to calcium hydroxide would produce a greater effect on flexural strength of root canal dentin.   


Author(s):  
Anubhuti Bakshi ◽  
Rajat Dang

ABSTRACT Aim To evaluate surface hardness and dimensional accuracy of type IV dental stone after incorporation of disinfectants. Materials and methods A total of 100 specimens, 50 (40 mm⨯ 10 mm) disk shaped and 50 frustum cone shaped, were fab- ricated from type IV dental stone after incorporation of various disinfectants, namely glutaraldehyde (2%), iodophor (1.76%), chlorhexidine (2%), and sodium hypochlorite (1%), for evaluation of surface hardness and dimensional accuracy. Surface hardness was tested after 1- and 24-hour time interval using Rockwell hard- ness testing machine. Dimensional accuracy was measured using traveling microscope. Data obtained were compiled and analyzed statistically by using analysis of variance and post hoc test. Results Results showed significant decrease in surface hard- ness of samples incorporated with disinfectants at 1 hour as compared with control (distilled water). Surface hardness of all the samples increased with time and was almost equal to control group at 24-hour interval, with iodophor showing the maximum value in comparison with the other disinfectants used. When dimensional accuracy of all the groups was compared, iodophor and sodium hypochlorite were found to cause negative alterations. Conclusion Within the limitations of this in vitro study, it was concluded that incorporation of disinfectants in die stone during mixing did not affect the hardness value at 24-hour interval. Dimensional accuracy was altered by iodophor and sodium hypochlorite, but remained unaffected by chlorhexidine and glutaraldehyde. How to cite this article Bakshi A, Dang R. Effect of Incorpo- ration of Disinfectants on Surface Hardness and Dimensional Accuracy of Die Stone An in vitro Study. Int J Prosthodont Restor Dent 2017;7(3):86-91.


2021 ◽  
Author(s):  
Ladan Ranjbar Omrani ◽  
Saba Tohidkhah ◽  
Elham Ahmadi ◽  
Mahdi Abbasi ◽  
Reza Morvaridi Farimani

Abstract Background: The aim of the current study was to evaluate and compare the influence of Dycal, Lime-lite, Theracal LC, Biodentine, Resin-modified glass ionomer cement (RMGIC), and Activa Bioactive as the pulp capping material on the shear bond strength of resin composite to dentin.Methods: A total of 70 extracted caries-free molars were randomly assigned to seven groups. Six test groups were covered with various protective liners: Dycal (GD), Theracal LC (GT), lime-lite (GL), Activa Bioactive (GA), Biodentine (GB), RMGIC (GR). The control group (GC)received no liner pretreatment. Each sample was bonded to resin composite using the total-etch tetric N bond adhesive. The samples were then tested for shear bond strength using the universal testing machine at a cross-head speed of 1 mm/min until bond failure occurred. The data were analyzed using the one-way ANOVA test followed by the Tamhane post-hoc test for pairwise comparisons of the groupsResults: Independent of the type of the applied liner, all groups exhibited inferior SBS to dentine compared to the control group. GT and GR showed significantly higher shear bond strength than GB and GD, which showed the lowest shear bond strength. GL and GA also had significantly lower SBS results than GT. The mode of fracture was predominantly cohesive in GD, GB, and GT and adhesive in GA.Conclusion: This present study concludes that the bond strength of resin-composite to dentine can be affected differently using various types of liners.


Sign in / Sign up

Export Citation Format

Share Document