Modular endoprosthetic implant for maximizing residual limb length: A case report

2018 ◽  
Vol 43 (1) ◽  
pp. 123-126
Author(s):  
Marc El Beaino ◽  
Jiayong Liu ◽  
Patrick P Lin

Background: For transfemoral amputations, the residual femoral length is critically important to prosthetic function. The aim of this report is to describe a novel method of extending femoral length and to assess its stability over time. Case Description and Methods: A 57-year-old woman with recurrent parosteal osteosarcoma was treated with above-knee amputation. A portion of the distal femoral endoprosthesis, which included uncemented fixation with a Compress® stem, was retained in an effort to extend the short femoral remnant and maximize stump length. Findings: At 3 years follow-up, the Compress stem remained well-fixed, and there was no soft tissue breakdown over the implant. The patient ambulated with a prosthetic limb and no external support. Outcomes and Conclusion: To the best of our knowledge, this is the first report of using the Compress device as a means to maintain stable fixation and extend residual femoral length following above-knee amputation. Clinical relevance Extension of residual bone length in amputated limbs can help improve prosthetic fitting and function. The Compress device may be useful in this application as a means of secure fixation for a modular metallic prosthesis.

2017 ◽  
Vol 16 (1) ◽  
Author(s):  
Breno Boueri Affonso ◽  
Joaquim Maurício da Motta Leal Filho ◽  
Rafael Noronha Cavalcante ◽  
Priscila Mina Falsarella ◽  
Francisco Leonardo Galastri ◽  
...  

ABSTRACT Preservation of the knee joint has enormous advantages in terms of mobility and rehabilitation of an amputee. Any cause of breakdown requiring revision to an above-knee amputation is a major setback because it reduces the patient’s rehabilitative potential. We report a case of intra-arterial thrombolysis use to save a below-knee amputation stump with acute ischemia. A 56-year-old man who sought the emergency department with 1-day history of acute pain on his right below-knee stump. The angiography confirmed popliteal artery occlusion. Pharmacomechanical thrombectomy, with Aspirex (rotational catheter to restore blood flow in occluded vessel, by removing occlusion material from the vessel) and recombinant tissue plasminogen activator, was performed. After 9 years of follow-up the patient remained asymptomatic, capable of independent ambulation with prosthetic limb. Intra-arterial fibrinolysis seems to be a safe and effective treatment for cases of acutely ischemic amputation stump.


GeroPsych ◽  
2012 ◽  
Vol 25 (4) ◽  
pp. 235-245 ◽  
Author(s):  
Katja Franke ◽  
Christian Gaser

We recently proposed a novel method that aggregates the multidimensional aging pattern across the brain to a single value. This method proved to provide stable and reliable estimates of brain aging – even across different scanners. While investigating longitudinal changes in BrainAGE in about 400 elderly subjects, we discovered that patients with Alzheimer’s disease and subjects who had converted to AD within 3 years showed accelerated brain atrophy by +6 years at baseline. An additional increase in BrainAGE accumulated to a score of about +9 years during follow-up. Accelerated brain aging was related to prospective cognitive decline and disease severity. In conclusion, the BrainAGE framework indicates discrepancies in brain aging and could thus serve as an indicator for cognitive functioning in the future.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
P Philabout ◽  
L Soulat-Dufour ◽  
I Benhamou-Tarallo ◽  
S Lang ◽  
S Ederhy ◽  
...  

Abstract Background Few studies have assessed the evolution of cardiac chambers deformation imaging in patients with atrial fibrillation (AF) according to cardiac rhythm outcome. Purpose To evaluate cardiac chamber deformation imaging in patients admitted for AF and the evolution at 6-month follow-up (M6). Methods In forty-one consecutive patients hospitalised for AF two-dimensional transthoracic echocardiography was performed at admission (M0) and after six months (M6) of follow up. In addition to the usual parameters of chamber size and function, chamber deformation imaging was obtained including global left atrium (LA) and right atrium (RA) reservoir strain, global left ventricular (LV) and right ventricular (RV) free wall longitudinal strain. Patients were divided into three groups according to their cardiac rhythm at M0 and M6: AF at M0 and sinus rhythm (SR) at M6 (AF-SR) (n=23), AF at M0 and AF at M6 (AF-AF) (n=11), SR at M0 (spontaneous conversion before the first echocardiography exam) and SR in M6 (SR-SR) (n=7) Results In comparison with SR patients (n=7), at M0, AF patients (n=34)) had lower global LA reservoir strain (+5.2 (+0.4 to 12.8) versus +33.2 (+27.0 to +51.5)%; p<0.001), lower global RA reservoir strain (+8.6 (−5.4 to 11.6) versus +24.3 (+12.3 to +44.9)%; p<0.001), lower global LV longitudinal strain (respectively −12.8 (−15.2 to −10.4) versus −19.1 (−21.8 to −18.3)%; p<0.001) and lower global RV longitudinal strain (respectively −14.2 (−17.3 to −10.7) versus −23.8 (−31.1 to −16.2)%; p=0.001). When compared with the AF-SR group at M0 the AF-AF group had no significant differences with regard to global LA and RA reservoir strain, global LV and RV longitudinal strain (Table). Between M0 and M6 there was a significant improvement in global longitudinal strain of the four chambers in the AF-SR group whereas no improvements were noted in the AF-AF and SR-SR group (Figure). Conclusion Initial atrial and ventricular deformations were not associated with rhythm outcome at six-month follow up in AF. The improvement in strain in all four chambers strain suggests global reverse remodelling all cardiac cavities with the restoration of sinus rhythm. Evolution of strain between M0 and M6 Funding Acknowledgement Type of funding source: None


2021 ◽  
Vol 80 (Suppl 1) ◽  
pp. 491.2-491
Author(s):  
M. Tada ◽  
Y. Yamada ◽  
K. Mandai ◽  
N. Hidaka

Background:We previously reported that the prevalence of sarcopenia was 28% in patients with rheumatoid arthritis (RA) in a cohort study 1. RA patients have a high risk of falls and fractures 2. However, the predictors of falls and fractures in RA patients are not known.Objectives:Whether evaluation of muscle mass and function at baseline could predict falls and fractures during four-year follow-up was investigated.Methods:The four-year follow-up data from a prospective, observational study (CHIKARA study: Correlation researcH of sarcopenIa, sKeletal muscle and disease Activity in Rheumatoid Arthritis) were used. Muscle mass was measured by a body impedance analyzer, and leg muscle mass was calculated. The leg muscle score (max: 100, min: 0) reflected the ratio of leg muscle mass to overall weight. Grip strength as an indicator of muscle function was evaluated using a digital, hand-held, isokinetic dynamometer. The correlations between muscle mass or function and falls or fractures were analyzed by survival rates and Cox hazard ratios. Leg muscle mass and grip strength were investigated by receiver operating characteristic (ROC) curve analysis for correlations with falls or fractures.Results:A total of 100 RA patients (female: 78%, mean age: 66.1 years) were enrolled; 35 patients had falls, and 19 patients had fractures during the four-year follow-up. The leg muscle score, grip strength, age, and fractures at baseline were significantly correlated with falls. The cut-off values of the leg muscle score and grip strength were calculated to be 84.5 points (sensitivity: 0.79, specificity: 0.43) and 15.9 kg (sensitivity: 0.56, specificity: 0.70), respectively, by ROC curve analysis. The patients were divided into four groups by their leg muscle scores and grip strength; the numbers of falls and fractures are shown in Table 1 for each group. The fall-free survival rate was significantly lower in the group with low leg muscle score and low grip strength (35.3%) than in the other groups (P=0.002) (Figure 1). The hazard ratio for the both low group was significantly increased, 3.6-fold (95%CI: 1.1-11.5), compared to that in the both high group.Table 1.Numbers of falls and fractures by category of leg muscle score and grip strengthLG + GS+(n=34)LG - GS+(n=12)LG + GS-(n=37)LG - GS-(n=17)P value*Falls, N6515110.010Fractures, N34660.072LG+: leg muscle score >84.5 points, GS+: grip strength >15.9kg, LG-: leg muscle score ≤84.5 points, GS+: grip strength ≤15.9kg*: compared in four groups by Kruskal-Walls test.Figure 1.Fall-free survival rate in the four groupsConclusion:RA patients with both low leg muscle score and low grip strength at baseline were at high risk for falls during the four-year follow-up period. Evaluation of muscle mass and function can predict falls in RA patients.References:[1]Tada, M., Yamada, Y., Mandai, K. & Hidaka, N. Matrix metalloprotease 3 is associated with sarcopenia in rheumatoid arthritis - results from the CHIKARA study. Int J Rheum Dis21, 1962-1969, doi:10.1111/1756-185X.13335 (2018).[2]van Staa, T. P., Geusens, P., Bijlsma, J. W., Leufkens, H. G. & Cooper, C. Clinical assessment of the long-term risk of fracture in patients with rheumatoid arthritis. Arthritis Rheum54, 3104-3112, doi:10.1002/art.22117 (2006).Disclosure of Interests:None declared


2017 ◽  
Vol 06 (04) ◽  
pp. 329-333 ◽  
Author(s):  
Sidney Jacoby ◽  
Paul Marchetto ◽  
Peter DeLuca ◽  
Randall Culp ◽  
Michael Gaspar

Abstract Background No consensus treatment option for focal osteochondral defects of the proximal lunate exist in the literature. Surgical management has thus far been limited to salvage procedures such as proximal row carpectomy and partial arthrodesis. Case Description We report our experience using the osteochondral autograft transplantation surgery (OATS) procedure in two young, active patients with focal osteochondral defects of the proximal lunate. At mean follow-up of 6 years, sustained improvements in pain, motion, and function were observed. Both patients reported high levels of satisfaction and neither experienced any complications. Literature Review To our knowledge, this is the first report describing the use of OATS to treat proximal lunate defects. Clinical Relevance OATS is a valuable surgical option for treating focal chondral defects of the proximal lunate, with positive outcomes at greater than 5 years postoperatively. This may be an especially useful technique for younger, active patients, and those wishing to maintain maximum functionality.


Author(s):  
Margit V. Szabari ◽  
Jozsef Tolnai ◽  
Balazs Maar ◽  
Harikrishnan Parameswaran ◽  
Elizabeth Bartolak-Suki ◽  
...  

2021 ◽  
pp. 147332502198942
Author(s):  
Madeleine Wirzén ◽  
Asta Čekaitė

The assessment of prospective adoptive parents is a complex task for professional social workers. In this study, we examine the structure and function of professional social workers’ follow-up questions in assessment talk with adoption applicants. The analysis shows that adoption assessment through interviews involved a delicate and complex task that was accomplished by using a particular genre of institutional talk. This both invited the applicants’ extended and ‘open-ended’ responses and steered these responses and their development towards the institutionally relevant topics. Detailed interaction analysis demonstrates that social workers used a broad range of question types to steer and guide applicants’ responses, organising talk about specific assessment topics. On the basis of initial open-ended topic initiations and applicants’ responses, the social workers steered topic development by using follow-up moves such as polar questions and clarifying questions that asked for specification, challenged applicants’ ideas, confirmed their knowledge and encouraged self-reflection. These follow-up moves allowed social workers to achieve the progression of talk into relevant areas of investigation and constituted a central and characteristic feature of assessment interviews. We suggest that they allow social workers to accomplish two hybrid institutional goals: i) the assessment of applicants’ suitability and ii) applicants’ preparation for future parenthood.


PEDIATRICS ◽  
1986 ◽  
Vol 77 (3) ◽  
pp. 390-395
Author(s):  
Ch. Maayan ◽  
C. Springer ◽  
Y. Armon ◽  
E. Bar-Yishay ◽  
V. Shapira ◽  
...  

Two siblings, a 14.5-year-old boy and his 11.5-year-old sister, with congenital nemaline myopathy presented with severe respiratory failure and, in the case of the older patient, with cor pulmonale and systemic hypertension. The children were treated initially by continuous mechanical ventilation, but after a few weeks they only required ventilation at night. At the start of treatment, both were found to have a decreased ventilatory response to CO2 which apparently improved during 4 to 5 years of follow-up treatment. It has not been possible to wean them from nocturnal mechanical ventilation, but during the daytime they attend school and function almost normally. It is postulated that respiratory failure in nemaline myopathy may not be related to the severity of the muscle weakness but may result from a disturbance of the feedback required for normal control of breathing.


Author(s):  
Jesús Peláez Rico ◽  
Jorge Cortés-Bretón Brinkmann ◽  
María Carrión Martín ◽  
Mabel Albanchez González ◽  
Celia Tobar Arribas ◽  
...  

The aim of this clinical report is to describe a maxillary full-arch implant supported restoration with immediate loading performed by means of an entirely digital workflow with photogrammetric system and intraoral scanning. A female patient with an edentulous maxillary arch attended the dental clinic seeking a maxillary fixed restoration. After treatment planning, six implants were placed using a surgical splint fabricated digitally by intraoral scanning of her previous removable prosthesis. Multi-unit abutments were fitted and two digital impressions were taken, one with a photogrammetric system for determining implant positions, and the other with an intraoral scanner for soft tissue registration. The acrylic resin structure of the immediate prosthesis was milled and placed within 8 hours of implant surgery. This provisional structure fitted correctly and provided adequate esthetics and function. Radiographic and clinical follow-up after 24 months observed adequate implant evolution.


Sign in / Sign up

Export Citation Format

Share Document