Macro-strain based deflection and neutral axis position monitoring of reinforced concrete beams during corrosion

2022 ◽  
pp. 136943322110737
Author(s):  
Nariman Fouad ◽  
Mohamed A Saifeldeen

This article proposes a new technique of monitoring neutral axis positions and deflection of Reinforced Concrete (RC) beam during corrosion of steel reinforcement using macro-strain measurements of distributed long-gauge sensors. A different group of distributed long-gauge Packaged Carbon Fiber Line (PCFL) sensors with self-compensation and effective packaging system is installed on the compression and tension fibers of the concrete surface and steel reinforcements of RC beam to verify the proposed method experimentally. An accelerated corrosion method utilizing a salt solution and the constant current was used to achieve the required corrosion levels. The estimated deflection measured by the developed method is compared with the results using Linear Variable Displacement Transducer (LVDTs). It has been demonstrated that long-gauge PCFL sensors could provide the same accuracy. The distributed measured strains were utilized to evaluate the deterioration of the structure’s health with the advance of corrosion. Based on corrosion monitoring experimental results, it can be confirmed that using distributed PCFL sensors mounted on steel reinforcements or concrete surface, the locations and progress of the damage with corrosion time can be detected effectively. The maximum error in the estimated deflection from PCFL sensors mounted on the concrete surface compared to the LVDTs before the onset and after 24 h of accelerated corrosion was 0.5% and 2.5%, respectively.

2012 ◽  
Vol 535-537 ◽  
pp. 1803-1806
Author(s):  
Shun Bo Zhao ◽  
Peng Bing Hou ◽  
Fu Lai Qu

An experimental study was carried out to examine the non-uniform corrosion of plain steel bars in reinforced concrete beams partially placed in 5% sodium chloride solution under conditions of accelerated corrosion. 4 reinforced concrete beams with different concrete strength were made. The crack distributions of the beams due to pre-loads and expansion of corrosion product, and the sectional corrosion characteristics of plain steel bars are described in detail. The sectional area loss relating to mass loss and change along pure bending length of the beams are discussed. These can be used as the basis of test for further studies to build the numerical models of serviceability of corroded reinforced concrete beams.


2018 ◽  
Vol 149 ◽  
pp. 01022 ◽  
Author(s):  
Khadra Bendjillali ◽  
Mohamed Chemrouk

The valorisation of industrial waste in the field of construction became a very interesting axis of research from scientific, economic and environmental point of view. We have conducted this work to study the effect of the addition of polypropylene fibres waste on the mechanical behaviour of reinforced concrete beams subjected to a simple flexural loading, with and without transversal reinforcement. The used fibres are coming from the waste of the fabrication of domestic brushes and sweeps; they have an average diameter of 0.47 mm and a length between 40 and 60 mm. Two weight dosages of fibres are used, 0.25 and 0.5 %. The experimental results showed that the incorporation of polypropylene fibres waste into the concrete affects negatively its workability, but its flexural and compressive strength are improved. The fibers have presented a significant contribution on the shear behavior and the cracking of beams, particularly in absence of transversal bars. The waste used in this work as fibrous reinforcement has not only increased the ductility of reinforced concrete beams, but it have also provided a perfect cracking distribution on the concrete surface and it has participated in a considerable way in the reduction of cracks number and dimensions, which allows to ensure the material durability and then the structure longevity. The reinforcement of concrete beams with 0.5 % of polypropylene fibers waste with a minimal steel bars can ensure an excellent mechanical behavior in shear, as in flexion.


2010 ◽  
Vol 37 (8) ◽  
pp. 1045-1056 ◽  
Author(s):  
Christopher Suffern ◽  
Ahmed El-Sayed ◽  
Khaled Soudki

This paper reports experimental data on the structural performance of disturbed regions in reinforced concrete beams with corrosion damage to the embedded steel stirrups. A total of 15 reinforced concrete beams were constructed and tested. The test beams were 350 mm deep, 125 mm wide, and 1850 mm long. The beams were tested in three-point bending under a simply supported span of 1500 mm. Nine beams had the embedded stirrups subjected to accelerated corrosion. The test variables were the corrosion damage level and the shear span-to-depth ratio. The test results indicated that the corroded beams exhibited reduced shear strength in comparison to the uncorroded control specimens. The shear strength reduction was up to 53%. Furthermore, the reduction in shear strength due to the corrosion was found to be greater at smaller shear span-to-depth ratios.


Reinforced concrete structures are subjected to deterioration due to many factors such as corrosion of reinforcing steel. Ultimate strengths of structural elements can be greatly affected by these deteriorating factors. There are numerous methods and techniques used to protect these structural elements. The mortar layer (Plastering) is considered the first defense line against all the deteriorating factors. The main goal of this research is to investigate to what extent the plastering layer can protect reinforced concrete beams against corrosion. The aim of the experimental program is to study the effect of plastering layer on corrosion resistance of reinforced concrete beams. Four reinforced concrete beams (1002001100 mms) and four Lollypop specimens (cylinders 100200 mms) were tested and described as follows: • A beam and a lollypop specimen without any plastering layer (control). • A beam and a lollypop specimen with traditional plastering layer (cement + sand + water). • A beam and a lollypop specimen with modified plastering (traditional plastering + waterproof admixtures). • A beam and a lollypop specimen with painted and modified plastering layer (traditional plastering + waterproof admixtures + external waterproof paint). These eight specimens were subjected to corrosion using accelerated corrosion technique, after that the four beams were tested in flexure under three point load arrangement while the four lollypops were used to calculate the total mass loss due to accelerated corrosion. The test results were used to figure out the effect of plastering layer on corrosion resistance of RC beams.


Structures ◽  
2019 ◽  
Vol 19 ◽  
pp. 394-410 ◽  
Author(s):  
Mohammed Haloob Al-Majidi ◽  
Andreas P. Lampropoulos ◽  
Andrew B. Cundy ◽  
Ourania T. Tsioulou ◽  
Salam Alrekabi

2011 ◽  
Vol 255-260 ◽  
pp. 54-58 ◽  
Author(s):  
Zhen Hua Ren ◽  
Xian Tao Zeng

Rehabilitation of existing structures with fiber reinforced plastics (FRP) has been growing in popularity because they offer superior performance in terms of resistance to corrosion and high stiffness-to-weight ratio. This paper presents strain coordination results of (two groups)15 reinforced concrete beams strengthened with different methods including external-bonded and near-surface mounted carbon FRP strip in order to investigate the strain coordination of CFRP and steel rebar of RC beam. Because there is relative slipping between RC beam and CFRP, the strain of CFRP and steel rebar of RC beam satisfies the quasi-plane-hypothesis, that is, the strain of longitudinal fiber that parallels to the neutral axis of plated beam within the scope of effective height (h0) of the cross section is in direct proportion to the distance from the fiber to the neutral axis, the strain of FRP and steel rebar satisfies the equation: , the value of is equal to 1.1~1.3 according to the test results.


2013 ◽  
Vol 535-536 ◽  
pp. 205-208
Author(s):  
Zheng Wei Li ◽  
Pei Yan Huang ◽  
Hao Zhou

Fatigue behavior of reinforced concrete (RC) beam can be improved by externally bonded fiber reinforced polymer (FRP). However, propagation behavior of a crack on the RC beam will have serious effect on the fatigue life of the beam strengthened with FRP. In this paper, a finite element (FE) procedure was developed to analysis the stress intensity factor (SIF) of the main crack and an experimental study was conducted to investigate the propagation rate of the main crack of the RC beam strengthened with carbon fiber laminate (CFL) under cyclic bending load. The FE analysis results show that the SIF near the main crack tip increases at the beginning and then decreases with the fatigue crack propagation. When relative crack length α is equal to 0.3, the SIF is maximum. When α approaches 0.75, the SIF approaches zero. A total of 3 RC beams strengthened with CFL were tested. The experimental results show that it is possible to divide the process of the crack propagation into three distinct phases, including crack initiation and then quickly propagation, stable propagation and then rest and unstable propagation. A semi-empirical equation based on the Paris Law was developed to predict the crack propagation rate.


2014 ◽  
Vol 567 ◽  
pp. 399-404 ◽  
Author(s):  
Md Ashraful Alam ◽  
Ali Sami Abdul Jabbar ◽  
Mohd Zamin Jumaat ◽  
Kamal Nasharuddin Mustapha

Repair of reinforced concrete beam with externally bonded steel plate or fibre reinforced polymer (FRP) laminate is becoming both environmentally and economically preferable rather than replacement of deficient beam. The well known advantages of external reinforcement over other methods include; low cost, ease of maintenance and the ability to strengthen part of the structure while it is still in use. The disadvantage of this method, however, is the premature debonding of the externally bonded strips which is brittle and undesired mode of failure. It is also known that debonding of the externally bonded steel plates prevents the reinforced concrete (RC) beam from reaching its full strengthening capacity. The aim of this study was to increase the scientific understanding on the behaviour of damaged reinforced concrete beams strengthened and/or retrofitted for shear using vertical steel plate fixed with adhesive and steel connectors to eliminate or delay debonding failure. Four reinforced concrete beam specimens were prepared to investigate the effects of connectors in preventing or delaying premature debonding of shear strips to restore the capacities of fully damaged beams. Three damaged beams have been repaired and strengthened with steel plates and loaded monotonically up to the maximum load capacities in order to define load–deflection relationship. It is concluded that the repairing of severely shear-damaged RC beams with steel plates by using steel and adhesive connectors can fully restore the original shear capacities of the beams.


Sign in / Sign up

Export Citation Format

Share Document