scholarly journals Inflammation and infiltration: can the radiologist draw a line? MRI versus CT to accurately assess medullary involvement in parosteal osteosarcoma

2020 ◽  
Vol 35 (1_suppl) ◽  
pp. 31-36 ◽  
Author(s):  
Maria Pilar Aparisi Gómez ◽  
Alberto Righi ◽  
Costantino Errani ◽  
Giancarlo Facchini ◽  
Marco Gambarotti ◽  
...  

Cancer causes inflammation as it progresses through healthy tissue. The differentiation of tumoral growth from the surrounding inflammatory change is paramount in planning surgeries seeking to preserve function. This retrospective study aims at illustrating how a careful use of imaging (computed tomography (CT)/magnetic resonance imaging (MRI)) can help to draw the line between infiltration and inflammation. Out of 72 cases of parosteal osteosarcoma in our institution we selected 22 which had pretreatment imaging, and out of those, 14 that had both MRI and CT. Using Fisher’s exact test, we evaluated the performance of each technique on accurately diagnosing medullary tumor infiltration, using histological analysis as a gold standard. All cases (14/14) demonstrated medullary abnormality on MRI, but only 6/14 (42.9%) demonstrated abnormality on CT. The 8/14 cases with MRI abnormality but no CT abnormality (57.1%) showed inflammation with no tumoral cells present on histological analysis. In the cases where the two examinations showed medullary abnormality (6/14) histology demonstrated tumoral infiltration. MRI demonstrated high sensitivity and negative predictive value, but low specificity and low positive predictive value and accuracy (P=1). CT demonstrated high sensitivity, specificity, high positive and negative predictive values and accuracy (P = 0.000333). MRI is highly sensitive for the detection of medullary abnormality but lacks specificity for tumor invasion. Correlation with CT is recommended in all cases of positive MR to add specificity for tumors. The adequate use of the two imaging methods allows to differentiate between inflammatory change and tumoral infiltration in POS, relevant for surgical planning.

2021 ◽  
Vol 108 (Supplement_7) ◽  
Author(s):  
Nixon Phua Cher Yang ◽  
Muhammad Adeel Javed Butt ◽  
Parmvir Singh Nijjar ◽  
Saung Phyu ◽  
Musa Barkeji

Abstract Aims Nipple discharge is a presentation commonly seen at breast clinics. It is conventionally evaluated with physical examination and sonography( or mammography). The aim of this study is to investigate the diagnostic value of magnetic resonance imaging (MRI) as an additional imaging tool in the evaluation of potential malignancy in patients presented with nipple discharge. Methods A retrospective evaluation of 85 patients with nipple discharge who underwent breast ultrasound (USS) and MRI between 04/06/2008 and 25/10/2019 was conducted. Clinical notes, radiographic reports and biopsy results were reviewed. Sensitivity, specificity, positive predictive value and negative predictive value of USS and MRI were calculated. Results Out of the 85 patients (all female; mean age 45.33 +/- 12.93 years old) with nipple discharge, 11 were found to have biopsy-proven malignancy (invasive ductal carcinoma/ ductal carcinoma in situ; 12.94% risk). USS failed to identify seven malignancies (27.27% sensitivity) while MRI missed three malignancies (72.72% sensitivity). USS falsely identified four malignancies from 74 patients with no malignancy (94.59% specificity) while MRI only falsely identified one case (98.65% specificity). For patients with negative USS results (U1/U2/U3) or negative MRI results (BI-RADS category 1,2 or 3), the negative predictive values of USS is 89.74% while that of MRI is 96.05%. The positive predictive values of USS and MRI are 42.86% and 88.88% respectively. Conclusion Compared to USS, MRI has a higher sensitivity, specificity, positive predictive value and predictive value. It will be a valuable addition to the standard nipple discharge evaluation workup to help rule out malignancy.


2017 ◽  
Vol 68 (2) ◽  
pp. 116-121 ◽  
Author(s):  
Sharon E. Clarke ◽  
Dipan Mistry ◽  
Talal AlThubaiti ◽  
M. Naeem Khan ◽  
David Morris ◽  
...  

Purpose The purpose of this study was to evaluate the sensitivity, specificity, and positive and negative predictive values of the diffusion-weighted periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique in the detection of cholesteatoma at our institution with surgical confirmation in all cases. Methods A retrospective review of 21 consecutive patients who underwent diffusion-weighted PROPELLER magnetic resonance imaging (MRI) on a 1.5T MRI scanner prior to primary or revision/second-look surgery for suspected cholesteatoma from 2009-2012 was performed. Results Diffusion-weighted PROPELLER had a sensitivity of 75%, specificity of 60%, positive predictive value of 86%, and negative predictive value of 43%. In the 15 patients for whom the presence or absence of cholesteatoma was correctly predicted, there were 2 cases where the reported locations of diffusion restriction did not correspond to the location of the cholesteatoma observed at surgery. Conclusion On the basis of our retrospective study, we conclude that diffusion-weighted PROPELLER MRI is not sufficiently accurate to replace second look surgery at our institution.


2019 ◽  
Vol 9 (3-4) ◽  
pp. 155-162
Author(s):  
Boonsak Hanterdsith

Although the arcus corneae (AC) has long been used as an age indicator for forensic purposes, its diagnostic value has not been evaluated. To evaluate the AC as a predictor of chronological age, the author has studied the correlation of AC with respect to age of the deceased. A cross-sectional study was conducted of 342 Thai corpses at the Maharat Nakhon Ratchasima Hospital, Thailand. AC was graded into three levels: no AC, incomplete ring, and complete ring. One-way analysis of variance, chi-square test, binomial logistic regression, sensitivity, specificity, predictive values, and likelihood ratios were used for analysis. The Cohen’s kappa was used to determine the intraobserver and interobserver reliability. The prevalence of AC and the probability of complete AC were significant higher in corpses aged 60 years and above than in those under 60 years. Consequently, this study confirmed that the prevalence of AC was significantly correlated with the age of Thai individuals. If the complete AC is used as an indicator of age of 60 years and above, complete AC has high sensitivity (92.56%) but low specificity (72.85%), low positive predictive value (65.12%), but high negative predictive value (94.71%). For diagnostic value, the presence of AC can be used for age screening but not for absolute confirmation. The absence of AC indicates young age, incomplete AC indicates middle age, and complete AC indicates old age. The high intraobserver and interobserver reliability provides assurance of the value of AC as a means to estimate personal age.


Author(s):  
Gerald J. Kost

ABSTRACT Context. Coronavirus infectious disease-19 (COVID-19) diagnostics require understanding of how predictive values depend on sensitivity, specificity, and especially, low prevalence. Clear expectations, high sensitivity and specificity, and manufacturer disclosure will facilitate excellence of tests. Objectives. To derive mathematical equations for designing and interpreting COVID-19 tests, assess Food and Drug Administration (FDA) Emergency Use Authorization and Health Canada minimum requirements, establish sensitivity and specificity tiers, and enhance clinical performance in low prevalence settings. Design. PubMed and other sources generated articles on COVID-19 testing and prevalence. EndNote X9.1 consolidated references. Mathematica and open access software helped prove equations, perform recursive calculations, graph multivariate relationships, and visualize patterns, including a new relationship, predictive value geometric mean-squared. Results. Derived equations were used to illustrate shortcomings of COVID-19 diagnostics in low prevalence. Visual logistics helped establish sensitivity/specificity tiers. FDA/Canada's 90% sensitivity, 95% specificity minimum requirements generate excessive false positives at low prevalence. False positives exceed true positives at <5.3% prevalence, or if sensitivity is improved to 100% and specificity to 98%, at <2% prevalence. Recursive testing improves predictive value. Three tiers emerged from these results. With 100% sensitivity, physicians can select desired predictive values, then input local prevalence, to determine suitable specificity. Conclusions. Understanding low prevalence impact will help healthcare providers meet COVID-19 needs for effective testing. Laypersons should receive clinical performance disclosure when submitting specimens. Home testing needs to meet the same high standards as other tests. In the long run, it will be more cost-effective to improve COVID-19 POC tests rather than repeat testing multiple times.


2018 ◽  
Vol 1 ◽  
pp. 9
Author(s):  
Harshad Arvind Vanjare ◽  
Jyoti Panwar

Objective The objective of the study was to assess the accuracy of ultrasound examination for the diagnosis of rotator cuff tear and tendinosis performed by a short experienced operator, compared to magnetic resonance imaging (MRI) results. Method A total of 70 subjects suspected to have rotator cuff tear or tendinosis and planned for shoulder MRI were included in the study. Shoulder ultrasound was performed either before or after the MRI scan on the same day. Ultrasound operator had a short experience in performing an ultrasound of the shoulder. Ultrasound findings were correlated to MRI findings. Results Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for the diagnosis of tendinosis were 58%, 84%, 63%, 80%, and 75%, respectively, and it was 68%, 91%, 73%, 88%, and 85%, respectively, for the diagnosis of rotator cuff tear. Conclusions Sensitivity for diagnosing rotator cuff tear or tendinosis was moderate but had a higher negative predictive value. Thus, the ultrasound operator with a short experience in performing shoulder ultrasound had moderate sensitivity in diagnosing tendinosis or tears; however, could exclude them with confidence.


2021 ◽  
pp. 095646242110222
Author(s):  
Thomas Juniper ◽  
Chris P Eades ◽  
Eliza Gil ◽  
Harriet Fodder ◽  
Killian Quinn ◽  
...  

Objectives: An elevated serum (1-3)-β-D-glucan (BDG) concentration has high sensitivity for a diagnosis of Pneumocystis pneumonia (PCP) in people with HIV (PWH). At the current manufacturer-recommended positive threshold of 80 pg/mL (Fungitell), specificity for PCP is variable and other diagnostic tests are required. We evaluated the utility of serum BDG for diagnosis of suspected PCP in PWH at three inner-London hospitals to determine BDG concentrations for diagnosis and exclusion of PCP. Methods: From clinical case records, we abstracted demographic and clinical information and categorised patients as having confirmed or probable PCP, or an alternative diagnosis. We calculated sensitivity, specificity and positive predictive value (PPV) of serum BDG concentrations >400 pg/mL and negative predictive value (NPV) of BDG <80 pg/mL. Results: 76 patients were included; 29 had laboratory-confirmed PCP, 17 had probable PCP and 30 had an alternative diagnosis. Serum BDG >400 pg/mL had a sensitivity of 83%, specificity of 97% and PPV 97% for diagnosis of PCP; BDG <80 pg/mL had 100% NPV for exclusion of PCP. Conclusions: In PWH with suspected PCP, BDG <80 pg/mL excludes a diagnosis of PCP, whereas BDG concentrations >400 pg/mL effectively confirm the diagnosis. Values 80–400 pg/mL should prompt additional diagnostic tests.


Author(s):  
Ashoka Mahapatra ◽  
K Nikitha ◽  
Sutapa Rath ◽  
Bijayini Behera ◽  
Kavita Gupta

Abstract Background Spread of carbapenem-resistant Enterobacterales (CRE) is a significant concern in intensive care unit (ICU) settings. Approaches to routine screening for CRE colonization in all ICU patients vary depending on institutional epidemiology and resources. The present study was aimed to evaluate the performance of HiCrome Klebsiella pneumoniae carbapenemase (KPC) agar for the detection of CRE colonization in ICU settings taking the Centers for Disease Control and Prevention (CDC) recommended method as reference. Methods Two-hundred and eighty rectal swabs (duplicate) from 140 patients were subjected to CRE detection in HiCrome KPC agar and MacConkey agar (CDC criteria). Results Using CDC method, total 41 CRE isolates were recovered comprising of 29 E scherichia coli, 11 Klebsiella, and 1 Enterobacter spp. On the other hand, 49 isolates of CRE recovered from 140 rectal swabs using HiCrome KPC agar, out of which 33 were E. coli, 15 Klebsiella, and 1 Enterobacter sp. Statistical Analysis Sensitivity, specificity, negative, and positive predictive values of CRE screening by HiCrome KPC agar were found to be 100% (91.4–100), 91.9% (84.8–95.8), 83.6% (70.9–91.4), and 100% (95.9–100), respectively, taking the CDC recommended method as reference. Conclusion HiCrome KPC agar has high sensitivity in screening CRE colonization. Further studies are needed to establish its applicability for detecting the predominant circulating carbapenemases in the Indian setting.


Medicina ◽  
2021 ◽  
Vol 57 (5) ◽  
pp. 503
Author(s):  
Thomas F. Monaghan ◽  
Syed N. Rahman ◽  
Christina W. Agudelo ◽  
Alan J. Wein ◽  
Jason M. Lazar ◽  
...  

Sensitivity, which denotes the proportion of subjects correctly given a positive assignment out of all subjects who are actually positive for the outcome, indicates how well a test can classify subjects who truly have the outcome of interest. Specificity, which denotes the proportion of subjects correctly given a negative assignment out of all subjects who are actually negative for the outcome, indicates how well a test can classify subjects who truly do not have the outcome of interest. Positive predictive value reflects the proportion of subjects with a positive test result who truly have the outcome of interest. Negative predictive value reflects the proportion of subjects with a negative test result who truly do not have the outcome of interest. Sensitivity and specificity are inversely related, wherein one increases as the other decreases, but are generally considered stable for a given test, whereas positive and negative predictive values do inherently vary with pre-test probability (e.g., changes in population disease prevalence). This article will further detail the concepts of sensitivity, specificity, and predictive values using a recent real-world example from the medical literature.


Diagnostics ◽  
2019 ◽  
Vol 9 (3) ◽  
pp. 109 ◽  
Author(s):  
Ukweh ◽  
Ugbem ◽  
Okeke ◽  
Ekpo

Background: Ultrasound is operator-dependent, and its value and efficacy in fetal morphology assessment in a low-resource setting is poorly understood. We assessed the value and efficacy of fetal morphology ultrasound assessment in a Nigerian setting. Materials and Methods: We surveyed fetal morphology ultrasound performed across five facilities and followed-up each fetus to ascertain the outcome. Fetuses were surveyed in the second trimester (18th–22nd weeks) using the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) guideline. Clinical and surgical reports were used as references to assess the diagnostic efficacy of ultrasound in livebirths, and autopsy reports to confirm anomalies in terminated pregnancies, spontaneous abortions, intrauterine fetal deaths, and still births. We calculated sensitivity, specificity, positive and negative predictive values, Area under the curve (AUC), Youden index, likelihood ratios, and post-test probabilities. Results: In total, 6520 fetuses of women aged 15–46 years (mean = 31.7 years) were surveyed. The overall sensitivity, specificity, and AUC were 77.1 (95% CI: 68–84.6), 99.5 (95% CI: 99.3–99.7), and 88.3 (95% CI: 83.7–92.2), respectively. Other performance metrics were: positive predictive value, 72.4 (95% CI: 64.7–79.0), negative predictive value, 99.6 (95% CI: 99.5–99.7), and Youden index (77.1%). Abnormality prevalence was 1.67% (95% CI: 1.37–2.01), and the positive and negative likelihood ratios were 254 (95% CI: 107.7–221.4) and 0.23 (95% CI: 0.16–0.33), respectively. The post-test probability for positive test was 72% (95% CI: 65–79). Conclusion: Fetal morphology assessment is valuable in a poor economics setting, however, the variation in the diagnostic efficacy across facilities and the limitations associated with the detection of circulatory system anomalies need to be addressed.


2021 ◽  
Vol 24 (2) ◽  
pp. 196-203
Author(s):  
Elahe Fini ◽  
◽  
Neda Nasirian ◽  
Bahram Hosein Beigy ◽  
◽  
...  

Background and Aim: Ovarian cancer is among the most common cancers in women worldwide. CA125 is the most frequent biomarker used in the screening for ovarian cancer. CA125 has no high sensitivity and specificity as a screening test in the medical community; however, because of being simple and noninvasive, it is almost always requested for evaluation and ruling out cancer. It plays an important role in the treatment and post-treatment process, the prediction of prognosis, and the relapse of the disease. The present study aimed to determine the relationship between a high level of CA125 tumor marker and ovarian cancer by detecting spesivity, sensivity, positive and negative predictive values. Methods & Materials: In this cross-sectional study, all cases undergoing CA125 test in Velayat Hospital in 2017-1028 were evaluated for having ovarian cancer. In addition, the CA125 level was compared between healthy individuals and patients with ovarian cancer. Finally, the obtained data were analyzed using SPSS. Ethical Considerations: The present study was approved by the Qazvin University of Medical Sciences (Ethics Code: IR.QUMS.REC.1396.316). Results: In this study, 35.3% of the study participants received a definite diagnosis of ovarian cancer. Generally, CA125 values were negative in 41.8% and positive in.58.2% of the study subjects. The sensitivity of the test was measured as 80.1%, the specivity as 53.6%, the positive predictive value equaled 48.4%, and the negative predictive value was measured as 83%. There was a significant relationship between age and the presence of ovarian cancer, and serum CA125 levels. Conclusion: The present study suggested that age and the serum level of CA125 were statistically significant. Finally, CA125 levels were significantly related to ovarian cancer. It provided moderate specivity and specivity as well as low positive predictive value and high negative predictive value as a tumor marker; it is valuable for ruling out of tumor but not appropriate as a screening test.


Sign in / Sign up

Export Citation Format

Share Document