scholarly journals Comparison of the optical quality after SMILE and FS-LASIK for high myopia by OQAS and iTrace analyzer: a one-year retrospective study

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Yewei Yin ◽  
Ying Lu ◽  
Aiqun Xiang ◽  
Yanyan Fu ◽  
Yang Zhao ◽  
...  

Abstract Background To compare the correction effect and optical quality after small-incision lenticule extraction (SMILE) and femtosecond laser assisted laser in situ keratomileusis (FS-LASIK) for high myopia. Methods 51 high myopia eyes after SMILE and 49 high myopia eyes after FS-LASIK were enrolled and divided into two groups retrospectively. The OQAS and iTrace analyzer were used for optical quality inspection. Between the two groups the spherical equivalent (SE), astigmatism, uncorrected distant visual acuity (UDVA), strehl ratio (SR), modulation transfer function cutoff frequency (MTF cutoff), objective scatter index (OSI) and wavefront aberrations were analyzed and compared before surgery and at 1, 6 and 12 months after surgery. Results After the operation: (1) SE and astigmatism declined and UDVA increased significantly in both groups, and UDVA was better after SMILE than FS-LASIK. (2) SR and MTF cutoff reduced and OSI increased significantly after SMILE and FS-LASIK. SR and MTF cutoff were significantly higher after SMILE than FS-LASIK. OSI was significantly lower after SMILE than FS-LASIK. (3) The total wavefront aberration, total low-order wavefront aberration, defocus and astigmatism aberration as well as trefoil aberration reduced significantly in both groups. The total high-order wavefront aberration increased significantly after FS-LASIK. The spherical and coma aberration increased significantly in both groups. The total high-order wavefront aberration and coma aberration at 1 month were higher after FS-LASIK than SMILE. Conclusion The optical quality descended after SMILE and FS-LASIK. SMILE was superior to FS-LASIK at the correction effect and optical quality for high myopia. The combination of OQAS and iTrace analyzer is a valuable complementary measurement in evaluating the optical quality after the refractive surgery. Trial registration This is a retrospective study. This research was approved by the ethics committee of Xiangya Hospital and the IRB approval number is 201612074.

2021 ◽  
Author(s):  
Gang Liang ◽  
Miao Zhou ◽  
Chen-Wei Pan

Abstract Background: To investigate the differences in visual quality after laser epithelial keratomileusis (LASEK), femtosecond laser in situ keratomileusis (FS-LASIK) and small-incision lenticule extraction (SMILE) in different degrees of myopia.Methods: This prospective study incorporated 200 consecutive myopic subjects (200 eyes). Myopia was subdivided into 3 levels based on the preoperative spherical equivalent (SE) value: low myopia (SE ≥ -3.0 D), moderate myopia (−3.0 D > SE ≥ −6.0 D), and high myopia (SE < −6.0 D). Visual quality was recorded and analyzed both objectively using the Optical Quality Analysis System II (OQAS II), and subjectively with uncorrected distance visual acuity (UDVA) and a questionnaire, preoperatively, 1 month and 6 months postoperatively. Results: Six months after LASEK, FS-LASIK and SMILE in myopia, the logarithm of the minimum angle of resolution (LogMAR) UDVA statistically decreased compared with preoperative values (all P < 0.001). While preoperatively, in three surgical procedure groups, objective visual quality parameters demonstrated no significant difference among three degrees of myopia (all P > 0.05), at 6 months postoperatively, after FS-LASIK and SMILE, the modulation transfer function (MTF) cutoff frequency in low myopia was significantly higher than that in high myopia (both P < 0.05). Moreover, intergroup differences in LASEK, FS-LASIK and SMILE groups were not statistically significant, before and 6 months after surgery (all P > 0.05), except that FS-LASIK provided a significantly higher preoperative LogMAR UDVA than SMILE in high myopia (P < 0.05).Conclusion: LASEK, FS-LASIK and SMILE could achieve similar improvement in visual quality to each other after myopia correction. Low myopic patients may achieve better postoperative visual quality after FS-LASIK and SMILE than high myopic patients.Trial registration: This is a prospective study. The study followed the Declaration of Helsinki and was approved by the Institutional Review Board of the Second People’s Hospital of Yunnan Province.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Xiao-ling Jiao ◽  
Jun Li ◽  
Zhe Yu ◽  
Ping-hui Wei ◽  
Hui Song

Abstract Background To compare visual performance between the iris-fixated phakic intraocular len (pIOL) and implantable collamer len (ICL) to correct high myopia. Methods Twenty-four eyes underwent iris-fixated pIOL implantation and 24 eyes underwent ICL implantation. At the 6-month follow-up, the best-corrected visual acuity (BCVA) and uncorrected distance visual acuity (UDVA) were compared between the iris-fixated pIOL and ICL groups. The objective scatter index (OSI), modulation transfer function (MTF) cutoff, and ocular aberrations were performed to evaluate postoperative visual quality between the two groups. Results No significant difference was found in UDVA, BCVA, and spherical equivalent between the iris-fixated pIOL and ICL groups (P > 0.05). Six months after surgery, the following values were significantly higher in the ICL group than in the iris-fixated pIOL group: MTF cutoff, strehl ratio and optical quality analysis system values at contrasts of 9 %, 20 %, and 100 % (P < 0.01). The OSI in the iris-fixated pIOL group was higher than in the ICL group 6 months after surgery (P < 0.01). All high-order aberrations were slightly more severe in the iris-fixated pIOL group than in the ICL group 6 months after surgery, although only trefoil (P = 0.023) differed significantly in this regard. Conclusions Both iris-fixated lenses and ICLs can provide good visual acuity. ICLs confer better visual performance in MTF-associated parameters and induce less intraocular light scattering than iris-fixated pIOLs.


2021 ◽  
Vol 14 (5) ◽  
pp. 737-743
Author(s):  
Zheng Jiang ◽  
◽  
Dong-Qiang Luo ◽  
Jiao Chen ◽  
◽  
...  

AIM: To compare clinical outcomes and refractive stability of implantable collamer lens (ICL) implantation and femtosecond laser assisted laser in situ keratomileusis (FS-LASIK) for high myopia correction. METHODS: The Optical Quality Analysis System (OQAS) was used to evaluate clinical outcomes objectively after operation for high myopia correction. We compared the two procedures in terms of 1-year changes in uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), safety index, efficacy index, spherical equivalent, modulation transfer function (MTF) cutoff frequency, strehl ratio (SR) and objective scatter index (OSI). RESULTS: At 1y postoperatively, the safety indices were 1.33±0.27 in ICL group, and 1.17±0.24 in FS-LASIK group. 39.58% in the ICL group and 27.59% in the FS-LASIK group gained CDVA in 2 lines or better than that in preoperative CDVA. The efficacy indices were 1.28±0.22 in ICL group, and 1.13±0.26 in FS-LASIK group. The changes of spherical equivalent from 1wk to 1y postoperatively was -0.12±0.37 D in ICL group, and -0.79±0.58 D in FS-LASIK group (P&#x003C;0.05). Spherical equivalent within ±0.50 D was achieved in 97.92% in ICL group and 68.97% in FS-LASIK group. MTF cutoff frequency were higher with ICL as compared to FS-LASIK (P&#x003C;0.05) at each postoperative follow-up stage; for postoperative 1mo later, SR was statistically significant difference between two groups (P&#x003C;0.05); with no statistically significant difference in OSI between two groups (P&#x003E;0.05) in postoperative 3mo later. CONCLUSION: ICL implantation and FS-LASIK procedures both provide good safety and predictability in high myopia correction. ICL implantation provides better clinical outcomes and refractive stability than FS-LASIK.


Polymers ◽  
2020 ◽  
Vol 12 (4) ◽  
pp. 993 ◽  
Author(s):  
Tomás Lloret ◽  
Víctor Navarro-Fuster ◽  
Manuel G. Ramírez ◽  
Marta Morales-Vidal ◽  
Augusto Beléndez ◽  
...  

Aberrations and the image quality of holographic lenses were evaluated by a Hartmann–Shack (HS) wavefront sensor. Two lenses, one recorded with a symmetrical configuration and the other with an asymmetrical one, were stored in a photopolymer called Biophotopol. Each was reconstructed with two different wavelengths, 473 nm and 633 nm. Different metrics were applied to determine and quantify the aberration of the lenses (Zernike coefficients, Seidel coefficients, Marechal tolerances, root-mean-square (RMS), peak to valley, critical fraction of the pupil), and the quality of the image they provided (Strehl ratio, entropy, cutoff frequency, modulation transfer function (MTF), and area under the MTF). Good agreement between the metrics related to optical quality was obtained. The negative asymmetric holographic lenses had less aberration than the positive symmetric ones.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Mohammad Miraftab ◽  
Hassan Hashemi ◽  
Mohammadreza Aghamirsalim ◽  
Shiva Fayyaz ◽  
Soheila Asgari

Abstract Background The refractive surgeries induce corneal higher order aberrations (C-HOAs). In this study, change of C-HOAs after small-incision lenticule extraction (SMILE) compared to femtosecond assisted laser in situ keratomileusis (femto-LASIK), and to photorefractive keratectomy with mitomycin-C (PRK) under photopic and mesopic conditions. Methods In this prospective study, age, gender, and apical corneal thickness (ACT) matched cases with moderate myopia [spherical equivalent (SE) 3.00 to 6.00D) to high myopia (SE > 6.00D)] were enrolled. In addition to visual acuity and refraction, total C-HOA, coma, spherical aberration (SA), and trefoil in the 3- and 6-mm zones were measured before and 3 and 6 months after surgery. Results Overall, 372 moderate myopia cases (124 eyes of 124 individuals in each surgical group) and 171 high myopia cases (57 eyes of 57 individuals in each surgical group) were enrolled. At baseline, the differences in age, gender, ACT, uncorrected and corrected visual acuity, and SE were not statistically significant between subgroups of surgical methods within each myopia group (all P > 0.05). At 12 months, in the moderate myopia group, there was less increase in 6-mm zone total C-HOA, coma, and SA with SMILE compared to the other groups (all P < 0.05). In the high myopia group, there was greater increase in photopic total C-HOA and trefoil and less increase in mesopic SA with SMILE (all P < 0.05). Conclusions In correction of moderate myopia, SMILE has better results in mesopic condition. In high myopia correction, femto-LASIK and PRK have better results in photopic and SMILE in mesopic condition.


2021 ◽  
pp. 112067212110021
Author(s):  
Javier Ruiz-Alcocer ◽  
Irene Martínez-Alberquilla ◽  
Amalia Lorente-Velázquez ◽  
José F Alfonso ◽  
David Madrid-Costa

Purpose: To objectively analyze the optical quality of the FineVision Toric intraocular lens (IOL) with two cylinder powers when different combinations of rotations and residual refractive errors are induced. Methods: This study assessed the FineVision Toric IOL with two different cylinder powers: 1.5 and 3.0 diopters (D). Three different rotation positions were considered: centered, 5° and 10° rotated. An optical bench (PMTF) was used for optical analysis. The optical quality of the IOLs was calculated by the modulation transfer function (MTF) at five different focal points (0.0, 0.25, 0.50, 0.75, and 1.00 D). Results: The MTF averaged value of the reference situation was 38.58 and 37.74 for 1.5 and 3.0 D of cylinder, respectively. For the 1.5 D cylinder, the combination of 5° of rotation with a defocus of 0.25, 0.50, 0.75, and 1.0 D induced a decrease on the MTF of 12.39, 19.94, 23.43, 24.23 units, respectively. When induced rotation was 10°, the MTF decrease was 17.26, 23.40, 24.33, 24.48 units, respectively. For the 3.0 D cylinder, the combination of 5° with 0.25, 0.50, 0.75, and 1.0 D of defocus, induced a decrease on the MTF of 12.51, 18.97, 22.36, 22.48 units, respectively. When induced rotation was 10°, the MTF decrease was: 18.42, 21.57, 23.08, and 23.61 units, respectively. Conclusion: For both FineVision Toric IOLs there is a certain optical tolerance to rotations up to 5° or residual refractive errors up to 0.25 D. Situations over these limits and their combination would affect the visual quality of patients implanted with these trifocal toric IOLs.


2008 ◽  
Vol 34 (12) ◽  
pp. 2073-2078 ◽  
Author(s):  
Dimitri T. Azar ◽  
Ramon C. Ghanem ◽  
Jose de la Cruz ◽  
Joelle A. Hallak ◽  
Takashi Kojima ◽  
...  

2021 ◽  
pp. bjophthalmol-2020-316234
Author(s):  
Jan Roelof Polling ◽  
Caroline Klaver ◽  
Jan Willem Tideman

PurposeData on myopia progression during its entire course are scarce. The aim of this study is to investigate myopia progression in Europeans as a function of age and degree of myopia from first prescription to final refractive error.MethodsThe Drentse Refractive Error and Myopia Study assessed data from a branch of opticians in the Netherlands from 1985 onwards in a retrospective study. First pair of glasses prescribed was defined as a spherical equivalent of refraction (SER) ≤−0.5 D to ≥−3.0 D. Subjects with prescriptions at an interval of at least 1 year were included in the analysis.ResultsA total of 2555 persons (57.3% female) met the inclusion criteria. Those with first prescription before the age of 10 years showed the strongest progression (−0.50 D; IQR: −0.75 to −0.19) and a significantly (p<0.001) more negative median final SER (−4.48 D; IQR: −5.37 to −3.42). All children who developed SER ≤−3 D at 10 years were highly myopic (SER ≤−6D) as adults, children who had SER between −1.5 D and −3 D at 10 years had 46.0% risk of high myopia, and children with SER between −0.5 D and −1.5 D had 32.6% risk of high myopia. Myopia progression diminished with age; all refractive categories stabilised after age 15 years except for SER ≤−5 D who progressed up to −0.25 D annually until age 21 years.ConclusionOur trajectories of the natural course of myopia progression may serve as a guide for myopia management in European children. SER at 10 years is an important prognostic indicator and will help determine treatment intensity.


2020 ◽  
Vol 1 (1) ◽  
pp. 42-46
Author(s):  
Jian-He Xiao ◽  
◽  
Shi-Yang Li ◽  
Xing Xing ◽  
Ai-Hong Zhao ◽  
...  

AIM: To evaluate the quality of life of recruits after refractive surgery. METHODS: Population-based, cross-sectional study. Using the Quality of Life Impact of Refractive Correction (QIRC) questionnaire, the quality of life in 615 recruits underwent refractive surgery was evaluated. The overall score and each question score of QIRC were compared between subgroups of different strength of preoperative refractive error, postoperative interval, type of surgical procedure and postoperative recovery. RESULTS: The mean overall QIRC score of recruits underwent refractive surgery was 49.15±7.89. Significant difference was found for strength of preoperative refractive error (F=4.16, P<0.05), with the low myopia group (50.67±7.59) had significantly better scores than those with high myopia (47.57±7.52, F=4.16, P<0.05). Recruits after a postoperative interval no more than 6mo (49.18±7.86) scored equally to those of more than 6mo (49.18±8.03). Recruits underwent surface ablation surgery scored lowest (46.68±6.09), but showed no significant difference when compared with all underwent refractive surgery (t=1.99, P>0.05). Scores of recruits underwent mechanical microkeratome laser in situ keratomileusis (MK-LASIK), Sub-Bowman’s keratomileusis (SBK), femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK), femtosecond lenticule extraction (ReLEx flex) or small-incision lenticule extraction (ReLEx SMILE) procedure showed no significant difference too. Recruits had adverse complaints postoperatively (45.85±6.66) scored lower when compared with all underwent refractive surgery (t=5.28, P<0.01). CONCLUSION: The quality of life of recruits after refractive surgery was good except those with postoperative complications. Preoperative low myopia recruits had better quality of life than medium and high myopia ones.