scholarly journals Comparison of Objective and Subjective Visual Quality Following LASEK, FS-LASIK and SMILE for Different Myopic Corrections: A Prospective Study

Author(s):  
Gang Liang ◽  
Miao Zhou ◽  
Chen-Wei Pan

Abstract Background: To investigate the differences in visual quality after laser epithelial keratomileusis (LASEK), femtosecond laser in situ keratomileusis (FS-LASIK) and small-incision lenticule extraction (SMILE) in different degrees of myopia.Methods: This prospective study incorporated 200 consecutive myopic subjects (200 eyes). Myopia was subdivided into 3 levels based on the preoperative spherical equivalent (SE) value: low myopia (SE ≥ -3.0 D), moderate myopia (−3.0 D > SE ≥ −6.0 D), and high myopia (SE < −6.0 D). Visual quality was recorded and analyzed both objectively using the Optical Quality Analysis System II (OQAS II), and subjectively with uncorrected distance visual acuity (UDVA) and a questionnaire, preoperatively, 1 month and 6 months postoperatively. Results: Six months after LASEK, FS-LASIK and SMILE in myopia, the logarithm of the minimum angle of resolution (LogMAR) UDVA statistically decreased compared with preoperative values (all P < 0.001). While preoperatively, in three surgical procedure groups, objective visual quality parameters demonstrated no significant difference among three degrees of myopia (all P > 0.05), at 6 months postoperatively, after FS-LASIK and SMILE, the modulation transfer function (MTF) cutoff frequency in low myopia was significantly higher than that in high myopia (both P < 0.05). Moreover, intergroup differences in LASEK, FS-LASIK and SMILE groups were not statistically significant, before and 6 months after surgery (all P > 0.05), except that FS-LASIK provided a significantly higher preoperative LogMAR UDVA than SMILE in high myopia (P < 0.05).Conclusion: LASEK, FS-LASIK and SMILE could achieve similar improvement in visual quality to each other after myopia correction. Low myopic patients may achieve better postoperative visual quality after FS-LASIK and SMILE than high myopic patients.Trial registration: This is a prospective study. The study followed the Declaration of Helsinki and was approved by the Institutional Review Board of the Second People’s Hospital of Yunnan Province.

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Xiao-ling Jiao ◽  
Jun Li ◽  
Zhe Yu ◽  
Ping-hui Wei ◽  
Hui Song

Abstract Background To compare visual performance between the iris-fixated phakic intraocular len (pIOL) and implantable collamer len (ICL) to correct high myopia. Methods Twenty-four eyes underwent iris-fixated pIOL implantation and 24 eyes underwent ICL implantation. At the 6-month follow-up, the best-corrected visual acuity (BCVA) and uncorrected distance visual acuity (UDVA) were compared between the iris-fixated pIOL and ICL groups. The objective scatter index (OSI), modulation transfer function (MTF) cutoff, and ocular aberrations were performed to evaluate postoperative visual quality between the two groups. Results No significant difference was found in UDVA, BCVA, and spherical equivalent between the iris-fixated pIOL and ICL groups (P > 0.05). Six months after surgery, the following values were significantly higher in the ICL group than in the iris-fixated pIOL group: MTF cutoff, strehl ratio and optical quality analysis system values at contrasts of 9 %, 20 %, and 100 % (P < 0.01). The OSI in the iris-fixated pIOL group was higher than in the ICL group 6 months after surgery (P < 0.01). All high-order aberrations were slightly more severe in the iris-fixated pIOL group than in the ICL group 6 months after surgery, although only trefoil (P = 0.023) differed significantly in this regard. Conclusions Both iris-fixated lenses and ICLs can provide good visual acuity. ICLs confer better visual performance in MTF-associated parameters and induce less intraocular light scattering than iris-fixated pIOLs.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Yewei Yin ◽  
Ying Lu ◽  
Aiqun Xiang ◽  
Yanyan Fu ◽  
Yang Zhao ◽  
...  

Abstract Background To compare the correction effect and optical quality after small-incision lenticule extraction (SMILE) and femtosecond laser assisted laser in situ keratomileusis (FS-LASIK) for high myopia. Methods 51 high myopia eyes after SMILE and 49 high myopia eyes after FS-LASIK were enrolled and divided into two groups retrospectively. The OQAS and iTrace analyzer were used for optical quality inspection. Between the two groups the spherical equivalent (SE), astigmatism, uncorrected distant visual acuity (UDVA), strehl ratio (SR), modulation transfer function cutoff frequency (MTF cutoff), objective scatter index (OSI) and wavefront aberrations were analyzed and compared before surgery and at 1, 6 and 12 months after surgery. Results After the operation: (1) SE and astigmatism declined and UDVA increased significantly in both groups, and UDVA was better after SMILE than FS-LASIK. (2) SR and MTF cutoff reduced and OSI increased significantly after SMILE and FS-LASIK. SR and MTF cutoff were significantly higher after SMILE than FS-LASIK. OSI was significantly lower after SMILE than FS-LASIK. (3) The total wavefront aberration, total low-order wavefront aberration, defocus and astigmatism aberration as well as trefoil aberration reduced significantly in both groups. The total high-order wavefront aberration increased significantly after FS-LASIK. The spherical and coma aberration increased significantly in both groups. The total high-order wavefront aberration and coma aberration at 1 month were higher after FS-LASIK than SMILE. Conclusion The optical quality descended after SMILE and FS-LASIK. SMILE was superior to FS-LASIK at the correction effect and optical quality for high myopia. The combination of OQAS and iTrace analyzer is a valuable complementary measurement in evaluating the optical quality after the refractive surgery. Trial registration This is a retrospective study. This research was approved by the ethics committee of Xiangya Hospital and the IRB approval number is 201612074.


2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Zhonghao Ren ◽  
Liyan Xu ◽  
Qi Fan ◽  
Kaili Yang ◽  
Shengwei Ren ◽  
...  

Purpose. The study aimed to evaluate the visual quality of forme fruste keratoconus (FFK) and mild and moderate keratoconus by using an optical quality analysis system II (OQAS-II) and to explore the correlation between optical quality parameters and the disease progression. Methods. Twenty-one normal eyes, twenty-one FFK eyes, twenty-one mild keratoconus eyes, and twenty-one moderate keratoconus eyes were included in this prospective study. The optical quality parameters, such as object scatter index (OSI), modulation transfer function cutoff (MTF cutoff), strehl ratio (SR), and OQAS-II values at contrasts of 100% (OV-100), 20% (OV-20), and 9% (OV-9), were measured by OQAS-II. The repeatability of these parameters was analyzed by intraclass correlation coefficient (ICC), repeatability coefficient (RC), and coefficient of variation (CVw). Correlations between optical quality parameters and mean central keratometry readings (Kmean) were evaluated. The sensitivity and specificity of the parameters were analyzed using the receiver operating characteristic (ROC). Results. All the optical quality parameters among four groups showed good repeatability (all ICC≥0.75). The MTF cutoff, SR, OV-100, OV-20, OV-9 in FFK, mild and moderate keratoconus eyes were significantly lower than those in the normal group (all P<0.05). The ROC analyses of the MTF cutoff, SR, OV-100, OV-20, and OV-9 showed significant area under the curve (AUC) in discriminating FFK form normal, mild keratoconus from FFK, and moderate keratoconus from mild keratoconus (all P<0.05). The OSI in mild and moderate keratoconus eyes were significantly higher than that in FFK and normal group (all P<0.05), while the OSI showed no significant difference between the FFK group and normal group (P>0.05). The ROC analyses of the OSI showed significant AUC in discriminating mild keratoconus from FFK and moderate keratoconus from mild keratoconus (all P<0.05). In addition, the MTF cutoff was closely correlated to Kmean in keratoconus eyes (r = −0.710, P<0.001). Conclusion. The repeatability of OQAS-II is good in measuring visual quality of normal as well as FFK, mild, and moderate keratoconus. The visual quality of the FFK, mild, and moderate keratoconus is worse than that in normal eyes. The OQAS-II has the potential value in screening FFK from normal eyes and might be a useful tool for evaluating the progression of keratoconus.


2021 ◽  
Vol 14 (5) ◽  
pp. 737-743
Author(s):  
Zheng Jiang ◽  
◽  
Dong-Qiang Luo ◽  
Jiao Chen ◽  
◽  
...  

AIM: To compare clinical outcomes and refractive stability of implantable collamer lens (ICL) implantation and femtosecond laser assisted laser in situ keratomileusis (FS-LASIK) for high myopia correction. METHODS: The Optical Quality Analysis System (OQAS) was used to evaluate clinical outcomes objectively after operation for high myopia correction. We compared the two procedures in terms of 1-year changes in uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), safety index, efficacy index, spherical equivalent, modulation transfer function (MTF) cutoff frequency, strehl ratio (SR) and objective scatter index (OSI). RESULTS: At 1y postoperatively, the safety indices were 1.33±0.27 in ICL group, and 1.17±0.24 in FS-LASIK group. 39.58% in the ICL group and 27.59% in the FS-LASIK group gained CDVA in 2 lines or better than that in preoperative CDVA. The efficacy indices were 1.28±0.22 in ICL group, and 1.13±0.26 in FS-LASIK group. The changes of spherical equivalent from 1wk to 1y postoperatively was -0.12±0.37 D in ICL group, and -0.79±0.58 D in FS-LASIK group (P&#x003C;0.05). Spherical equivalent within ±0.50 D was achieved in 97.92% in ICL group and 68.97% in FS-LASIK group. MTF cutoff frequency were higher with ICL as compared to FS-LASIK (P&#x003C;0.05) at each postoperative follow-up stage; for postoperative 1mo later, SR was statistically significant difference between two groups (P&#x003C;0.05); with no statistically significant difference in OSI between two groups (P&#x003E;0.05) in postoperative 3mo later. CONCLUSION: ICL implantation and FS-LASIK procedures both provide good safety and predictability in high myopia correction. ICL implantation provides better clinical outcomes and refractive stability than FS-LASIK.


2020 ◽  
Vol 2020 ◽  
pp. 1-10
Author(s):  
Jun Li ◽  
Zhe Yu ◽  
Hui Song

Purpose. To investigate the effects of capsulotomy shape on the visual acuity and visual quality after neodymium: yttrium aluminum garnet laser capsulotomy. Methods. In this study, a total of 42 eyes from 35 patients with posterior capsule opacification were divided into the circular and cruciate groups. The corrected distance visual acuity (CDVA), objective scatter index (OSI), modulation transfer function cutoff (MTF cutoff), Strehl ratio, and Optical Quality Analysis System values at contrasts of 100%, 20%, and 9% (OV-100, OV-20, and OV-9) were measured at precapsulotomy and 1 week and 1 month postcapsulotomy. The pseudophakic dysphotopsia questionnaire (PDQ) was used to evaluate the subjects’ satisfaction with treatment. Results. OSI values were significantly higher in the cruciate group than in the circular group at 1 week and 1 month after capsulotomy (P=0.013 and P<0.001). No significant difference was found in the OSI values between the two groups before capsulotomy (t = 0.52; P=0.61). The decrease in OSI was higher in the circular group than in the cruciate group at 1 week and 1 month after capsulotomy (P=0.036 and P=0.019). No significant differences were found in the Strehl ratio, MTF cutoff, CDVA, OV-100, OV-20, and OV-9 between the two groups at 1 week and 1 month after capsulotomy (P>0.05). The PDQ results showed that patients with circular-shaped capsulotomy complained less with intolerance of bright lights than those with cruciate-shaped capsulotomy. Conclusions. Circular-shaped capsulotomy can induce less intraocular light scattering and increase patient satisfaction.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Bo Lu ◽  
Weijie Zhu ◽  
Yu Fan ◽  
Dong Shi ◽  
Liwei Ma

Abstract Background A prospective cohort study was performed to evaluate whether the Optical Quality Analysis System (OQAS) can serve as a valuable additional indicator for appropriate posterior capsulotomy referral. Methods One hundred and five eyes from 96 patients undergoing capsulotomy were divided into precapsulotomy logMAR CDVA ≤0.1 group and logMAR CDVA > 0.1 group. CDVA, and the Visual Function 14 index (VF-14) score were estimated before and 1 month after capsulotomy. The objective scattering index (OSI) value was measured by using the OQAS. Posterior capsule opacification (PCO) severity was assessed with Evaluation of PCO 2000 (EPCO 2000) software. Results In logMAR CDVA > 0.1 group, the correlations of OSI, logMAR CDVA, EPCO score and VF-14 score were very strong preoperatively. In logMAR CDVA ≤0.1 group, preoperatively, OSI was correlated with logMAR CDVA (r = 0.451), EPCO score (r = 0.789), and VF-14 score (r = 0.852). LogMAR CDVA has weak correlation with VF-14 score (r = − 0.384) and EPCO score (r = 0.566). VF-14 score was correlated with EPCO score (r = − 0.669). In the logMAR CDVA ≤0.1 group, there was no significant difference in logMAR CDVA between precapsulotomy and postcapsulotomy (P > 0.05). In the two groups, all the other optical quality parameters were significantly improved after capsulotomy (P < 0.05). In logMAR CDVA > 0.1 group, the area under the curve of the ROC of the OSI was 0.996 (P = 0.000). In logMAR CDVA ≤0.1 group, the area under the curve of the ROC of the OSI was 0.943 (P = 0.000). Conclusions The OSI was useful for evaluating of PCO and prediction of beneficial capsulotomy. Especially for patients with slight PCO and better visual acuity, OSI is more valuable than CDVA and completely objective examination. Trial registration The study protocol was registered at the Chinese Clinical Trial Registry. Register: ChiCTR1800018842 (Registered Date: October 13th, 2018).


2016 ◽  
Vol 2016 ◽  
pp. 1-7 ◽  
Author(s):  
Min-jie Ye ◽  
Cai-yuan Liu ◽  
Rong-feng Liao ◽  
Zheng-yu Gu ◽  
Bing-ying Zhao ◽  
...  

Purpose. To compare the change of anterior corneal higher-order aberrations (HOAs) after laser in situ keratomileusis (LASIK), wavefront-guided LASIK with iris registration (WF-LASIK), femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK), and small incision lenticule extraction (SMILE).Methods. In a prospective study, 82 eyes underwent LASIK, 119 eyes underwent WF-LASIK, 88 eyes underwent FS-LASIK, and 170 eyes underwent SMILE surgery. HOAs were measured with Pentacam device preoperatively and 6 months after surgery. The aberrations were described as Zernike polynomials, and analysis focused on total HOAs, spherical aberration (SA), horizontal coma, and vertical coma over 6 mm diameter central corneal zone.Results. Six months postoperatively, all procedures result in increase of anterior corneal total HOAs and SA. There were no significant differences in the induced HOAs between LASIK and FS-LASIK, while SMILE induced fewer total HOAs and SA compared with LASIK and FS-LASIK. Similarly, WF-LASIK also induced less total HOAs than LASIK and FS-LASIK, but only fewer SA than FS-LASIK (P<0.05). No significant difference could be detected in the induced total HOAs and SA between SMILE and WF-LASIK, whereas SMILE induced more horizontal coma and vertical coma compared with WF-LASIK (P<0.05).Conclusion. FS-LASIK and LASIK induced comparable anterior corneal HOAs. Compared to LASIK and FS-LASIK, both SMILE and WF-LASIK showed advantages in inducing less total HOAs. In addition, SMILE also possesses better ability to reduce the induction of SA in comparison with LASIK and FS-LASIK. However, SMILE induced more horizontal coma and vertical coma compared with WF-LASIK, indicating that the centration of SMILE procedure is probably less precise than WF-LASIK.


2021 ◽  
pp. 112067212110021
Author(s):  
Javier Ruiz-Alcocer ◽  
Irene Martínez-Alberquilla ◽  
Amalia Lorente-Velázquez ◽  
José F Alfonso ◽  
David Madrid-Costa

Purpose: To objectively analyze the optical quality of the FineVision Toric intraocular lens (IOL) with two cylinder powers when different combinations of rotations and residual refractive errors are induced. Methods: This study assessed the FineVision Toric IOL with two different cylinder powers: 1.5 and 3.0 diopters (D). Three different rotation positions were considered: centered, 5° and 10° rotated. An optical bench (PMTF) was used for optical analysis. The optical quality of the IOLs was calculated by the modulation transfer function (MTF) at five different focal points (0.0, 0.25, 0.50, 0.75, and 1.00 D). Results: The MTF averaged value of the reference situation was 38.58 and 37.74 for 1.5 and 3.0 D of cylinder, respectively. For the 1.5 D cylinder, the combination of 5° of rotation with a defocus of 0.25, 0.50, 0.75, and 1.0 D induced a decrease on the MTF of 12.39, 19.94, 23.43, 24.23 units, respectively. When induced rotation was 10°, the MTF decrease was 17.26, 23.40, 24.33, 24.48 units, respectively. For the 3.0 D cylinder, the combination of 5° with 0.25, 0.50, 0.75, and 1.0 D of defocus, induced a decrease on the MTF of 12.51, 18.97, 22.36, 22.48 units, respectively. When induced rotation was 10°, the MTF decrease was: 18.42, 21.57, 23.08, and 23.61 units, respectively. Conclusion: For both FineVision Toric IOLs there is a certain optical tolerance to rotations up to 5° or residual refractive errors up to 0.25 D. Situations over these limits and their combination would affect the visual quality of patients implanted with these trifocal toric IOLs.


2020 ◽  
Vol 9 (8) ◽  
pp. 2509
Author(s):  
Masahiro Fukada ◽  
Nobuhisa Matsuhashi ◽  
Takao Takahashi ◽  
Nobuhiko Sugito ◽  
Kazuki Heishima ◽  
...  

Cancer-related microRNAs (miRNAs) are emerging as non-invasive biomarkers for colorectal cancer (CRC). This study aimed to analyze the correlation between the levels of tissue and plasma miRNAs and clinicopathological characteristics and surgical resection. This study was a prospective study of CRC patients who underwent surgery. Forty-four sample pairs of tissue and plasma were analyzed. The miRNA levels were evaluated by RT-qPCR. The level of tumor tissue MIR92a showed a significant difference in CRC with lymph node metastasis, stage ≥ III, and high lymphatic invasion. In preoperative plasma, there were significant differences in CRC with stage ≥ III (MIR29a) and perineural invasion (MIR21). In multivariate analysis of lymphatic invasion, the levels of both preoperative plasma MIR29a and tumor tissue MIR92a showed significant differences. Furthermore, in cases with higher plasma miRNA level, the levels of plasma MIRs21 and 29a were significantly decreased after the operation. In this study, there were significant differences in miRNAs levels with respect to the sample type, clinicopathological features, and surgical resection. The levels of tumor tissue MIR92a and preoperative plasma MIR29a may have the potential as a biomarker for prognosis. The plasma MIRs21 and 29a level has the potential to be a predictive biomarker for treatment efficacy.


2020 ◽  
Vol 1 (1) ◽  
pp. 42-46
Author(s):  
Jian-He Xiao ◽  
◽  
Shi-Yang Li ◽  
Xing Xing ◽  
Ai-Hong Zhao ◽  
...  

AIM: To evaluate the quality of life of recruits after refractive surgery. METHODS: Population-based, cross-sectional study. Using the Quality of Life Impact of Refractive Correction (QIRC) questionnaire, the quality of life in 615 recruits underwent refractive surgery was evaluated. The overall score and each question score of QIRC were compared between subgroups of different strength of preoperative refractive error, postoperative interval, type of surgical procedure and postoperative recovery. RESULTS: The mean overall QIRC score of recruits underwent refractive surgery was 49.15±7.89. Significant difference was found for strength of preoperative refractive error (F=4.16, P<0.05), with the low myopia group (50.67±7.59) had significantly better scores than those with high myopia (47.57±7.52, F=4.16, P<0.05). Recruits after a postoperative interval no more than 6mo (49.18±7.86) scored equally to those of more than 6mo (49.18±8.03). Recruits underwent surface ablation surgery scored lowest (46.68±6.09), but showed no significant difference when compared with all underwent refractive surgery (t=1.99, P>0.05). Scores of recruits underwent mechanical microkeratome laser in situ keratomileusis (MK-LASIK), Sub-Bowman’s keratomileusis (SBK), femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK), femtosecond lenticule extraction (ReLEx flex) or small-incision lenticule extraction (ReLEx SMILE) procedure showed no significant difference too. Recruits had adverse complaints postoperatively (45.85±6.66) scored lower when compared with all underwent refractive surgery (t=5.28, P<0.01). CONCLUSION: The quality of life of recruits after refractive surgery was good except those with postoperative complications. Preoperative low myopia recruits had better quality of life than medium and high myopia ones.