A NOTE ON THE DETERMINATION OF THE VISCOSITY OF SHALE FROM THE MEASUREMENT OF WAVELET BREADTH

Geophysics ◽  
1941 ◽  
Vol 6 (3) ◽  
pp. 254-258 ◽  
Author(s):  
Norman Ricker
Keyword(s):  

From the breadth of a wavelet for a given travel time, it is possible to calculate the viscosity of the formation through which the seismic disturbance has passed. This calculation has been carried out for the Cretaceous Shale of Eastern Colorado, and the value thus found ranges from [Formula: see text] to [Formula: see text], with a mean value of [Formula: see text] grams per cm. per second.

1996 ◽  
Vol 75 (05) ◽  
pp. 772-777 ◽  
Author(s):  
Sybille Albrecht ◽  
Matthias Kotzsch ◽  
Gabriele Siegert ◽  
Thomas Luther ◽  
Heinz Großmann ◽  
...  

SummaryThe plasma tissue factor (TF) concentration was correlated to factor VII concentration (FVIIag) and factor VII activity (FVIIc) in 498 healthy volunteers ranging in age from 17 to 64 years. Immunoassays using monoclonal antibodies (mAbs) were developed for the determination of TF and FVIIag in plasma. The mAbs and the test systems were characterized. The mean value of the TF concentration was 172 ± 135 pg/ml. TF showed no age- and gender-related differences. For the total population, FVIIc, determined by a clotting test, was 110 ± 15% and the factor VIlag was 0.77 ± 0.19 μg/ml. FVII activity was significantly increased with age, whereas the concentration demonstrated no correlation to age in this population. FVII concentration is highly correlated with the activity as measured by clotting assay using rabbit thromboplastin. The ratio between FVIIc and FVIIag was not age-dependent, but demonstrated a significant difference between men and women. Between TF and FVII we could not detect a correlation.


1966 ◽  
Vol 16 (01/02) ◽  
pp. 038-050 ◽  
Author(s):  
Ulla Hedner ◽  
Inga Marie Nilsson ◽  
B Robertson

SummaryThe plasminogen content was determined by a casein method in plasma and serum from 20 normal volunteers. The mean plasminogen content was found to be 10.1 ACU (the arbitrary caseinolytic unit defined in such a way that using a 3% casein solution and a digestion time of 20 min. at 37°C, 10 ACU gave an extinction of 0.300). No difference between serum and plasma regarding the plasminogen content was found.Plasminogen was determined in drained and drained plus washed clots prepared from 2 ml plasma. The highest values found in the drained clots were 0.9 ACU/clot and 0.2 ACU/clot in the drained plus washed clots.Plasminogen was also determined in drained and drained plus washed clots prepared from plasma with added purified plasminogen. The plasminogen was recovered in the washing fluid. According to these tests, then, purified added plasminogen is washed out of the clots.The plasminogen content of 20 thrombi obtained post mortem was also determined. The mean value was found to be 0.7 ACU/cm thrombus. Judging from our results, the “intrinsic clot lysis theory” is not the main mechanism of clot dissolution.


2010 ◽  
Vol 35 (4) ◽  
pp. 543-550 ◽  
Author(s):  
Wojciech Batko ◽  
Bartosz Przysucha

AbstractAssessment of several noise indicators are determined by the logarithmic mean <img src="/fulltext-image.asp?format=htmlnonpaginated&src=P42524002G141TV8_html\05_paper.gif" alt=""/>, from the sum of independent random resultsL1;L2; : : : ;Lnof the sound level, being under testing. The estimation of uncertainty of such averaging requires knowledge of probability distribution of the function form of their calculations. The developed solution, leading to the recurrent determination of the probability distribution function for the estimation of the mean value of noise levels and its variance, is shown in this paper.


2019 ◽  
Vol 15 (5) ◽  
pp. 493-499 ◽  
Author(s):  
Francesco Caridi ◽  
Santina Marguccio ◽  
Alberto Belvedere ◽  
Maurizio D`Agostino ◽  
Giovanna Belmusto

Background: In this article a comprehensive study was carried out for the determination of natural radioactivity in animal and vegetable food (meat, fish, milk and derivates, legumes, cereals and derivates, fruit, hortalizas, vegetables, vegetable oils) typical of different feeding regimes, for the age category higher than 17 years. Methods: A total of eighty-five samples of Italian origin, coming from large retailers during the years 2014, 2015 and 2016, were analyzed through HPGe gamma spectrometry. Results: The specific activity of 40K was investigated and its mean value was found to be: (106.3 ± 6.9) Bq/kg for bovine, swine and sheep meat; (116.5 ± 9.7) Bq/kg for fish; (52.9 ± 3.1) Bq/kg for milk and derivates; (271.9 ± 16.7) Bq/kg for legumes; (67.2 ± 4.7) Bq/kg for cereals and derivates; (52.7 ± 4.4) Bq/kg for fruit; (72.9 ± 5.6) Bq/kg for hortalizas; (83.9 ± 6.5) Bq/kg for vegetables; lower than the minimum detectable activity for vegetable oils. For animal food the highest mean 40K activity concentration was found in fish samples; for vegetable food the highest one was detected in legumes. Conclusion: The evaluation of dose levels due to the food ingestion typical of Mediterranean, Vegetarian and Vegan diets was performed. The annual effective dose was found to be 0.16 mSv/y, 0.41 mSv/y and 0.54 mSv/y, respectively.


Healthcare ◽  
2021 ◽  
Vol 9 (2) ◽  
pp. 117
Author(s):  
Massimiliano Esposito ◽  
Angelo Montana ◽  
Aldo Liberto ◽  
Veronica Filetti ◽  
Nunzio Di Nunno ◽  
...  

Anaphylaxis is a life-threatening or fatal clinical emergency characterized by rapid onset, and death may be sudden. The margin of certainty about the diagnosis of anaphylactic death is not well established. The application of immunohistochemical techniques combined with the evaluation of blood tryptase concentrations opened up a new field of investigation into anaphylactic death. The present study investigated eleven autopsy cases of anaphylactic death, carried out between 2005 and 2017, by the Departments of Forensic Pathology of the Universities of Foggia and Catania (Italy). An analysis of the medical records was carried out in all autopsies. Seven autopsies were carried out on males and four on females. Of the eleven cases, one showed a history of asthma, one of food ingestion, two of oral administration of medications, six did not refer any allergy history, and one subject was unknown. All cases (100%) showed pulmonary congestion and edema; 7/11 (64%) of the cases had pharyngeal/laryngeal edema and mucus plugging in the airway; only one case (9%) had a skin reaction that was found during external examination. Serum tryptase concentration was measured in ten cases, and the mean value was 133.5 µg/L ± 177.9. The immunohistochemical examination using an anti-tryptase antibody on samples from the lungs, pharynx/larynx, and skin site of medication injection showed that all cases (100%) were strongly immunopositive for anti-tryptase antibody staining on lung samples; three cases (30%) were strongly immunopositive for anti-tryptase antibody staining on pharyngeal/laryngeal samples; and eight cases (80%) were strongly immunopositive for anti-tryptase antibody staining on skin samples. We conclude that a typical clinical history, blood tryptase level >40 µg/L, and strongly positive anti-tryptase antibody staining in the immunohistochemical investigation may represent reliable parameters in the determination of anaphylactic death with the accuracy needed for forensic purposes.


2021 ◽  
Vol 80 (Suppl 1) ◽  
pp. 1083.2-1084
Author(s):  
O. Rusanova ◽  
A. Trofimenko ◽  
N. Emelyanov ◽  
O. Emelyanova

Background:Production of antibodies to ceruloplasmin (CP) in rheumatoid arthritis is an issue that has not been studied well enough. It was not by chance that this copper–containing alpha 2-glycorpoteid of blood plasma showing multienzymatic properties was chosen as an object of investigation. Data on the content and activity of CP in the blood of rheumatoid arthritis patients are contradictory, which has to do with different approaches to selection of patients and different measuring methods.Objectives:Improving diagnosis of rheumatoid arthritis by determination of antibodies to CP as well as its amount and enzymatic activity.Methods:We studied the serum from 30 apparently healthy individuals, and 108 rheumatoid arthritis patients. Antibodies to CP were determined by enzyme immunoassay using immobilized granulated antigen preparations (modification by Gontar et al, 2002). The amount of CP was determined by enzyme immunoassay according to the method of I.S. Kuzmina et al (1991) using commercial diagnostic agent manufactured by Mechnikov Research Institute for Vaccines and Sera.Results:Enzyme immunoassay showed a mean level of CP antibodies in donor sera of 0,020±0,006 optical density units. The level of normal values of specific antibodies determined as M±2σ included an extinction value in the range 0 – 0,086. The mean value of oxidase activity and the amount of CP in healthy people was 716±26,3 and 921±32 ng/ml, correspondingly. In the process of study we revealed a reliable increase in CP antibody count, the activity and amount of CP in patients with rheumatoid arthritis while in all cases the parameters under study correlated with the degree of disease activity (p<0,05): at activity degree I CP antibodies were 0,098±0,011; CP activity was 954±48,1; CP amount was 1292±73,4. At activity degree II CP antibodies were 0,138±0,007; CP activity was 1163±39,6; CP amount was 1763±69,3. At activity degree III, CP antibodies were 0,182±0,015; CP activity was 1368±89,5; CP amount was 1794±102,8. After a course of hospital treatment was completed, we noted a reliable decrease in the activity and amount of CP (at degree I of rheumatoid arthritis activity p<0,001, at degree II of rheumatoid arthritis activity p<0,01for both parameters; at degree III, p<0,05) compared with baseline findings. A decrease in CP antibodies shows decelerated dynamics, especially in patients with pronounced disease activity, which indicates severe disorders in the immunity that cannot be cured completely within 30 – 40 days of hospital treatment course.Conclusion:Determination of CP antibodies, as well as quantitative content of CP and its oxidase activity can serve as indicators of the activity of rheumatoid arthritis, as well as an accessory criterion of the effectiveness of administered therapy.Disclosure of Interests:None declared


1939 ◽  
Vol 29 (3) ◽  
pp. 427-462 ◽  
Author(s):  
Perry Byerly

Summary Least-squares adjustments of observations of waves of the P groups at central and southern California stations are used to obtain the speeds of various waves. Only observations made to tenths of a second are used. It is assumed that the waves have a common velocity for all earthquakes. But the time intercepts of the travel-time curves are allowed to be different for different shocks. The speed of P̄ is found to be 5.61 km/sec.±0.05. The speed for S̄ (founded on fewer data) is 3.26 km/sec. ± 0.09. There are slight differences in the epicenters located by the use of P̄ and S̄ which may or may not be significant. It is suggested that P̄ and S̄ may be released from different foci. The speed of Pn, the wave in the top of the mantle, is 8.02 km/sec. ± 0.05. Intermediate P waves of speeds 6.72 km/sec. ± 0.02 and 7.24 km/sec. ± 0.04 are observed. Only the former has a time intercept which allows a consistent computation of structure when considered a layer wave. For the Berkeley earthquake of March 8, 1937, the accurate determination of depth of focus was possible. This enabled a determination of layering of the earth's crust. The result was about 9 km. of granite over 23 km. of a medium of speed 6.72 km/sec. Underneath these two layers is the mantle of speed 8.02 km/sec. The data from other shocks centering south of Berkeley would not fit this structure, but an assumption of the thickening of the granite southerly brought all into agreement. The earthquakes discussed show a lag of Pn as it passes under the Sierra Nevada. This has been observed before. A reconsideration of the Pn data of the Nevada earthquake of December 20, 1932, together with the data mentioned above, leads to the conclusion that the root of the mountain mass projects into the mantle beneath the surface layers by an amount between 6 and 41 km.


1967 ◽  
Vol 56 (1) ◽  
pp. 99-106 ◽  
Author(s):  
K. Leybold ◽  
J. Rieper ◽  
L. Weissbecker

ABSTRACT A simple method for the determination of cortisol-binding capacity is described. For saturation of the cortisol-binding proteins, plasma samples are incubated with an excess of cortisol. In the next step NADPH and liver microsomes of female rats are added. The microsomal Δ4-3-ketosteroid hydrogenase only reduces non protein-bound cortisol to tetrahydrocortisol-5α. Then the steroids are extracted by dichloromethane, and after some purification steps analyzed by fluorometry. Tetrahydrocortisol gives practically no fluorescence. The cortisol determined by this method corresponds to protein-bound cortisol and indicates the extent of cortisolbinding capacity. Precision and accuracy of the method were found to be good. The values of cortisol-binding capacity obtained by our method are compared with the results of other authors. The mean value of adult men was 25.5 ± 3.4 μg/100 ml, that of pregnant women, mens IX-X, 42.3 ± 4.2 μg/100 ml.


2014 ◽  
Vol 955-959 ◽  
pp. 1204-1209
Author(s):  
Xiao Li ◽  
Xiao Man Li ◽  
Xiao Xia Yang ◽  
Qiang Li ◽  
Bin Huang ◽  
...  

An efficient and reliable analytical method has been used for determination of polybrominated diphenyl ethers (PBDEs) in atmospheric total suspended particles collected from the six state controlling air sampling sites and two self-selection sampling sites in Kunming, China. The results showed that the overall average concentrations of TSP collected from Kunming were in the range of 44.36 μg/m3 to 82.22 μg/m3. This pattern was lower than the average concentrations of Guiyu, Guangzhou and similar to Hong Kong. In TSP, the penta-BDEs and octa-BDEs were the dominant PBDEs and the PBDEs concentration ranged from 12.39 pg/m3 to 71.51 pg/m3, with a mean value of 46.82 pg/m3. This level was below the city of Guiyu, Örebro in Sweden and similar to Hong Kong, Guangzhou. The average concentrations of PBDEs had the trend of descent from the urban center to the outskirts of Kunming.


(GE/m**3). According to this definition one odour unit is the amount of odorants in one cubic meter of air at odour thres­ hold level. The new definition is a real concentration and gives a better form of input parameter for dispersion models. On the basis of guideline VDI 3881 parts 1, 2, and 3 ringtests were carried out with different odorants. The results can be summerized as follows: -The dispersion of results varies and depends on the compo­ sition of the participants and on problems of sampling and preparation of odorous sample. Lower dispersion is obtained when results with obvious errors in application of guide­ lines or with large deviations from mean value are excluded. -Participants of the Netherlands get systematically lower threshold values than the others. The reason has to be investigated. -All findings of the ringtests lead to the conclusion that it is possible to determine odour thresholds which do not differ by more than factor 10. At present another ringtest is in preparation. This test will be carried out in summer 1985. The French collegues will also participate in this test. Experience of all ringtests will be reported in part 4 of guideline VDI 3881. Guideline VDI 3882 deals with the determination of odour intensity and hedonic tone. The members of the working group "odorous substances" assume that odour threshold and odour concentration are insufficient for the characterization of odorous perception. They recommend to judge the odour inten­ sity and the hedonic tone by category estimation. Moreover, it is their opinion that the odour determination with olfacto­ meters is not suitable to assess odour in ambient air. There­ fore they are preparing two guidelines dealing with these problems. Guideline VDI 3883 gives instructions on the regis­ tration of nuisance by interviews with nearby residents of emitting plants or inhabitants of industrial areas. Addition­ ally guideline VDI 3940 describes the determination of odour in ambient air by inspection panels based on the following idea: During constant conditions as to the class of weather, wind speed, and wind direction each local point is charac­ terized by a frequency of odour perception representing the probability to perceive an odour. The situation at a local point will be have to determine the portion of a year with a frequency of odorous perception greater than 5 % in a random test. Both guidelines, VDI 3882 and 3940, should give corres­ ponding results. Guideline VDI 3781 part 5 completes the complex of odour determination and judgement with the calculation of disper­ sion models. The calculation methode and odour determination by panelists should give comparable results. The following summery can be given. Odour measurements with olfactometers is only a small part of the whole field of odour determination in ambient air and the measurement of odour nuisance must be approached in the near future with appropriate urgency.


Sign in / Sign up

Export Citation Format

Share Document