Reply to A. Roy and A. Apparao by author

Geophysics ◽  
1978 ◽  
Vol 43 (6) ◽  
pp. 1276-1276
Author(s):  
L. S. Edwards

The calculation of absolute effective depth for any finite, realizable array can be based on the total array length L or on any other spacing factor desired. The burden of the discussion by Roy and Apparao is that the distance a between the active electrodes is the natural spacing factor for the 2‐pole array. I agree entirely with this, as evidenced by my statement that “the absolute effective depth is almost directly proportional to a”, and by my inclusion of [Formula: see text] coefficients in the first column of Table 2. I would consider the factors of this column to be the natural units for depth calculations for all arrays (except for the Schlumberger and gradient arrays, where L or the conventional L/2 is more suitable).

2021 ◽  
Vol 11 ◽  
Author(s):  
Jianping Zhang ◽  
Lin Wang ◽  
Benhua Xu ◽  
Miaoyun Huang ◽  
Yuangui Chen ◽  
...  

Background and PurposeThis study aimed to quantify the differences between pre- and post-contrast agent (CA) CT for CyberKnife brain SRS plans.Materials and MethodsTwenty-five patients were retrospectively analyzed. They were divided into two categories, inhomogeneous cases (13 patients) and homogeneous cases (12 patients), according to whether the tumor was close to the cavity and inhomogeneous tissues or not. The pre-CA and post-CA plans were designed and calculated using the same monitor unit and paths as those in the ray-tracing algorithm, respectively.ResultsThe CT number difference of tumor between pre- and post-CA was significant (on average, 24.78 ± 18.56 HU, P-value < 0.01). The deviation value of the target was the largest at approximately 37 HU (inhomo-) and 13 HU (homo-) (P < 0.01), and the values of the organs at risk (OARs) were not statistically significant (P-value > 0.05). However, it was not statistically significant for the dose difference between the two groups with the injection of CA (P-value > 0.05). The absolute effective depth difference generally remained at a level of 1 mm, but the dose difference was quitely fluctuated sometimes more than 20%. The absolute effective depth difference of the inhomo-case (0.62 mm) was larger than that of the homo-case (0.37 mm) on median, as well as the variation amplitude (P-value < 0.05). Moreover, the relative dose differences between the two cases were 0.38% (inhomo-) and 0.2% (homo-), respectively (P-value < 0.05). At the criterion of 1 mm/1%, the gamma pass rate of the homo-case (95.89%) was larger than that of the inhomo-case (93.79%). For the OARs, except for the cochlea, the two cases were almost the same (>98.85%). The tumor control probability of the target was over 99.99% before and after injection of a CA, as well as the results for the homo-case and inhomo-case.ConclusionsConsidering the difference of evaluation indexes between pre- and post-CA images, we recommended plain CT to be employed as the primary image for improving the CK treatment accuracy of brain SRS, especially when the target was close to CA-sensitive OARs and cavity.


Author(s):  
P. Echlin ◽  
M. McKoon ◽  
E.S. Taylor ◽  
C.E. Thomas ◽  
K.L. Maloney ◽  
...  

Although sections of frozen salt solutions have been used as standards for x-ray microanalysis, such solutions are less useful when analysed in the bulk form. They are poor thermal and electrical conductors and severe phase separation occurs during the cooling process. Following a suggestion by Whitecross et al we have made up a series of salt solutions containing a small amount of graphite to improve the sample conductivity. In addition, we have incorporated a polymer to ensure the formation of microcrystalline ice and a consequent homogenity of salt dispersion within the frozen matrix. The mixtures have been used to standardize the analytical procedures applied to frozen hydrated bulk specimens based on the peak/background analytical method and to measure the absolute concentration of elements in developing roots.


Author(s):  
C. M. Payne ◽  
P. M. Tennican

In the normal peripheral circulation there exists a sub-population of lymphocytes which is ultrastructurally distinct. This lymphocyte is identified under the electron microscope by the presence of cytoplasmic microtubular-like inclusions called parallel tubular arrays (PTA) (Figure 1), and contains Fc-receptors for cytophilic antibody. In this study, lymphocytes containing PTA (PTA-lymphocytes) were quantitated from serial peripheral blood specimens obtained from two patients with Epstein -Barr Virus mononucleosis and two patients with cytomegalovirus mononucleosis. This data was then correlated with the clinical state of the patient.It was determined that both the percentage and absolute number of PTA- lymphocytes was highest during the acute phase of the illness. In follow-up specimens, three of the four patients' absolute lymphocyte count fell to within normal limits before the absolute PTA-lymphocyte count.In one patient who was followed for almost a year, the absolute PTA- lymphocyte count was consistently elevated (Figure 2). The estimation of absolute PTA-lymphocyte counts was determined to be valid after a morphometric analysis of the cellular areas occupied by PTA during the acute and convalescent phases of the disease revealed no statistical differences.


Author(s):  
Stuart McKernan ◽  
C. Barry Carter

The determination of the absolute polarity of a polar material is often crucial to the understanding of the defects which occur in such materials. Several methods exist by which this determination may be performed. In bulk, single-domain specimens, macroscopic techniques may be used, such as the different etching behavior, using the appropriate etchant, of surfaces with opposite polarity. X-ray measurements under conditions where Friedel’s law (which means that the intensity of reflections from planes of opposite polarity are indistinguishable) breaks down can also be used to determine the absolute polarity of bulk, single-domain specimens. On the microscopic scale, and particularly where antiphase boundaries (APBs), which separate regions of opposite polarity exist, electron microscopic techniques must be employed. Two techniques are commonly practised; the first [1], involves the dynamical interaction of hoLz lines which interfere constructively or destructively with the zero order reflection, depending on the crystal polarity. The crystal polarity can therefore be directly deduced from the relative intensity of these interactions.


2005 ◽  
Vol 173 (4S) ◽  
pp. 140-141
Author(s):  
Mariana Lima ◽  
Celso D. Ramos ◽  
Sérgio Q. Brunetto ◽  
Marcelo Lopes de Lima ◽  
Carla R.M. Sansana ◽  
...  

Methodology ◽  
2008 ◽  
Vol 4 (3) ◽  
pp. 132-138 ◽  
Author(s):  
Michael Höfler

A standardized index for effect intensity, the translocation relative to range (TRR), is discussed. TRR is defined as the difference between the expectations of an outcome under two conditions (the absolute increment) divided by the maximum possible amount for that difference. TRR measures the shift caused by a factor relative to the maximum possible magnitude of that shift. For binary outcomes, TRR simply equals the risk difference, also known as the inverse number needed to treat. TRR ranges from –1 to 1 but is – unlike a correlation coefficient – a measure for effect intensity, because it does not rely on variance parameters in a certain population as do effect size measures (e.g., correlations, Cohen’s d). However, the use of TRR is restricted on outcomes with fixed and meaningful endpoints given, for instance, for meaningful psychological questionnaires or Likert scales. The use of TRR vs. Cohen’s d is illustrated with three examples from Psychological Science 2006 (issues 5 through 8). It is argued that, whenever TRR applies, it should complement Cohen’s d to avoid the problems related to the latter. In any case, the absolute increment should complement d.


1980 ◽  
Vol 41 (C1) ◽  
pp. C1-109-C1-110
Author(s):  
V. N. Belogurov ◽  
V. A. Bilinkin
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document