Hardness–Yield Strength Relationships in Al-Zn-Mg(-Cu) Alloys

Author(s):  
Murat Tiryakioğlu

Mean pressure developed during Vickers and Rockwell hardness testing of Al-Zn-MgCualloys is reviewed. Relationships between mean pressure and yield strength are introduced for these alloys by using both Vickers and Rockwell hardness data from the literature. Results have shown that the slope of the mean pressure–yield strength relationships is 0.355 for Vickers tests and 0.264 for Rockwell B tests. The y-intercepts calculated for best fits are all negative, implying that the representative strains in both tests have exceeded the yield strain. Results also have indicated that mean pressure is affected by the indenter geometry and therefore is not a universal hardness number.

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
K Piayda ◽  
A Wimmer ◽  
H Sievert ◽  
K Hellhammer ◽  
S Afzal ◽  
...  

Abstract Background In the era of transcatheter aortic valve replacement (TAVR), there is renewed interest in percutaneous balloon aortic valvuloplasty (BAV), which may qualify as the primary treatment option of choice in special clinical situations. Success of BAV is commonly defined as a significant mean pressure gradient reduction after the procedure. Purpose To evaluate the correlation of the mean pressure gradient reduction and increase in the aortic valve area (AVA) in different flow and gradient patterns of severe aortic stenosis (AS). Methods Consecutive patients from 01/2010 to 03/2018 undergoing BAV were divided into normal-flow high-gradient (NFHG), low-flow low-gradient (LFLG) and paradoxical low-flow low-gradient (pLFLG) AS. Baseline characteristics, hemodynamic and clinical information were collected and compared. Additionally, the clinical pathway of patients (BAV as a stand-alone procedure or BAV as a bridge to aortic valve replacement) was followed-up. Results One-hundred-fifty-six patients were grouped into NFHG (n=68, 43.5%), LFLG (n=68, 43.5%) and pLFLG (n=20, 12.8%) AS. Underlying reasons for BAV and not TAVR/SAVR as the primary treatment option are displayed in Figure 1. Spearman correlation revealed that the mean pressure gradient reduction had a moderate correlation with the increase in the AVA in patients with NFHG AS (r: 0.529, p<0.001) but showed no association in patients with LFLG (r: 0.145, p=0.239) and pLFLG (r: 0.030, p=0.889) AS. Underlying reasons for patients to undergo BAV and not TAVR/SAVR varied between groups, however cardiogenic shock or refractory heart failure (overall 46.8%) were the most common ones. After the procedure, independent of the hemodynamic AS entity, patients showed a functional improvement, represented by substantially lower NYHA class levels (p<0.001), lower NT-pro BNP levels (p=0.003) and a numerical but non-significant improvement in other echocardiographic parameters like the left ventricular ejection fraction (p=0.163) and tricuspid annular plane systolic excursion (TAPSE, p=0.066). An unplanned cardiac re-admission due to heart failure was necessary in 23.7% patients. Less than half of the patients (44.2%) received BAV as a bridge to TAVR/SAVR (median time to bridge 64 days). Survival was significantly increased in patients having BAV as a staged procedure (log-rank p<0.001). Conclusion In daily clinical practice, the mean pressure gradient reduction might be an adequate surrogate of BAV success in patients with NFHG AS but is not suitable for patients with other hemodynamic entities of AS. In those patients, TTE should be directly performed in the catheter laboratory to correctly assess the increase of the AVA. BAV as a staged procedure in selected clinical scenarios increases survival and is a considerable option in all flow states of severe AS. (NCT04053192) Figure 1 Funding Acknowledgement Type of funding source: None


2021 ◽  
Vol 5 (7) ◽  
pp. 179
Author(s):  
Brice Taillet ◽  
René Pailler ◽  
Francis Teyssandier

Ceramic matrix composites (CMCs) have been prepared and optimized as already described in part I of this paper. The fibrous preform made of Hi-Nicalon S fibers was densified by a matrix composed of Si2N2O prepared inside the CMC by reacting a mixture of Si and SiO2 under high nitrogen pressure. This part describes the oxidation resistance and mechanical properties of the optimized CMC. The CMC submitted to oxidation in wet oxygen at 1400 °C for 170 h exhibited an oxidation gradient from the surface to almost the center of the sample. In the outer part of the sample, Si2N2O, Si3N4 and SiC were oxidized into silica in the cristobalite-crystallized form. The matrix microstructure looks similar to the original one at the center of the sample, while at the surface large pores are observed and the fiber/matrix interphase is consumed by oxidation. The elastic modulus and the hardness measured at room temperature by nano-indentation are, respectively, 100 and 8 GPa. The elastic modulus measured at room temperature by tensile tests ranges from 150 to 160 GPa and the ultimate yield strength from 320 to 390 MPa, which corresponds to a yield strain of about 0.6%. The yield strength identified by acoustic emission is about 40 MPa.


2021 ◽  
Vol 904 ◽  
pp. 117-123
Author(s):  
Yi Cui ◽  
Yun Fei Zhang ◽  
Yan Guang Han ◽  
Da Lv

The effect of high temperature annealing on microstructure evolution of Ni-24Fe-14Cr-8Mo alloy was investigated through Optical Microscopy (OM), Scanning Electron Microscopy (SEM), X-Ray Diffraction (XRD) and Rockwell Hardness Testing Machine. Three kinds of grain growth patterns were found at different annealing temperatures due to carbides precipitation and dissolution. After a combination of high temperature annealing and aging treatment, the hardness versus time curves performed a parabolic pattern. The highest hardness was achieved under 1070°C/60 minutes treatment, and the desirable annealing time should be 60 minutes to 90 minutes.


1993 ◽  
Vol 75 (1) ◽  
pp. 148-154 ◽  
Author(s):  
S. Isono ◽  
D. L. Morrison ◽  
S. H. Launois ◽  
T. R. Feroah ◽  
W. A. Whitelaw ◽  
...  

The static mechanics of the hypotonic pharynx were endoscopically evaluated in nine sleeping patients with obstructive sleep apnea, having a primary narrowing only at the velopharynx. The velopharynx closed completely at a mean pressure of 0.18 +/- 1.21 cmH2O, and the mean half-dilation pressure was 1.93 cmH2O above closing pressure. The dependence of area on pressure was distinctly curvilinear, being steep near closing pressure and asymptotically approaching maximum area (mean = 1.32 cm2). The data for each patient were satisfactorily fitted by an exponential function (mean R2 = 0.98), and a single exponential relationship usefully represented the dependence of relative area on pressure above closing pressure for the population (R2 = 0.85). During the test inspiration, flow limitation was consistently observed when mask pressure exceeded closing pressure by 0.5–3.0 cmH2O. In summary, the static mechanics of the hypotonic velopharynx of patients with obstructive sleep apnea can be described by an exponential pressure-area relationship, with a closing pressure near atmospheric pressure and a high compliance in the range of airway pressure 0–3 cmH2O above closing pressure.


1977 ◽  
Vol 99 (3) ◽  
pp. 503-509 ◽  
Author(s):  
B. E. Lee ◽  
B. F. Soliman

A study has been made of the influence of grouping parameters on the mean pressure distributions experienced by three dimensional bluff bodies immersed in a turbulent boundary layer. The range of variable parameters has included group density, group pattern and incident flow type and direction for a simple cuboid element form. The three flow regimes associated with increasing group density are reflected in both the mean drag forces acting on the body and their associated pressure distributions. A comparison of both pressure distributions and velocity profile parameters with established work on two dimensional bodies shows close agreement in identifying these flow regime changes. It is considered that the application of these results may enhance our understanding of some common flow phenomena, including turbulent flow over rough surfaces, building ventilation studies and environmental wind around buildings.


2014 ◽  
Vol 577 ◽  
pp. 81-85
Author(s):  
Jing Wei Zhang ◽  
Jun Cai ◽  
Shuang Jiang ◽  
Xin Guo ◽  
Qiao Zhi Sun ◽  
...  

The effect of the different sizes and densities of He bubble on the mechanical properties of CLAM alloy was studied by milt-scale simulation method. It is found that with the increasing of helium bubble size and density, the yield strength and yield strain of CLAM alloys reduced, and the yield strength and yield elongation are predicted to be consistent with the experimental results.


2005 ◽  
Vol 26 (6) ◽  
pp. 442-448 ◽  
Author(s):  
Craig I. Title ◽  
Hung-Geun Jung ◽  
Brent G. Parks ◽  
Lew C. Schon

Background: The goal of this study was to identify pressure changes throughout the peroneal groove after a groove deepening procedure. We hypothesized that pressures would decrease. Methods: Twelve fresh-frozen foot and ankle specimens were used. A thin pressure strip containing four sensor pads was secured within the peroneal groove with pads 1 through 4 positioned at the calcaneofibular ligament (CFL) and at the distal, middle, and proximal groove, respectively. The midstance phase of gait was simulated with loads applied to the plantar foot and posterior tibial tendon and to the peroneus longus and brevis tendons. Pressures were recorded with the ankle in neutral, plantarflexion, dorsiflexion, inversion, and eversion. Groove deepening was done by osteotomizing the posterior fibular wall. Pressure readings were then recorded. Average pressures for each of the four sensor pads after the procedure were compared to those obtained before the procedure. Results: The mean pressure overlying the CFL increased at all five ankle positions; however, these changes were not significant. Significant decreases in pressure were noted within the distal and middle groove at all ankle positions after the peroneal groove deepening procedure. Pressure within the proximal groove increased at all but one position, with a significant difference noted in neutral and plantarflexion. Conclusion: Pressures within the middle and distal peroneal groove significantly decreased after a groove deepening procedure. Combining this technique with peroneal tendon debridement may be advantageous for treatment of partial peroneal tendon tears or recalcitrant peroneal tendinitis.


1953 ◽  
Vol 20 (1) ◽  
pp. 109-114
Author(s):  
S. I. Pai

Abstract The Reynolds equations of motion of turbulent flow of incompressible fluid have been studied for turbulent flow between parallel plates. The number of these equations is finally reduced to two. One of these consists of mean velocity and correlation between transverse and longitudinal turbulent-velocity fluctuations u 1 ′ u 2 ′ ¯ only. The other consists of the mean pressure and transverse turbulent-velocity intensity. Some conclusions about the mean pressure distribution and turbulent fluctuations are drawn. These equations are applied to two special cases: One is Poiseuille flow in which both plates are at rest and the other is Couette flow in which one plate is at rest and the other is moving with constant velocity. The mean velocity distribution and the correlation u 1 ′ u 2 ′ ¯ can be expressed in a form of polynomial of the co-ordinate in the direction perpendicular to the plates, with the ratio of shearing stress on the plate to that of the corresponding laminar flow of the same maximum velocity as a parameter. These expressions hold true all the way across the plates, i.e., both the turbulent region and viscous layer including the laminar sublayer. These expressions for Poiseuille flow have been checked with experimental data of Laufer fairly well. It also shows that the logarithmic mean velocity distribution is not a rigorous solution of Reynolds equations.


Sign in / Sign up

Export Citation Format

Share Document