scholarly journals Soft-tissue vibration and damping response to footwear changes across a wide range of anthropometrics in running

PLoS ONE ◽  
2021 ◽  
Vol 16 (8) ◽  
pp. e0256296
Author(s):  
Anja-Verena Behling ◽  
Marlene Giandolini ◽  
Vinzenz von Tscharner ◽  
Benno Maurus Nigg

Different factors were shown to alter the vibration characteristics of soft-tissue compartments during running. Changing pre-heel strike muscle activation or changing footwear conditions represents two possibilities to influence the vibration response via frequency shift or altered damping. Associated with the study of muscle pre-tuning is the difficulty in quantifying clean experimental data for the acceleration of soft-tissue compartments and muscle activities in heterogeneous populations. The purpose of this study was to determine the vibration and pre-tuning response to footwear across a wide range of participants during running and establish and describe groups formed according to the damping coefficient. 32 subjects were used for further analysis. The subjects ran at a self-selected speed (5 min) on a treadmill in two different shoes (soft & hard), while soft-tissue accelerations and muscle activation at the gastrocnemius medialis were quantified. Damping coefficients, total muscle intensity and dominant vibration frequencies were determined. Anthropometrics and skinfold measurements of the lower limbs were obtained. According to the damping coefficient response to the footwear intervention, three groups were formed, with most runners (n = 20) showing less damping in the hard shoe. Total muscle intensity, anthropometrics, and dominant vibration frequency across footwear were not different for these three groups. Most runners (84.4%) used the strategy of adjusting the damping coefficients significantly when switching footwear. Despite damping being the preferred adjustment to changes in footwear, muscle pre-tuning might not be the only mechanism to influence damping as previously suggested. Future studies should focus on the subject-specific composition of soft-tissue compartments to elucidate their contribution to vibrations.

2006 ◽  
Vol 129 (4) ◽  
pp. 594-602 ◽  
Author(s):  
Katherine A. Boyer ◽  
Benno M. Nigg

Electromyographic (EMG) activity is associated with several tasks prior to landing in walking and running including positioning the leg, developing joint stiffness and possibly control of soft tissue compartment vibrations. The concept of muscle tuning suggests one reason for changes in muscle activity pattern in response to small changes in impact conditions, if the frequency content of the impact is close to the natural frequency of the soft tissue compartments, is to minimize the magnitude of soft tissue compartment vibrations. The mechanical properties of the soft tissue compartments depend in part on muscle activations and thus it was hypothesized that changes in the muscle activation pattern associated with different impact conditions would result in a change in the acceleration transmissibility to the soft tissue compartments. A pendulum apparatus was used to systematically administer impacts to the heel of shod male participants. Wall reaction forces, EMG of selected leg muscles, soft tissue compartment and shoe heel cup accelerations were quantified for two different impact conditions. The transmissibility of the impact acceleration to the soft tissue compartments was determined for each subject/soft tissue compartment/shoe combination. For this controlled impact situation it was shown that changes in the damping properties of the soft tissue compartments were related to changes in the EMG intensity and/or mean frequency of related muscles in response to a change in the impact interface conditions. These results provide support for the muscle tuning idea—that one reason for the changes in muscle activity in response to small changes in the impact conditions may be to minimize vibrations of the soft tissue compartments that are initiated at heel-strike.


2019 ◽  
Vol 67 (1) ◽  
pp. 25-35
Author(s):  
Shen Zhang ◽  
Weijie Fu ◽  
Yu Liu

AbstractWe aimed to explore the biomechanical differences between the anticipated drop jump and unanticipated drop landing. Twelve male collegiate basketball players completed an anticipated drop jump and unanticipated drop landing with double legs from a height of 30 cm. Kinematics, impact force, soft tissue vibrations, and electromyographic (EMG) amplitudes of the dominant leg were collected simultaneously. The anticipated drop jump showed more flexed lower limbs during landing and increased range of motion compared to the unanticipated drop landing. The anticipated drop jump also had lower impact force, lesser soft tissue vibration, and a greater damp coefficient at the thigh muscles compared with the unanticipated drop landing. Significant increases in the EMG amplitudes of the tibialis anterior, lateral gastrocnemius, rectus femoris, and biceps femoris were observed in the anticipated drop jump during the pre/post-activation and downward phases. The anticipated drop jump presented more optimized landing posture control with more joint flexion, lower impact force, less soft tissue vibrations, and full preparation of muscle activations compared with the unanticipated drop landing.


1985 ◽  
Vol 26 (6) ◽  
pp. 727-730 ◽  
Author(s):  
E. Seem ◽  
E. Stranden ◽  
M. G. Stiris

Computed tomography was used in 12 patients to investigate the distribution of oedema in the soft tissue compartments of lower limbs with deep venous thrombosis. Oedema was evenly distributed throughout the subcutis and the muscular compartments in tomograms obtained 25 cm proximal to the ankle. Significantly less swelling in the muscular compartments was found 10 cm proximal to the ankle. Interstitial fluid hydrostatic pressure was measured in the subcutis, and in anterior and posterior muscular compartments, and was significantly increased in all cases. Except for one case, the recorded pressures were well below 30 mmHg, which is considered the limit above which compartment syndromes occur. Tissue compliance was significantly lower in muscular compartments than in the subcutis.


2010 ◽  
Vol 07 (03) ◽  
pp. 243-257 ◽  
Author(s):  
Y. C. MAO

The shock wave of ground reaction forces during walking and running is suggested as a primary etiological agent in some conditions, such as degenerative joint disease, prosthetic joint loosening, plantar fasciitis or muscle tears. This study proposes a novel shock absorber design with an adjustable automatic smooth tuning range of the damping coefficient and rapid rebounds after impact loads, equipped in the above-knee prosthesis tibia section without any electronic devices. This absorber is also capable of automatic locking-out and releasing for stance and heel-strike phases without manual switching. It absorbs the impact load of the ground reaction force at each heel strike and adapts itself to the input force speed, feasible for patients to tolerate a wide range of athletic and inert situations. This study constructs a high order nonlinear dynamic model for its pressure-sensitive plunger and check valve systems and considers the cavitation phenomenon during speedy fluid flows. Simulation results show that both the damper resistant force and the damping coefficient reduce as the ground reaction force velocity increases, providing a desirable tendency of diminishing shock wave influences on the biological musculoskeletal system.


1991 ◽  
Vol 30 (01) ◽  
pp. 35-39 ◽  
Author(s):  
H. S. Durak ◽  
M. Kitapgi ◽  
B. E. Caner ◽  
R. Senekowitsch ◽  
M. T. Ercan

Vitamin K4 was labelled with 99mTc with an efficiency higher than 97%. The compound was stable up to 24 h at room temperature, and its biodistribution in NMRI mice indicated its in vivo stability. Blood radioactivity levels were high over a wide range. 10% of the injected activity remained in blood after 24 h. Excretion was mostly via kidneys. Only the liver and kidneys concentrated appreciable amounts of radioactivity. Testis/soft tissue ratios were 1.4 and 1.57 at 6 and 24 h, respectively. Testis/blood ratios were lower than 1. In vitro studies with mouse blood indicated that 33.9 ±9.6% of the radioactivity was associated with RBCs; it was washed out almost completely with saline. Protein binding was 28.7 ±6.3% as determined by TCA precipitation. Blood clearance of 99mTc-l<4 in normal subjects showed a slow decrease of radioactivity, reaching a plateau after 16 h at 20% of the injected activity. In scintigraphic images in men the testes could be well visualized. The right/left testis ratio was 1.08 ±0.13. Testis/soft tissue and testis/blood activity ratios were highest at 3 h. These ratios were higher than those obtained with pertechnetate at 20 min post injection.99mTc-l<4 appears to be a promising radiopharmaceutical for the scintigraphic visualization of testes.


2021 ◽  
Vol 6 (1) ◽  
pp. 16
Author(s):  
Kara B. Bellenfant ◽  
Gracie L. Robbins ◽  
Rebecca R. Rogers ◽  
Thomas J. Kopec ◽  
Christopher G. Ballmann

The purpose of this study was to investigate the effects of how limb dominance and joint immobilization alter markers of physical demand and muscle activation during ambulation with axillary crutches. In a crossover, counterbalanced study design, physically active females completed ambulation trials with three conditions: (1) bipedal walking (BW), (2) axillary crutch ambulation with their dominant limb (DOM), and (3) axillary crutch ambulation with their nondominant limb (NDOM). During the axillary crutch ambulation conditions, the non-weight-bearing knee joint was immobilized at a 30-degree flexion angle with a postoperative knee stabilizer. For each trial/condition, participants ambulated at 0.6, 0.8, and 1.0 mph for five minutes at each speed. Heart rate (HR) and rate of perceived exertion (RPE) were monitored throughout. Surface electromyography (sEMG) was used to record muscle activation of the medial gastrocnemius (MG), soleus (SOL), and tibialis anterior (TA) unilaterally on the weight-bearing limb. Biceps brachii (BB) and triceps brachii (TB) sEMG were measured bilaterally. sEMG signals for each immobilization condition were normalized to corresponding values for BW.HR (p < 0.001) and RPE (p < 0.001) were significantly higher for both the DOM and NDOM conditions compared to BW but no differences existed between the DOM and NDOM conditions (p > 0.05). No differences in lower limb muscle activation were noted for any muscles between the DOM and NDOM conditions (p > 0.05). Regardless of condition, BB activation ipsilateral to the ambulating limb was significantly lower during 0.6 mph (p = 0.005) and 0.8 mph (p = 0.016) compared to the same speeds for BB on the contralateral side. Contralateral TB activation was significantly higher during 0.6 mph compared to 0.8 mph (p = 0.009) and 1.0 mph (p = 0.029) irrespective of condition. In conclusion, limb dominance appears to not alter lower limb muscle activation and walking intensity while using axillary crutches. However, upper limb muscle activation was asymmetrical during axillary crutch use and largely dependent on speed. These results suggest that functional asymmetry may exist in upper limbs but not lower limbs during assistive device supported ambulation.


Arthroplasty ◽  
2021 ◽  
Vol 3 (1) ◽  
Author(s):  
Toni Wendler ◽  
Torsten Prietzel ◽  
Robert Möbius ◽  
Jean-Pierre Fischer ◽  
Andreas Roth ◽  
...  

Abstract Background All current total hip arthroplasty (THA) systems are modular in design. Only during the operation femoral head and stem get connected by a Morse taper junction. The junction is realized by hammer blows from the surgeon. Decisive for the junction strength is the maximum force acting once in the direction of the neck axis, which is mainly influenced by the applied impulse and surrounding soft tissues. This leads to large differences in assembly forces between the surgeries. This study aimed to quantify the assembly forces of different surgeons under influence of surrounding soft tissue. Methods First, a measuring system, consisting of a prosthesis and a hammer, was developed. Both components are equipped with a piezoelectric force sensor. Initially, in situ experiments on human cadavers were carried out using this system in order to determine the actual assembly forces and to characterize the influence of human soft tissues. Afterwards, an in vitro model in the form of an artificial femur (Sawbones Europe AB, Malmo, Sweden) with implanted measuring stem embedded in gelatine was developed. The gelatine mixture was chosen in such a way that assembly forces applied to the model corresponded to those in situ. A study involving 31 surgeons was carried out on the aforementioned in vitro model, in which the assembly forces were determined. Results A model was developed, with the influence of human soft tissues being taken into account. The assembly forces measured on the in vitro model were, on average, 2037.2 N ± 724.9 N, ranging from 822.5 N to 3835.2 N. The comparison among the surgeons showed no significant differences in sex (P = 0.09), work experience (P = 0.71) and number of THAs performed per year (P = 0.69). Conclusions All measured assembly forces were below 4 kN, which is recommended in the literature. This could lead to increased corrosion following fretting in the head-neck interface. In addition, there was a very wide range of assembly forces among the surgeons, although other influencing factors such as different implant sizes or materials were not taken into account. To ensure optimal assembly force, the impaction should be standardized, e.g., by using an appropriate surgical instrument.


2021 ◽  
Vol 2 ◽  
Author(s):  
Rand Hidayah ◽  
Dongbao Sui ◽  
Kennedi A. Wade ◽  
Biing-Chwen Chang ◽  
Sunil Agrawal

Abstract Passive wearable exoskeletons are desirable as they can provide assistance during user movements while still maintaining a simple and low-profile design. These can be useful in industrial tasks where an ergonomic device could aid in load lifting without inconveniencing them and reducing fatigue and stress in the lower limbs. The SpringExo is a coil-spring design that aids in knee extension. In this paper, we describe the muscle activation of the knee flexors and extensors from seven healthy participants during repeated squats. The outcome measures are the timings of the key events during squat, flexion angle, muscle activation of rectus femoris and bicep femoris, and foot pressure characteristics of the participants. These outcome measures assess the possible effects of the device during lifting operations where reduced effort in the muscles is desired during ascent phase of the squat, without changing the knee and foot kinematics. The results show that the SpringExo significantly decreased rectus femoris activation during ascent (−2%) without significantly affecting either the bicep femoris or rectus femoris muscle activations in descent. This implies that the user could perform a descent without added effort and ascent with reduced effort. The exoskeleton showed other effects on the biomechanics of the user, increasing average squat time (+0.02 s) and maximum squat time (+0.1 s), and decreasing average knee flexion angle (−4°). The exoskeleton has no effect on foot loading or placement, that is, the user did not have to revise their stance while using the device.


Author(s):  
Ross M. Neuman ◽  
Staci M. Shearin ◽  
Karen J. McCain ◽  
Nicholas P. Fey

Abstract Background Gait impairment is a common complication of multiple sclerosis (MS). Gait limitations such as limited hip flexion, foot drop, and knee hyperextension often require external devices like crutches, canes, and orthoses. The effects of mobility-assistive technologies (MATs) prescribed to people with MS are not well understood, and current devices do not cater to the specific needs of these individuals. To address this, a passive unilateral hip flexion-assisting orthosis (HFO) was developed that uses resistance bands spanning the hip joint to redirect energy in the gait cycle. The purpose of this study was to investigate the short-term effects of the HFO on gait mechanics and muscle activation for people with and without MS. We hypothesized that (1) hip flexion would increase in the limb wearing the device, and (2) that muscle activity would increase in hip extensors, and decrease in hip flexors and plantar flexors. Methods Five healthy subjects and five subjects with MS walked for minute-long sessions with the device using three different levels of band stiffness. We analyzed peak hip flexion and extension angles, lower limb joint work, and muscle activity in eight muscles on the lower limbs and trunk. Single-subjects analysis was used due to inter-subject variability. Results For subjects with MS, the HFO caused an increase in peak hip flexion angle and a decrease in peak hip extension angle, confirming our first hypothesis. Healthy subjects showed less pronounced kinematic changes when using the device. Power generated at the hip was increased in most subjects while using the HFO. The second hypothesis was not confirmed, as muscle activity showed inconsistent results, however several subjects demonstrated increased hip extensor and trunk muscle activity with the HFO. Conclusions This exploratory study showed that the HFO was well-tolerated by healthy subjects and subjects with MS, and that it promoted more normative kinematics at the hip for those with MS. Future studies with longer exposure to the HFO and personalized assistance parameters are needed to understand the efficacy of the HFO for mobility assistance and rehabilitation for people with MS.


2006 ◽  
Vol 21 (4) ◽  
pp. 168-179 ◽  
Author(s):  
A Cavezzi ◽  
N Labropoulos ◽  
H Partsch ◽  
S Ricci ◽  
A Caggiati ◽  
...  

Objectives: Duplex ultrasound investigation has become the reference standard in assessing the morphology and haemodynamics of the lower limb veins. The project described in this paper was an initiative of the Union Internationale de Phlébologie (UIP). The aim was to obtain a consensus of international experts on the methodology to be used for assessment of the anatomy of superficial and perforating veins in the lower limb by ultrasound imaging. Design: Consensus conference leading to a consensus document. Methods: The authors performed a systematic review of the published literature on duplex anatomy of the superficial and perforating veins of the lower limbs. Afterwards, they invited a group of experts from a wide range of countries to participate in this project. Electronic submissions from the authors and the experts (text and images) were made available to all participants via the UIP website. The authors prepared a draft document for discussion at the UIP Chapter meeting held in San Diego, USA, in August 2003. Following this meeting, a revised manuscript was circulated to all participants and further comments were received by the authors and included in subsequent versions of the manuscript. Eventually, all participants agreed on the final version of the paper. Results: The experts have made detailed recommendations concerning the methods to be used for duplex ultrasound examination as well as the interpretation of images and measurements obtained. This document provides a detailed methodology for complete ultrasound assessment of the anatomy of the superficial and perforating veins in the lower limbs. Conclusions: The authors and a large group of experts have agreed on a methodology for the investigation of the lower limbs venous system, by duplex ultrasonography, with specific reference to the anatomy of the main superficial veins and perforators of the lower limbs in healthy and varicose subjects.


Sign in / Sign up

Export Citation Format

Share Document