scholarly journals Comparison study of image quality at various radiation doses for CT venography using advanced modeled iterative reconstruction

PLoS ONE ◽  
2021 ◽  
Vol 16 (8) ◽  
pp. e0256564
Author(s):  
Jung Han Hwang ◽  
Jin Mo Kang ◽  
So Hyun Park ◽  
Suyoung Park ◽  
Jeong Ho Kim ◽  
...  

Objective We compared the image quality according to the radiation dose on computed tomography (CT) venography at 80 kVp using advanced modeled iterative reconstruction for deep vein thrombus and other specific clinical conditions considering standard-, low-, and ultralow-dose CT. Methods In this retrospective study, 105 consecutive CT venography examinations were included using a third-generation dual-source scanner in the dual-source mode in tubes A (reference mAs, 210 mAs at 70%) and B (reference mAs, 90 mAs at 30%) at a fixed 80 kVp. Two radiologists independently reviewed each observation of standard- (100% radiation dose), low- (70%), and ultralow-dose (30%) CT. The objective quality of large veins and subjective image quality regarding lower-extremity veins and deep vein thrombus were compared between images according to the dose. In addition, the CT dose index volumes were displayed from the images. Results From the patients, 24 presented deep vein thrombus in 69 venous segments of CT examinations. Standard-dose CT provided the lowest image noise at the inferior vena cava and femoral vein compared with low- and ultralow-dose CT (p < 0.001). There were no differences regarding subjective image quality between the images of popliteal and calf veins at the three doses (e.g., 3.8 ± 0.7, right popliteal vein, p = 0.977). The image quality of the 69 deep vein thrombus segments showed equally slightly higher scores in standard- and low-dose CT (4.0 ± 0.2) than in ultralow-dose CT (3.9 ± 0.4). The CT dose index volumes were 4.4 ± 0.6, 3.1 ± 0.4, and 1.3 ± 0.2 mGy for standard-, low-, and ultralow-dose CT, respectively. Conclusions Low- and ultralow-dose CT venography at 80 kVp using an advanced model based iterative reconstruction algorithm allows to evaluate deep vein thrombus and perform follow-up examinations while showing an acceptable image quality and reducing the radiation dose.

2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Robert Forbrig ◽  
Michael Ingrisch ◽  
Robert Stahl ◽  
Katharina Stella Winter ◽  
Maximilian Reiser ◽  
...  

Abstract In this third-generation dual-source CT (DSCT) study, we retrospectively investigated radiation dose and image quality of portal-venous high-pitch emergency CT in 60 patients (28 female, mean age 56 years) with a body mass index (BMI) ≥ 30 kg/m2. Patients were dichotomized in groups A (median BMI 31.5 kg/m2; n = 33) and B (36.8 kg/m2; n = 27). Volumetric CT dose index (CTDIvol), size-specific dose estimate (SSDE), dose length product (DLP) and effective dose (ED) were assessed. Contrast-to-noise ratio (CNR) and dose-independent figure-of-merit (FOM) CNR were calculated. Subjective image quality was assessed using a five-point scale. Mean values of CTDIvol, SSDE as well as normalized DLP and ED were 7.6 ± 1.8 mGy, 8.0 ± 1.8 mGy, 304 ± 74 mGy * cm and 5.2 ± 1.3 mSv for group A, and 12.6 ± 3.7 mGy, 11.0 ± 2.6 mGy, 521 ± 157 mGy * cm and 8.9 ± 2.7 mSv for group B (p < 0.001). CNR of the liver and spleen as well as each calculated FOM CNR were significantly higher in group A (p < 0.001). Subjective image quality was good in both groups. In conclusion, third-generation abdominal high-pitch emergency DSCT yields good image quality in obese patients. Radiation dose increases in patients with a BMI > 36.8 kg/m2.


2020 ◽  
Vol 30 (5) ◽  
pp. 2712-2721 ◽  
Author(s):  
Waleed Abdellatif ◽  
Eric Esslinger ◽  
Kevin Kobes ◽  
Amanda Wong ◽  
Jennifer Powell ◽  
...  

2017 ◽  
Vol 59 (5) ◽  
pp. 546-552 ◽  
Author(s):  
Yeo-Jin Jeong ◽  
Ki Seok Choo ◽  
Kyung Jin Nam ◽  
Ji Won Lee ◽  
Jin You Kim ◽  
...  

Background Computed tomography venography (CTV) at low kVp using model-based iterative reconstruction (MBIR) can enhance vascular enhancement with noise reduction. Purpose To evaluate image qualities and radiation doses of CTV at 80 kVp using MBIR and a small iodine contrast media (CM) dose and to compare these with those of CTV performed using a conventional protocol. Material and Methods Sixty-five patients (mean age = 58.1 ± 7.2 years) that underwent CTV for the evaluation of deep vein thrombosis (DVT) and varicose veins were enrolled in this study. Patients were divided into two groups: Group A (35 patients, 80 kVp, MBIR, automatic tube current modulation, CM = 270 mg/mL, 100 mL) and Group B (30 patients, 100 kVp, filtered back projection [FBP], 120 fixed mA, CM = 370 mg/mL, 120 mL). Objective and subjective image qualities of inferior vena cava (IVC), femoral vein (FV), and popliteal vein (PV) were assessed and radiation doses were recorded. Results Mean vascular enhancement in group A was significantly lower than in group B ( P < 0.01). Noise in group A was significantly lower than in group B except for PV and contrast-to-noise ratio were not significantly different in the two groups ( P > 0.05). In addition, radiation dose in group A was significantly lower than in group B ( P < 0.001). Subjective image quality comparison revealed group A was statistically inferior to group B except for subjective image noise. Conclusion CTV at 80 kVp using MBIR with small iodine contrast dose provided acceptable image quality at a lower radiation dose than conventional CTV using FBP.


2018 ◽  
Vol 59 (12) ◽  
pp. 1458-1465 ◽  
Author(s):  
Stefan Haneder ◽  
Florian Siedek ◽  
Jonas Doerner ◽  
Gregor Pahn ◽  
Nils Grosse Hokamp ◽  
...  

Background A novel, multi-energy, dual-layer spectral detector computed tomography (SDCT) is commercially available now with the vendor’s claim that it yields the same or better quality of polychromatic, conventional CT images like modern single-energy CT scanners without any radiation dose penalty. Purpose To intra-individually compare the quality of conventional polychromatic CT images acquired with a dual-layer spectral detector (SDCT) and the latest generation 128-row single-energy-detector (CT128) from the same manufacturer. Material and Methods Fifty patients underwent portal-venous phase, thoracic-abdominal CT scans with the SDCT and prior CT128 imaging. The SDCT scanning protocol was adapted to yield a similar estimated dose length product (DLP) as the CT128. Patient dose optimization by automatic tube current modulation and CT image reconstruction with a state-of-the-art iterative algorithm were identical on both scanners. CT image contrast-to-noise ratio (CNR) was compared between the SDCT and CT128 in different anatomic structures. Image quality and noise were assessed independently by two readers with 5-point-Likert-scales. Volume CT dose index (CTDIvol), and DLP were recorded and normalized to 68 cm acquisition length (DLP68). Results The SDCT yielded higher mean CNR values of 30.0% ± 2.0% (26.4–32.5%) in all anatomic structures ( P < 0.001) and excellent scores for qualitative parameters surpassing the CT128 (all P < 0.0001) with substantial inter-rater agreement (κ ≥ 0.801). Despite adapted scan protocols the SDCT yielded lower values for CTDIvol (–10.1 ± 12.8%), DLP (−13.1 ± 13.9%), and DLP68 (–15.3 ± 16.9%) than the CT128 (all P < 0.0001). Conclusion The SDCT scanner yielded better CT image quality compared to the CT128 and lower radiation dose parameters.