scholarly journals Benefits of active middle ear implants over hearing aids in patients with sloping high tone hearing loss: comparison with hearing aids

2017 ◽  
Vol 37 (3) ◽  
pp. 218-223
Author(s):  
J.M. Lee ◽  
J.H. Jeon ◽  
I.S. Moon ◽  
J.Y. Choi

In questo studio retrospettivo, abbiamo confrontato i benefici oggettivi e soggettivi degli impianti attivi dell’orecchio medio (AMEI) rispetto alle tradizionali protesi acustiche (HA) nei pazienti con perdita dell’udito per le frequenze acute. Trentaquattro pazienti con ipoacusia neurosensoriale sono stati trattati con l’impianto di AMEI. Tra questi, sei avevano un audiogramma “in discesa” con perdita dell’udito per le frequenze acute, ed avevano usato per più di sei mesi HA. È stata quindi eseguita una valutazione oggettiva, tramite l’audiometria tonale e il test di riconoscimento delle parole, una versione coreana del “Hearing in Noise Test” (K-HINT), ed una valutazione soggettiva tramite il seguente questionario: Abbreviated Profile of Hearing Aid Benefit (APHAB). I pazienti sono stati sottoposti ai suddetti test in tre occasioni distinte: 1) prima della chirurgia, senza protesi; 2) prima della chirurgia, con HA; 3) tre mesi dopo l’impianto di AMEI. Il guadagno medio per le alte frequenze (≥ 2 kHz) si è rivelato migliore con AMEI che con HA. Sebbene il risultato non ha raggiunto un livello di significatività statistica, gli impianti attivi dell’orecchio medio hanno mostrato un punteggio di riconoscimento delle parole superiore rispetto a HA. Ad ogni modo, il livello di comoda udibilità al quale il punteggio di riconoscimento delle parole è stato testato si è rivelato significativamente più basso con AMEI rispetto ad HA. Al K-HINT i pazienti con AMEI hanno mostrato un migliore riconoscimento rispetto ai risultati ottenuti con HA, sia in condizione di quiete sia di rumore. Gli score APAHB hanno rivelato che i pazienti erano più soddisfatti con AMEI. L’uso degli impianti attivi dell’orecchio medio in pazienti con perdita dell’udito per le frequenze acute ha permesso di ottenere risultati migliori rispetto all’utilizzo delle protesi tradizionali. Basandoci su questi dati, gli AMEI hanno offerto risultati oggettivi e soggettivi migliori, e pertanto, potrebbero rappresentare una valida alternativa per il trattamento delle ipoacusie con audiogramma in discesa.

2019 ◽  
Vol 28 (2) ◽  
pp. 274-284 ◽  
Author(s):  
Elizabeth Convery ◽  
Gitte Keidser ◽  
Louise Hickson ◽  
Carly Meyer

Purpose Hearing loss self-management refers to the knowledge and skills people use to manage the effects of hearing loss on all aspects of their daily lives. The purpose of this study was to investigate the relationship between self-reported hearing loss self-management and hearing aid benefit and satisfaction. Method Thirty-seven adults with hearing loss, all of whom were current users of bilateral hearing aids, participated in this observational study. The participants completed self-report inventories probing their hearing loss self-management and hearing aid benefit and satisfaction. Correlation analysis was used to investigate the relationship between individual domains of hearing loss self-management and hearing aid benefit and satisfaction. Results Participants who reported better self-management of the effects of their hearing loss on their emotional well-being and social participation were more likely to report less aided listening difficulty in noisy and reverberant environments and greater satisfaction with the effect of their hearing aids on their self-image. Participants who reported better self-management in the areas of adhering to treatment, participating in shared decision making, accessing services and resources, attending appointments, and monitoring for changes in their hearing and functional status were more likely to report greater satisfaction with the sound quality and performance of their hearing aids. Conclusion Study findings highlight the potential for using information about a patient's hearing loss self-management in different domains as part of clinical decision making and management planning.


2020 ◽  
Author(s):  
Willy Nguyen ◽  
Miseung Koo ◽  
Seung Ha Oh ◽  
Jun Ho Lee ◽  
Moo Kyun Park

BACKGROUND Underuse of hearing aids is caused by several factors, including the stigma associated with hearing disability, affordability, and lack of awareness of rising hearing impairment associated with the growing population. Thus, there is a significant opportunity for the development of direct-to-consumer devices. For the past few years, smartphone-based hearing-aid apps have become more numerous and diverse, but few studies have investigated them. OBJECTIVE This study aimed to elucidate the electroacoustic characteristics and potential user benefits of a selection of currently available hearing-aid apps. METHODS We investigated the apps based on hearing-aid control standards (American National Standards Institute) using measurement procedures from previous studies. We categorized the apps and excluded those we considered inefficient. We investigated a selection of user-friendly, low-end apps, EarMachine and Sound Amplifier, with warble-tone audiometry, word recognition testing in unaided and aided conditions, and hearing-in-noise test in quiet and noise-front conditions in a group of users with mild hearing impairment (n = 7) as a pilot for a future long-term investigation. Results from the apps were compared with those of a conventional hearing aid. RESULTS Five of 14 apps were considered unusable based on low scores in several metrics, while the others varied across the range of electroacoustic measurements. The apps that we considered “high end” that provided lower processing latencies and audiogram-based fitting algorithms were superior overall. The clinical performance of the listeners tended to be better when using hearing aid, while the low end hearing-aid apps had limited benefits on the users. CONCLUSIONS Some apps showed the potential to benefit users with limited cases of minimal or mild hearing loss if the inconvenience of relatively poor electroacoustic performance did not outweigh the benefits of amplification.


2020 ◽  
Vol 5 (1) ◽  
pp. 36-39
Author(s):  
Mariya Yu. Boboshko ◽  
Irina P. Berdnikova ◽  
Natalya V. Maltzeva

Objectives -to determine the normative data of sentence speech intelligibility in a free sound field and to estimate the applicability of the Russian Matrix Sentence test (RuMatrix) for assessment of the hearing aid fitting benefit. Material and methods. 10 people with normal hearing and 28 users of hearing aids with moderate to severe sensorineural hearing loss were involved in the study. RuMatrix test both in quiet and in noise was performed in a free sound field. All patients filled in the COSI questionnaire. Results. The hearing impaired patients were divided into two subgroups: the 1st with high and the 2nd with low hearing aid benefit, according to the COSI questionnaire. In the 1st subgroup, the threshold for the sentence intelligibility in quiet was 34.9 ± 6.4 dB SPL, and in noise -3.3 ± 1.4 dB SNR, in the 2nd subgroup 41.7 ± 11.5 dB SPL and 0.15 ± 3.45 dB SNR, respectively. The significant difference between the data of both subgroups and the norm was registered (p


2020 ◽  
Vol 25 (3) ◽  
pp. 133-142
Author(s):  
Nina Wardenga ◽  
Ad F.M. Snik ◽  
Eugen Kludt ◽  
Bernd Waldmann ◽  
Thomas Lenarz ◽  
...  

Background: The conventional therapy for severe mixed hearing loss is middle ear surgery combined with a power hearing aid. However, a substantial group of patients with severe mixed hearing loss cannot be treated adequately with today’s state-of-the-art (SOTA) power hearing aids, as predicted by the accompanying part I of this publication, where we compared the available maximum power output (MPO) and gain from technical specifications to requirements for optimum benefit using a common fitting rule. Here, we intended to validate the theoretical assumptions from part I experimentally in a mixed hearing loss cohort fitted with SOTA power hearing aids. Additionally, we compared the results with an implantable hearing device that circumvents the impaired middle ear, directly stimulating the cochlea, as this might be a better option. Objectives: Speech recognition outcomes obtained from patients with severe mixed hearing loss supplied acutely with a SOTA hearing aid were studied to validate the outcome predictions as described in part I. Further, the results obtained with hearing aids were compared to those in direct acoustic cochlear implant (DACI) users. Materials and Methods: Twenty patients (37 ears with mixed hearing loss) were provided and fitted with a SOTA power hearing aid. Before and after an acclimatization period of at least 4 weeks, word recognition scores (WRS) in quiet and in noise were studied, as well as the speech reception threshold in noise (SRT). The outcomes were compared retrospectively to a second group of 45 patients (47 ears) using the DACI device. Based on the severity of the mixed hearing loss and the available gain and MPO of the SOTA hearing aid, the hearing aid and DACI users were subdivided into groups with prediction of sufficient, partially insufficient, or very insufficient hearing aid performance. Results: The patients with predicted adequate SOTA hearing aid performance indeed showed the best WRS in quiet and in noise when compared to patients with predicted inferior outcomes. Insufficient hearing aid performance at one or more frequencies led to a gradual decrease in hearing aid benefit, validating the criteria used here and in the accompanying paper. All DACI patients showed outcomes at the same level as the adequate hearing aid performance group, being significantly better than those of the groups with inadequate hearing aid performance. Whereas WRS in quiet and noise were sensitive to insufficient gain or output, showing significant differences between the SOTA hearing aid and DACI groups, the SRT in noise was less sensitive. Conclusions: Limitations of outcomes in mixed hearing loss individuals due to insufficient hearing aid performance can be accurately predicted by applying a commonly used fitting rule and the 35-dB dynamic range rule on the hearing aid specifications. Evidently, when outcomes in patients with mixed hearing loss using the most powerful hearing aids are insufficient, bypassing the middle ear with a powerful active middle ear implant or direct acoustic implant can be a promising alternative treatment.


2020 ◽  
Vol 25 (3) ◽  
pp. 125-132
Author(s):  
Nina Wardenga ◽  
Victoria Diedrich ◽  
Bernd Waldmann ◽  
Thomas Lenarz ◽  
Hannes Maier

Objective: The purpose of the present study was to determine the fraction of patients with mixed hearing loss who can or cannot expect benefit from power hearing aids (HAs) after stapes surgery. Design: The audiological outcome of 374 stapes surgeries was used to calculate the patients’ individual postoperative requirements in terms of gain and output of HAs. These requirements were compared to the available gain and output provided by state-of-the-art power HAs at 0.5, 1.0, 2.0, and 4.0 kHz. According to these comparisons, ears were divided into three groups. For G0, required gain and output lay within the corresponding technical limits of the HAs at all frequencies. In G1, one or both requirements could not be fulfilled at 1 frequency. G2 combined all ears where the requirements lay beyond the HA’s technical limitations at 2 or more frequencies. Results: Stapes surgery resulted in an improvement of air-bone gap (ABG) in 84.5% of the cases by 15.7 dB on average. Based on pure-tone average (0.5, 1.0, 2.0, 4.0 kHz), 40.6% of all cases showed an ABG ≤10 dB. 44.9% of all cases did no longer need a HA after stapes surgery. A power HA would fulfill both audiological criteria at all 4 frequencies in 81.6% of cases that needed a HA postoperatively. However, 18.4% would not be sufficiently treatable at 1 or more frequencies (15.0% in G1, 3.4% in G2). Conclusions: The present study identified a subset of patients with mixed hearing loss after stapes surgery that cannot be treated sufficiently with available power HAs. As the residual ABG is an important reason for this lack of treatment success, the advancement of alternative hearing devices that circumvent the middle ear, such as powerful active middle ear implants, is indicated.


2019 ◽  
Vol 30 (04) ◽  
pp. 315-326 ◽  
Author(s):  
Jumana Harianawala ◽  
Jason Galster ◽  
Benjamin Hornsby

AbstractThe hearing in noise test (HINT) is the most popular adaptive test used to evaluate speech in noise performance, especially in context of hearing aid features. However, the number of conditions that can be tested on the HINT is limited by a small speech corpus. The American English Matrix test (AEMT) is a new alternative adaptive speech in noise test with a larger speech corpus. The study examined the relationships between the performance of hearing aid wearers on the HINT and the AEMT.To examine whether there was a difference in performance of hearing aid wearers on the HINT and the AEMT. A secondary purpose, given the AEMT’s steep performance-intensity function, was to determine whether the AEMT is more sensitive to changes in speech recognition resulting from directional (DIR) microphone processing in hearing aids.A repeated measures design was used in this study. Multiple measurements were made on each subject. Each measurement involved a different experimental condition.Ten adults with hearing loss participated in this study.All participants completed the AEMT and HINT, using adaptive and fixed test formats while wearing hearing aids. Speech recognition was assessed in two hearing aid microphone settings—omnidirectional and fixed DIR. All testing was conducted via sound field presentation. Performance on HINT and AEMT were systematically compared across all test conditions using a linear model with repeated measures.The results of this study revealed that adult hearing aid users perform differently on the HINT and AEMT, with adaptive AEMT testing yielding significantly better (more negative) thresholds than the HINT. Slopes of performance intensity functions obtained by testing at multiple fixed signal-to-noise ratios, revealed a somewhat steeper slope for the HINT compared with the AEMT. Despite this steeper slope, the benefit provided by DIR microphones was not significantly different between the two speech tests.The observation of similar DIR benefits of the HINT and AEMT suggests that the HINT and AEMT are equally sensitive to changes in speech recognition thresholds following intervention. Therefore, the decision to use the AEMT or the HINT will depend on the purpose of the study and/or the technology being investigated. Other test related factors such as available sentence corpus, learning effects and test time will also influence test selection.


Author(s):  
L. E. Golooanooa ◽  
E. V. Zhiunskaya ◽  
M. . Yu

164 patients with moderate to severe ehronie bilateral sensorineural hearing loss were asked to fill in the Glasgow hearing aid benefit profile. Its usefulness was showed in eases of diffieult hearing aid fitting.


2007 ◽  
Vol 18 (06) ◽  
pp. 482-495 ◽  
Author(s):  
Lu-Feng Shi ◽  
Karen A. Doherty ◽  
Tammy M. Kordas ◽  
Joseph T. Pellegrino

Currently published hearing aid fitting protocols recommend speech-in-noise testing and loudness measures, but it remains unclear how these measures affect hearing aid benefit and user satisfaction. This study compared two protocols in their effects on benefit and satisfaction. Protocol A included an electroacoustic analysis, real-ear measures, and hearing aid adjustments based on users' comments. Protocol B included all of Protocol A and a speech-in-noise test, loudness discomfort levels, and aided loudness. Thirty-two participants completed the Abbreviated Profile of Hearing Aid Benefit (APHAB) and the Satisfaction with Amplification in Daily Life (SADL) at 45 days and three months post–initial fitting. Fewer hearing aid adjustments were made to the hearing aids for participants fitted with Protocol B than participants fitted with Protocol A, but final gains were similar for both groups. Although similar APHAB scores were obtained for both protocols, SADL scores decreased between 45 days and three months for Protocol A. Los protocoles de amplificación de auxiliares auditivo actualmente publicados recomiendan pruebas de lenguaje en ruido y mediciones de apreciación subjetiva de la intensidad (sonoridad), pero no está claro cómo estas mediciones afectan el beneficio de un auxiliar auditivo y la satisfacción del usuario. El estudio comparó dos protocolos en cuanto a sus efectos sobre beneficio y satisfacción. El Protocolo A incluyó un análisis electroacústico, mediciones de oído real y ajuste en el auxiliar auditivo basados en los comentarios del usuario. El Protocolo B incluyó todas las pruebas del Protocolo A, además de una prueba de audición en ruido, de niveles de molestia en la apreciación subjetiva de la intensidad y de sonoridad amplificada. Treinta y dos participantes completaron el Perfil Abreviado de Beneficio del Auxiliar Auditivo (APHAB) y la prueba de Satisfacción con la Amplificación en la Vida Diaria (SADL) a los 45 días y a los tres meses de la adaptación inicial. Tuvieron que hacerse menos ajustes en el audífono en los auxiliares auditivos de participantes adaptados con el Protocolo B, que en los participantes adaptados con el Protocolo A, pero las ganancias finales fueron similares en ambos grupos. Aunque se obtuvieron puntajes APHAB similares en ambos protocolos, los puntajes SADL disminuyeron entre los 45 días y los tres meses para el Protocolo A.


2021 ◽  
Vol 15 ◽  
Author(s):  
Jing Chen ◽  
Zhe Wang ◽  
Ruijuan Dong ◽  
Xinxing Fu ◽  
Yuan Wang ◽  
...  

Objective: This study was aimed at evaluating improvements in speech-in-noise recognition ability as measured by signal-to-noise ratio (SNR) with the use of wireless remote microphone technology. These microphones transmit digital signals via radio frequency directly to hearing aids and may be a valuable assistive listening device for the hearing-impaired population of Mandarin speakers in China.Methods: Twenty-three adults (aged 19–80 years old) and fourteen children (aged 8–17 years old) with bilateral sensorineural hearing loss were recruited. The Mandarin Hearing in Noise Test was used to test speech recognition ability in adult subjects, and the Mandarin Hearing in Noise Test for Children was used for children. The subjects’ perceived SNR was measured using sentence recognition ability at three different listening distances of 1.5, 3, and 6 m. At each distance, SNR was obtained under three device settings: hearing aid microphone alone, wireless remote microphone alone, and hearing aid microphone and wireless remote microphone simultaneously.Results: At each test distance, for both adult and pediatric groups, speech-in-noise recognition thresholds were significantly lower with the use of the wireless remote microphone in comparison with the hearing aid microphones alone (P < 0.05), indicating better SNR performance with the wireless remote microphone. Moreover, when the wireless remote microphone was used, test distance had no effect on speech-in-noise recognition for either adults or children.Conclusion: Wireless remote microphone technology can significantly improve speech recognition performance in challenging listening environments for Mandarin speaking hearing aid users in China.


Author(s):  
Chan Il Song ◽  
Hyong-Ho Cho ◽  
Byung Yoon Choi ◽  
Jae Young Choi ◽  
Jin Woong Choi ◽  
...  

Objectives. To evaluate the user satisfaction, efficacy, and safety of round window (RW) vibroplasty using the Vibrant Soundbridge (VSB) in patients with persistent mixed hearing loss after mastoidectomy.Methods. The study included twenty-seven patients (mean age, 58.7 years; age range, 28–76 years; 11 men and 16 women) with mixed hearing loss after mastoidectomy surgery from 15 tertiary referral centers in Korea. The VSB was implanted at the RW. The Korean translation of the Abbreviated Profile of Hearing Aid Benefit (APHAB) questionnaire and the Korean version of the International Outcome Inventory for Hearing Aids (K-IOI-HA) questionnaire were used to evaluate user satisfaction as the primary outcome. Secondary outcome measures were audiological test results and complication rates.Results. The mean scores on the Ease of Communication (61.3%