scholarly journals Treatment of wastewater from service areas at motorways

2016 ◽  
Vol 42 (4) ◽  
pp. 80-89 ◽  
Author(s):  
Małgorzata Makowska ◽  
Jakub Mazurkiewicz

Abstract This paper deals with wastewater treatment systems placed in motorway service areas (MSAs). In the years 2008-2009 eight of such facilities installed on the stretch of the A2 motorway between Poznań and Nowy Tomyśl were examined and analyzed. The system consists of a septic tank, a submerged aerated biofilter and an outflow filter. The volume of traffic on the highway was analyzed, the amount of water use was measured and peak factors were calculated. On this basis it was concluded that the inflows to the wastewater treatment systems in many cases exceeded the nominal design values. Based on the analysis of effluent quality it was found that the effects of plant operation in large part did not meet the requirements. It was found that the bioreactor aeration system and the design of the suspension separator (outflow filter) should be modified. One of the solutions was to use the soil-reed bed for wastewater treatment. The treatment of wastewater from the MSAs is a task that must take into account the unusual character of these facilities and the atypical quality of the effluent.

1996 ◽  
Vol 33 (1) ◽  
pp. 81-87
Author(s):  
L. Van Vooren ◽  
P. Willems ◽  
J. P. Ottoy ◽  
G. C. Vansteenkiste ◽  
W. Verstraete

The use of an automatic on-line titration unit for monitoring the effluent quality of wastewater plants is presented. Buffer capacity curves of different effluent types were studied and validation results are presented for both domestic and industrial full-scale wastewater treatment plants. Ammonium and ortho-phosphate monitoring of the effluent were established by using a simple titration device, connected to a data-interpretation unit. The use of this sensor as the activator of an effluent quality proportional sampler is discussed.


2011 ◽  
Vol 1 (1) ◽  
pp. 37-56 ◽  
Author(s):  
Sílvia C. Oliveira ◽  
Marcos von Sperling

This article analyses the performance of 166 wastewater treatment plants operating in Brazil, comprising six different treatment processes: septic tank + anaerobic filter, facultative pond, anaerobic pond + facultative pond, activated sludge, UASB reactors alone, UASB reactors followed by post-treatment. The study evaluates and compares the observed effluent quality and the removal efficiencies in terms of BOD, COD, TSS, TN, TP and FC with typical values reported in the technical literature. In view of the large performance variability observed, the existence of a relationship between design/operational parameters and treatment performance was investigated. From the results obtained, no consistent relationship between loading rates and effluent quality was found. The influence of loading rates differed from plant to plant, and the effluent quality was dictated by several combined factors related to design and operation.


2021 ◽  
Vol 31 (3) ◽  
pp. 265-275
Author(s):  
Ewelina Płuciennik-Koropczuk ◽  
Martyna Myszograj ◽  
Sylwia Myszograj

Abstract The article presents lifestyle as an important factor determining the quantity and quality of municipal wastewater. The characteristic of wastewater in Poland has changed significantly in recent years. The qualitative characteristics of municipal wastewater indicate an increase of organic compounds and in the scope of micro-contaminants identified in them, e.g. nanoparticles, microplastics, pharmaceutical and personal care products or heavy metals. Therefore, the knowledge of parameters such as: BOD5, COD, total N, total P and suspension solids is no longer sufficient for the design and operation of wastewater treatment systems. Comprehensive research in this area is necessary to select those indicators that better describe the characteristics of wastewater.


2020 ◽  
Vol 19 ◽  
pp. 100891 ◽  
Author(s):  
Omar Hamed Jehawi ◽  
Siti Rozaimah Sheikh Abdullah ◽  
Setyo Budi Kurniawan ◽  
Nur ‘Izzati Ismail ◽  
Mushrifah Idris ◽  
...  

2005 ◽  
Vol 3 (1) ◽  
pp. 1-14 ◽  
Author(s):  
J. W. Pundsack ◽  
R. E. Hicks ◽  
R. P. Axler

The objective of this study was to determine how alternative on-site wastewater treatment systems (i.e. subsurface flow constructed wetlands, intermittent sand filters and intermittent peat filters) affect the viability and culturability of Salmonella choleraesuis (serotype typhimurium, ATCC 23567). Influent was a high strength septic tank effluent (BOD5 240–344 mg L−1, TN ∼100 mg L−1, TP ∼ 15 mg L−1) at the Natural Resources Research Institute's (NRRI) alternative treatment system test facility in northern Minnesota. Treatment systems were inoculated with cultures of S. choleraesuis for 5–7 consecutive days in summer and winter during 1998–99. After the seeding, outflow samples were taken until Salmonella counts were sustained at background levels. In addition to culture-based enumeration, S. choleraesuis abundances were also measured using fluorescent in situ hybridization (FISH) alone and in combination with the direct viable count method (DVC) to determine if plate counts underestimated total and viable Salmonella abundances and if the Salmonella cell viability changed after passing through the treatment systems. In most cases, total and viable cell abundances in treatment system effluents were several orders of magnitude higher than cultured cell abundances. Our results indicate that the culture-based method underestimated viable concentrations of the model pathogen, S. choleraesuis. Salmonella cell viability decreased in effluents during the summer but increased during the winter. Using a culture-based enumeration method alone to determine removal efficiencies of bacterial indicators and pathogens for wastewater treatment systems may result in artificially high estimates of effective treatment.


2016 ◽  
Author(s):  
Kanha But ◽  
◽  
Ranjna Jindal ◽  
Nawatch Surinkul ◽  
Kim N. Irvine ◽  
...  

2013 ◽  
Vol 39 (1) ◽  
pp. 3-16 ◽  
Author(s):  
Katarzyna Pawęska ◽  
Krzysztof Kuczewski

Abstract The paper presents results of research concerning operating of five small wastewater treatment plants working in two different technologies: hydrobotanical wastewater treatment plant and constructed wetland. Each object was designed for the treatment of domestic sewage after preliminary mechanical treatment in a septic tank. Hydrobotanical wastewater treatment plants and one of constructed wetland beds were built for treating sewage produced in educational institutions and resort. In the article attention is paid to possibility of exceeding the maximum allowable concentration of pollutants for three main indicators of pollution: BOD5, COD, and total suspension. The reduction of these indices is required by the Regulation of the Minister of Environment [14] for wastewater treatment plants with PE < 2000. In addition, the paper presents the effects of wastewater treatment to reduce biogens. The best quality of outflow was reached by outflows from constructed wetland treatment plants. None of the observed objects fulfilled the requirements in terms of allowable concentrations for total suspension. The most effective were objects operating in technology of “constructed wetland”.


1996 ◽  
Vol 33 (7) ◽  
pp. 41-47 ◽  
Author(s):  
Marcos von Sperling

The paper presents a methodology for the utilisation of the Uncertainty analysis based on Monte Carlo simulations for the design of wastewater treatment systems. The special and important case of facultative-ponds design is exemplified. The design is carried out a large number of times, each run with different values of the inputs, randomly selected from uniform distributions within ranges which define the designer's uncertainty with the data. The results are interpreted statistically, giving elements for the selection of more or less conservative designs, according to the resulting effluent quality. The procedure for undertaking a Sensitivity Analysis is also described and exemplified, allowing the designer to concentrate more efforts on a more accurate determination of those inputs found to be significantly important.


Sign in / Sign up

Export Citation Format

Share Document