scholarly journals Controlling the Distribution of Cold Water in Air Cooling Systems of Underground Mines

2016 ◽  
Vol 61 (4) ◽  
pp. 793-807 ◽  
Author(s):  
Nikodem Szlązak ◽  
Dariusz Obracaj ◽  
Justyna Swolkień ◽  
Kazimierz Piergies

Abstract In Polish underground mines in which excavations are subjected to high heat load, central and group cooling systems based on indirect cooling units are implemented. Chilled water, referred to as cold water and produced in chillers, is distributed through a pipeline network to air coolers located in mining and development districts. The coolers are often moved to other locations and the pipeline network undergoes constant modification. In such a system, parameters of cold water in different branches of the pipeline network need to be controlled. The article presents the principles for controlling the cooling capacity of air coolers installed in an underground mine. Also, the authors propose automatic control of water flow rate in underground pipeline network and in particular coolers, depending on the temporary cooling load in the system. The principles of such a system, controlling cold water distribution, and the functions of its individual components are described. Finally, an example of an automatic control of water flow rate in a central cooling system currently implemented in a mine is presented.

2014 ◽  
Vol 905 ◽  
pp. 263-267
Author(s):  
Shin Ku Lee ◽  
W.H. Lo ◽  
M.C. Ho ◽  
T.H. Lin

The hybrid inverse method to estimate the optimal water flow rate and surface temperature on the hot surface of the steel roller shutter with water film cooling system subjected to a fire environment is presented in this paper. The results show that the effect of the down-flowing water film flow rate on the present estimates cannot be negligible. The water-film system combined with the steel roller shutter can effectively improve the heat resistance and the temperature of the shutter slat surface can be controlled to around 100 °C. The optimal water flow rate is 110 L/min for a typical 3m x 3m steel roller shutter with water film cooling system.


Author(s):  
Luis R. Figueroa Ibarra ◽  
J. Hugo Rodri´guez Marti´nez ◽  
Marcelino Santaba´rbara Botello

This paper details the design of a Pitot tube used for water flow rate measurements in large pipes. The paper describes first the nowadays commonly used device (simplex pitot), based on standard CTI Code ATC-105 from Cooling Tower Institute [1]. The disadvantages of the simplex pitot are pointed out, and the detailed description of the proposed device (multiport pitot) is explained. The Multiport Pitot, which design is also based on norm ATC-105, is able to perform real-time measurements. The paper also includes the results obtained from the water flow rate measurements made in the cooling system of a thermal power plant in Mexico. These measurement results were compared to simulation results obtained with a computational commercial simulation tool.


2020 ◽  
Vol 10 (3) ◽  
pp. 810 ◽  
Author(s):  
Jinfang Zhang ◽  
Zeyu Li ◽  
Yue Jing ◽  
Yongrui Xu

The solar absorption-subcooled compression hybrid cooling system (SASCHCS) is tech-economically feasible for high-rise buildings. Since such a system operates with no auxiliary heat source, the performance coupling of its absorption subsystem and solar collectors is sensitive to the variation of hot water flow rate. In this regard, the relationship of system performance and hot water flow rate is required to be clarified exactly. Therefore, this paper aims to illustrate the effect mechanism of hot water flow rate and to propose the corresponding decision criterion. The case study is based on a typical high-rise office building in subtropical Guangzhou. The daily working process of this system with different hot water flow rates is simulated and analyzed. Subsequently, the useful heat of collectors and cooling capacity of the absorption subsystem with the hot water flow rate is discussed in detail. The results show that the SASCHCS operates with hot water temperatures ranging from 60 °C to 90 °C. The energy saving increases with the rise of hot water flow rate, but such variation tends to be flat for the excessively high flow rate. As the collector flow rate increases from 1 m3/h to 10 m3/h, the daily energy saving improves by 21% in August. Similarly, the daily energy saving increases by 37.5% as generator hot water flow rate increases from 1 m3/h to 10 m3/h. In addition, the collector flow rate of 3.6 m3/h (13.33 (kg/m2 h)) and the generator flow rate of 5.2 m3/h (19.26 (kg/m2 h)) are optimal for the annual operation, with considering power consumption of water pumps. This paper is helpful for the improvement of SASCHCS operating performance.


2020 ◽  
Vol 51 (4) ◽  
pp. 209-219
Author(s):  
Mohamed Saied Ghoname

An experiment was conducted in three commercial laying hen houses with 32-week-old hens in the summer of 2017 in a commercial farm in Gharbia Province, Egypt (31.06ºN, 31.16ºE) using an evaporative pad cooling system to determine the most suitable water flow rate for maintaining indoor air temperature within the thermal comfort zone. The experiment was conducted using three different water flow rates, i.e. 4.76, 5.65, and 6.35 L min–1.m–2, to assess the effect of different water flow rates on evaporative pad cooling system performance and determine the most suitable water flow rate for maintaining the thermal comfort zone of laying hens. The evaporative pad cooling system maintained the mean indoor air temperature below 28°C. The mean indoor air relative humidity during the experimental period ranged from 72.6 to 73.8%. The 4.76 L min–1.m–2 water flow rate resulted in the highest saturation efficiency (ca. 73.75%). In contrast, the 6.35 L min–1 m–2 water flow rate resulted in the lowest saturation efficiency (70.63%). The mean cooling energy values were 69.11, 66.0, and 66.65 kwh for water flow rates of 4.76, 5.56, and 6.35 Lmin–1m–2, respectively. The highest temperature-humidity index was 27.78°C, which indicated that birds were not stressed in all treatments.


Author(s):  
Takahiro Moribe ◽  
Hiroto Endo ◽  
Shuichiro Miwa ◽  
Hiroto Sakashita ◽  
Michitsugu Mori

Steam Injector (SI) is a passive pump activated by steam and water, and it does not require any external power supplies or rotating machineries. Moreover, SI has high ability as a heat exchanger by undergoing direct contact condensation mechanism. From these characteristics, SI has a capability to be applied as a passive safety system in the nuclear power plant. In the present study, experiments targeting the operating range and pump performance were carried out to obtain SI’s detailed characteristics under following supply conditions; inlet steam pressure was 0.02 ∼ 0.81MPaG, inlet water flow rate was 0.21 ∼ 0.80 kg/s. In the former experiment, operating range was investigated by changing inlet conditions, and the influence of steam inlet pressure and water inlet flow rates on SI operating range was tested. In the latter experiment, pump performance of SI was evaluated by investigating the maximum discharge pressure in each inlet condition by using back pressure valve. From the results of experiments, it was confirmed the operating range of SI was limited by supplied steam pressure and supplied water flow rate, and some clear trends were found in the operation boundary map. In addition, SI could discharge water at least 1.2 times higher than inlet steam pressure under above-mentioned conditions, which verified SI’s capability to be applied for the nuclear power plant as a core cooling system. And furthermore, existing 1D analysis model’s predictive capability was tested based on these experimental results.


2014 ◽  
Vol 931-932 ◽  
pp. 1078-1082 ◽  
Author(s):  
Warachit Phayom ◽  
Apichai Namahima

This study was for design an economy cooler for increasing energy conversion efficiency of solar panel. Acrylic plastic was used to be material of the cooler and water was a working fluid in the system. The cost to build the cooler model was around 400 Baht. The results found, using cooling system increased energy conversion efficiency and power generation, especially, water flow rate at 200 ccm. At 200 ccm of water flow rate, it increased 0.52% of energy conversion efficiency and 18.01% of power generation. Thus this flow rate was the best condition for increasing energy conversion efficiency. It might due to this flow rate was not slow and was not that fast to absorb heat from solar panel.


Metals ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 682
Author(s):  
Eko Surojo ◽  
Aziz Harya Gumilang ◽  
Triyono Triyono ◽  
Aditya Rio Prabowo ◽  
Eko Prasetya Budiana ◽  
...  

Underwater wet welding (UWW) combined with the shielded metal arc welding (SMAW) method has proven to be an effective way of permanently joining metals that can be performed in water. This research was conducted to determine the effect of water flow rate on the physical and mechanical properties (tensile, hardness, toughness, and bending effect) of underwater welded bead on A36 steel plate. The control variables used were a welding speed of 4 mm/s, a current of 120 A, electrode E7018 with a diameter of 4 mm, and freshwater. The results show that variations in water flow affected defects, microstructure, and mechanical properties of underwater welds. These defects include spatter, porosity, and undercut, which occur in all underwater welding results. The presence of flow and an increased flow rate causes differences in the microstructure, increased porosity on the weld metal, and undercut on the UWW specimen. An increase in water flow rate causes the acicular ferrite microstructure to appear greater, and the heat-affected zone (HAZ) will form finer grains. The best mechanical properties are achieved by welding with the highest flow rate, with a tensile strength of 534.1 MPa, 3.6% elongation, a Vickers microhardness in the HAZ area of 424 HV, and an impact strength of 1.47 J/mm2.


2021 ◽  
Vol 13 (5) ◽  
pp. 168781402110208
Author(s):  
Yuan Zhang ◽  
Lifeng Wang ◽  
Yaodong Zhang ◽  
Yongde Zhang

The thermal deformation of high-speed motorized spindle will affect its reliability, so fully considering its thermal characteristics is the premise of optimal design. In order to study the thermal characteristics of high-speed motorized spindles, a coupled model of thermal-flow-structure was established. Through experiment and simulation, the thermal characteristics of spiral cooling motorized spindle are studied, and the U-shaped cooled motorized spindle is designed and optimized. The simulation results show that when the diameter of the cooling channel is 7 mm, the temperature of the spiral cooling system is lower than that of the U-shaped cooling system, but the radial thermal deformation is greater than that of the U-shaped cooling system. As the increase of the channel diameter of U-shaped cooling system, the temperature and radial thermal deformation decrease. When the diameter is 10 mm, the temperature and radial thermal deformation are lower than the spiral cooling system. And as the flow rate increases, the temperature and radial thermal deformation gradually decrease, which provides a basis for a reasonable choice of water flow rate. The maximum error between experiment and simulation is 2°C, and the error is small, which verifies the accuracy and lays the foundation for future research.


Author(s):  
Afshin Goharzadeh ◽  
Keegan Fernandes

This paper presents an experimental investigation on a modified airlift pump. Experiments were undertaken as a function of air-water flow rate for two submergence ratios (ε=0.58 and 0.74), and two different riser geometries (i) straight pipe with a constant inner diameter of 19 mm and (ii) enlarged pipe with a sudden expanded diameter of 19 to 32 mm. These transparent vertical pipes, of 1 m length, were submerged in a transparent rectangular tank (0.45×0.45×1.1 m3). The compressed air was injected into the vertical pipe to lift the water from the reservoir. The flow map regime is established for both configurations and compared with previous studies. The two phase air-water flow structure at the expansion region is experimentally characterized. Pipeline geometry is found to have a significant influence on the output water flow rate. Using high speed photography and electrical conductivity probes, new flow regimes, such as “slug to churn” and “annular to churn” flow, are observed and their influence on the output water flow rate and efficiency are discussed. These experimental results provide fundamental insights into the physics of modified airlift pump.


Sign in / Sign up

Export Citation Format

Share Document