Telecentric line scanning system based on a ring surface mirror for inline processes

2016 ◽  
Vol 5 (3) ◽  
Author(s):  
Florian Loosen ◽  
Norbert Lindlein ◽  
Klaus Donner

AbstractIn many industrial applications, an inline measurement of a production process poses a difficult challenge for any optical system. Therefore, telecentric optical systems are being used to ensure an independence of the magnification of the object from the working distance. Usually, telecentric optical systems are impractical for inline applications with large objects due to the size of the telecentric optical system, which has to be larger than the object. Therefore, a new approach of telecentric line scanning systems was developed to gain access to this advantage.

2020 ◽  
Vol 48 (4) ◽  
pp. 899-907
Author(s):  
Vimal Pathak ◽  
Ashish Srivastava ◽  
Sumit Gupta

This paper presents an innovative method to investigate the accuracy and capability of contactless laser scanning systems in terms of geometrical dimensioning and tolerancing (GD&T) control. The current work proposes a standard benchmark part with typical features conforming to different families of GD&T. The benchmark part designed consists of various canonical features widely used in an engineering and industrial applications. Further, the adopted approach includes the methodology for comparison of geometry using a common alignment method for contactless scanning system and a CMM. In addition, proposal of different scanning orientation methods for contactless system is also realized. Surface reconstruction of the benchmark model is achieved using different reverse engineering software, and results are analyzed to study the correlation between different geometries of contact and contactless system. Considering the contact based measurement as a reference, different models developed were analyzed and compared in terms of geometrical and dimensional tolerance. The proposal of standard benchmark part and methodology for GD&T verification will provide a simple and effective way of performance evaluation for various contactless laser-scanning systems in terms of deviations.


Author(s):  
J T Fourie

The attempts at improvement of electron optical systems to date, have largely been directed towards the design aspect of magnetic lenses and towards the establishment of ideal lens combinations. In the present work the emphasis has been placed on the utilization of a unique three-dimensional crystal objective aperture within a standard electron optical system with the aim to reduce the spherical aberration without introducing diffraction effects. A brief summary of this work together with a description of results obtained recently, will be given.The concept of utilizing a crystal as aperture in an electron optical system was introduced by Fourie who employed a {111} crystal foil as a collector aperture, by mounting the sample directly on top of the foil and in intimate contact with the foil. In the present work the sample was mounted on the bottom of the foil so that the crystal would function as an objective or probe forming aperture. The transmission function of such a crystal aperture depends on the thickness, t, and the orientation of the foil. The expression for calculating the transmission function was derived by Hashimoto, Howie and Whelan on the basis of the electron equivalent of the Borrmann anomalous absorption effect in crystals. In Fig. 1 the functions for a g220 diffraction vector and t = 0.53 and 1.0 μm are shown. Here n= Θ‒ΘB, where Θ is the angle between the incident ray and the (hkl) planes, and ΘB is the Bragg angle.


Author(s):  
Pablo Cazenave ◽  
Katina Tiñacos ◽  
Ming Gao ◽  
Richard Kania ◽  
Rick Wang

New technologies for in-ditch non-destructive evaluation were lately developed and are becoming of mainstream use in the evaluation of external corrosion features for both In-Line-Inspection performance evaluation and pipeline integrity assessment. However, doubt was cast about the reliability and repeatability of these new technologies (hardware and processing software) when compared with those used in the traditional external-corrosion in-ditch measurement and the reliability of the pipeline integrity assessment calculations (PBurst) embedded in their software when compared with industry-wide accepted calculation methods. Therefore, the primary objective of this study is to evaluate the variation and repeatability of the measurements produced by these new technologies in corrosion feature profiling and associated PBurst calculations. Two new 3D scanning systems were used for the evaluation of two pipe samples removed from service which contain complex external corrosion features in laboratory. The reliability of the 3D scanning system in measuring corrosion profiles was evaluated against traditional profile gage data. In addition, the associated burst pressures reported by the systems were compared with results obtained using industry-widely used calculation methods. Also, consistencies, errors and gaps in results were identified. In this paper, the approach used for this study is described first, the evaluation results are then presented and finally the findings and their implications are discussed.


2006 ◽  
Vol 50 (4) ◽  
pp. 1586-1589 ◽  
Author(s):  
Audrey Gego ◽  
Olivier Silvie ◽  
Jean-François Franetich ◽  
Khemaïs Farhati ◽  
Laurent Hannoun ◽  
...  

ABSTRACT Plasmodium liver stages represent potential targets for antimalarial prophylactic drugs. Nevertheless, there is a lack of molecules active on these stages. We have now developed a new approach for the high-throughput screening of drug activity on Plasmodium liver stages in vitro, based on an infrared fluorescence scanning system. This method allowed us to count automatically and rapidly Plasmodium-infected hepatocytes, using different hepatic cells and different Plasmodium species, including Plasmodium falciparum. This new technique is well adapted for high-throughput drug screening and should facilitate the identification of new antimalarial compounds active on Plasmodium liver stages.


Sensors ◽  
2019 ◽  
Vol 20 (1) ◽  
pp. 65 ◽  
Author(s):  
Pavel Ripka ◽  
Josef Blažek ◽  
Mehran Mirzaei ◽  
Pavol Lipovský ◽  
Miroslav Šmelko ◽  
...  

Magnetic position and speed sensors are rugged and durable. While DC magnetic sensors use permanent magnets as a field source and usually have only mm or cm range, inductive sensors use electromagnetic induction and they may work up to a distance of 20 m. Eddy current inductive sensors equipped with magnetoresistive sensors instead of inductive coils can operate at low frequencies, allowing detection through a conductive wall. In this paper, we make an overview of existing systems and we present new results in eddy current velocity and position measurements. We also present several types of inductive position sensors developed in our laboratories for industrial applications in pneumatic and hydraulic cylinders, underground drilling, large mining machines, and for detecting ferromagnetic objects on conveyors. While the most precise inductive position sensors have a resolution of 10 nm and linearity of 0.2%, precision requirements on the industrial sensors which we develop are less demanding, but they should have large working distance and large resistance to environmental conditions and interference.


Materials ◽  
2019 ◽  
Vol 12 (2) ◽  
pp. 308 ◽  
Author(s):  
Christian Kledwig ◽  
Holger Perfahl ◽  
Martin Reisacher ◽  
Frank Brückner ◽  
Jens Bliedtner ◽  
...  

The growing number of commercially available machines for laser deposition welding show the growing acceptance and importance of this technology for industrial applications. Their increasing usage in research and production requires process stability and user-friendly handling. A commercially available DMG MORI LT 65 3D hybrid machine used in combination with a CCD-based coaxial temperature measurement system was utilized in this work to investigate what information relating to the intensity distribution of melt pool surfaces could be appropriate to draw conclusions about process conditions. In this study it is shown how the minimal required specific energy for a stable process can be determined, and it is indicated that the evolution of a plasma plume depends on thermal energy within the base material. An estimated melt pool area—calculated by the number of pixels (NOP) with intensities larger than a fixed, predefined threshold—builds the main measure in analysing images from the process camera. The melt pool area and its temporal variance can also serve as an indicator for an increased working distance.


2014 ◽  
Vol 555 ◽  
pp. 751-758 ◽  
Author(s):  
Nicolae Guzulescu ◽  
Cornel Todirică ◽  
Daniel Lăpădat

An distortion aberration free optical system forms an orthoscopic image mean that is similar to original object, undeformed. Naturally imply that most optical systems are designed so that the image distortion is minimal, not to cause inconvenience to the user about either the object appearance – when it comes to a camera or camcorder, or the deformities that may cause measurement errors – when it comes to optical measurement and control equipment. However there are situations when distortion is desired to improve some performances of the observation optical system. In this article we present how distortion is used to increase the field of view, and also how distortion is used to optimize the field of view – resolution compromise.


Sign in / Sign up

Export Citation Format

Share Document