scholarly journals Accuracy and Reliability of Inertial Devices for Load Assessment During Flywheel Workout

2021 ◽  
Vol 19 (1) ◽  
pp. 1-11
Author(s):  
Jose Pino-Ortega ◽  
Alejandro Hernández-Belmonte ◽  
Alejandro Bastida-Castillo ◽  
Carlos Gómez-Carmona ◽  
Daniel Rojas-Valverde

There is currently an increase in inertial flywheel application in strength training; thus, it must be monitored by an accurate and reliable device. The present study tested: (1) the accuracy of an inertial measurement device (IMU) to correctly measure angular velocity and (2) its inter-unit reliability for the measurement of external load. The analysis was performed using Pearson Correlation and Intraclass Correlation Coefficient (ICC). The IMU accuracy was tested using Bland-Altman and the reliability with the coefficient of variation (CV). Ten elite-level football players performed ten series of 5 repetitions in a one-hand standing row exercise (5 series with each arm). A nearly perfect accuracy (ICC=.999) and a very good between-device reliability (Bias=-.010; CV=.017%) was found. IMU is a reliable and valid device to assess angular velocity in inertial flywheel workout objectively.

Author(s):  
José Pino-Ortega ◽  
Alejandro Bastida-Castillo ◽  
Alejandro Hernández-Belmonte ◽  
Carlos D Gómez-Carmona

Traditionally, linear transducers have been used to evaluate resistance exercise with linear displacement. The current problem is the assessment of exercises with curvilinear displacement. For this reason, new devices should be assessed during training sessions. The purpose was to evaluate (1) the concurrent validity of mean linear velocity and (2) the convergent validity of mean angular velocity measured by an inertial device during a leg extension exercise. Ten elite-level football players completed six series of five repetitions of a leg extension exercise. WIMU PRO™ inertial device and GymAware® linear transducers as criterion measure were used to register data. To assess concurrent validity, the bias of the inertial device measures of velocity was analyzed with Bland–Altman plots with limits of agreement set at 95%. Convergent validity of inertial device measures of velocity was assessed with Pearson’s correlation analysis. Concurrent analysis showed a nearly perfect validity between linear transducers and inertial device in linear ( Bias = –0.011 ± 0.006) and angular velocity (–0.34 ± 2.08). A nearly perfect Pearson’s product–moment correlation coefficient between an inertial device and linear transducers in linear velocity ( r = 0.999) and between an inertial device and linear transducers (calculated) in angular velocity ( r = 0.999) was found. In conclusion, WIMU PRO is valid for measuring linear and angular velocity during two-dimensional linear and rotational motions of exercise equipment. This device can be used as a useful tool to assess movement velocity in resistance training exercises, even in curvilinear movements when linear transducers have obvious limitations.


Author(s):  
Carlos Lago-Fuentes ◽  
Paolo Aiello ◽  
Mauro Testa ◽  
Iker Muñoz ◽  
Marcos Mecías Calvo

AbstractThe purpose of this study was to analyze the validity and the reliability of the intensity ranges, number of actions and changes of direction measured by a commercial inertial measurement unit. Eleven elite youth futsal players performed a circuit with different type of displacements as sprinting, running at low-medium intensity, standing up and changes of direction. Data recorded by the Overtraq system were compared with video-analyzer during the six trials of each player. Standard error mean, Intraclass Correlation Coeficient and Coefficient of variation, were calculated to analyze the reliability of the device, as well as the Root Mean Square Error and Confidence Interval with correlation of Pearson for its validity. The results reported good validity for three intensity ranges (R2>0.7) with high reliability (Intraclass Correlation Coeficient: 0.8–0.9), especially for high intensity actions (Intraclass Correlation Coeficient: 0.95, Coefficient of Variation: 3.06%). Furthermore, the validity for the number of different actions was almost perfect (96.3–100%), with only small differences regarding changes of activity (mean error: 2.0%). The Overtraq system can be considered as a valid and reliable technology for measuring and monitoring actions at different intensities and changes of direction in futsal, likewise common actions for other indoor sports.


2019 ◽  
Vol 11 (6) ◽  
pp. 535-542 ◽  
Author(s):  
Nels D. Leafblad ◽  
Dirk R. Larson ◽  
Glenn S. Fleisig ◽  
Stan Conte ◽  
Stephen A. Fealy ◽  
...  

Background: The variability of throwing metrics, particularly elbow torque and ball velocity, during structured long-toss programs is unknown. Hypotheses: (1) Elbow torque and ball velocity would increase as throwers progressed through a structured long-toss program and (2) intrathrower reliability would be high while interthrower reliability would be variable. Study Design: Descriptive laboratory study. Level of Evidence: Level 3. Methods: Sixty healthy high school and collegiate pitchers participated in a structured long-toss program while wearing a validated inertial measurement unit, which measured arm slot, arm velocity, shoulder rotation, and elbow varus torque. Ball velocity was assessed by radar gun. These metrics were compared within and between all pitchers at 90, 120, 150, and 180 ft and maximum effort mound pitching. Intra- and interthrower reliabilities were calculated for each metric at every stage of the program. Results: Ball velocity significantly changed at each progressive throwing distance, but elbow torque did not. Pitching from the mound did not place more torque on the elbow than long-toss throwing from 120 ft and beyond. Intrathrower reliability was excellent (intraclass correlation coefficient >0.75) throughout the progressive long-toss program, especially on the mound. Ninety-one percent of throwers had acceptable interthrower reliability (coefficient of variation <5%) for ball velocity, whereas only 79% of throwers had acceptable interthrower reliability for elbow torque. Conclusion: Based on trends in elbow torque, it may be practical to incorporate pitching from the mound earlier in the program (once a player is comfortable throwing from 120 ft). Ball velocity and elbow torque do not necessarily correlate with one another, so a degree of caution should be exercised when using radar guns to estimate elbow torque. Given the variability in elbow torque between throwers, some athletes would likely benefit from an individualized throwing program. Clinical Relevance: Increased ball velocity does not necessarily equate to increased elbow torque in long-toss. Some individuals would likely benefit from individualized long-toss programs for rehabilitation.


2017 ◽  
Vol 3 (1) ◽  
pp. 7-10 ◽  
Author(s):  
Jan Kuschan ◽  
Henning Schmidt ◽  
Jörg Krüger

Abstract:This paper presents an analysis of two distinct human lifting movements regarding acceleration and angular velocity. For the first movement, the ergonomic one, the test persons produced the lifting power by squatting down, bending at the hips and knees only. Whereas performing the unergonomic one they bent forward lifting the box mainly with their backs. The measurements were taken by using a vest equipped with five Inertial Measurement Units (IMU) with 9 Dimensions of Freedom (DOF) each. In the following the IMU data captured for these two movements will be evaluated using statistics and visualized. It will also be discussed with respect to their suitability as features for further machine learning classifications. The reason for observing these movements is that occupational diseases of the musculoskeletal system lead to a reduction of the workers’ quality of life and extra costs for companies. Therefore, a vest, called CareJack, was designed to give the worker a real-time feedback about his ergonomic state while working. The CareJack is an approach to reduce the risk of spinal and back diseases. This paper will also present the idea behind it as well as its main components.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Sahaprom Namano ◽  
Orapin Komin

Abstract Background Complete tooth losses are still being major problems which resulted in lesser quality of life especially for elderly patients. However, there are still lack of questionnaire to evaluate the treatment outcome from the patient’s aspect. The objective of this study is to evaluate the reliability and validity of the Patient’s Denture Assessment-Thai version (PDA-T), then use this questionnaire to assess patient satisfaction with complete denture treatment outcome also investigates the factors involving their satisfaction. Methods The subjects comprised 120 edentulous adult patients (49 men/71 women; average age 70 years-old) from the Prosthodontic and the Geriatric Dentistry and Special Patients Care Clinic at the Faculty of Dentistry, Chulalongkorn University during 2019 March‒2020 March. The patients were divided into two groups: the group experienced (Exper) (n = 54) with wearing complete dentures, and the non-experienced (NonExper) group (n = 66). The patients used the validated PDA-T to self-assess their treatment at different times. The Exper group completed the questionnaire at t0 (during treatment), t0.5 (2‒8-weeks after t0), and t1 (final follow-up). The NonExper group completed the questionnaire only at t1. Results In the Exper group, Cronbach’s α and average inter-item correlation was 0.95 (range 0.76‒0.95) and 0.47 (range 0.57‒0.83), respectively. The intraclass correlation coefficients (n = 18, 95% confidence interval) were 0.98 overall. The paired t-test (p < 0.05) between t0 and t1 indicated a significant difference between t0 and t1 in every PDA-T topic, and the effect size was 1.71. In the NonExper group, the Pearson correlation analysis indicated no significant correlation between the patients' demographics and masticatory function. Conclusion The reliability and validity of the PDA-T indicate it is a valuable tool for evaluating complete denture treatment. Treatment success affected the patients' satisfaction but was not associated with the type of doctors, genders, ages, or educational level.


2016 ◽  
Vol 28 (2) ◽  
pp. 321-330 ◽  
Author(s):  
Susana C. A. Póvoas ◽  
Carlo Castagna ◽  
José Manuel da Costa Soares ◽  
Pedro Silva ◽  
Manuel Coelho-e-Silva ◽  
...  

Purpose:The reliability and construct validity of three age-adapted-intensity Yo-Yo tests were evaluated in untrained (n = 67) vs. soccer-trained (n = 65) 9- to 16-year-old schoolgirls.Methods:Tests were performed 7 days apart for reliability (9- to 11-year-old: Yo-Yo intermittent recovery level 1 children’s test; 12- to 13-yearold: Yo-Yo intermittent endurance level 1; and 14- to 16-year-old: Yo-Yo intermittent endurance level 2).Results:Yo-Yo distance covered was 40% (776 ± 324 vs. 556 ± 156 m), 85% (1252 ± 484 vs. 675 ± 252 m) and 138% (674 ± 336 vs. 283 ± 66 m) greater (p ≤ .010) for the soccer-trained than for the untrained girls aged 9–11, 12–13 and 14–16 years, respectively. Typical errors of measurement for Yo-Yo distance covered, expressed as a percentage of the coefficient of variation (confidence limits), were 10.1% (8.1–13.7%), 11.0% (8.6–15.4%) and 11.6% (9.2–16.1%) for soccer players, and 11.5% (9.1–15.8%), 14.1% (11.0–19.8%) and 10.6% (8.5–14.2%) for untrained girls, aged 9–11, 12–13 and 14–16, respectively. Intraclass correlation coefficient values for test-retest were excellent (0.795–0.973) in both groups. No significant differences were observed in relative exercise peak heart rate (%HRpeak) between groups during test and retest.Conclusion:The Yo-Yo tests are reliable for determining intermittent-exercise capacity and %HRpeak for soccer players and untrained 9- to 16-year-old girls. They also possess construct validity with better performances for soccer players compared with untrained age-matched girls, despite similar %HRpeak.


2015 ◽  
Vol 23 (1) ◽  
pp. 130-138 ◽  
Author(s):  
Daiany Borghetti Valer ◽  
Marinês Aires ◽  
Fernanda Lais Fengler ◽  
Lisiane Manganelli Girardi Paskulin

OBJECTIVE: to adapt and validate the Caregiver Burden Inventory for use with caregivers of older adults in Brazil.METHOD: methodological study involving initial translation, synthesis of translations, back translation, expert committee review, pre-testing, submission of the final version to the original authors, and assessment of the inventory's psychometric properties. The inventory assesses five dimensions of caregiver burden: time-dependence, developmental, physical, social and emotional dimensions.RESULTS: a total of 120 family caregivers took part in the study. All care-receivers were older adults dependent on assistance to perform activities of daily living, and lived in the central region of the city of Porto Alegre, RS, Brasil. Cronbach's alpha value for the inventory was 0.936, and the Pearson correlation coefficient for the relationship between the scores obtained on the Caregiver Burden Inventory and the Burden Interview was 0.814. The intraclass correlation coefficient was 0.941, and the value of Student's T-test comparing test and retest scores was 0.792.CONCLUSION: the instrument presented adequate reliability and the suitability of its items and factors was confirmed in this study.


2020 ◽  
pp. 1-4
Author(s):  
Hannah W. Tucker ◽  
Emily R. Tobin ◽  
Matthew F. Moran

Context: Performance on single-leg hopping (SLH) assessments is commonly included within return-to-sport criteria for rehabilitating athletes. Triaxial accelerometers have been used to quantify impact loading in a variety of movements, including hopping; however, they have never been attached to the tibia during SLH, and their method of fixation has not been investigated. Objective: The purpose of this study was to quantify triaxial accelerations and evaluate the influence of the fixation method of a lightweight inertial measurement unit (Blue Trident) mounted to the tibia during SLH performance. Design: Single cohort, repeated-measures experimental design. Participants: Sixteen healthy participants (10 females and 6 males; 20 [0.9] y; 1.67 [0.08] m; 66.0 [8.5] kg) met the inclusion criteria, volunteered, and completed this study. Interventions: Participants performed 2 sets of 3 SLH trials with an inertial measurement unit (1500 Hz) fixated to the tibia, each set with 1 of 2 attachment methods (double-sided tape [DST] with athletic tape and silicon strap [SS] with Velcro adhesion). Main Outcome Measures: Hop distance, peak tibial acceleration (PTA), time to PTA, and the acceleration slope were assessed during each hop landing. Results: Repeated-measures analysis of variance determined no significant effect of the attachment method on hop metrics (P = .252). Across 3 trials, both fixation methods (DST and SS) had excellent reliability values (intraclass correlation coefficient: .868–.941) for PTA and acceleration slope but not for time to PTA (intraclass correlation coefficient: .397–.768). The PTA for DST (27.22 [7.94] g) and SS (26.21 [10.48] g) was comparable and had a moderate, positive relationship (DST: r = .72, P < .01; SS: r = .77, P < .01) to SLH distance. Conclusions: Tibial inertial measurement units with triaxial accelerometers can reliably assess PTA during performance of the SLH, and SS is a viable alternative tibial attachment to DST.


Author(s):  
Mohansundar Sankaravel ◽  
Nur Ikhwan Mohamad ◽  
Aida Azmi

Bench press exercise is extensively used for chest and shoulder strength development. Joint stiffness is one of the side-effects that may occur with the exercise. This study aimed to investigate the relationship between bench press load and shoulder joint stiffness. Sixteen female rugby players (body weight 53.98 ± 7.14 kg, height 156 ± 5.38 cm) selected for Perak SUKMA 2018 team were assessed during centralized training ~9 months prior to the competition. Shoulder joint stiffness in terms of external and internal rotation range of motions were assessed by a qualified physiotherapist. The participants then performed one repetition maximum (1-RM) Bench press, according to the National Strength & Conditioning Association (NSCA)'s protocol.  Standardized warm-up and cooling-down protocol were prescribed to the participants accordingly. Pearson correlation coefficient was used for statistical correlation analysis. Both side shoulder internal and external rotation range of motion measurements showed a negative correlation (r=-0.190 internal, r=-0.285 external) with bench press (average 1-RM load 50.83 ± 9.00 kg) performance. Bench press exercises may result in reduced shoulder mobility due to an increase of muscular tightness around the joint. Maintaining normal mobility of shoulder joint throughout any strength training program is warranted and suggested. The finding also highlighted the importance of the mobility program to always be included together with a strength training programme for athletes.


2021 ◽  
Vol 8 ◽  
Author(s):  
Yunru Liao ◽  
Zhenlan Yang ◽  
Zijing Li ◽  
Rui Zeng ◽  
Jing Wang ◽  
...  

Purpose: Purpose of this study is to evaluate the measuring consistency of central refraction between multispectral refraction topography (MRT) and autorefractometry.Methods: This was a descriptive cross-sectional study including subjects in Sun Yat-sen Memorial Hospital from September 1, 2020, to December 31, 2020, ages 20 to 35 years with a best corrected visual acuity of 20/20 or better. All patients underwent cycloplegia, and the refractive status was estimated with autorefractometer, experienced optometrist and MRT. We analyzed the central refraction of the autorefractometer and MRT. The repeatability and reproducibility of values measured using both devices were evaluated using intraclass correlation coefficients (ICCs).Results: A total of 145 subjects ages 20 to 35 (290 eyes) were enrolled. The mean central refraction of the autorefractometer was −4.69 ± 2.64 diopters (D) (range −9.50 to +4.75 D), while the mean central refraction of MRT was −4.49 ± 2.61 diopters (D) (range −8.79 to +5.02 D). Pearson correlation analysis revealed a high correlation between the two devices. The intraclass correlation coefficient (ICC) also showed high agreement. The intrarater and interrater ICC values of central refraction were more than 0.90 in both devices and conditions. At the same time, the mean central refraction of experienced optometrist was −4.74 ± 2.66 diopters (D) (range −9.50 to +4.75D). The intra-class correlation coefficient of central refraction measured by MRT and subjective refraction was 0.939.Conclusions: Results revealed that autorefractometry, experienced optometrist and MRT show high agreement in measuring central refraction. MRT could provide a potential objective method to assess peripheral refraction.