scholarly journals Improving the Efficiency of the Low-Voltage Potential Application Method at Top Oxygen Blowing in Converter

2020 ◽  
Vol 16 (2) ◽  
pp. 79-86
Author(s):  
S.I. Semykin ◽  
◽  
T.S. Golub ◽  
S.O. Dudchenko ◽  
◽  
...  
2020 ◽  
Vol 16 (2) ◽  
pp. 72-79
Author(s):  
S.I. Semykin ◽  
◽  
T.S. Golub ◽  
S.O. Dudchenko ◽  
◽  
...  

2021 ◽  
Vol 17 (4) ◽  
pp. 44-54
Author(s):  
Sergiy Semykin ◽  
Tetiana Golub ◽  
Sergiy Dudchenko

Introduction. The process of oxygen conversion, despite the existing improvements, can be supplemented by physical methods of influence, including the unconventional method of applying low-voltage potential developed at the Iron and Steel Institute of the NAS of Ukraine.Problem Statement. The studies of the method of low-voltage potential application on 60, 160 and 250 ton converters have shown that the technology intensifies thermophysical and hydrodynamic processes in the gasslag-metal system and increases the converter process efficiency.Purpose. The purpose of this research is to study the features of the influence on the reaction zones of the low voltage potential application at four blowing options with the use of high-temperature physical model.Materials and Methods. A physical model that simulates the top, bottom and combined oxygen blowing under low-voltage potential application of different polarity on the lance has been used. An insert of a transparent quartz plate is made in one of the walls for visual observation and video recording. The top blowing is conductedwith two nozzle lance (nozzle diameter 1.7 mm with an angle of 30 ° to the lance). The bottom blowing is conducted with a bottom tuyere with a 1.5 mm diameter central nozzle. Combined blowing is realized by a combination ofthese options.Results. The visual observation of the reaction zones with different blowing options has shown that the highest temperature and the largest dimensions of the brightest parts of the bath correspond to the combined blowing, while the lowest ones are reported for the bottom blowing. While applying the low-voltage potential method it has been established that the reaction zone is longer at the positive polarity on the lance, during the period of silicon oxidation, and at the negative polarity on the lance, during the period of intense carbon oxidation. The video of gas bubbles flotation, probably CO, has shown that the bubbles are formed more intensively in thecase of negative polarity on the lance.Conclusions. The applied technique has allowed estimating the influence of low-voltage potential application on the geometric parameters of the reaction zone.


Soft Matter ◽  
2020 ◽  
Author(s):  
Jiahe Liao ◽  
Carmel Majidi

The surface energy of liquid metals can be electrochemically controlled over a wide range of values – from near zero to 500 mJ/m2 – using low voltage potential. (~1V). This...


Author(s):  
Marek Malecki ◽  
J. Victor Small ◽  
James Pawley

The relative roles of adhesion and locomotion in malignancy have yet to be clearly established. In a tumor, subpopulations of cells may be recognized according to their capacity to invade neighbouring tissue,or to enter the blood stream and metastasize. The mechanisms of adhesion and locomotion are themselves tightly linked to the cytoskeletal apparatus and cell surface topology, including expression of integrin receptors. In our studies on melanomas with Fluorescent Microscopy (FM) and Cell Sorter(FACS), we noticed that cells in cultures derived from metastases had more numerous actin bundles, then cells from primary foci. Following this track, we attempted to develop technology allowing to compare ultrastructure of these cells using correlative Transmission Electron Microscopy(TEM) and Low Voltage Scanning Electron Microscopy(LVSEM).


Author(s):  
Marek Malecki ◽  
James Pawley ◽  
Hans Ris

The ultrastructure of cells suspended in physiological fluids or cell culture media can only be studied if the living processes are stopped while the cells remain in suspension. Attachment of living cells to carrier surfaces to facilitate further processing for electron microscopy produces a rapid reorganization of cell structure eradicating most traces of the structures present when the cells were in suspension. The structure of cells in suspension can be immobilized by either chemical fixation or, much faster, by rapid freezing (cryo-immobilization). The fixation speed is particularly important in studies of cell surface reorganization over time. High pressure freezing provides conditions where specimens up to 500μm thick can be frozen in milliseconds without ice crystal damage. This volume is sufficient for cells to remain in suspension until frozen. However, special procedures are needed to assure that the unattached cells are not lost during subsequent processing for LVSEM or HVEM using freeze-substitution or freeze drying. We recently developed such a procedure.


Author(s):  
T. Miyokawa ◽  
S. Norioka ◽  
S. Goto

Field emission SEMs (FE-SEMs) are becoming popular due to their high resolution needs. In the field of semiconductor product, it is demanded to use the low accelerating voltage FE-SEM to avoid the electron irradiation damage and the electron charging up on samples. However the accelerating voltage of usual SEM with FE-gun is limited until 1 kV, which is not enough small for the present demands, because the virtual source goes far from the tip in lower accelerating voltages. This virtual source position depends on the shape of the electrostatic lens. So, we investigated several types of electrostatic lenses to be applicable to the lower accelerating voltage. In the result, it is found a field emission gun with a conical anode is effectively applied for a wide range of low accelerating voltages.A field emission gun usually consists of a field emission tip (cold cathode) and the Butler type electrostatic lens.


Author(s):  
E. F. Lindsey ◽  
C. W. Price ◽  
E. L. Pierce ◽  
E. J. Hsieh

Columnar structures produced by DC magnetron sputtering can be altered by using RF biased sputtering or by exposing the film to nitrogen pulses during sputtering, and these techniques are being evaluated to refine the grain structure in sputtered beryllium films deposited on fused silica substrates. Beryllium is brittle, and fractures in sputtered beryllium films tend to be intergranular; therefore, a convenient technique to analyze grain structure in these films is to fracture the coated specimens and examine them in an SEM. However, fine structure in sputtered deposits is difficult to image in an SEM, and both the low density and the low secondary electron emission coefficient of beryllium seriously compound this problem. Secondary electron emission can be improved by coating beryllium with Au or Au-Pd, and coating also was required to overcome severe charging of the fused silica substrate even at low voltage. The coating structure can obliterate much of the fine structure in beryllium films, but reasonable results were obtained by using the high-resolution capability of an Hitachi S-800 SEM and either ion-beam coating with Au-Pd or carbon coating by thermal evaporation.


Author(s):  
Zhifeng Shao

Recently, low voltage (≤5kV) scanning electron microscopes have become popular because of their unprecedented advantages, such as minimized charging effects and smaller specimen damage, etc. Perhaps the most important advantage of LVSEM is that they may be able to provide ultrahigh resolution since the interaction volume decreases when electron energy is reduced. It is obvious that no matter how low the operating voltage is, the resolution is always poorer than the probe radius. To achieve 10Å resolution at 5kV (including non-local effects), we would require a probe radius of 5∽6 Å. At low voltages, we can no longer ignore the effects of chromatic aberration because of the increased ratio δV/V. The 3rd order spherical aberration is another major limiting factor. The optimized aperture should be calculated as


Sign in / Sign up

Export Citation Format

Share Document