Radiolabelling of TiO2 Nanoparticle Libraries for Toxicological Investigations

2009 ◽  
Vol 1209 ◽  
Author(s):  
Anthony W. Musumeci ◽  
Lawrence R Gahan ◽  
Tijana Rajh ◽  
Darren J Martin ◽  
Suzanne V Smith

AbstractTo further our understanding of nanoparticle interactions with biological systems, it is important that highly sensitive, reliable and robust methods for labelling particles are established. We report here the application of a series of bi-functional cage ligands to radiolabel a range (i.e. shapes and sizes) of titanium dioxide (TiO2) particles. The cages were covalently attached to the surface of the particles via the use of a dopac derivative and then radiolabelled with a gamma emitting radioisotope. The final radiolabelled nanoparticles proved to be stable in solution and the method easy and robust. The application of a gamma emitter allows the radiolabelled particles to be tracked in vivo and in the environment.

RSC Advances ◽  
2016 ◽  
Vol 6 (94) ◽  
pp. 91102-91110 ◽  
Author(s):  
Fang Zhao ◽  
Jenny Perez Holmberg ◽  
Zareen Abbas ◽  
Rickard Frost ◽  
Tora Sirkka ◽  
...  

Different levels of model systems are needed for effect studies of engineered nanoparticles and the development of nanoparticle structure–activity relationships in biological systems.


2021 ◽  
Author(s):  
Sheng-Yi Wu ◽  
Yurong Wen ◽  
Nelson Bernard Calixte Serre ◽  
Cathrine Charlotte Heiede Laursen ◽  
Andrea Grostøl Dietz ◽  
...  

Potassium ions (K+) play a critical role as an essential electrolyte in all biological systems. Here we report the crystal structure-guided optimization and directed evolution of an improved genetically encoded fluorescent K+ biosensor, GINKO2. GINKO2 is highly sensitive and specific for K+ and enables in vivo detection of K+ dynamics in multiple species.


2019 ◽  
Vol 26 (1) ◽  
pp. 55-60 ◽  
Author(s):  
Jen Bohon

Background: First developed in the 1990’s at the National Synchrotron Light Source, xray synchrotron footprinting is an ideal technique for the analysis of solution-state structure and dynamics of macromolecules. Hydroxyl radicals generated in aqueous samples by intense x-ray beams serve as fine probes of solvent accessibility, rapidly and irreversibly reacting with solvent exposed residues to provide a “snapshot” of the sample state at the time of exposure. Over the last few decades, improvements in instrumentation to expand the technology have continuously pushed the boundaries of biological systems that can be studied using the technique. Conclusion: Dedicated synchrotron beamlines provide important resources for examining fundamental biological mechanisms of folding, ligand binding, catalysis, transcription, translation, and macromolecular assembly. The legacy of synchrotron footprinting at NSLS has led to significant improvement in our understanding of many biological systems, from identifying key structural components in enzymes and transporters to in vivo studies of ribosome assembly. This work continues at the XFP (17-BM) beamline at NSLS-II and facilities at ALS, which are currently accepting proposals for use.


2002 ◽  
Vol 10 (5) ◽  
pp. 1451-1458 ◽  
Author(s):  
Sophie Martel ◽  
Jean-Louis Clément ◽  
Agnès Muller ◽  
Marcel Culcasi ◽  
Sylvia Pietri

2021 ◽  
Vol 19 ◽  
pp. 228080002110068
Author(s):  
Hsien-Te Chen ◽  
Hsin-I Lin ◽  
Chi-Jen Chung ◽  
Chih-Hsin Tang ◽  
Ju-Liang He

Here, we present a bone implant system of phase-oriented titanium dioxide (TiO2) fabricated by the micro-arc oxidation method (MAO) on β-Ti to facilitate improved osseointegration. This (101) rutile-phase-dominant MAO TiO2 (R-TiO2) is biocompatible due to its high surface roughness, bone-mimetic structure, and preferential crystalline orientation. Furthermore, (101) R-TiO2 possesses active and abundant hydroxyl groups that play a significant role in enhancing hydroxyapatite formation and cell adhesion and promote cell activity leading to osseointegration. The implants had been elicited their favorable cellular behavior in vitro in the previous publications; in addition, they exhibit excellent shear strength and promote bone–implant contact, osteogenesis, and tissue formation in vivo. Hence, it can be concluded that this MAO R-TiO2 bone implant system provides a favorable active surface for efficient osseointegration and is suitable for clinical applications.


Author(s):  
Hessameddin Mortazavi ◽  
Hossein Omidi-Ardali ◽  
Seyed Asadollah Amini ◽  
Javad Saffari-Chaleshtori ◽  
Keihan Ghatreh Samani

2020 ◽  
Vol 9 (5) ◽  
pp. 247-251
Author(s):  
Tilmann Sander ◽  
Anna Jodko-Władzińska ◽  
Stefan Hartwig ◽  
Rüdiger Brühl ◽  
Thomas Middelmann

AbstractThe electrophysiological activities in the human body generate electric and magnetic fields that can be measured noninvasively by electrodes on the skin, or even, not requiring any contact, by magnetometers. This includes the measurement of electrical activity of brain, heart, muscles and nerves that can be measured in vivo and allows to analyze functional processes with high temporal resolution. To measure these extremely small magnetic biosignals, traditionally highly sensitive superconducting quantum-interference devices have been used, together with advanced magnetic shields. Recently, they have been complemented in usability by a new class of sensors, optically pumped magnetometers (OPMs). These quantum sensors offer a high sensitivity without requiring cryogenic temperatures, allowing the design of small and flexible sensors for clinical applications. In this letter, we describe the advantages of these upcoming OPMs in two exemplary applications that were recently carried out at Physikalisch-Technische Bundesanstalt (PTB): (1) magnetocardiography (MCG) recorded during exercise and (2) auditory-evoked fields registered by magnetoencephalography.


2021 ◽  
Author(s):  
Monojit Das ◽  
Debdeep Maity ◽  
Tusar Kanta Acharya ◽  
Sudip Sau ◽  
Chandan Giri ◽  
...  

A water-soluble PET-based chemosensor is developed which can detect Al(iii) and F− ions up to nano- and picomolar (lowest detection so far) detection limit, respectively, also utilized to establish aluminum-toxicity effect in biological systems.


2005 ◽  
Vol 49 (1) ◽  
pp. 380-387 ◽  
Author(s):  
Yan Q. Xiong ◽  
Julie Willard ◽  
Jagath L. Kadurugamuwa ◽  
Jun Yu ◽  
Kevin P. Francis ◽  
...  

ABSTRACT Therapeutic options for invasive Staphylococcus aureus infections have become limited due to rising antimicrobial resistance, making relevant animal model testing of new candidate agents more crucial than ever. In the present studies, a rat model of aortic infective endocarditis (IE) caused by a bioluminescently engineered, biofilm-positive S. aureus strain was used to evaluate real-time antibiotic efficacy directly. This strain was vancomycin and cefazolin susceptible but gentamicin resistant. Bioluminescence was detected and quantified daily in antibiotic-treated and control animals with IE, using a highly sensitive in vivo imaging system (IVIS). Persistent and increasing cardiac bioluminescent signals (BLS) were observed in untreated animals. Three days of vancomycin therapy caused significant reductions in both cardiac BLS (>10-fold versus control) and S. aureus densities in cardiac vegetations (P < 0.005 versus control). However, 3 days after discontinuation of vancomycin therapy, a greater than threefold increase in cardiac BLS was observed, indicating relapsing IE (which was confirmed by quantitative culture). Cefazolin resulted in modest decreases in cardiac BLS and bacterial densities. These microbiologic and cardiac BLS differences during therapy correlated with a longer time-above-MIC for vancomycin (>12 h) than for cefazolin (∼4 h). Gentamicin caused neither a reduction in cardiac S. aureus densities nor a reduction in BLS. There were significant correlations between cardiac BLS and S. aureus densities in vegetations in all treatment groups. These data suggest that bioluminescent imaging provides a substantial advance in the real-time monitoring of the efficacy of therapy of invasive S. aureus infections in live animals.


Sign in / Sign up

Export Citation Format

Share Document