Mechanical properties of high-performance concrete under triaxial compression

2021 ◽  
pp. 1-13
Author(s):  
Xiaojun Ke ◽  
Weishu Fu ◽  
Zongping Chen

It is well known that the mechanical properties of a material are related to lateral confinement. In this paper, 60 cylindrical high-performance concrete (HPC) specimens with different concrete strength grades were cast and subjected to a conventional triaxial experiment to study the mechanical properties of the material. The experimental results indicated that the specimens exhibited longitudinal splitting failure patterns under uniaxial compression and inclined plane shear failure patterns under triaxial compression. The stress–strain curves were divided into three stages: an elastic rising stage, a plastic rising stage and a softening descending stage. The application of lateral confining pressure effectively increased the triaxial compressive strength. As the concrete strength increased, the descending stage of the stress–strain curves became steeper, indicating an increase in brittleness. Based on the experimental results, the failure criterion of the HPC was analysed using the Drucker–Prager yield criterion and Kotsovos failure theory. The parameters of the Drucker–Prager yield criterion were determined, and the applicable range of the Kotsovos failure theory was also obtained.

2021 ◽  
Vol 13 (23) ◽  
pp. 13392
Author(s):  
Moawiah Mubarak ◽  
Raizal Saifulnaaz Muhammad Rashid ◽  
Mugahed Amran ◽  
Roman Fediuk ◽  
Nikolai Vatin ◽  
...  

Deterioration of concrete’s integrity under elevated temperature requires an alteration in its composition to have better thermal stability. Fibre-reinforced concrete has shown significant improvements in concrete strength and this paper aimed to investigate the influence of steel (ST) and polypropylene (PP) fibres on the behaviour of high-performance concrete (HPC) exposed to elevated temperatures. Six mixtures were prepared and cast by adding one or two types of polypropylene fibre (54 and 9 mm) at 0.25 or 0.5% and either singly or in a hybrid combination, along with a fixed volumetric content at 1% of five-dimensional hooked steel (5DH) fibres. At the age of 28 days, samples were heated to the targeted temperature of 800 °C and cooled down naturally to the laboratory temperature. Visual inspection, flexural, split tensile and compressive strengths were examined before and after the exposure to elevated temperatures. Results exhibited that the hybridization of long and short PP fibres, along with the ST fibres, has notably improved all residual mechanical properties of HPC and kept the integrity of concrete after exposure to elevated temperatures. In addition, PP fibres can significantly prevent spalling, but ST fibres were ineffective in mitigating explosive spalling in beams specimens.


PCI Journal ◽  
2008 ◽  
Vol 53 (4) ◽  
pp. 108-130
Author(s):  
Mohsen A. Issa ◽  
Atef A. Khalil ◽  
Shahidul Islam ◽  
Paul D. Krauss

Materials ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4102
Author(s):  
Jan Stindt ◽  
Patrick Forman ◽  
Peter Mark

Resource-efficient precast concrete elements can be produced using high-performance concrete (HPC). A heat treatment accelerates hardening and thus enables early stripping. To minimise damages to the concrete structure, treatment time and temperature are regulated. This leads to temperature treatment times of more than 24 h, what seems too long for quick serial production (flow production) of HPC. To overcome this shortcoming and to accelerate production speed, the heat treatment is started here immediately after concreting. This in turn influences the shrinkage behaviour and the concrete strength. Therefore, shrinkage is investigated on prisms made from HPC with and without steel fibres, as well as on short beams with reinforcement ratios of 1.8% and 3.1%. Furthermore, the flexural and compressive strengths of the prisms are measured directly after heating and later on after 28 d. The specimens are heat-treated between 1 and 24 h at 80 °C and a relative humidity of 60%. Specimens without heating serve for reference. The results show that the shrinkage strain is pronouncedly reduced with increasing temperature duration and rebar ratio. Moreover, the compressive and flexural strength decrease with decreasing temperature duration, whereby the loss of strength can be compensated by adding steel fibres.


Materials ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2455
Author(s):  
Jiayuan He ◽  
Weizhen Chen ◽  
Boshan Zhang ◽  
Jiangjiang Yu ◽  
Hang Liu

Due to the sharp and corrosion-prone features of steel fibers, there is a demand for ultra-high-performance concrete (UHPC) reinforced with nonmetallic fibers. In this paper, glass fiber (GF) and the high-performance polypropylene (HPP) fiber were selected to prepare UHPC, and the effects of different fibers on the compressive, tensile and bending properties of UHPC were investigated, experimentally and numerically. Then, the damage evolution of UHPC was further studied numerically, adopting the concrete damaged plasticity (CDP) model. The difference between the simulation values and experimental values was within 5.0%, verifying the reliability of the numerical model. The results indicate that 2.0% fiber content in UHPC provides better mechanical properties. In addition, the glass fiber was more significant in strengthening the effect. Compared with HPP-UHPC, the compressive, tensile and flexural strength of GF-UHPC increased by about 20%, 30% and 40%, respectively. However, the flexural toughness indexes I5, I10 and I20 of HPP-UHPC were about 1.2, 2.0 and 3.8 times those of GF-UHPC, respectively, showing that the toughening effect of the HPP fiber is better.


Crystals ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 427
Author(s):  
Pavlina Mateckova ◽  
Vlastimil Bilek ◽  
Oldrich Sucharda

High-performance concrete (HPC) is subjected to wide attention in current research. Many research tasks are focused on laboratory testing of concrete mechanical properties with specific raw materials, where a mixture is prepared in a relatively small amount in ideal conditions. The wider utilization of HPC is connected, among other things, with its utilization in the construction industry. The paper presents two variants of HPC which were developed by modification of ordinary concrete used by a precast company for pretensioned bridge beams. The presented variants were produced in industrial conditions using common raw materials. Testing and comparison of basic mechanical properties are complemented with specialized tests of the resistance to chloride penetration. Tentative expenses for normal strength concrete (NSC) and HPC are compared. The research program was accomplished with a loading test of model experimental pretensioned beams with a length of 7 m made of ordinarily used concrete and one variant of HPC. The aim of the loading test was to determine the load–deformation diagrams and verify the design code load capacity calculation method. Overall, the article summarizes the possible benefits of using HPC compared to conventional concrete.


2015 ◽  
Vol 773-774 ◽  
pp. 949-953 ◽  
Author(s):  
Izni Syahrizal Ibrahim ◽  
Wan Amizah Wan Jusoh ◽  
Abdul Rahman Mohd Sam ◽  
Nur Ain Mustapa ◽  
Sk Muiz Sk Abdul Razak

This paper discusses the experimental results on the mechanical properties of hybrid fibre reinforced composite concrete (HyFRCC) containing different proportions of steel fibre (SF) and polypropylene fibre (PPF). The mechanical properties include compressive strength, tensile strength, and flexural strength. SF is known to enhance the flexural and tensile strengths, and at the same time is able to resist the formation of macro cracking. Meanwhile, PPF contributes to the tensile strain capacity and compressive strength, and also delay the formation of micro cracks. Hooked-end deformed type SF fibre with 60 mm length and fibrillated virgin type PPF fibre with 19 mm length are used in this study. Meanwhile, the concrete strength is maintained for grade C30. The percentage proportion of SF-PPF fibres are varied in the range of 100-0%, 75-25%, 50-50%, 25-75% and 0-100% of which the total fibre volume fraction (Vf) is fixed at 0.5%. The experimental results reveal that the percentage proportion of SF-PPF fibres with 75-25% produced the maximum performance of flexural strength, tensile strength and flexural toughness. Meanwhile, the percentage proportion of SF-PPF fibres with 100-0% contributes to the improvement of the compressive strength compared to that of plain concrete.


Author(s):  
HongBin Liu ◽  
KaiLu Xiao ◽  
WeiQi Tang ◽  
WeiZhe Ma ◽  
ZhengQi Shi ◽  
...  

2019 ◽  
Vol 33 (01n03) ◽  
pp. 1940054 ◽  
Author(s):  
Rongrong Yin ◽  
Jie Hu ◽  
Yu Liu ◽  
Qing Wu ◽  
Chenchen Zhang ◽  
...  

The thickness of corroded concrete layer and the compressive strength of prisms under the action of sulfate and chloride salt were investigated by ultrasonic test and compression test, respectively. The results show that under the single action of sulfate, the strength of concrete experienced two stages: a slow growth stage and a rapid descent stage. Correspondingly, under the combined action of sulfate and chloride, the concrete strength experienced another two stages: a slow growth stage and a slow degradation stage. The existence of chloride inhibited the corrosion damage of concrete in a certain extent. It was found that higher concentration of chlorine salt would lead to a stronger inhibition effect. A good consistency was observed among corrosion layer thickness, compressive strength and X-ray diffraction results. The inhabitation of chloride to the sulfate corrosion of concrete was proved.


Sign in / Sign up

Export Citation Format

Share Document